Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
A point-of-care non-invasive test for Coronary Artery Disease (CAD) (POC-CAD) has been previously developed and validated. The test requires the simultaneous acquisition of orthogonal voltage gradient (OVG) and photoplethysmogram signals, which is the primary methodology described in this paper. The...
Gespeichert in:
Veröffentlicht in: | Journal of visualized experiments 2024-08 (210) |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 210 |
container_start_page | |
container_title | Journal of visualized experiments |
container_volume | |
creator | Burton, Timothy Nemati, Navid Fathieh, Farhad Gillins, Horace R Bridges, Charles R Ramchandani, Shyam Shadforth, Ian |
description | A point-of-care non-invasive test for Coronary Artery Disease (CAD) (POC-CAD) has been previously developed and validated. The test requires the simultaneous acquisition of orthogonal voltage gradient (OVG) and photoplethysmogram signals, which is the primary methodology described in this paper. The acquisition of the OVG, a biopotential signal, necessitates the placement of electrodes on the prepared skin of the patient's thorax (arranged similarly to the Frank lead configuration, comprising six bipolar electrodes and a reference electrode) and a hemodynamic sensor on the finger (using a standard transmission modality). The signal is uploaded to a cloud-based system, where engineered features are extracted from the signal and supplied to a machine-learned algorithm to yield the CAD Score. The physician must then interpret the value of the CAD Score in the context of their patient's pre-test probability of CAD, resulting in a post-test probability of CAD. This interpretation can be performed at the level of test positivity and test negativity or at a finer level of granularity; methodologies for each are proposed here based on likelihood ratios. Using the post-test probability, the physician must determine the appropriate next step in the treatment of their patient; several scenarios are used to illustrate this process. Test adoption is only feasible if economically viable; a discussion of the integration of the test into the CAD diagnostic flow and the resultant cost savings to the healthcare system is provided. The economic model demonstrates that cost savings to the healthcare system can be achieved by preventing delayed treatment, which, if left unaddressed, results in disease progression requiring more advanced (and expensive) care. |
doi_str_mv | 10.3791/66933 |
format | Article |
fullrecord | <record><control><sourceid>proquest_223</sourceid><recordid>TN_cdi_proquest_miscellaneous_3097151546</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3097151546</sourcerecordid><originalsourceid>FETCH-LOGICAL-c171t-8394178e1e451a2cc0075f4e18fc6e64dac1eb2e1a5f66a8312ac9d5e5f5d4353</originalsourceid><addsrcrecordid>eNpNkNFKwzAUhoMobs69guRG8MJq0jRtejnq1MFQYRO8K1l6IpE22ZJ2uLe3uilencPhOz8_H0JjSm5YltPbNM0ZO0JDmickIiJ7O_63D9BZCB-EpDHh4hQNWE4FFzwfos-FebeyxhO16UwwrXH2Gi-U84BntgW_9tDK_VXaCk-Vs64xKmCnscRPzkYzu5XBbAG_OGPbyOmokP33EkKLtfO4cN5Z6Xd44vu8Hb4zAWSAc3SiZR1gfJgj9Ho_XRaP0fz5YVZM5pGiGW0jwfKEZgIoJJzKWClCMq4ToEKrFNKkkorCKgYquU5TKRiNpcorDlzzKmGcjdDVPnft3abrS5WNCQrqWlpwXSgZyTPKKU_SHr3co8q7EDzocu1N01cvKSm_JZc_knvu4hDZrRqo_qhfq-wLQFF23A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3097151546</pqid></control><display><type>article</type><title>Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease</title><source>Journal of Visualized Experiments : JoVE</source><creator>Burton, Timothy ; Nemati, Navid ; Fathieh, Farhad ; Gillins, Horace R ; Bridges, Charles R ; Ramchandani, Shyam ; Shadforth, Ian</creator><creatorcontrib>Burton, Timothy ; Nemati, Navid ; Fathieh, Farhad ; Gillins, Horace R ; Bridges, Charles R ; Ramchandani, Shyam ; Shadforth, Ian</creatorcontrib><description>A point-of-care non-invasive test for Coronary Artery Disease (CAD) (POC-CAD) has been previously developed and validated. The test requires the simultaneous acquisition of orthogonal voltage gradient (OVG) and photoplethysmogram signals, which is the primary methodology described in this paper. The acquisition of the OVG, a biopotential signal, necessitates the placement of electrodes on the prepared skin of the patient's thorax (arranged similarly to the Frank lead configuration, comprising six bipolar electrodes and a reference electrode) and a hemodynamic sensor on the finger (using a standard transmission modality). The signal is uploaded to a cloud-based system, where engineered features are extracted from the signal and supplied to a machine-learned algorithm to yield the CAD Score. The physician must then interpret the value of the CAD Score in the context of their