Sensitivity improvement of a deuterium-deuterium neutron generator based in vivo neutron activation analysis (IVNAA) system

Our lab has been developing a deuterium-deuterium (DD) neutron generator-based neutron activation analysis (NAA) system to quantify metals and elements in the human body in vivo. The system has been used to quantify metals such as manganese, aluminum, sodium in bones of a living human. The technolog...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physical and engineering sciences in medicine 2024-10
Hauptverfasser: Yue, Song, Tabbassum, Sana, Jaye, Elizabeth Helen, Anderson, Cheryl A M, Nie, Linda H
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title Physical and engineering sciences in medicine
container_volume
creator Yue, Song
Tabbassum, Sana
Jaye, Elizabeth Helen
Anderson, Cheryl A M
Nie, Linda H
description Our lab has been developing a deuterium-deuterium (DD) neutron generator-based neutron activation analysis (NAA) system to quantify metals and elements in the human body in vivo. The system has been used to quantify metals such as manganese, aluminum, sodium in bones of a living human. The technology provides a useful way to assess metal exposure and to estimate elemental deposition, storage and biokinetics. It has great potential to be applied in the occupational and environmental health fields to study the association of metal exposure and various health outcomes, as well as in the nutrition field to study the intake of essential elements and human health. However, the relatively low sensitivity of the system has greatly limited its applications. Neutron moderation plays an important role in designing an IVNAA facility, as it affects thermal neutron flux in irradiation cave and radiation exposure to the human subject. This study aims to develop a novel thermal neutron enhancement method to improve the sensitivity of the in vivo neutron activation analysis (IVNAA) system for elemental measurement but still maintain radiation dose. Utilizing a compact DD neutron source, we propose a new and practical moderator design that combines high density polyethylene with heavy water to enhance thermal neutrons by reducing thermal neutron absorption. All material dimensions are calculated by PHITS, a general-purpose Monte Carlo simulation program. The improvement of the new design predicted by the Monte Carlo simulation for the quantification of one of the elements, manganese was verified by experimental irradiation of manganese-doped bone equivalent phantoms. For the same radiation dose, a 67.9% thermal neutron flux enhancement is reached. With only 4.2% increase of radiation dose, the simulated thermal neutron flux and activation can be further increased by 84.2%. A 100% thermal neutron enhancement ratio is also achievable with a 20% dose increase. The experimental results clearly show higher manganese activation gamma ray counts for each specific phantom, with a significantly reduced minimum detection limit. Additionally, the photon dose was suppressed. The thermal neutron enhancement method can increase the number of useful neutrons significantly but maintain the radiation dose. This greatly decreased the detection limit of the system for elemental quantification at an acceptable dose, which will broadly expand the application of the technology in research and cl
doi_str_mv 10.1007/s13246-024-01487-w
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3120060809</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3120060809</sourcerecordid><originalsourceid>FETCH-LOGICAL-c184t-8cfa847919ec15e944c64541203259d3a735546f6daeda2bc2da450e7b274b933</originalsourceid><addsrcrecordid>eNo9kEtPwzAQhC0Eoqj0D3BAPpZDwG8nx6riUamCA4-r5SQbZNQkxXZaRfx5Ulp62pF2ZrT7IXRFyS0lRN8FyplQCWEiIVSkOtmeoAumFEuE5vr0qFk2QpMQvgghTFKqlTxHI54JoTiRF-jnFZrgotu42GNXr327gRqaiNsKW1xCF8G7rk6OCjeD8m2DP6EBb2PrcW4DlNg1eOM27XFvi6HVRreTjV31wQU8XXw8z2Y3OPQhQn2Jziq7CjA5zDF6f7h_mz8ly5fHxXy2TAqaipikRWVToTOaQUElDKcXSkhBGeFMZiW3mkspVKVKC6VlecFKKyQBnTMt8ozzMZrue4fvvjsI0dQuFLBa2QbaLhg-VBFFUpINVra3Fr4NwUNl1t7V1veGErPjbvbczcDd_HE32yF0fejv8hrKY-SfMv8FtlCALA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3120060809</pqid></control><display><type>article</type><title>Sensitivity improvement of a deuterium-deuterium