The Potential of Sound Analysis to Reveal Hemodynamic Conditions of Arteriovenous Fistulae for Hemodialysis

Arteriovenous fistula (AVF), the preferred vascular access for hemodialysis, is associated with high failure rate. The aim of this study was to investigate the potential of AVF sound auscultation in providing quantitative information on AVF hemodynamic conditions. This single-center prospective stud...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Annals of biomedical engineering 2024-11
Hauptverfasser: Poloni, Sofia, Soliveri, Luca, Caroli, Anna, Remuzzi, Andrea, Bozzetto, Michela
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title Annals of biomedical engineering
container_volume
creator Poloni, Sofia
Soliveri, Luca
Caroli, Anna
Remuzzi, Andrea
Bozzetto, Michela
description Arteriovenous fistula (AVF), the preferred vascular access for hemodialysis, is associated with high failure rate. The aim of this study was to investigate the potential of AVF sound auscultation in providing quantitative information on AVF hemodynamic conditions. This single-center prospective study involved six patients with native radio-cephalic AVFs who underwent multiple follow-up visits. Doppler Ultrasound blood flow volume (BFV) assessment and electronic stethoscope-based sound recordings were performed during each visit, whereas MRIs were acquired 3 days, 3 weeks and 1 year after surgery. Computational fluid dynamic (CFD) simulations were performed on patient-specific MRI-derived geometrical models. Higher values of median peak amplitudes ratios (high-low peak ratio-HLPR) were found to be associated with complex blood flow and velocity streamlines recirculation at systolic peak, and corresponding extended regions of high oscillatory shear index (OSI). On the contrary, lower values of HLPR were associated with laminar flow pattern and low values of OSI. Significant differences were observed in HLPR between subgroups with extended or limited areas with OSI > 0.1 (0.67 vs 0.31, respectively). Significant relationships were found between AVF sound intensity and brachial BFV (slope = 0.103, p 
doi_str_mv 10.1007/s10439-024-03638-2
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3123367907</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3123367907</sourcerecordid><originalsourceid>FETCH-LOGICAL-c228t-418a9f20789b48d44d9fa09715def6549d941300699fdc5309e3a931feec5fd73</originalsourceid><addsrcrecordid>eNo9kMtOwzAQRS0EouXxAyyQl2wC40eceFlVQJEqgaCsLTceC0MSQ5xU6t_TEmA1i3vP1egQcsHgmgEUN4mBFDoDLjMQSpQZPyBTlhci06pUh2QKoCFTWskJOUnpHYCxUuTHZCK0LHMl-ZR8rN6QPsUe2z7YmkZPX-LQOjprbb1NIdE-0mfc4C5bYBPdtrVNqOg8ti70IbZpj8y6HrsQN9jGIdG7kPqhtkh97EYojFtn5MjbOuH57z0lr3e3q_kiWz7eP8xny6zivOwzyUqrPYei1GtZOimd9hZ0wXKHXuVSOy2ZAFBae1flAjQKqwXziFXuXSFOydW4-9nFrwFTb5qQKqxr2-LuQSMYF0IVGvZVPlarLqbUoTefXWhstzUMzF6yGSWbnWTzI9nwHXT5uz-sG3T_yJ9V8Q02bnix</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3123367907</pqid></control><display><type>article</type><title>The Potential of Sound Analysis to Reveal Hemodynamic Conditions of Arteriovenous Fistulae for Hemodialysis</title><source>SpringerLink Journals - AutoHoldings</source><creator>Poloni, Sofia ; Soliveri, Luca ; Caroli, Anna ; Remuzzi, Andrea ; Bozzetto, Michela</creator><creatorcontrib>Poloni, Sofia ; Soliveri, Luca ; Caroli, Anna ; Remuzzi, Andrea ; Bozzetto, Michela</creatorcontrib><description>Arteriovenous fistula (AVF), the preferred vascular access for hemodialysis, is associated with high failure rate. The aim of this study was to investigate the potential of AVF sound auscultation in providing quantitative information on AVF hemodynamic conditions. This single-center prospective study involved six patients with native radio-cephalic AVFs who underwent multiple follow-up visits. Doppler Ultrasound blood flow volume (BFV) assessment and electronic stethoscope-based sound recordings were performed during each visit, whereas MRIs were acquired 3 days, 3 weeks and 1 year after surgery. Computational fluid dynamic (CFD) simulations were performed on patient-specific MRI-derived geometrical models. Higher values of median peak amplitudes ratios (high-low peak ratio-HLPR) were found to be associated with complex blood flow and velocity streamlines recirculation at systolic peak, and corresponding extended regions of high oscillatory shear index (OSI). On the contrary, lower values of HLPR were associated with laminar flow pattern and low values of OSI. Significant differences were observed in HLPR between subgroups with extended or limited areas with OSI &gt; 0.1 (0.67 vs 0.31, respectively). Significant relationships were found between AVF sound intensity and brachial BFV (slope = 0.103, p &lt; 0.01) as well as between longitudinal changes in brachial BFV and HLPR (slope = - 0.001, p &lt; 0.01). Our results show that AVF sound can be exploited to extract fundamental information on AVF hemodynamic conditions, providing indication of the presence of complex hemodynamic and adequate BFV to perform hemodialysis. Sound analysis has therefore the potential to improve clinical AVF surveillance and to ameliorate outcome.