Assessment of Macular Hole Closure Speed Using Trans-tamponade OCT and 3-Dimensional Macular Hole Segmentation in the DISCOVER Study

Introduction: To explore opportunities for individualized postoperative positioning duration in macular hole (MH) surgery. Methods: This post hoc analysis comprised eyes that had full-thickness MH (FTMH) repair in the prospective DISCOVER intraoperative optical coherence tomography (OCT) study. Preo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of vitreoretinal diseases (Print) 2024-09, Vol.8 (5), p.558-564
Hauptverfasser: Cakir, Yavuz, Sassine, Antoine, Matar, Karen, Amine, Reem, Reese, Jamie, Srivastava, Sunil K., Ehlers, Justis P.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 564
container_issue 5
container_start_page 558
container_title Journal of vitreoretinal diseases (Print)
container_volume 8
creator Cakir, Yavuz
Sassine, Antoine
Matar, Karen
Amine, Reem
Reese, Jamie
Srivastava, Sunil K.
Ehlers, Justis P.
description Introduction: To explore opportunities for individualized postoperative positioning duration in macular hole (MH) surgery. Methods: This post hoc analysis comprised eyes that had full-thickness MH (FTMH) repair in the prospective DISCOVER intraoperative optical coherence tomography (OCT) study. Preoperative spectral-domain OCT (SD-OCT) and postoperative day 1 (POD1) trans-tamponade OCT were analyzed. Preoperative SD-OCT macular cubes were imported and analyzed using a machine learning–enhanced segmentation platform. Nine preoperative segmentation parameters were analyzed (maximum foveal height, apex area, base area, central foveal area, maximum apex diameter, maximum base diameter, maximum depth, minimum foveal width, volume). In addition, 2 new metrics—the macular hole index and tractional hole index—were calculated. POD1 trans-tamponade OCTs were obtained and evaluated for hole closure. Results: Of the 66 eyes with an FTMH, 16 (24%) had a chronic MH and 5 (8%) were reoperations from FTMH nonclosure after previous surgery. Nine eyes (14%) had an open MH on POD1 trans-tamponade OCT (6 chronic MHs [66%]; 2 reoperations [22%]); the remaining 57 MHs (86%) were closed. Multiple segmentation parameters were significantly associated with POD1 closure. Conclusions: Volumetric MH measurements and trans-tamponade POD1 OCT closure status are important in predicting MH closure speed and the need for postoperative positioning. Individualized positioning duration in MH could lower perioperative morbidity and vastly enhance quality of life.
doi_str_mv 10.1177/24741264241263172
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3109431290</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_24741264241263172</sage_id><sourcerecordid>3109431290</sourcerecordid><originalsourceid>FETCH-LOGICAL-c222t-96cdd733d795f4f5a6d7bc84482da40850f996a15fd39d4d741d05af28744dbf3</originalsourceid><addsrcrecordid>eNp9kE1LAzEQhoMoKrU_wIvk6GVrvnazOcr6CZWC23pd0k1SV_ajZnYPvfvDTWktiOAlE2beeWAehC4pmVAq5Q0TUlCWCLZ9OZXsCJ1vexFlkh0f_ok4Q2OAD0IISyVnCTtFZ1xxmqo0PkdftwAWoLFtjzuHX3Q51Nrjp662OKs7GLzF-dpagxdQtSs897qFqNfNumu1sXiWzbFuDebRXRUgUIV2_RuT29UWr_sww1WL-3eL757zbPZ2_4rzfjCbC3TidA12vK8jtHi4n2dP0XT2-JzdTqOSMdZHKimNkZwbqWInXKwTI5dlKkTKjBYkjYlTKtE0doYrI0zwY0isXbhbCLN0fISud9y17z4HC33RVFDautat7QYoOCVKcMoUCVG6i5a-A_DWFWtfNdpvCkqKrf_ij_-wc7XHD8vGmsPGj-0QmOwCoFe2-OgGH2TBP8RvsXWMWA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3109431290</pqid></control><display><type>article</type><title>Assessment of Macular Hole Closure Speed Using Trans-tamponade OCT and 3-Dimensional Macular Hole Segmentation in the DISCOVER Study</title><source>Access via SAGE</source><creator>Cakir, Yavuz ; Sassine, Antoine ; Matar, Karen ; Amine, Reem ; Reese, Jamie ; Srivastava, Sunil K. ; Ehlers, Justis P.</creator><creatorcontrib>Cakir, Yavuz ; Sassine, Antoine ; Matar, Karen ; Amine, Reem ; Reese, Jamie ; Srivastava, Sunil K. ; Ehlers, Justis P.</creatorcontrib><description>Introduction: To explore opportunities for individualized postoperative positioning duration in macular hole (MH) surgery. Methods: This post hoc analysis comprised eyes that had full-thickness MH (FTMH) repair in the prospective DISCOVER intraoperative optical coherence tomography (OCT) study. Preoperative spectral-domain OCT (SD-OCT) and postoperative day 1 (POD1) trans-tamponade OCT were analyzed. Preoperative SD-OCT macular cubes were imported and analyzed using a machine learning–enhanced segmentation platform. Nine preoperative segmentation parameters were analyzed (maximum foveal height, apex area, base area, central foveal area, maximum apex diameter, maximum