Enhancing glass-ionomer cements with flake-shaped glass: A new frontier in dental restoration

This study aims to investigate whether the combined use of thin sheet glass (FSG) and polyurethane acrylate (PUA) can enhance the mechanical properties and biocompatibility of glass ionomer cements (GICs) to improve the overall performance of commercial GICs. In this study, an innovative approach wa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of biomedical materials research. Part A 2025-01, Vol.113 (1), p.e37780
Hauptverfasser: Song, Aiyang, Gong, Haihuan, Zhang, Jiahui, Wang, Huimin, Zhu, Song, Cui, Zhanchen
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 1
container_start_page e37780
container_title Journal of biomedical materials research. Part A
container_volume 113
creator Song, Aiyang
Gong, Haihuan
Zhang, Jiahui
Wang, Huimin
Zhu, Song
Cui, Zhanchen
description This study aims to investigate whether the combined use of thin sheet glass (FSG) and polyurethane acrylate (PUA) can enhance the mechanical properties and biocompatibility of glass ionomer cements (GICs) to improve the overall performance of commercial GICs. In this study, an innovative approach was employed by incorporating diluents and photoinitiators into PUA to develop a novel light-curable PUA material. The PUA was then used to modify the GIC to obtain PUA-modified GIC. Subsequently, physical and chemical methods were employed to corrode and chemically modify the glass fiber surface to acquire dried thin sheet glass (FSG). Different proportions of FSG (10%, 20%, and 30% by mass) were mixed with PUA-GIC to obtain FSG-PUA modified GIC. Mechanical and biocompatibility tests were conducted on regular GIC, PUA-GIC, resin-modified glass ionomer cement (RMGIC), and various proportions of FSG-PUA-GIC materials, including flexural strength, surface hardness, water absorption rate, solubility, shear strength, compressive strength (CS), in vitro cytotoxicity, as well as short-term oral toxicity and subcutaneous implantation trials. A novel FSG-PUA modified GIC was successfully prepared, which not only retained the excellent biocompatibility and fluoride ion release capacity of the original GIC but also significantly enhanced its mechanical strength and durability. The application of this innovative method provides a new direction for the development of dental restorative materials, particularly in addressing the shortcomings of GICs in terms of mechanical performance. The addition of FSG notably increased the flexural strength and surface hardness of GICs, especially at a 20% additive level, demonstrating superior performance compared with standard Fuji IX (F9) and slightly better than RMGIC. Water absorption rate and solubility initially decreased and then increased with an increase in FSG content, and significantly outperformed F9 and RMGIC at 10% and 20% additive levels. Shear strength and CS decreased with an increase in FSG content but remained superior to commercial groups. Material incubation with cells in vitro for 24-48 h showed no significant impact on cell viability, with cell viability exceeding 90%. Short-term oral toxicity tests demonstrated good biocompatibility of the material, and subcutaneous implant trials did not observe any significant inflammation or pathological changes within 12 weeks of observation. The use of FSG-PUA materials effectiv
doi_str_mv 10.1002/jbm.a.37780
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3100273756</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3100273756</sourcerecordid><originalsourceid>FETCH-LOGICAL-c214t-cb44e3bac7e6f31a00fd767d60faa2e5263f7e2f372a1ae67c1c3690410552833</originalsourceid><addsrcrecordid>eNo90D1PwzAQBmALgWgpTOzIIxJK8UdiN2xVVT6kSiwwoujinNuUxCl2qop_j0sLk2947j35JeSaszFnTNyvy3YMY6n1hJ2QIc8ykaS5yk73c5onUuRqQC5CWEesWCbOyUDmQoiUpUPyMXcrcKZ2S7psIISk7lzXoqcGW3R9oLu6X1HbwCcmYQUbrA7ugU6pwx21vnN9HX3taBUXoKEeQ9956GPSJTmz0AS8Or4j8v44f5s9J4vXp5fZdJEYwdM-MWWaoizBaFRWcmDMVlrpSjELIDATSlqNwkotgAMqbbiRKmcpZ_G3EylH5PaQu_Hd1zbeL9o6GGwacNhtQyH3RWmpMxXp3YEa34Xg0RYbX7fgvwvOij0rYp8FFL99Rn1zDN6WLVb_9q9A-QN3dXFv</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3100273756</pqid></control><display><type>article</type><title>Enhancing glass-ionomer cements with flake-shaped glass: A new frontier in dental restoration</title><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><creator>Song, Aiyang ; Gong, Haihuan ; Zhang, Jiahui ; Wang, Huimin ; Zhu, Song ; Cui, Zhanchen</creator><creatorcontrib>Song, Aiyang ; Gong, Haihuan ; Zhang, Jiahui ; Wang, Huimin ; Zhu, Song ; Cui, Zhanchen</creatorcontrib><description>This study aims to investigate whether the combined use of thin sheet glass (FSG) and polyurethane acrylate (PUA) can enhance the mechanical properties and biocompatibility of glass ionomer cements (GICs) to improve the