</description><identifier>ISSN: 0090-6964</identifier><identifier>ISSN: 1573-9686</identifier><identifier>EISSN: 1573-9686</identifier><identifier>DOI: 10.1007/s10439-024-03638-2</identifier><identifier>PMID: 39485642</identifier><language>eng</language><publisher>United States</publisher><ispartof>Annals of biomedical engineering, 2024-11</ispartof><rights>2024. The Author(s).</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c228t-418a9f20789b48d44d9fa09715def6549d941300699fdc5309e3a931feec5fd73</cites><orcidid>0000-0002-4301-8927 ; 0000-0002-2045-5550 ; 0000-0002-9402-9925 ; 0000-0002-8096-2925 ; 0000-0002-4130-4663</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785,27925,27926</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39485642$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Poloni, Sofia</creatorcontrib><creatorcontrib>Soliveri, Luca</creatorcontrib><creatorcontrib>Caroli, Anna</creatorcontrib><creatorcontrib>Remuzzi, Andrea</creatorcontrib><creatorcontrib>Bozzetto, Michela</creatorcontrib><title>The Potential of Sound Analysis to Reveal Hemodynamic Conditions of Arteriovenous Fistulae for Hemodialysis</title><title>Annals of biomedical engineering</title><addtitle>Ann Biomed Eng</addtitle><description>Arteriovenous fistula (AVF), the preferred vascular access for hemodialysis, is associated with high failure rate. The aim of this study was to investigate the potential of AVF sound auscultation in providing quantitative information on AVF hemodynamic conditions. This single-center prospective study involved six patients with native radio-cephalic AVFs who underwent multiple follow-up visits. Doppler Ultrasound blood flow volume (BFV) assessment and electronic stethoscope-based sound recordings were performed during each visit, whereas MRIs were acquired 3 days, 3 weeks and 1 year after surgery. Computational fluid dynamic (CFD) simulations were performed on patient-specific MRI-derived geometrical models. Higher values of median peak amplitudes ratios (high-low peak ratio-HLPR) were found to be associated with complex blood flow and velocity streamlines recirculation at systolic peak, and corresponding extended regions of high oscillatory shear index (OSI). On the contrary, lower values of HLPR were associated with laminar flow pattern and low values of OSI. Significant differences were observed in HLPR between subgroups with extended or limited areas with OSI &gt; 0.1 (0.67 vs 0.31, respectively). Significant relationships were found between AVF sound intensity and brachial BFV (slope = 0.103, p &lt; 0.01) as well as between longitudinal changes in brachial BFV and HLPR (slope = - 0.001, p &lt; 0.01). Our results show that AVF sound can be exploited to extract fundamental information on AVF hemodynamic conditions, providing indication of the presence of complex hemodynamic and adequate BFV to perform hemodialysis. Sound analysis has therefore the potential to improve clinical AVF surveillance and to ameliorate outcome.</description><issn>0090-6964</issn><issn>1573-9686</issn><issn>1573-9686</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNo9kMtOwzAQRS0EouXxAyyQl2wC40eceFlVQJEqgaCsLTceC0MSQ5xU6t_TEmA1i3vP1egQcsHgmgEUN4mBFDoDLjMQSpQZPyBTlhci06pUh2QKoCFTWskJOUnpHYCxUuTHZCK0LHMl-ZR8rN6QPsUe2z7YmkZPX-LQOjprbb1NIdE-0mfc4C5bYBPdtrVNqOg8ti70IbZpj8y6HrsQN9jGIdG7kPqhtkh97EYojFtn5MjbOuH57z0lr3e3q_kiWz7eP8xny6zivOwzyUqrPYei1GtZOimd9hZ0wXKHXuVSOy2ZAFBae1flAjQKqwXziFXuXSFOydW4-9nFrwFTb5qQKqxr2-LuQSMYF0IVGvZVPlarLqbUoTefXWhstzUMzF6yGSWbnWTzI9nwHXT5uz-sG3T_yJ9V8Q02bnix</recordid><startdate>20241101</startdate><enddate>20241101</enddate><creator>Poloni, Sofia</creator><creator>Soliveri, Luca</creator><creator>Caroli, Anna</creator><creator>Remuzzi, Andrea</creator><creator>Bozzetto, Michela</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-4301-8927</orcidid><orcidid>https://orcid.org/0000-0002-2045-5550</orcidid><orcidid>https://orcid.org/0000-0002-9402-9925</orcidid><orcidid>https://orcid.org/0000-0002-8096-2925</orcidid><orcidid>https://orcid.org/0000-0002-4130-4663</orcidid></search><sort><creationdate>20241101</creationdate><title>The