Picometer-scale OAM interferometry using an adaptive polar transform algorithm
A phase demodulation algorithm based on an adaptive polar transform is proposed that can achieve picometer-scale measurements in orbital angular momentum (OAM) interferometry. The proposed algorithm converts the rotational movement in a petal-shaped interference pattern into translational movement o...
Gespeichert in:
Veröffentlicht in: | Optics express 2024-11, Vol.32 (23), p.40227 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 23 |
container_start_page | 40227 |
container_title | Optics express |
container_volume | 32 |
creator | Ni, Lanlin Xia, Haojie Xu, FeiFan Wu, Qiang Zhang, Jin Chang, Songtao |
description | A phase demodulation algorithm based on an adaptive polar transform is proposed that can achieve picometer-scale measurements in orbital angular momentum (OAM) interferometry. The proposed algorithm converts the rotational movement in a petal-shaped interference pattern into translational movement of the grayscale projection curves, so that can be easily measured using correlation operations to determine the pixel displacement in determining the rotation angle. Displacements ranging from -120 nm to 120 nm have been measured for various topological charges, with a minimum average deviation of 0.07 nm. Furthermore, we have studied the effects of piezoelectric transducer alignment, various binary threshold values, fringe occlusion, and charge-coupled device (CCD) camera resolutions on displacement measurement. Comparative experiments indicate that the proposed algorithm can effectively manage the local measurement challenges in traditional OAM interferometers, demonstrating better measurement accuracy and robustness than several existing phase demodulation algorithms. |
doi_str_mv | 10.1364/OE.539096 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3131853073</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3131853073</sourcerecordid><originalsourceid>FETCH-LOGICAL-c210t-ca2f054496d51505b401859157bc7cd82a81b1ba4faf1ccbf3af21d98991bf9e3</originalsourceid><addsrcrecordid>eNpNkMtOwzAQRS0EoqWw4AeQl7BI8cR2Ei-rqjykQljAOpo4dgnKCzup1L8nVQtiNTO6R1eaQ8g1sDnwSNynq7nkiqnohEyBKREIlsSn__YJufD-izEQsYrPyYQrGXMeJVPy-lbqtja9cYHXWBmaLl5o2Yy3NW4fuB0dfNlsKDYUC-z6cmto11boaO-w8bZ1NcVq07qy_6wvyZnFypur45yRj4fV-_IpWKePz8vFOtAhsD7QGFomhVBRIUEymQsGiVQg41zHukhCTCCHHIVFC1rnlqMNoVCJUpBbZfiM3B56O9d-D8b3WV16baoKG9MOPuPAx0LOxi9n5O6Aatd674zNOlfW6HYZsGyvL0tX2UHfyN4ca4e8NsUf-euL_wAjlGrK</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3131853073</pqid></control><display><type>article</type><title>Picometer-scale OAM interferometry using an adaptive polar transform algorithm</title><source>DOAJ Directory of Open Access Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Ni, Lanlin ; Xia, Haojie ; Xu, FeiFan ; Wu, Qiang ; Zhang, Jin ; Chang, Songtao</creator><creatorcontrib>Ni, Lanlin ; Xia, Haojie ; Xu, FeiFan ; Wu, Qiang ; Zhang, Jin ; Chang, Songtao</creatorcontrib><description>A phase demodulation algorithm based on an adaptive polar transform is proposed that can achieve picometer-scale measurements in orbital angular momentum (OAM) interferometry. The proposed algorithm converts the rotational movement in a petal-shaped interference pattern into translational movement of the grayscale projection curves, so that can be easily measured using correlation operations to determine the pixel displacement in determining the rotation angle. Displacements ranging from -120 nm to 120 nm have been measured for various topological charges, with a minimum average deviation of 0.07 nm. Furthermore, we have studied the effects of piezoelectric transducer alignment, various binary threshold values, fringe occlusion, and charge-coupled device (CCD) camera resolutions on displacement measurement. Comparative experiments indicate that the proposed algorithm can effectively manage the local measurement challenges in traditional OAM interferometers, demonstrating better measurement accuracy and robustness than several existing phase demodulation algorithms.</description><identifier>ISSN: 1094-4087</identifier><identifier>EISSN: 1094-4087</identifier><identifier>DOI: 10.1364/OE.539096</identifier><identifier>PMID: 39573368</identifier><language>eng</language><publisher>United States</publisher><ispartof>Optics express, 2024-11, Vol.32 (23), p.40227</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c210t-ca2f054496d51505b401859157bc7cd82a81b1ba4faf1ccbf3af21d98991bf9e3</cites><orcidid>0000-0002-4214-7233 ; 0000-0001-5462-3631 ; 0009-0003-3634-0015</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,864,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39573368$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ni, Lanlin</creatorcontrib><creatorcontrib>Xia, Haojie</creatorcontrib><creatorcontrib>Xu, FeiFan</creatorcontrib><creatorcontrib>Wu, Qiang</creatorcontrib><creatorcontrib>Zhang, Jin</creatorcontrib><creatorcontrib>Chang, Songtao</creatorcontrib><title>Picometer-scale OAM interferometry using an adaptive polar transform algorithm</title><title>Optics express</title><addtitle>Opt Express</addtitle><description>A phase demodulation algorithm based on an adaptive polar transform is proposed that can achieve picometer-scale measurements in orbital angular momentum (OAM) interferometry. The