patient's pre-test probability of CAD, resulting in a post-test probability of CAD. This interpretation can be performed at the level of test positivity and test negativity or at a finer level of granularity; methodologies for each are proposed here based on likelihood ratios. Using the post-test probability, the physician must determine the appropriate next step in the treatment of their patient; several scenarios are used to illustrate this process. Test adoption is only feasible if economically viable; a discussion of the integration of the test into the CAD diagnostic flow and the resultant cost savings to the healthcare system is provided. The economic model demonstrates that cost savings to the healthcare system can be achieved by preventing delayed treatment, which, if left unaddressed, results in disease progression requiring more advanced (and expensive) care.</description><identifier>ISSN: 1940-087X</identifier><identifier>EISSN: 1940-087X</identifier><identifier>DOI: 10.3791/66933</identifier><identifier>PMID: 39185859</identifier><language>eng</language><publisher>United States</publisher><subject>Algorithms ; Coronary Artery Disease - diagnosis ; Coronary Artery Disease - economics ; Humans ; Photoplethysmography - instrumentation ; Photoplethysmography - methods ; Point-of-Care Testing - economics</subject><ispartof>Journal of visualized experiments, 2024-08 (210)</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,3830,27903,27904</link.rule.ids><linktorsrc>$$Uhttp://dx.doi.org/10.3791/66933$$EView_record_in_Journal_of_Visualized_Experiments$$FView_record_in_$$GJournal_of_Visualized_Experiments</linktorsrc><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39185859$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Burton, Timothy</creatorcontrib><creatorcontrib>Nemati, Navid</creatorcontrib><creatorcontrib>Fathieh, Farhad</creatorcontrib><creatorcontrib>Gillins, Horace R</creatorcontrib><creatorcontrib>Bridges, Charles R</creatorcontrib><creatorcontrib>Ramchandani, Shyam</creatorcontrib><creatorcontrib>Shadforth, Ian</creatorcontrib><title>Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease</title><title>Journal of visualized experiments</title><addtitle>J Vis Exp</addtitle><description>A point-of-care non-invasive test for Coronary Artery Disease (CAD) (POC-CAD) has been previously developed and validated. The test requires the simultaneous acquisition of orthogonal voltage gradient (OVG) and photoplethysmogram signals, which is the primary methodology described in this paper. The acquisition of the OVG, a biopotential signal, necessitates the placement of electrodes on the prepared skin of the patient's thorax (arranged similarly to the Frank lead configuration, comprising six bipolar electrodes and a reference electrode) and a hemodynamic sensor on the finger (using a standard transmission modality). The signal is uploaded to a cloud-based system, where engineered features are extracted from the signal and supplied to a machine-learned algorithm to yield the CAD Score. The physician must then interpret the value of the CAD Score in the context of their patient's pre-test probability of CAD, resulting in a post-test probability of CAD. This interpretation can be performed at the level of test positivity and test negativity or at a finer level of granularity; methodologies for each are proposed here based on likelihood ratios. Using the post-test probability, the physician must determine the appropriate next step in the treatment of their patient; several scenarios are used to illustrate this process. Test adoption is only feasible if economically viable; a discussion of the integration of the test into the CAD diagnostic flow and the resultant cost savings to the healthcare system is provided. The economic model demonstrates that cost savings to the healthcare system can be achieved by preventing delayed treatment, which, if left unaddressed, results in disease progression requiring more advanced (and expensive) care.</description><subject>Algorithms</subject><subject>Coronary Artery Disease - diagnosis</subject><subject>Coronary Artery Disease - economics</subject><subject>Humans</subject><subject>Photoplethysmography - instrumentation</subject><subject>Photoplethysmography - methods</subject><subject>Point-of-Care Testing - economics</subject><issn>1940-087X</issn><issn>1940-087X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpNkNFKwzAUhoMobs69guRG8MJq0jRtejnq1MFQYRO8K1l6IpE22ZJ2uLe3uilencPhOz8_H0JjSm5YltPbNM0ZO0JDmickIiJ7O_63D9BZCB-EpDHh4hQNWE4FFzwfos-FebeyxhO16UwwrXH2Gi-U84BntgW_9tDK_VXaCk-Vs64xKmCnscRPzkYzu5XBbAG_OGPbyOmokP33EkKLtfO4cN5Z6Xd44vu8Hb4zAWSAc3SiZR1gfJgj9Ho_XRaP0fz5YVZM5pGiGW0jwfKEZgIoJJzKWClCMq4ToEKrFNKkkorCKgYquU5TKRiNpcorDlzzKmGcjdDVPnft3abrS5WNCQrqWlpwXSgZyTPKKU_SHr3co8q7EDzocu1N01cvKSm_JZc_knvu4hDZrRqo_qhfq-wLQFF23A</recordid><startdate>20240809</startdate><enddate>20240809</enddate><creator>Burton, Timothy</creator><creator>Nemati, Navid</creator><creator>Fathieh, Farhad</creator><creator>Gillins, Horace