Picometer-scale OAM interferometry using an adaptive polar transform algorithm

A phase demodulation algorithm based on an adaptive polar transform is proposed that can achieve picometer-scale measurements in orbital angular momentum (OAM) interferometry. The proposed algorithm converts the rotational movement in a petal-shaped interference pattern into translational movement o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Optics express 2024-11, Vol.32 (23), p.40227
Hauptverfasser: Ni, Lanlin, Xia, Haojie, Xu, FeiFan, Wu, Qiang, Zhang, Jin, Chang, Songtao
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 23
container_start_page 40227
container_title Optics express
container_volume 32
creator Ni, Lanlin
Xia, Haojie
Xu, FeiFan
Wu, Qiang
Zhang, Jin
Chang, Songtao
description A phase demodulation algorithm based on an adaptive polar transform is proposed that can achieve picometer-scale measurements in orbital angular momentum (OAM) interferometry. The proposed algorithm converts the rotational movement in a petal-shaped interference pattern into translational movement of the grayscale projection curves, so that can be easily measured using correlation operations to determine the pixel displacement in determining the rotation angle. Displacements ranging from -120 nm to 120 nm have been measured for various topological charges, with a minimum average deviation of 0.07 nm. Furthermore, we have studied the effects of piezoelectric transducer alignment, various binary threshold values, fringe occlusion, and charge-coupled device (CCD) camera resolutions on displacement measurement. Comparative experiments indicate that the proposed algorithm can effectively manage the local measurement challenges in traditional OAM interferometers, demonstrating better measurement accuracy and robustness than several existing phase demodulation algorithms.
doi_str_mv 10.1364/OE.539096
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3131853073</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3131853073</sourcerecordid><originalsourceid>FETCH-LOGICAL-c210t-ca2f054496d51505b401859157bc7cd82a81b1ba4faf1ccbf3af21d98991bf9e3</originalsourceid><addsrcrecordid>eNpNkMtOwzAQRS0EoqWw4AeQl7BI8cR2Ei-rqjykQljAOpo4dgnKCzup1L8nVQtiNTO6R1eaQ8g1sDnwSNynq7nkiqnohEyBKREIlsSn__YJufD-izEQsYrPyYQrGXMeJVPy-lbqtja9cYHXWBmaLl5o2Yy3NW4fuB0dfNlsKDYUC-z6cmto11boaO-w8bZ1NcVq07qy_6wvyZnFypur45yRj4fV-_IpWKePz8vFOtAhsD7QGFomhVBRIUEymQsGiVQg41zHukhCTCCHHIVFC1rnlqMNoVCJUpBbZfiM3B56O9d-D8b3WV16baoKG9MOPuPAx0LOxi9n5O6Aatd674zNOlfW6HYZsGyvL0tX2UHfyN4ca4e8NsUf-euL_wAjlGrK</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3131853073</pqid></control><display><type>article</type><title>Picometer-scale OAM interferometry using an adaptive polar transform algorithm</title><source>DOAJ Directory of Open Access Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Ni, Lanlin ; Xia, Haojie ; Xu, FeiFan ; Wu, Qiang ; Zhang, Jin ; Chang, Songtao</creator><creatorcontrib>Ni, Lanlin ; Xia, Haojie ; Xu, FeiFan ; Wu, Qiang ; Zhang, Jin ; Chang, Songtao</creatorcontrib><description>A phase demodulation algorithm based on an adaptive polar transform is proposed that can achieve picometer-scale measurements in orbital angular momentum (OAM) interferometry. The proposed algorithm converts the rotational movement in a petal-shaped interference pattern into translational movement of the grayscale projection curves, so that can be easily measured using correlation operations to determine the pixel displacement in determining the rotation angle. Displacements ranging from -120 nm to 120 nm have been measured for various topological charges, with a minimum average deviation of 0.07 nm. Furthermore, we have studied the effects of piezoelectric transducer alignment, various binary threshold values, fringe occlusion, and charge-coupled device (CCD) camera resolutions on displacement measurement. Comparative experiments indicate that the proposed algorithm can effectively manage the local measurement challenges in traditional OAM interferometers, demonstrating better measurement accuracy and robustness than several existing phase demodulation algorithms.</description><identifier>ISSN: 1094-4087</identifier><identifier>EISSN: 1094-4087</identifier><identifier>DOI: 10.1364/OE.539096</identifier><identifier>PMID: 39573368</identifier><language>eng</language><publisher>United States</publisher><ispartof>Optics express, 2024-11, Vol.32 (23), p.40227</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c210t-ca2f054496d51505b401859157bc7cd82a81b1ba4faf1ccbf3af21d98991bf9e3</cites><orcidid>0000-0002-4214-7233 ; 0000-0001-5462-3631 ; 0009-0003-3634-0015</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,864,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39573368$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ni, Lanlin</creatorcontrib><creatorcontrib>Xia, Haojie</creatorcontrib><creatorcontrib>Xu, FeiFan</creatorcontrib><creatorcontrib>Wu, Qiang</creatorcontrib><creatorcontrib>Zhang, Jin</creatorcontrib><creatorcontrib>Chang, Songtao</creatorcontrib><title>Picometer-scale OAM interferometry using an adaptive polar transform algorithm</title><title>Optics express</title><addtitle>Opt Express</addtitle><description>A phase demodulation algorithm based on an adaptive polar transform is proposed that can achieve picometer-scale measurements in