Does the use of a 3-mm extended tray during an at-home bleaching treatment increase gingival irritation? A randomized clinical trial

Gingival irritation is a common side effect of at-home bleaching, but how the design of the bleaching tray affects its occurrence is unclear. The purpose of this randomized clinical trial was to determine whether a direct relationship is present between the design of bleaching trays and the risk of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of prosthetic dentistry 2024-11
Hauptverfasser: Pereira-Lores, Patricia, Martín-González, Jenifer, Gancedo-Gancedo, Tania, Alonso de la Peña, Víctor, Álvarez-Nóvoa, Pablo, Varela-Aneiros, Iván, Abella-Sans, Francesc, Martín-Biedma, Benjamín, Castelo-Baz, Pablo
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title The Journal of prosthetic dentistry
container_volume
creator Pereira-Lores, Patricia
Martín-González, Jenifer
Gancedo-Gancedo, Tania
Alonso de la Peña, Víctor
Álvarez-Nóvoa, Pablo
Varela-Aneiros, Iván
Abella-Sans, Francesc
Martín-Biedma, Benjamín
Castelo-Baz, Pablo
description Gingival irritation is a common side effect of at-home bleaching, but how the design of the bleaching tray affects its occurrence is unclear. The purpose of this randomized clinical trial was to determine whether a direct relationship is present between the design of bleaching trays and the risk of gingival irritation during at-home bleaching treatments. This clinical trial was registered at ClinicalTrials.gov. (NCT06371664). Seventy-two participants were randomly assigned to 2 experimental groups: extended bleaching tray (3 mm) and nonextended bleaching tray (1 mm). Over a period of 3 weeks, participants underwent a nightguard dental bleaching treatment (6 to 8 hours) using 16% carbamide peroxide gel. Gingival irritation was evaluated subjectively by participants daily and objectively by clinicians at each visit. Tooth sensitivity was recorded daily using a 5-point numerical scale. Tooth color measurements were also made with a dental spectrophotometer. The risk of gingival irritation and the risk and intensity of tooth sensitivity were analyzed with the Pearson chi squared test and Fisher exact test. The color analysis was conducted with the Student t test (α=.05). Subjectively, the risk of gingival irritation was 66.7% in the extended group and 47.2% in the nonextended group, showing no statistically significant difference (P>.05). However, objectively, the risk of gingival irritation was significantly higher in the extended group (88.9%) compared with the nonextended group (63.9%) (P=.01(95% CI 1.06 to 1.83). Tooth sensitivity intensity was significantly higher in the extended tray group (P.05). No significant differences were found between groups regarding color change (P>.05). The use of an extended bleaching tray design increases the risk of gingival irritation and the intensity of tooth sensitivity. Therefore, the nonextended tray is recommended to minimize adverse reactions.
doi_str_mv 10.1016/j.prosdent.2024.09.029
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3130827051</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0022391324006905</els_id><sourcerecordid>3130827051</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1609-c57319c975bdb34a1b84e24b6ac49f6136bb96f2a75dff936f94c65e5344753</originalsourceid><addsrcrecordid>eNqFkE1P3DAQhi0Egi3tX0A-cknq76xPLeKjRULi0N4tx56wXiUOtR0EPfPD8Wqh155mNHrmHftB6IySlhKqvm7bxzRnD7G0jDDREt0Spg_QihLdNWot6CFaEcJYwzXlJ-hTzltCyFp29BidcC0VY1Sv0OvVDBmXDeAlA54HbDFvpgnDc4HoweOS7Av2SwrxAduIbWk28wS4H8G6zW5YEtgy1YfgEF3ta8xDnYcnO-KQUii2hDl-wxc42ejnKfytqW4MMbhKlBTs-BkdDXbM8OW9nqJfN9e_L382d_c_bi8v7hpHFdGNkx2n2ulO9r7nwtJ-LYCJXlkn9KAoV32v1cBsJ_0waK4GLZySILkQneSn6HyfWs39WSAXM4XsYBxthHnJhlNO1qwjklZU7VFXJecEg3lMYbLpxVBidv7N1nz4Nzv_hmhT_dfFs_cbSz-B_7f2IbwC3_cA1H8-BUgmuwDRgQ8JXDF-Dv-78QbK55u5</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3130827051</pqid></control><display><type>article</type><title>Does the use of a 3-mm extended tray during an at-home bleaching treatment increase gingival irritation? A randomized clinical trial</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Pereira-Lores, Patricia ; Martín-González, Jenifer ; Gancedo-Gancedo, Tania ; Alonso de la Peña, Víctor ; Álvarez-Nóvoa, Pablo ; Varela-Aneiros, Iván ; Abella-Sans, Francesc ; Martín-Biedma, Benjamín ; Castelo-Baz, Pablo</creator><creatorcontrib>Pereira-Lores, Patricia ; Martín-González, Jenifer ; Gancedo-Gancedo, Tania ; Alonso de la Peña, Víctor ; Álvarez-Nóvoa, Pablo ; Varela-Aneiros, Iván ; Abella-Sans, Francesc ; Martín-Biedma, Benjamín ; Castelo-Baz, Pablo</creatorcontrib><description>Gingival irritation is a common side effect of at-home bleaching, but how the design of the bleaching tray affects its occurrence is unclear. The purpose of this randomized clinical trial was to determine whether a direct relationship is present between the design of bleaching trays and the risk of gingival irritation during at-home bleaching treatments. This clinical trial was registered at ClinicalTrials.gov. (NCT06371664). Seventy-two participants were randomly assigned to 2 experimental groups: extended bleaching tray (3 mm) and nonextended bleaching tray (1 mm). Over a period of 3 weeks, participants underwent a nightguard dental bleaching treatment (6 to 8 hours) using 16% carbamide peroxide gel. Gingival irritation was evaluated subjectively by participants daily and objectively by clinicians at each visit. Tooth sensitivity was recorded daily using a 5-point numerical scale. Tooth color measurements were also made with a dental spectrophotometer. The risk of gingival irritation and the risk and intensity of tooth sensitivity were analyzed with the Pearson chi squared test and Fisher exact test. The color analysis was conducted with the Student t test (α=.05). Subjectively, the risk of gingival irritation was 66.7% in the extended group and 47.2% in the nonextended group, showing no statistically significant difference (P&gt;.05). However, objectively, the risk of gingival irritation was significantly higher in the extended group (88.9%) compared with the nonextended group (63.9%) (P=.01(95% CI 1.06 to 1.83). Tooth sensitivity intensity was significantly higher in the extended tray group (P&lt;.001), although the design did not significantly influence the risk of tooth sensitivity (P&gt;.05). No significant differences were found between groups regarding color change (P&gt;.05). The use of an extended bleaching tray design increases the risk of gingival irritation and the intensity of tooth sensitivity. Therefore, the nonextended tray is recommended to minimize adverse reactions.</description><identifier>ISSN: 0022-3913</identifier><identifier>ISSN: 1097-6841</identifier><identifier>EISSN: 1097-6841</identifier><identifier>DOI: 10.1016/j.prosdent.2024.09.029</identifier><identifier>PMID: 39562219</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><ispartof>The Journal of prosthetic dentistry, 2024-11</ispartof><rights>2024 The Authors</rights><rights>Copyright © 2024 The Authors. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c1609-c57319c975bdb34a1b84e24b6ac49f6136bb96f2a75dff936f94c65e5344753</cites><orcidid>0000-0002-3500-3039 ; 0000-0002-4956-681X ; 0000-0002-9142-3118 ; 0000-0003-1354-3429</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.prosdent.2024.09.029$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39562219$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Pereira-Lores, Patricia</creatorcontrib><creatorcontrib>Martín-González, Jenifer</creatorcontrib><creatorcontrib>Gancedo-Gancedo, Tania</creatorcontrib><creatorcontrib>Alonso de la Peña, Víctor</creatorcontrib><creatorcontrib>Álvarez-Nóvoa, Pablo</creatorcontrib><creatorcontrib>Varela-Aneiros, Iván</creatorcontrib><creatorcontrib>Abella-Sans, Francesc</creatorcontrib><creatorcontrib>Martín-Biedma, Benjamín</creatorcontrib><creatorcontrib>Castelo-Baz, Pablo</creatorcontrib><title>Does the use of a 3-mm extended tray during an at-home bleaching treatment increase gingival irritation? A randomized clinical trial</title><title>The Journal of prosthetic dentistry</title><addtitle>J Prosthet Dent</addtitle><description>Gingival irritation is a common side effect of at-home bleaching, but how the design of the bleaching tray affects its occurrence is unclear. The purpose of this randomized clinical trial was to determine