Correlation of radiological parameters with functional outcomes post fixation with proximal humerus locking plates

Purpose Proximal humerus fractures account for 4–5% of all fractures in adults and affect females more than males. With the advent of special locking plates, the treatment trend has shifted more towards a surgical approach. These methods have produced good results but very high complications rates h...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International orthopaedics 2024-12, Vol.48 (12), p.3207-3216
Hauptverfasser: Mathur, Bhavya, Suriyakumar, Sundar, Manickam, Karthikeyan, Sameer, Mohamed, Harshvardhan, J K Giriraj
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3216
container_issue 12
container_start_page 3207
container_title International orthopaedics
container_volume 48
creator Mathur, Bhavya
Suriyakumar, Sundar
Manickam, Karthikeyan
Sameer, Mohamed
Harshvardhan, J K Giriraj
description Purpose Proximal humerus fractures account for 4–5% of all fractures in adults and affect females more than males. With the advent of special locking plates, the treatment trend has shifted more towards a surgical approach. These methods have produced good results but very high complications rates have been reported in the literature. This study was undertaken to analyse the radiological parameters which reflect towards a favourable long term functional outcome in order to advance the surgical fixation skills for managing fractures of the proximal part of the humerus. Materials and methods 83 study participants with proximal humerus fracture fixed using proximal humerus locking plates were retrospectively analysed. The radiological parameters studied were neck shaft angle, head shaft angle, head diameter, head height, greater tuberosity to articular surface distance and reduction of the medial hinge with or without placement of calcar screw. The functional parameters assessed were the Constant Murley Score and range of movements of the shoulder joint. The patients were not followed further for the purpose of the study. Results The mean Constant Murley Score for the participants was 80.75 ± 8.09 (range 60–90). The participants with good to excellent CM Score had a significantly higher neck shaft angle (107.47 ± 9.74 v/s 124.16 ± 10.68) and (-0.28 ± 0.85 v/s 2.37 ± 2.28), head shaft angle (23.09 ± 4.82 v/s 31.76 ± 7.76), head diameter (40.08 ± 8.63 v/s 45.15 ± 4.73), head height (18.77 ± 1.96 v/s 20.69 ± 2.76) and greater tuberosity to articular surface distance (-0.28±0.85 v/s 2.37±2.28) as compared to the patients with satisfactory and worse CM Score. The patients with a higher neck shaft angle and a maintained subacromial space had a better range of shoulder abduction. A higher rate of valgus collapse was seen with an inadequate medial hinge reduction. Conclusion The radiological parameters which can predict towards a good functional outcome are a higher neck shaft angle and head shaft angle, a larger head diameter and head height, a superior position of the greater tuberosity in relation to the articular surface and a good medial hinge reduction.
doi_str_mv 10.1007/s00264-024-06324-z
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3111206932</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3111206932</sourcerecordid><originalsourceid>FETCH-LOGICAL-c228t-f1fbf5dbf775f943cc004ff82aa22dfc3f0bdbd2970892b4d275e7101ce17a5b3</originalsourceid><addsrcrecordid>eNp9kMtOxCAUhonROOPoC7gwLN1UubSlLM3EWzKJG10TSmEGbUuFEnWeXmaqLl1wWJzv_HA-AM4xusIIseuAECnzDJF0Sprq9gDMcU5JVmBeHII5ojnOSMmLGTgJ4RUhzMoKH4MZ5TRnvGJz4JfOe93K0boeOgO9bKxr3doq2cJBetnpUfsAP-y4gSb2agemloujcp0OcHBhhMZ-Tgl7bPDu03YJ2sRO-xhg69Sb7ddwSO_ocAqOjGyDPvu5F-Dl7vZ5-ZCtnu4flzerTBFSjZnBpjZFUxvGCsNzqhRCuTEVkZKQxihqUN3UDeEMVZzUeUNYoRlGWGnMZFHTBbicctN_3qMOo-hsULptZa9dDIJijAkqOSUJJROqvAvBayMGnzbwXwIjsXMtJtciuRZ712Kbhi5-8mPd6eZv5FduAugEhNTq19qLVxd9shf-i_0Gr7eOjg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3111206932</pqid></control><display><type>article</type><title>Correlation of radiological parameters with functional outcomes post fixation with proximal humerus locking plates</title><source>SpringerNature