base diameter, maximum depth, minimum foveal width, volume). In addition, 2 new metrics—the macular hole index and tractional hole index—were calculated. POD1 trans-tamponade OCTs were obtained and evaluated for hole closure. Results: Of the 66 eyes with an FTMH, 16 (24%) had a chronic MH and 5 (8%) were reoperations from FTMH nonclosure after previous surgery. Nine eyes (14%) had an open MH on POD1 trans-tamponade OCT (6 chronic MHs [66%]; 2 reoperations [22%]); the remaining 57 MHs (86%) were closed. Multiple segmentation parameters were significantly associated with POD1 closure. Conclusions: Volumetric MH measurements and trans-tamponade POD1 OCT closure status are important in predicting MH closure speed and the need for postoperative positioning. Individualized positioning duration in MH could lower perioperative morbidity and vastly enhance quality of life.</description><identifier>ISSN: 2474-1264</identifier><identifier>ISSN: 2474-1272</identifier><identifier>EISSN: 2474-1272</identifier><identifier>DOI: 10.1177/24741264241263172</identifier><identifier>PMID: 39318985</identifier><language>eng</language><publisher>Los Angeles, CA: SAGE Publications</publisher><ispartof>Journal of vitreoretinal diseases (Print), 2024-09, Vol.8 (5), p.558-564</ispartof><rights>The Author(s) 2024</rights><rights>The Author(s) 2024.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c222t-96cdd733d795f4f5a6d7bc84482da40850f996a15fd39d4d741d05af28744dbf3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/24741264241263172$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/24741264241263172$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,780,784,21819,27924,27925,43621,43622</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39318985$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Cakir, Yavuz</creatorcontrib><creatorcontrib>Sassine, Antoine</creatorcontrib><creatorcontrib>Matar, Karen</creatorcontrib><creatorcontrib>Amine, Reem</creatorcontrib><creatorcontrib>Reese, Jamie</creatorcontrib><creatorcontrib>Srivastava, Sunil K.</creatorcontrib><creatorcontrib>Ehlers, Justis P.</creatorcontrib><title>Assessment of Macular Hole Closure Speed Using Trans-tamponade OCT and 3-Dimensional Macular Hole Segmentation in the DISCOVER Study</title><title>Journal of vitreoretinal diseases (Print)</title><addtitle>J Vitreoretin Dis</addtitle><description>Introduction: To explore opportunities for individualized postoperative positioning duration in macular hole (MH) surgery. Methods: This post hoc analysis comprised eyes that had full-thickness MH (FTMH) repair in the prospective DISCOVER intraoperative optical coherence tomography (OCT) study. Preoperative spectral-domain OCT (SD-OCT) and postoperative day 1 (POD1) trans-tamponade OCT were analyzed. Preoperative SD-OCT macular cubes were imported and analyzed using a machine learning–enhanced segmentation platform. Nine preoperative segmentation parameters were analyzed (maximum foveal height, apex area, base area, central foveal area, maximum apex diameter, maximum base diameter, maximum depth, minimum foveal width, volume). In addition, 2 new metrics—the macular hole index and tractional hole index—were calculated. POD1 trans-tamponade OCTs were obtained and evaluated for hole closure. Results: Of the 66 eyes with an FTMH, 16 (24%) had a chronic MH and 5 (8%) were reoperations from FTMH nonclosure after previous surgery. Nine eyes (14%) had an open MH on POD1 trans-tamponade OCT (6 chronic MHs [66%]; 2 reoperations [22%]); the remaining 57 MHs (86%) were closed. Multiple segmentation parameters were significantly associated with POD1 closure. Conclusions: Volumetric MH measurements and trans-tamponade POD1 OCT closure status are important in predicting MH closure speed and the need for postoperative positioning. Individualized positioning duration in MH could lower perioperative morbidity and vastly enhance quality of life.</description><issn>2474-1264</issn><issn>2474-1272</issn><issn>2474-1272</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LAzEQhoMoKrU_wIvk6GVrvnazOcr6CZWC23pd0k1SV_ajZnYPvfvDTWktiOAlE2beeWAehC4pmVAq5Q0TUlCWCLZ9OZXsCJ1vexFlkh0f_ok4Q2OAD0IISyVnCTtFZ1xxmqo0PkdftwAWoLFtjzuHX3Q51Nrjp662OKs7GLzF-dpagxdQtSs897qFqNfNumu1sXiWzbFuDebRXRUgUIV2_RuT29UWr_sww1WL-3eL757zbPZ2_4rzfjCbC3TidA12vK8jtHi4n2dP0XT2-JzdTqOSMdZHKimNkZwbqWInXKwTI5dlKkTKjBYkjYlTKtE0doYrI0zwY0isXbhbCLN0fISud9y17z4HC33RVFDautat7QYoOCVKcMoUCVG6i5a-A_DWFWtfNdpvCkqKrf_ij_-wc7XHD8vGmsPGj-0QmOwCoFe2-OgGH2TBP8RvsXWMWA</recordid><startdate>202409</startdate><enddate>202409</enddate><creator>Cakir, Yavuz</creator><creator>Sassine, Antoine</creator><creator>Matar, Karen</creator><creator>Amine, Reem</creator><creator>Reese, Jamie</creator><creator>Srivastava, Sunil K.