whether a direct relationship is present between the design of bleaching trays and the risk of gingival irritation during at-home bleaching treatments. This clinical trial was registered at ClinicalTrials.gov. (NCT06371664). Seventy-two participants were randomly assigned to 2 experimental groups: extended bleaching tray (3 mm) and nonextended bleaching tray (1 mm). Over a period of 3 weeks, participants underwent a nightguard dental bleaching treatment (6 to 8 hours) using 16% carbamide peroxide gel. Gingival irritation was evaluated subjectively by participants daily and objectively by clinicians at each visit. Tooth sensitivity was recorded daily using a 5-point numerical scale. Tooth color measurements were also made with a dental spectrophotometer. The risk of gingival irritation and the risk and intensity of tooth sensitivity were analyzed with the Pearson chi squared test and Fisher exact test. The color analysis was conducted with the Student t test (α=.05). Subjectively, the risk of gingival irritation was 66.7% in the extended group and 47.2% in the nonextended group, showing no statistically significant difference (P&gt;.05). However, objectively, the risk of gingival irritation was significantly higher in the extended group (88.9%) compared with the nonextended group (63.9%) (P=.01(95% CI 1.06 to 1.83). Tooth sensitivity intensity was significantly higher in the extended tray group (P&lt;.001), although the design did not significantly influence the risk of tooth sensitivity (P&gt;.05). No significant differences were found between groups regarding color change (P&gt;.05). The use of an extended bleaching tray design increases the risk of gingival irritation and the intensity of tooth sensitivity. Therefore, the nonextended tray is recommended to minimize adverse reactions.</description><issn>0022-3913</issn><issn>1097-6841</issn><issn>1097-6841</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNqFkE1P3DAQhi0Egi3tX0A-cknq76xPLeKjRULi0N4tx56wXiUOtR0EPfPD8Wqh155mNHrmHftB6IySlhKqvm7bxzRnD7G0jDDREt0Spg_QihLdNWot6CFaEcJYwzXlJ-hTzltCyFp29BidcC0VY1Sv0OvVDBmXDeAlA54HbDFvpgnDc4HoweOS7Av2SwrxAduIbWk28wS4H8G6zW5YEtgy1YfgEF3ta8xDnYcnO-KQUii2hDl-wxc42ejnKfytqW4MMbhKlBTs-BkdDXbM8OW9nqJfN9e_L382d_c_bi8v7hpHFdGNkx2n2ulO9r7nwtJ-LYCJXlkn9KAoV32v1cBsJ_0waK4GLZySILkQneSn6HyfWs39WSAXM4XsYBxthHnJhlNO1qwjklZU7VFXJecEg3lMYbLpxVBidv7N1nz4Nzv_hmhT_dfFs_cbSz-B_7f2IbwC3_cA1H8-BUgmuwDRgQ8JXDF-Dv-78QbK55u5</recordid><startdate>20241118</startdate><enddate>20241118</enddate><creator>Pereira-Lores, Patricia</creator><creator>Martín-González, Jenifer</creator><creator>Gancedo-Gancedo, Tania</creator><creator>Alonso de la Peña, Víctor</creator><creator>Álvarez-Nóvoa, Pablo</creator><creator>Varela-Aneiros, Iván</creator><creator>Abella-Sans, Francesc</creator><creator>Martín-Biedma, Benjamín</creator><creator>Castelo-Baz, Pablo</creator><general>Elsevier Inc</general><scope>6I.</scope><scope>AAFTH</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-3500-3039</orcidid><orcidid>https://orcid.org/0000-0002-4956-681X</orcidid><orcidid>https://orcid.org/0000-0002-9142-3118</orcidid><orcidid>https://orcid.org/0000-0003-1354-3429</orcidid></search><sort><creationdate>20241118</creationdate><title>Does the use of a 3-mm extended tray during an at-home bleaching treatment increase gingival irritation? A randomized clinical trial</title><author>Pereira-Lores, Patricia ; Martín-González, Jenifer ; Gancedo-Gancedo, Tania ; Alonso de la Peña, Víctor ; Álvarez-Nóvoa, Pablo ; Varela-Aneiros, Iván ; Abella-Sans, Francesc ; Martín-Biedma, Benjamín ; Castelo-Baz, Pablo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1609-c57319c975bdb34a1b84e24b6ac49f6136bb96f2a75dff936f94c65e5344753</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Pereira-Lores, Patricia</creatorcontrib><creatorcontrib>Martín-González, Jenifer</creatorcontrib><creatorcontrib>Gancedo-Gancedo, Tania</creatorcontrib><creatorcontrib>Alonso de la Peña, Víctor</creatorcontrib><creatorcontrib>Álvarez-Nóvoa, Pablo</creatorcontrib><creatorcontrib>Varela-Aneiros, Iván</creatorcontrib><creatorcontrib>Abella-Sans, Francesc</creatorcontrib><creatorcontrib>Martín-Biedma, Benjamín</creatorcontrib><creatorcontrib>Castelo-Baz, Pablo</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of