proposed algorithm converts the rotational movement in a petal-shaped interference pattern into translational movement of the grayscale projection curves, so that can be easily measured using correlation operations to determine the pixel displacement in determining the rotation angle. Displacements ranging from -120 nm to 120 nm have been measured for various topological charges, with a minimum average deviation of 0.07 nm. Furthermore, we have studied the effects of piezoelectric transducer alignment, various binary threshold values, fringe occlusion, and charge-coupled device (CCD) camera resolutions on displacement measurement. Comparative experiments indicate that the proposed algorithm can effectively manage the local measurement challenges in traditional OAM interferometers, demonstrating better measurement accuracy and robustness than several existing phase demodulation algorithms.</description><issn>1094-4087</issn><issn>1094-4087</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNpNkMtOwzAQRS0EoqWw4AeQl7BI8cR2Ei-rqjykQljAOpo4dgnKCzup1L8nVQtiNTO6R1eaQ8g1sDnwSNynq7nkiqnohEyBKREIlsSn__YJufD-izEQsYrPyYQrGXMeJVPy-lbqtja9cYHXWBmaLl5o2Yy3NW4fuB0dfNlsKDYUC-z6cmto11boaO-w8bZ1NcVq07qy_6wvyZnFypur45yRj4fV-_IpWKePz8vFOtAhsD7QGFomhVBRIUEymQsGiVQg41zHukhCTCCHHIVFC1rnlqMNoVCJUpBbZfiM3B56O9d-D8b3WV16baoKG9MOPuPAx0LOxi9n5O6Aatd674zNOlfW6HYZsGyvL0tX2UHfyN4ca4e8NsUf-euL_wAjlGrK</recordid><startdate>20241104</startdate><enddate>20241104</enddate><creator>Ni, Lanlin</creator><creator>Xia, Haojie</creator><creator>Xu, FeiFan</creator><creator>Wu, Qiang</creator><creator>Zhang, Jin</creator><creator>Chang, Songtao</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-4214-7233</orcidid><orcidid>https://orcid.org/0000-0001-5462-3631</orcidid><orcidid>https://orcid.org/0009-0003-3634-0015</orcidid></search><sort><creationdate>20241104</creationdate><title>Picometer-scale OAM interferometry using an adaptive polar transform algorithm</title><author>Ni, Lanlin ; Xia, Haojie ; Xu, FeiFan ; Wu, Qiang ; Zhang, Jin ; Chang, Songtao</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c210t-ca2f054496d51505b401859157bc7cd82a81b1ba4faf1ccbf3af21d98991bf9e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ni, Lanlin</creatorcontrib><creatorcontrib>Xia, Haojie</creatorcontrib><creatorcontrib>Xu, FeiFan</creatorcontrib><creatorcontrib>Wu, Qiang</creatorcontrib><creatorcontrib>Zhang, Jin</creatorcontrib><creatorcontrib>Chang, Songtao</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Optics express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ni, Lanlin</au><au>Xia, Haojie</au><au>Xu, FeiFan</au><au>Wu, Qiang</au><au>Zhang, Jin</au><au>Chang, Songtao</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Picometer-scale OAM interferometry using an adaptive polar transform algorithm</atitle><jtitle>Optics express</jtitle><addtitle>Opt Express</addtitle><date>2024-11-04</date><risdate>2024</risdate><volume>32</volume><issue>23</issue><spage>40227</spage><pages>40227-</pages><issn>1094-4087</issn><eissn>1094-4087</eissn><abstract>A phase demodulation algorithm based on an adaptive polar transform is proposed that can achieve picometer-scale measurements in orbital angular momentum (OAM) interferometry. The proposed algorithm converts the rotational movement in a petal-shaped interference pattern into translational movement of the grayscale projection curves, so that can be easily measured using correlation operations to determine the pixel displacement in determining the rotation angle. Displacements ranging from -120 nm to 120 nm have been measured for various topological charges, with a minimum average deviation of 0.07 nm. Furthermore, we have studied the effects of piezoelectric transducer alignment, various binary threshold values, fringe occlusion, and charge-coupled device (CCD) camera resolutions on displacement measurement. Comparative experiments indicate that the proposed algorithm can effectively manage the local measurement challenges in traditional OAM interferometers, demonstrating better measurement accuracy and robustness than several existing phase demodulation algorithms.</abstract><cop>United States</cop><pmid>39573368</pmid><doi>10.1364/OE.539096</doi><orcidid>https://orcid.org/0000-0002-4214-7233</orcidid><orcidid>https://orcid.org/0000-0001-5462-3631</orcidid><orcidid>https://orcid.org/0009-0003-3634-0015</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1094-4087 |
ispartof | Optics express, 2024-11, Vol.32 (23), p.40227 |
issn | 1094-4087 1094-4087 |
language | eng |
recordid | cdi_proquest_miscellaneous_3131853073 |
source | DOAJ Directory of Open Access Journals; EZB-FREE-00999 freely available EZB journals |
title | Picometer-scale OAM interferometry using an adaptive polar transform algorithm |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T01%3A55%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Picometer-scale%20OAM%20interferometry%20using%20an%20adaptive%20polar%20transform%20algorithm&rft.jtitle=Optics%20express&rft.au=Ni,%20Lanlin&rft.date=2024-11-04&rft.volume=32&rft.issue=23&rft.spage=40227&rft.pages=40227-&rft.issn=1094-4087&rft.eissn=1094-4087&rft_id=info:doi/10.1364/OE.539096&rft_dat=%3Cproquest_cross%3E3131853073%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3131853073&rft_id=info:pmid/39573368&rfr_iscdi=true |