Journals</source><creator>Mathur, Bhavya ; Suriyakumar, Sundar ; Manickam, Karthikeyan ; Sameer, Mohamed ; Harshvardhan, J K Giriraj</creator><creatorcontrib>Mathur, Bhavya ; Suriyakumar, Sundar ; Manickam, Karthikeyan ; Sameer, Mohamed ; Harshvardhan, J K Giriraj</creatorcontrib><description>Purpose Proximal humerus fractures account for 4–5% of all fractures in adults and affect females more than males. With the advent of special locking plates, the treatment trend has shifted more towards a surgical approach. These methods have produced good results but very high complications rates have been reported in the literature. This study was undertaken to analyse the radiological parameters which reflect towards a favourable long term functional outcome in order to advance the surgical fixation skills for managing fractures of the proximal part of the humerus. Materials and methods 83 study participants with proximal humerus fracture fixed using proximal humerus locking plates were retrospectively analysed. The radiological parameters studied were neck shaft angle, head shaft angle, head diameter, head height, greater tuberosity to articular surface distance and reduction of the medial hinge with or without placement of calcar screw. The functional parameters assessed were the Constant Murley Score and range of movements of the shoulder joint. The patients were not followed further for the purpose of the study. Results The mean Constant Murley Score for the participants was 80.75 ± 8.09 (range 60–90). The participants with good to excellent CM Score had a significantly higher neck shaft angle (107.47 ± 9.74 v/s 124.16 ± 10.68) and (-0.28 ± 0.85 v/s 2.37 ± 2.28), head shaft angle (23.09 ± 4.82 v/s 31.76 ± 7.76), head diameter (40.08 ± 8.63 v/s 45.15 ± 4.73), head height (18.77 ± 1.96 v/s 20.69 ± 2.76) and greater tuberosity to articular surface distance (-0.28±0.85 v/s 2.37±2.28) as compared to the patients with satisfactory and worse CM Score. The patients with a higher neck shaft angle and a maintained subacromial space had a better range of shoulder abduction. A higher rate of valgus collapse was seen with an inadequate medial hinge reduction. Conclusion The radiological parameters which can predict towards a good functional outcome are a higher neck shaft angle and head shaft angle, a larger head diameter and head height, a superior position of the greater tuberosity in relation to the articular surface and a good medial hinge reduction.</description><identifier>ISSN: 0341-2695</identifier><identifier>ISSN: 1432-5195</identifier><identifier>EISSN: 1432-5195</identifier><identifier>DOI: 10.1007/s00264-024-06324-z</identifier><identifier>PMID: 39347987</identifier><language>eng</language><publisher>Berlin/Heidelberg: Springer Berlin Heidelberg</publisher><subject>Medicine ; Medicine &amp; Public Health ; Original Paper ; Orthopedics</subject><ispartof>International orthopaedics, 2024-12, Vol.48 (12), p.3207-3216</ispartof><rights>The Author(s) under exclusive licence to SICOT aisbl 2024. Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.</rights><rights>2024. The Author(s) under exclusive licence to SICOT aisbl.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c228t-f1fbf5dbf775f943cc004ff82aa22dfc3f0bdbd2970892b4d275e7101ce17a5b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s00264-024-06324-z$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s00264-024-06324-z$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,41488,42557,51319</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39347987$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Mathur, Bhavya</creatorcontrib><creatorcontrib>Suriyakumar, Sundar</creatorcontrib><creatorcontrib>Manickam, Karthikeyan</creatorcontrib><creatorcontrib>Sameer, Mohamed</creatorcontrib><creatorcontrib>Harshvardhan, J K Giriraj</creatorcontrib><title>Correlation of radiological parameters with functional outcomes post fixation with proximal humerus locking plates</title><title>International orthopaedics</title><addtitle>International Orthopaedics (SICOT)</addtitle><addtitle>Int Orthop</addtitle><description>Purpose