neutron generator based in vivo neutron activation analysis (IVNAA) system</title><source>SpringerNature Journals</source><creator>Yue, Song ; Tabbassum, Sana ; Jaye, Elizabeth Helen ; Anderson, Cheryl A M ; Nie, Linda H</creator><creatorcontrib>Yue, Song ; Tabbassum, Sana ; Jaye, Elizabeth Helen ; Anderson, Cheryl A M ; Nie, Linda H</creatorcontrib><description>Our lab has been developing a deuterium-deuterium (DD) neutron generator-based neutron activation analysis (NAA) system to quantify metals and elements in the human body in vivo. The system has been used to quantify metals such as manganese, aluminum, sodium in bones of a living human. The technology provides a useful way to assess metal exposure and to estimate elemental deposition, storage and biokinetics. It has great potential to be applied in the occupational and environmental health fields to study the association of metal exposure and various health outcomes, as well as in the nutrition field to study the intake of essential elements and human health. However, the relatively low sensitivity of the system has greatly limited its applications. Neutron moderation plays an important role in designing an IVNAA facility, as it affects thermal neutron flux in irradiation cave and radiation exposure to the human subject. This study aims to develop a novel thermal neutron enhancement method to improve the sensitivity of the in vivo neutron activation analysis (IVNAA) system for elemental measurement but still maintain radiation dose. Utilizing a compact DD neutron source, we propose a new and practical moderator design that combines high density polyethylene with heavy water to enhance thermal neutrons by reducing thermal neutron absorption. All material dimensions are calculated by PHITS, a general-purpose Monte Carlo simulation program. The improvement of the new design predicted by the Monte Carlo simulation for the quantification of one of the elements, manganese was verified by experimental irradiation of manganese-doped bone equivalent phantoms. For the same radiation dose, a 67.9% thermal neutron flux enhancement is reached. With only 4.2% increase of radiation dose, the simulated thermal neutron flux and activation can be further increased by 84.2%. A 100% thermal neutron enhancement ratio is also achievable with a 20% dose increase. The experimental results clearly show higher manganese activation gamma ray counts for each specific phantom, with a significantly reduced minimum detection limit. Additionally, the photon dose was suppressed. The thermal neutron enhancement method can increase the number of useful neutrons significantly but maintain the radiation dose. This greatly decreased the detection limit of the system for elemental quantification at an acceptable dose, which will broadly expand the application of the technology in research and clinical use. The method can also be applied to other neutron medical applications, including neutron imaging and radiotherapy.</description><identifier>ISSN: 2662-4729</identifier><identifier>ISSN: 2662-4737</identifier><identifier>EISSN: 2662-4737</identifier><identifier>DOI: 10.1007/s13246-024-01487-w</identifier><identifier>PMID: 39446305</identifier><language>eng</language><publisher>Switzerland</publisher><ispartof>Physical and engineering sciences in medicine, 2024-10</ispartof><rights>2024. Australasian College of Physical Scientists and Engineers in Medicine.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c184t-8cfa847919ec15e944c64541203259d3a735546f6daeda2bc2da450e7b274b933</cites><orcidid>0009-0004-2500-1277</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,782,786,27931,27932</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39446305$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Yue, Song</creatorcontrib><creatorcontrib>Tabbassum, Sana</creatorcontrib><creatorcontrib>Jaye, Elizabeth Helen</creatorcontrib><creatorcontrib>Anderson, Cheryl A M</creatorcontrib><creatorcontrib>Nie, Linda H</creatorcontrib><title>Sensitivity improvement of a deuterium-deuterium neutron generator based in vivo neutron activation analysis (IVNAA) system</title><title>Physical and engineering sciences in medicine</title><addtitle>Phys Eng Sci Med</addtitle><description>Our lab has been developing