Potential of Sound Analysis to Reveal Hemodynamic Conditions of Arteriovenous Fistulae for Hemodialysis</title><author>Poloni, Sofia ; Soliveri, Luca ; Caroli, Anna ; Remuzzi, Andrea ; Bozzetto, Michela</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c228t-418a9f20789b48d44d9fa09715def6549d941300699fdc5309e3a931feec5fd73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Poloni, Sofia</creatorcontrib><creatorcontrib>Soliveri, Luca</creatorcontrib><creatorcontrib>Caroli, Anna</creatorcontrib><creatorcontrib>Remuzzi, Andrea</creatorcontrib><creatorcontrib>Bozzetto, Michela</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Annals of biomedical engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Poloni, Sofia</au><au>Soliveri, Luca</au><au>Caroli, Anna</au><au>Remuzzi, Andrea</au><au>Bozzetto, Michela</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The Potential of Sound Analysis to Reveal Hemodynamic Conditions of Arteriovenous Fistulae for Hemodialysis</atitle><jtitle>Annals of biomedical engineering</jtitle><addtitle>Ann Biomed Eng</addtitle><date>2024-11-01</date><risdate>2024</risdate><issn>0090-6964</issn><issn>1573-9686</issn><eissn>1573-9686</eissn><abstract>Arteriovenous fistula (AVF), the preferred vascular access for hemodialysis, is associated with high failure rate. The aim of this study was to investigate the potential of AVF sound auscultation in providing quantitative information on AVF hemodynamic conditions. This single-center prospective study involved six patients with native radio-cephalic AVFs who underwent multiple follow-up visits. Doppler Ultrasound blood flow volume (BFV) assessment and electronic stethoscope-based sound recordings were performed during each visit, whereas MRIs were acquired 3 days, 3 weeks and 1 year after surgery. Computational fluid dynamic (CFD) simulations were performed on patient-specific MRI-derived geometrical models. Higher values of median peak amplitudes ratios (high-low peak ratio-HLPR) were found to be associated with complex blood flow and velocity streamlines recirculation at systolic peak, and corresponding extended regions of high oscillatory shear index (OSI). On the contrary, lower values of HLPR were associated with laminar flow pattern and low values of OSI. Significant differences were observed in HLPR between subgroups with extended or limited areas with OSI &gt; 0.1 (0.67 vs 0.31, respectively). Significant relationships were found between AVF sound intensity and brachial BFV (slope = 0.103, p &lt; 0.01) as well as between longitudinal changes in brachial BFV and HLPR (slope = - 0.001, p &lt; 0.01). Our results show that AVF sound can be exploited to extract fundamental information on AVF hemodynamic conditions, providing indication of the presence of complex hemodynamic and adequate BFV to perform hemodialysis. Sound analysis has therefore the potential to improve clinical AVF surveillance and to ameliorate outcome.</abstract><cop>United States</cop><pmid>39485642</pmid><doi>10.1007/s10439-024-03638-2</doi><orcidid>https://orcid.org/0000-0002-4301-8927</orcidid><orcidid>https://orcid.org/0000-0002-2045-5550</orcidid><orcidid>https://orcid.org/0000-0002-9402-9925</orcidid><orcidid>https://orcid.org/0000-0002-8096-2925</orcidid><orcidid>https://orcid.org/0000-0002-4130-4663</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0090-6964
ispartof Annals of biomedical engineering, 2024-11
issn 0090-6964
1573-9686
1573-9686
language eng
recordid cdi_proquest_miscellaneous_3123367907
source SpringerLink Journals - AutoHoldings
title The Potential of Sound Analysis to Reveal Hemodynamic Conditions of Arteriovenous Fistulae for Hemodialysis
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-18T14%3A38%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20Potential%20of%20Sound%20Analysis%20to%20Reveal%20Hemodynamic%20Conditions%20of%20Arteriovenous%20Fistulae%20for%20Hemodialysis&rft.jtitle=Annals%20of%20biomedical%20engineering&rft.au=Poloni,%20Sofia&rft.date=2024-11-01&rft.issn=0090-6964&rft.eissn=1573-9686&rft_id=info:doi/10.1007/s10439-024-03638-2&rft_dat=%3Cproquest_cross%3E3123367907%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3123367907&rft_id=info:pmid/39485642&rfr_iscdi=true