Proximal humerus fractures account for 4–5% of all fractures in adults and affect females more than males. With the advent of special locking plates, the treatment trend has shifted more towards a surgical approach. These methods have produced good results but very high complications rates have been reported in the literature. This study was undertaken to analyse the radiological parameters which reflect towards a favourable long term functional outcome in order to advance the surgical fixation skills for managing fractures of the proximal part of the humerus. Materials and methods 83 study participants with proximal humerus fracture fixed using proximal humerus locking plates were retrospectively analysed. The radiological parameters studied were neck shaft angle, head shaft angle, head diameter, head height, greater tuberosity to articular surface distance and reduction of the medial hinge with or without placement of calcar screw. The functional parameters assessed were the Constant Murley Score and range of movements of the shoulder joint. The patients were not followed further for the purpose of the study. Results The mean Constant Murley Score for the participants was 80.75 ± 8.09 (range 60–90). The participants with good to excellent CM Score had a significantly higher neck shaft angle (107.47 ± 9.74 v/s 124.16 ± 10.68) and (-0.28 ± 0.85 v/s 2.37 ± 2.28), head shaft angle (23.09 ± 4.82 v/s 31.76 ± 7.76), head diameter (40.08 ± 8.63 v/s 45.15 ± 4.73), head height (18.77 ± 1.96 v/s 20.69 ± 2.76) and greater tuberosity to articular surface distance (-0.28±0.85 v/s 2.37±2.28) as compared to the patients with satisfactory and worse CM Score. The patients with a higher neck shaft angle and a maintained subacromial space had a better range of shoulder abduction. A higher rate of valgus collapse was seen with an inadequate medial hinge reduction. Conclusion The radiological parameters which can predict towards a good functional outcome are a higher neck shaft angle and head shaft angle, a larger head diameter and head height, a superior position of the greater tuberosity in relation to the articular surface and a good medial hinge reduction.</description><subject>Medicine</subject><subject>Medicine &amp; Public Health</subject><subject>Original Paper</subject><subject>Orthopedics</subject><issn>0341-2695</issn><issn>1432-5195</issn><issn>1432-5195</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kMtOxCAUhonROOPoC7gwLN1UubSlLM3EWzKJG10TSmEGbUuFEnWeXmaqLl1wWJzv_HA-AM4xusIIseuAECnzDJF0Sprq9gDMcU5JVmBeHII5ojnOSMmLGTgJ4RUhzMoKH4MZ5TRnvGJz4JfOe93K0boeOgO9bKxr3doq2cJBetnpUfsAP-y4gSb2agemloujcp0OcHBhhMZ-Tgl7bPDu03YJ2sRO-xhg69Sb7ddwSO_ocAqOjGyDPvu5F-Dl7vZ5-ZCtnu4flzerTBFSjZnBpjZFUxvGCsNzqhRCuTEVkZKQxihqUN3UDeEMVZzUeUNYoRlGWGnMZFHTBbicctN_3qMOo-hsULptZa9dDIJijAkqOSUJJROqvAvBayMGnzbwXwIjsXMtJtciuRZ712Kbhi5-8mPd6eZv5FduAugEhNTq19qLVxd9shf-i_0Gr7eOjg</recordid><startdate>20241201</startdate><enddate>20241201</enddate><creator>Mathur, Bhavya</creator><creator>Suriyakumar, Sundar</creator><creator>Manickam, Karthikeyan</creator><creator>Sameer, Mohamed</creator><creator>Harshvardhan, J K Giriraj</creator><general>Springer Berlin Heidelberg</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20241201</creationdate><title>Correlation of radiological parameters with functional outcomes post fixation with proximal humerus locking plates</title><author>Mathur, Bhavya ; Suriyakumar, Sundar ; Manickam, Karthikeyan ; Sameer, Mohamed ; Harshvardhan, J K Giriraj</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c228t-f1fbf5dbf775f943cc004ff82aa22dfc3f0bdbd2970892b4d275e7101ce17a5b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Medicine</topic><topic>Medicine &amp; Public Health</topic><topic>Original Paper</topic><topic>Orthopedics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mathur, Bhavya</creatorcontrib><creatorcontrib>Suriyakumar, Sundar</creatorcontrib><creatorcontrib>Manickam, Karthikeyan</creatorcontrib><creatorcontrib>Sameer, Mohamed</creatorcontrib><creatorcontrib>Harshvardhan, J K Giriraj</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>International