prosthetic dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Pereira-Lores, Patricia</au><au>Martín-González, Jenifer</au><au>Gancedo-Gancedo, Tania</au><au>Alonso de la Peña, Víctor</au><au>Álvarez-Nóvoa, Pablo</au><au>Varela-Aneiros, Iván</au><au>Abella-Sans, Francesc</au><au>Martín-Biedma, Benjamín</au><au>Castelo-Baz, Pablo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Does the use of a 3-mm extended tray during an at-home bleaching treatment increase gingival irritation? A randomized clinical trial</atitle><jtitle>The Journal of prosthetic dentistry</jtitle><addtitle>J Prosthet Dent</addtitle><date>2024-11-18</date><risdate>2024</risdate><issn>0022-3913</issn><issn>1097-6841</issn><eissn>1097-6841</eissn><abstract>Gingival irritation is a common side effect of at-home bleaching, but how the design of the bleaching tray affects its occurrence is unclear. The purpose of this randomized clinical trial was to determine whether a direct relationship is present between the design of bleaching trays and the risk of gingival irritation during at-home bleaching treatments. This clinical trial was registered at ClinicalTrials.gov. (NCT06371664). Seventy-two participants were randomly assigned to 2 experimental groups: extended bleaching tray (3 mm) and nonextended bleaching tray (1 mm). Over a period of 3 weeks, participants underwent a nightguard dental bleaching treatment (6 to 8 hours) using 16% carbamide peroxide gel. Gingival irritation was evaluated subjectively by participants daily and objectively by clinicians at each visit. Tooth sensitivity was recorded daily using a 5-point numerical scale. Tooth color measurements were also made with a dental spectrophotometer. The risk of gingival irritation and the risk and intensity of tooth sensitivity were analyzed with the Pearson chi squared test and Fisher exact test. The color analysis was conducted with the Student t test (α=.05). Subjectively, the risk of gingival irritation was 66.7% in the extended group and 47.2% in the nonextended group, showing no statistically significant difference (P&gt;.05). However, objectively, the risk of gingival irritation was significantly higher in the extended group (88.9%) compared with the nonextended group (63.9%) (P=.01(95% CI 1.06 to 1.83). Tooth sensitivity intensity was significantly higher in the extended tray group (P&lt;.001), although the design did not significantly influence the risk of tooth sensitivity (P&gt;.05). No significant differences were found between groups regarding color change (P&gt;.05). The use of an extended bleaching tray design increases the risk of gingival irritation and the intensity of tooth sensitivity. Therefore, the nonextended tray is recommended to minimize adverse reactions.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>39562219</pmid><doi>10.1016/j.prosdent.2024.09.029</doi><orcidid>https://orcid.org/0000-0002-3500-3039</orcidid><orcidid>https://orcid.org/0000-0002-4956-681X</orcidid><orcidid>https://orcid.org/0000-0002-9142-3118</orcidid><orcidid>https://orcid.org/0000-0003-1354-3429</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0022-3913
ispartof The Journal of prosthetic dentistry, 2024-11
issn 0022-3913
1097-6841
1097-6841
language eng
recordid cdi_proquest_miscellaneous_3130827051
source Elsevier ScienceDirect Journals Complete
title Does the use of a 3-mm extended tray during an at-home bleaching treatment increase gingival irritation? A randomized clinical trial
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T09%3A21%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Does%20the%20use%20of%20a%203-mm%20extended%20tray%20during%20an%20at-home%20bleaching%20treatment%20increase%20gingival%20irritation?%20A%20randomized%20clinical%20trial&rft.jtitle=The%20Journal%20of%20prosthetic%20dentistry&rft.au=Pereira-Lores,%20Patricia&rft.date=2024-11-18&rft.issn=0022-3913&rft.eissn=1097-6841&rft_id=info:doi/10.1016/j.prosdent.2024.09.029&rft_dat=%3Cproquest_cross%3E3130827051%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3130827051&rft_id=info:pmid/39562219&rft_els_id=S0022391324006905&rfr_iscdi=true