overall performance of commercial GICs. In this study, an innovative approach was employed by incorporating diluents and photoinitiators into PUA to develop a novel light-curable PUA material. The PUA was then used to modify the GIC to obtain PUA-modified GIC. Subsequently, physical and chemical methods were employed to corrode and chemically modify the glass fiber surface to acquire dried thin sheet glass (FSG). Different proportions of FSG (10%, 20%, and 30% by mass) were mixed with PUA-GIC to obtain FSG-PUA modified GIC. Mechanical and biocompatibility tests were conducted on regular GIC, PUA-GIC, resin-modified glass ionomer cement (RMGIC), and various proportions of FSG-PUA-GIC materials, including flexural strength, surface hardness, water absorption rate, solubility, shear strength, compressive strength (CS), in vitro cytotoxicity, as well as short-term oral toxicity and subcutaneous implantation trials. A novel FSG-PUA modified GIC was successfully prepared, which not only retained the excellent biocompatibility and fluoride ion release capacity of the original GIC but also significantly enhanced its mechanical strength and durability. The application of this innovative method provides a new direction for the development of dental restorative materials, particularly in addressing the shortcomings of GICs in terms of mechanical performance. The addition of FSG notably increased the flexural strength and surface hardness of GICs, especially at a 20% additive level, demonstrating superior performance compared with standard Fuji IX (F9) and slightly better than RMGIC. Water absorption rate and solubility initially decreased and then increased with an increase in FSG content, and significantly outperformed F9 and RMGIC at 10% and 20% additive levels. Shear strength and CS decreased with an increase in FSG content but remained superior to commercial groups. Material incubation with cells in vitro for 24-48 h showed no significant impact on cell viability, with cell viability exceeding 90%. Short-term oral toxicity tests demonstrated good biocompatibility of the material, and subcutaneous implant trials did not observe any significant inflammation or pathological changes within 12 weeks of observation. The use of FSG-PUA materials effectively enhances the mechanical properties of GIC materials, demonstrating excellent biocompatibility and significant potential as dental restorative materials. Among them, the 20% FSG-PUA modified GICs exhibited significantly superior flexural strength, surface hardness, shear strength, water absorption, and solubility compared with F9 and slightly surpassing RMGIC, showcasing the best mechanical performance.</description><identifier>ISSN: 1549-3296</identifier><identifier>ISSN: 1552-4965</identifier><identifier>EISSN: 1552-4965</identifier><identifier>DOI: 10.1002/jbm.a.37780</identifier><identifier>PMID: 39222404</identifier><language>eng</language><publisher>United States</publisher><subject>Animals ; Biocompatible Materials - chemistry ; Compressive Strength ; Dental Restoration, Permanent - methods ; Glass - chemistry ; Glass Ionomer Cements - chemistry ; Materials Testing ; Mice ; Polyurethanes - chemistry</subject><ispartof>Journal of biomedical materials research. Part A, 2025-01, Vol.113 (1), p.e37780</ispartof><rights>2024 Wiley Periodicals LLC.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c214t-cb44e3bac7e6f31a00fd767d60faa2e5263f7e2f372a1ae67c1c3690410552833</cites><orcidid>0000-0002-2391-9381 ; 0009-0000-2436-5379</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39222404$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Song, Aiyang</creatorcontrib><creatorcontrib>Gong, Haihuan</creatorcontrib><creatorcontrib>Zhang, Jiahui</creatorcontrib><creatorcontrib>Wang, Huimin</creatorcontrib><creatorcontrib>Zhu, Song</creatorcontrib><creatorcontrib>Cui, Zhanchen</creatorcontrib><title>Enhancing glass-ionomer cements with flake-shaped glass: A new frontier in dental restoration</title><title>Journal of biomedical materials research. Part A</title><addtitle>J Biomed Mater Res A</addtitle><description>This study aims to investigate whether the combined use of thin sheet glass (FSG) and polyurethane acrylate (PUA) can enhance the mechanical properties and biocompatibility of glass ionomer cements (GICs) to improve the overall performance of commercial GICs. In this study, an innovative approach was employed by incorporating diluents and photoinitiators into PUA to develop a novel light-curable PUA material. The PUA was then used to modify the GIC to obtain PUA-modified GIC. Subsequently, physical and chemical methods were employed to corrode and chemically modify the glass fiber surface to acquire dried thin sheet glass (FSG). Different proportions of FSG (10%, 20%, and 30% by mass) were mixed with