a deuterium-deuterium (DD) neutron generator-based neutron activation analysis (NAA) system to quantify metals and elements in the human body in vivo. The system has been used to quantify metals such as manganese, aluminum, sodium in bones of a living human. The technology provides a useful way to assess metal exposure and to estimate elemental deposition, storage and biokinetics. It has great potential to be applied in the occupational and environmental health fields to study the association of metal exposure and various health outcomes, as well as in the nutrition field to study the intake of essential elements and human health. However, the relatively low sensitivity of the system has greatly limited its applications. Neutron moderation plays an important role in designing an IVNAA facility, as it affects thermal neutron flux in irradiation cave and radiation exposure to the human subject. This study aims to develop a novel thermal neutron enhancement method to improve the sensitivity of the in vivo neutron activation analysis (IVNAA) system for elemental measurement but still maintain radiation dose. Utilizing a compact DD neutron source, we propose a new and practical moderator design that combines high density polyethylene with heavy water to enhance thermal neutrons by reducing thermal neutron absorption. All material dimensions are calculated by PHITS, a general-purpose Monte Carlo simulation program. The improvement of the new design predicted by the Monte Carlo simulation for the quantification of one of the elements, manganese was verified by experimental irradiation of manganese-doped bone equivalent phantoms. For the same radiation dose, a 67.9% thermal neutron flux enhancement is reached. With only 4.2% increase of radiation dose, the simulated thermal neutron flux and activation can be further increased by 84.2%. A 100% thermal neutron enhancement ratio is also achievable with a 20% dose increase. The experimental results clearly show higher manganese activation gamma ray counts for each specific phantom, with a significantly reduced minimum detection limit. Additionally, the photon dose was suppressed. The thermal neutron enhancement method can increase the number of useful neutrons significantly but maintain the radiation dose. This greatly decreased the detection limit of the system for elemental quantification at an acceptable dose, which will broadly expand the application of the technology in research and clinical use. The method can also be applied to other neutron medical applications, including neutron imaging and radiotherapy.</description><issn>2662-4729</issn><issn>2662-4737</issn><issn>2662-4737</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNo9kEtPwzAQhC0Eoqj0D3BAPpZDwG8nx6riUamCA4-r5SQbZNQkxXZaRfx5Ulp62pF2ZrT7IXRFyS0lRN8FyplQCWEiIVSkOtmeoAumFEuE5vr0qFk2QpMQvgghTFKqlTxHI54JoTiRF-jnFZrgotu42GNXr327gRqaiNsKW1xCF8G7rk6OCjeD8m2DP6EBb2PrcW4DlNg1eOM27XFvi6HVRreTjV31wQU8XXw8z2Y3OPQhQn2Jziq7CjA5zDF6f7h_mz8ly5fHxXy2TAqaipikRWVToTOaQUElDKcXSkhBGeFMZiW3mkspVKVKC6VlecFKKyQBnTMt8ozzMZrue4fvvjsI0dQuFLBa2QbaLhg-VBFFUpINVra3Fr4NwUNl1t7V1veGErPjbvbczcDd_HE32yF0fejv8hrKY-SfMv8FtlCALA</recordid><startdate>20241024</startdate><enddate>20241024</enddate><creator>Yue, Song</creator><creator>Tabbassum, Sana</creator><creator>Jaye, Elizabeth Helen</creator><creator>Anderson, Cheryl A M</creator><creator>Nie, Linda H</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0009-0004-2500-1277</orcidid></search><sort><creationdate>20241024</creationdate><title>Sensitivity improvement of a deuterium-deuterium neutron generator based in vivo neutron activation analysis (IVNAA) system</title><author>Yue, Song ; Tabbassum, Sana ; Jaye, Elizabeth Helen ; Anderson, Cheryl A M ; Nie, Linda H</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c184t-8cfa847919ec15e944c64541203259d3a735546f6daeda2bc2da450e7b274b933</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yue, Song</creatorcontrib><creatorcontrib>Tabbassum, Sana</creatorcontrib><creatorcontrib>Jaye, Elizabeth Helen</creatorcontrib><creatorcontrib>Anderson, Cheryl A M</creatorcontrib><creatorcontrib>Nie, Linda H</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Physical and engineering sciences in medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yue, Song</au><au>Tabbassum, Sana</au><au>Jaye, Elizabeth Helen</au><au>Anderson, Cheryl A M</au><au>Nie, Linda H</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Sensitivity improvement of a deuterium-deuterium neutron generator based in vivo neutron activation analysis (IVNAA) system</atitle><jtitle>Physical and engineering sciences in medicine</jtitle><addtitle>Phys Eng Sci Med</addtitle><date>2024-10-24</date><risdate>2024</risdate><issn>2662-4729</issn><issn>2662-4737</issn><eissn>2662-4737</eissn><abstract>Our lab has been developing a deuterium-deuterium (DD) neutron generator-based neutron activation analysis (NAA) system to quantify metals and elements in the human body in vivo. The system has been used to quantify metals such as manganese, aluminum, sodium in bones of a living human. The technology provides a useful way to assess metal exposure and to estimate elemental deposition, storage and biokinetics. It has great potential to be applied in the occupational and environmental health fields to study the association of metal exposure and various health outcomes, as well as in the nutrition field to study the intake of essential elements and human health. However, the relatively low sensitivity of the system has greatly limited its applications. Neutron moderation plays an important role in designing an IVNAA facility, as it affects thermal neutron flux in irradiation cave and radiation exposure to the human subject. This study aims to develop a novel thermal neutron enhancement method to improve the sensitivity of the in vivo neutron activation analysis (IVNAA) system for elemental measurement but still maintain radiation dose. Utilizing a compact DD neutron source, we propose a new and practical moderator design that combines high density polyethylene with heavy water to enhance thermal neutrons by reducing thermal neutron absorption. All material dimensions are calculated by PHITS, a general-purpose Monte Carlo simulation program. The improvement of the new design predicted by the Monte Carlo simulation for the quantification of one of the elements, manganese was verified by experimental irradiation of manganese-doped bone equivalent phantoms. For the same radiation dose, a 67.9% thermal neutron flux enhancement is reached. With only 4.2% increase of radiation dose, the simulated thermal neutron flux and activation can be further increased by 84.2%. A 100% thermal neutron enhancement ratio is also achievable with a 20% dose increase. The experimental results clearly show higher manganese activation gamma ray counts for each specific phantom, with a significantly reduced minimum detection limit. Additionally, the photon dose was suppressed. The thermal neutron enhancement method can increase the number of useful neutrons significantly but maintain the radiation dose. This greatly decreased the detection limit of the system for elemental quantification at an acceptable dose, which will broadly expand the application of the technology in research and clinical use. The method can also be applied to other neutron medical applications, including neutron imaging and radiotherapy.</abstract><cop>Switzerland</cop><pmid>39446305</pmid><doi>10.1007/s13246-024-01487-w</doi><orcidid>https://orcid.org/0009-0004-2500-1277</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 2662-4729
ispartof Physical and engineering sciences in medicine, 2024-10
issn 2662-4729
2662-4737
2662-4737
language eng
recordid cdi_proquest_miscellaneous_3120060809
source SpringerNature Journals
title Sensitivity improvement of a deuterium-deuterium neutron generator based in vivo neutron activation analysis (IVNAA) system
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-04T18%3A49%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Sensitivity%20improvement%20of%20a%20deuterium-deuterium%20neutron%20generator%20based%20in%20vivo%20neutron%20activation%20analysis%20(IVNAA)%20system&rft.jtitle=Physical%20and%20engineering%20sciences%20in%20medicine&rft.au=Yue,%20Song&rft.date=2024-10-24&rft.issn=2662-4729&rft.eissn=2662-4737&rft_id=info:doi/10.1007/s13246-024-01487-w&rft_dat=%3Cproquest_cross%3E3120060809%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3120060809&rft_id=info:pmid/39446305&rfr_iscdi=true