orbital angular momentum (OAM) interferometry. The proposed algorithm converts the rotational movement in a petal-shaped interference pattern into translational movement of the grayscale projection curves, so that can be easily measured using correlation operations to determine the pixel displacement in determining the rotation angle. Displacements ranging from -120 nm to 120 nm have been measured for various topological charges, with a minimum average deviation of 0.07 nm. Furthermore, we have studied the effects of piezoelectric transducer alignment, various binary threshold values, fringe occlusion, and charge-coupled device (CCD) camera resolutions on displacement measurement. Comparative experiments indicate that the proposed algorithm can effectively manage the local measurement challenges in traditional OAM interferometers, demonstrating better measurement accuracy and robustness than several existing phase demodulation algorithms.</description><issn>1094-4087</issn><issn>1094-4087</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNpNkMtOwzAQRS0EoqWw4AeQl7BI8cR2Ei-rqjykQljAOpo4dgnKCzup1L8nVQtiNTO6R1eaQ8g1sDnwSNynq7nkiqnohEyBKREIlsSn__YJufD-izEQsYrPyYQrGXMeJVPy-lbqtja9cYHXWBmaLl5o2Yy3NW4fuB0dfNlsKDYUC-z6cmto11boaO-w8bZ1NcVq07qy_6wvyZnFypur45yRj4fV-_IpWKePz8vFOtAhsD7QGFomhVBRIUEymQsGiVQg41zHukhCTCCHHIVFC1rnlqMNoVCJUpBbZfiM3B56O9d-D8b3WV16baoKG9MOPuPAx0LOxi9n5O6Aatd674zNOlfW6HYZsGyvL0tX2UHfyN4ca4e8NsUf-euL_wAjlGrK</recordid><startdate>20241104</startdate><enddate>20241104</enddate><creator>Ni, Lanlin</creator><creator>Xia, Haojie</creator><creator>Xu, FeiFan</creator><creator>Wu, Qiang</creator><creator>Zhang, Jin</creator><creator>Chang, Songtao</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-4214-7233</orcidid><orcidid>https://orcid.org/0000-0001-5462-3631</orcidid><orcidid>https://orcid.org/0009-0003-3634-0015</orcidid></search><sort><creationdate>20241104</creationdate><title>Picometer-scale OAM interferometry using an adaptive polar transform algorithm</title><author>Ni, Lanlin ; Xia, Haojie ; Xu, FeiFan ; Wu, Qiang ; Zhang, Jin ; Chang, Songtao</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c210t-ca2f054496d51505b401859157bc7cd82a81b1ba4faf1ccbf3af21d98991bf9e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ni, Lanlin</creatorcontrib><creatorcontrib>Xia, Haojie</creatorcontrib><creatorcontrib>Xu, FeiFan</creatorcontrib><creatorcontrib>Wu, Qiang</creatorcontrib><creatorcontrib>Zhang, Jin</creatorcontrib><creatorcontrib>Chang, Songtao</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Optics express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ni, Lanlin</au><au>Xia, Haojie</au><au>Xu, FeiFan</au><au>Wu, Qiang</au><au>Zhang, Jin</au><au>Chang, Songtao</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Picometer-scale OAM interferometry using an adaptive polar transform algorithm</atitle><jtitle>Optics express</jtitle><addtitle>Opt Express</addtitle><date>2024-11-04</date><risdate>2024</risdate><volume>32</volume><issue>23</issue><spage>40227</spage><pages>40227-</pages><issn>1094-4087</issn><eissn>1094-4087</eissn><abstract>A phase demodulation algorithm based on an adaptive polar transform is proposed that can achieve picometer-scale measurements in orbital angular momentum (OAM) interferometry. The proposed algorithm converts the rotational movement in a petal-shaped interference pattern into translational movement of the grayscale projection curves, so that can be easily measured using correlation operations to determine the pixel displacement in determining the rotation angle. Displacements ranging from -120 nm to 120 nm have been measured for various topological charges, with a minimum average deviation of 0.07 nm. Furthermore, we have studied the effects of piezoelectric transducer alignment, various binary threshold values, fringe occlusion, and charge-coupled device (CCD) camera resolutions on displacement measurement. Comparative experiments indicate that the proposed algorithm can effectively manage the local measurement challenges in traditional OAM interferometers, demonstrating better measurement accuracy and robustness than several existing phase demodulation algorithms.</abstract><cop>United States</cop><pmid>39573368</pmid><doi>10.1364/OE.539096</doi><orcidid>https://orcid.org/0000-0002-4214-7233</orcidid><orcidid>https://orcid.org/0000-0001-5462-3631</orcidid><orcidid>https://orcid.org/0009-0003-3634-0015</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1094-4087
ispartof Optics express, 2024-11, Vol.32 (23), p.40227
issn 1094-4087
1094-4087
language eng
recordid cdi_proquest_miscellaneous_3131853073
source DOAJ Directory of Open Access Journals; EZB-FREE-00999 freely available EZB journals
title Picometer-scale OAM interferometry using an adaptive polar transform algorithm
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T01%3A55%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Picometer-scale%20OAM%20interferometry%20using%20an%20adaptive%20polar%20transform%20algorithm&rft.jtitle=Optics%20express&rft.au=Ni,%20Lanlin&rft.date=2024-11-04&rft.volume=32&rft.issue=23&rft.spage=40227&rft.pages=40227-&rft.issn=1094-4087&rft.eissn=1094-4087&rft_id=info:doi/10.1364/OE.539096&rft_dat=%3Cproquest_cross%3E3131853073%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3131853073&rft_id=info:pmid/39573368&rfr_iscdi=true