PUA-GIC to obtain FSG-PUA modified GIC. Mechanical and biocompatibility tests were conducted on regular GIC, PUA-GIC, resin-modified glass ionomer cement (RMGIC), and various proportions of FSG-PUA-GIC materials, including flexural strength, surface hardness, water absorption rate, solubility, shear strength, compressive strength (CS), in vitro cytotoxicity, as well as short-term oral toxicity and subcutaneous implantation trials. A novel FSG-PUA modified GIC was successfully prepared, which not only retained the excellent biocompatibility and fluoride ion release capacity of the original GIC but also significantly enhanced its mechanical strength and durability. The application of this innovative method provides a new direction for the development of dental restorative materials, particularly in addressing the shortcomings of GICs in terms of mechanical performance. The addition of FSG notably increased the flexural strength and surface hardness of GICs, especially at a 20% additive level, demonstrating superior performance compared with standard Fuji IX (F9) and slightly better than RMGIC. Water absorption rate and solubility initially decreased and then increased with an increase in FSG content, and significantly outperformed F9 and RMGIC at 10% and 20% additive levels. Shear strength and CS decreased with an increase in FSG content but remained superior to commercial groups. Material incubation with cells in vitro for 24-48 h showed no significant impact on cell viability, with cell viability exceeding 90%. Short-term oral toxicity tests demonstrated good biocompatibility of the material, and subcutaneous implant trials did not observe any significant inflammation or pathological changes within 12 weeks of observation. The use of FSG-PUA materials effectively enhances the mechanical properties of GIC materials, demonstrating excellent biocompatibility and significant potential as dental restorative materials. Among them, the 20% FSG-PUA modified GICs exhibited significantly superior flexural strength, surface hardness, shear strength, water absorption, and solubility compared with F9 and slightly surpassing RMGIC, showcasing the best mechanical performance.</description><subject>Animals</subject><subject>Biocompatible Materials - chemistry</subject><subject>Compressive Strength</subject><subject>Dental Restoration, Permanent - methods</subject><subject>Glass - chemistry</subject><subject>Glass Ionomer Cements - chemistry</subject><subject>Materials Testing</subject><subject>Mice</subject><subject>Polyurethanes - chemistry</subject><issn>1549-3296</issn><issn>1552-4965</issn><issn>1552-4965</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2025</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo90D1PwzAQBmALgWgpTOzIIxJK8UdiN2xVVT6kSiwwoujinNuUxCl2qop_j0sLk2947j35JeSaszFnTNyvy3YMY6n1hJ2QIc8ykaS5yk73c5onUuRqQC5CWEesWCbOyUDmQoiUpUPyMXcrcKZ2S7psIISk7lzXoqcGW3R9oLu6X1HbwCcmYQUbrA7ugU6pwx21vnN9HX3taBUXoKEeQ9956GPSJTmz0AS8Or4j8v44f5s9J4vXp5fZdJEYwdM-MWWaoizBaFRWcmDMVlrpSjELIDATSlqNwkotgAMqbbiRKmcpZ_G3EylH5PaQu_Hd1zbeL9o6GGwacNhtQyH3RWmpMxXp3YEa34Xg0RYbX7fgvwvOij0rYp8FFL99Rn1zDN6WLVb_9q9A-QN3dXFv</recordid><startdate>202501</startdate><enddate>202501</enddate><creator>Song, Aiyang</creator><creator>Gong, Haihuan</creator><creator>Zhang, Jiahui</creator><creator>Wang, Huimin</creator><creator>Zhu, Song</creator><creator>Cui, Zhanchen</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-2391-9381</orcidid><orcidid>https://orcid.org/0009-0000-2436-5379</orcidid></search><sort><creationdate>202501</creationdate><title>Enhancing glass-ionomer cements with flake-shaped glass: A new frontier in dental restoration</title><author>Song, Aiyang ; Gong, Haihuan ; Zhang, Jiahui ; Wang, Huimin ; Zhu, Song ; Cui, Zhanchen</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c214t-cb44e3bac7e6f31a00fd767d60faa2e5263f7e2f372a1ae67c1c3690410552833</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2025</creationdate><topic>Animals</topic><topic>Biocompatible Materials - chemistry</topic><topic>Compressive Strength</topic><topic>Dental Restoration, Permanent - methods</topic><topic>Glass - chemistry</topic><topic>Glass Ionomer Cements - chemistry</topic><topic>Materials Testing</topic><topic>Mice</topic><topic>Polyurethanes - chemistry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Song, Aiyang</creatorcontrib><creatorcontrib>Gong, Haihuan</creatorcontrib><creatorcontrib>Zhang, Jiahui</creatorcontrib><creatorcontrib>Wang, Huimin</creatorcontrib><creatorcontrib>Zhu, Song</creatorcontrib><creatorcontrib>Cui, Zhanchen</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of biomedical materials research. Part A</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Song, Aiyang</au><au>Gong, Haihuan</au><au>Zhang, Jiahui</au><au>Wang, Huimin</au><au>Zhu, Song</au><au>Cui, Zhanchen</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Enhancing