orthopaedics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mathur, Bhavya</au><au>Suriyakumar, Sundar</au><au>Manickam, Karthikeyan</au><au>Sameer, Mohamed</au><au>Harshvardhan, J K Giriraj</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Correlation of radiological parameters with functional outcomes post fixation with proximal humerus locking plates</atitle><jtitle>International orthopaedics</jtitle><stitle>International Orthopaedics (SICOT)</stitle><addtitle>Int Orthop</addtitle><date>2024-12-01</date><risdate>2024</risdate><volume>48</volume><issue>12</issue><spage>3207</spage><epage>3216</epage><pages>3207-3216</pages><issn>0341-2695</issn><issn>1432-5195</issn><eissn>1432-5195</eissn><abstract>Purpose Proximal humerus fractures account for 4–5% of all fractures in adults and affect females more than males. With the advent of special locking plates, the treatment trend has shifted more towards a surgical approach. These methods have produced good results but very high complications rates have been reported in the literature. This study was undertaken to analyse the radiological parameters which reflect towards a favourable long term functional outcome in order to advance the surgical fixation skills for managing fractures of the proximal part of the humerus. Materials and methods 83 study participants with proximal humerus fracture fixed using proximal humerus locking plates were retrospectively analysed. The radiological parameters studied were neck shaft angle, head shaft angle, head diameter, head height, greater tuberosity to articular surface distance and reduction of the medial hinge with or without placement of calcar screw. The functional parameters assessed were the Constant Murley Score and range of movements of the shoulder joint. The patients were not followed further for the purpose of the study. Results The mean Constant Murley Score for the participants was 80.75 ± 8.09 (range 60–90). The participants with good to excellent CM Score had a significantly higher neck shaft angle (107.47 ± 9.74 v/s 124.16 ± 10.68) and (-0.28 ± 0.85 v/s 2.37 ± 2.28), head shaft angle (23.09 ± 4.82 v/s 31.76 ± 7.76), head diameter (40.08 ± 8.63 v/s 45.15 ± 4.73), head height (18.77 ± 1.96 v/s 20.69 ± 2.76) and greater tuberosity to articular surface distance (-0.28±0.85 v/s 2.37±2.28) as compared to the patients with satisfactory and worse CM Score. The patients with a higher neck shaft angle and a maintained subacromial space had a better range of shoulder abduction. A higher rate of valgus collapse was seen with an inadequate medial hinge reduction. Conclusion The radiological parameters which can predict towards a good functional outcome are a higher neck shaft angle and head shaft angle, a larger head diameter and head height, a superior position of the greater tuberosity in relation to the articular surface and a good medial hinge reduction.</abstract><cop>Berlin/Heidelberg</cop><pub>Springer Berlin Heidelberg</pub><pmid>39347987</pmid><doi>10.1007/s00264-024-06324-z</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0341-2695
ispartof International orthopaedics, 2024-12, Vol.48 (12), p.3207-3216
issn 0341-2695
1432-5195
1432-5195
language eng
recordid cdi_proquest_miscellaneous_3111206932
source SpringerNature Journals
subjects Medicine
Medicine & Public Health
Original Paper
Orthopedics
title Correlation of radiological parameters with functional outcomes post fixation with proximal humerus locking plates
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T22%3A55%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Correlation%20of%20radiological%20parameters%20with%20functional%20outcomes%20post%20fixation%20with%20proximal%20humerus%20locking%20plates&rft.jtitle=International%20orthopaedics&rft.au=Mathur,%20Bhavya&rft.date=2024-12-01&rft.volume=48&rft.issue=12&rft.spage=3207&rft.epage=3216&rft.pages=3207-3216&rft.issn=0341-2695&rft.eissn=1432-5195&rft_id=info:doi/10.1007/s00264-024-06324-z&rft_dat=%3Cproquest_cross%3E3111206932%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3111206932&rft_id=info:pmid/39347987&rfr_iscdi=true