</creator><creator>Ehlers, Justis P.</creator><general>SAGE Publications</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202409</creationdate><title>Assessment of Macular Hole Closure Speed Using Trans-tamponade OCT and 3-Dimensional Macular Hole Segmentation in the DISCOVER Study</title><author>Cakir, Yavuz ; Sassine, Antoine ; Matar, Karen ; Amine, Reem ; Reese, Jamie ; Srivastava, Sunil K. ; Ehlers, Justis P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c222t-96cdd733d795f4f5a6d7bc84482da40850f996a15fd39d4d741d05af28744dbf3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cakir, Yavuz</creatorcontrib><creatorcontrib>Sassine, Antoine</creatorcontrib><creatorcontrib>Matar, Karen</creatorcontrib><creatorcontrib>Amine, Reem</creatorcontrib><creatorcontrib>Reese, Jamie</creatorcontrib><creatorcontrib>Srivastava, Sunil K.</creatorcontrib><creatorcontrib>Ehlers, Justis P.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of vitreoretinal diseases (Print)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cakir, Yavuz</au><au>Sassine, Antoine</au><au>Matar, Karen</au><au>Amine, Reem</au><au>Reese, Jamie</au><au>Srivastava, Sunil K.</au><au>Ehlers, Justis P.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Assessment of Macular Hole Closure Speed Using Trans-tamponade OCT and 3-Dimensional Macular Hole Segmentation in the DISCOVER Study</atitle><jtitle>Journal of vitreoretinal diseases (Print)</jtitle><addtitle>J Vitreoretin Dis</addtitle><date>2024-09</date><risdate>2024</risdate><volume>8</volume><issue>5</issue><spage>558</spage><epage>564</epage><pages>558-564</pages><issn>2474-1264</issn><issn>2474-1272</issn><eissn>2474-1272</eissn><abstract>Introduction: To explore opportunities for individualized postoperative positioning duration in macular hole (MH) surgery. Methods: This post hoc analysis comprised eyes that had full-thickness MH (FTMH) repair in the prospective DISCOVER intraoperative optical coherence tomography (OCT) study. Preoperative spectral-domain OCT (SD-OCT) and postoperative day 1 (POD1) trans-tamponade OCT were analyzed. Preoperative SD-OCT macular cubes were imported and analyzed using a machine learning–enhanced segmentation platform. Nine preoperative segmentation parameters were analyzed (maximum foveal height, apex area, base area, central foveal area, maximum apex diameter, maximum base diameter, maximum depth, minimum foveal width, volume). In addition, 2 new metrics—the macular hole index and tractional hole index—were calculated. POD1 trans-tamponade OCTs were obtained and evaluated for hole closure. Results: Of the 66 eyes with an FTMH, 16 (24%) had a chronic MH and 5 (8%) were reoperations from FTMH nonclosure after previous surgery. Nine eyes (14%) had an open MH on POD1 trans-tamponade OCT (6 chronic MHs [66%]; 2 reoperations [22%]); the remaining 57 MHs (86%) were closed. Multiple segmentation parameters were significantly associated with POD1 closure. Conclusions: Volumetric MH measurements and trans-tamponade POD1 OCT closure status are important in predicting MH closure speed and the need for postoperative positioning. Individualized positioning duration in MH could lower perioperative morbidity and vastly enhance quality of life.</abstract><cop>Los Angeles, CA</cop><pub>SAGE Publications</pub><pmid>39318985</pmid><doi>10.1177/24741264241263172</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 2474-1264
ispartof Journal of vitreoretinal diseases (Print), 2024-09, Vol.8 (5), p.558-564
issn 2474-1264
2474-1272
2474-1272
language eng
recordid cdi_proquest_miscellaneous_3109431290
source Access via SAGE
title Assessment of Macular Hole Closure Speed Using Trans-tamponade OCT and 3-Dimensional Macular Hole Segmentation in the DISCOVER Study
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T02%3A15%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Assessment%20of%20Macular%20Hole%20Closure%20Speed%20Using%20Trans-tamponade%20OCT%20and%203-Dimensional%20Macular%20Hole%20Segmentation%20in%20the%20DISCOVER%20Study&rft.jtitle=Journal%20of%20vitreoretinal%20diseases%20(Print)&rft.au=Cakir,%20Yavuz&rft.date=2024-09&rft.volume=8&rft.issue=5&rft.spage=558&rft.epage=564&rft.pages=558-564&rft.issn=2474-1264&rft.eissn=2474-1272&rft_id=info:doi/10.1177/24741264241263172&rft_dat=%3Cproquest_cross%3E3109431290%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3109431290&rft_id=info:pmid/39318985&rft_sage_id=10.1177_24741264241263172&rfr_iscdi=true