glass-ionomer cements with flake-shaped glass: A new frontier in dental restoration</atitle><jtitle>Journal of biomedical materials research. Part A</jtitle><addtitle>J Biomed Mater Res A</addtitle><date>2025-01</date><risdate>2025</risdate><volume>113</volume><issue>1</issue><spage>e37780</spage><pages>e37780-</pages><issn>1549-3296</issn><issn>1552-4965</issn><eissn>1552-4965</eissn><abstract>This study aims to investigate whether the combined use of thin sheet glass (FSG) and polyurethane acrylate (PUA) can enhance the mechanical properties and biocompatibility of glass ionomer cements (GICs) to improve the overall performance of commercial GICs. In this study, an innovative approach was employed by incorporating diluents and photoinitiators into PUA to develop a novel light-curable PUA material. The PUA was then used to modify the GIC to obtain PUA-modified GIC. Subsequently, physical and chemical methods were employed to corrode and chemically modify the glass fiber surface to acquire dried thin sheet glass (FSG). Different proportions of FSG (10%, 20%, and 30% by mass) were mixed with PUA-GIC to obtain FSG-PUA modified GIC. Mechanical and biocompatibility tests were conducted on regular GIC, PUA-GIC, resin-modified glass ionomer cement (RMGIC), and various proportions of FSG-PUA-GIC materials, including flexural strength, surface hardness, water absorption rate, solubility, shear strength, compressive strength (CS), in vitro cytotoxicity, as well as short-term oral toxicity and subcutaneous implantation trials. A novel FSG-PUA modified GIC was successfully prepared, which not only retained the excellent biocompatibility and fluoride ion release capacity of the original GIC but also significantly enhanced its mechanical strength and durability. The application of this innovative method provides a new direction for the development of dental restorative materials, particularly in addressing the shortcomings of GICs in terms of mechanical performance. The addition of FSG notably increased the flexural strength and surface hardness of GICs, especially at a 20% additive level, demonstrating superior performance compared with standard Fuji IX (F9) and slightly better than RMGIC. Water absorption rate and solubility initially decreased and then increased with an increase in FSG content, and significantly outperformed F9 and RMGIC at 10% and 20% additive levels. Shear strength and CS decreased with an increase in FSG content but remained superior to commercial groups. Material incubation with cells in vitro for 24-48 h showed no significant impact on cell viability, with cell viability exceeding 90%. Short-term oral toxicity tests demonstrated good biocompatibility of the material, and subcutaneous implant trials did not observe any significant inflammation or pathological changes within 12 weeks of observation. The use of FSG-PUA materials effectively enhances the mechanical properties of GIC materials, demonstrating excellent biocompatibility and significant potential as dental restorative materials. Among them, the 20% FSG-PUA modified GICs exhibited significantly superior flexural strength, surface hardness, shear strength, water absorption, and solubility compared with F9 and slightly surpassing RMGIC, showcasing the best mechanical performance.</abstract><cop>United States</cop><pmid>39222404</pmid><doi>10.1002/jbm.a.37780</doi><orcidid>https://orcid.org/0000-0002-2391-9381</orcidid><orcidid>https://orcid.org/0009-0000-2436-5379</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1549-3296
ispartof Journal of biomedical materials research. Part A, 2025-01, Vol.113 (1), p.e37780
issn 1549-3296
1552-4965
1552-4965
language eng
recordid cdi_proquest_miscellaneous_3100273756
source MEDLINE; Wiley Online Library Journals Frontfile Complete
subjects Animals
Biocompatible Materials - chemistry
Compressive Strength
Dental Restoration, Permanent - methods
Glass - chemistry
Glass Ionomer Cements - chemistry
Materials Testing
Mice
Polyurethanes - chemistry
title Enhancing glass-ionomer cements with flake-shaped glass: A new frontier in dental restoration
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T07%3A56%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Enhancing%20glass-ionomer%20cements%20with%20flake-shaped%20glass:%20A%20new%20frontier%20in%20dental%20restoration&rft.jtitle=Journal%20of%20biomedical%20materials%20research.%20Part%20A&rft.au=Song,%20Aiyang&rft.date=2025-01&rft.volume=113&rft.issue=1&rft.spage=e37780&rft.pages=e37780-&rft.issn=1549-3296&rft.eissn=1552-4965&rft_id=info:doi/10.1002/jbm.a.37780&rft_dat=%3Cproquest_cross%3E3100273756%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3100273756&rft_id=info:pmid/39222404&rfr_iscdi=true