R</creator><creator>Bridges, Charles R</creator><creator>Ramchandani, Shyam</creator><creator>Shadforth, Ian</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20240809</creationdate><title>Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease</title><author>Burton, Timothy ; Nemati, Navid ; Fathieh, Farhad ; Gillins, Horace R ; Bridges, Charles R ; Ramchandani, Shyam ; Shadforth, Ian</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c171t-8394178e1e451a2cc0075f4e18fc6e64dac1eb2e1a5f66a8312ac9d5e5f5d4353</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Algorithms</topic><topic>Coronary Artery Disease - diagnosis</topic><topic>Coronary Artery Disease - economics</topic><topic>Humans</topic><topic>Photoplethysmography - instrumentation</topic><topic>Photoplethysmography - methods</topic><topic>Point-of-Care Testing - economics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Burton, Timothy</creatorcontrib><creatorcontrib>Nemati, Navid</creatorcontrib><creatorcontrib>Fathieh, Farhad</creatorcontrib><creatorcontrib>Gillins, Horace R</creatorcontrib><creatorcontrib>Bridges, Charles R</creatorcontrib><creatorcontrib>Ramchandani, Shyam</creatorcontrib><creatorcontrib>Shadforth, Ian</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of visualized experiments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Burton, Timothy</au><au>Nemati, Navid</au><au>Fathieh, Farhad</au><au>Gillins, Horace R</au><au>Bridges, Charles R</au><au>Ramchandani, Shyam</au><au>Shadforth, Ian</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease</atitle><jtitle>Journal of visualized experiments</jtitle><addtitle>J Vis Exp</addtitle><date>2024-08-09</date><risdate>2024</risdate><issue>210</issue><issn>1940-087X</issn><eissn>1940-087X</eissn><abstract>A point-of-care non-invasive test for Coronary Artery Disease (CAD) (POC-CAD) has been previously developed and validated. The test requires the simultaneous acquisition of orthogonal voltage gradient (OVG) and photoplethysmogram signals, which is the primary methodology described in this paper. The acquisition of the OVG, a biopotential signal, necessitates the placement of electrodes on the prepared skin of the patient's thorax (arranged similarly to the Frank lead configuration, comprising six bipolar electrodes and a reference electrode) and a hemodynamic sensor on the finger (using a standard transmission modality). The signal is uploaded to a cloud-based system, where engineered features are extracted from the signal and supplied to a machine-learned algorithm to yield the CAD Score. The physician must then interpret the value of the CAD Score in the context of their patient's pre-test probability of CAD, resulting in a post-test probability of CAD. This interpretation can be performed at the level of test positivity and test negativity or at a finer level of granularity; methodologies for each are proposed here based on likelihood ratios. Using the post-test probability, the physician must determine the appropriate next step in the treatment of their patient; several scenarios are used to illustrate this process. Test adoption is only feasible if economically viable; a discussion of the integration of the test into the CAD diagnostic flow and the resultant cost savings to the healthcare system is provided. The economic model demonstrates that cost savings to the healthcare system can be achieved by preventing delayed treatment, which, if left unaddressed, results in disease progression requiring more advanced (and expensive) care.</abstract><cop>United States</cop><pmid>39185859</pmid><doi>10.3791/66933</doi></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 1940-087X |
ispartof | Journal of visualized experiments, 2024-08 (210) |
issn | 1940-087X 1940-087X |
language | eng |
recordid | cdi_proquest_miscellaneous_3097151546 |
source | Journal of Visualized Experiments : JoVE |
subjects | Algorithms Coronary Artery Disease - diagnosis Coronary Artery Disease - economics Humans Photoplethysmography - instrumentation Photoplethysmography - methods Point-of-Care Testing - economics |
title | Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T14%3A04%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_223&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Signal%20Acquisition,%20Score%20Interpretation,%20and%20Economics%20of%20a%20Non-Invasive%20Point-of-Care%20Test%20for%20Coronary%20Artery%20Disease&rft.jtitle=Journal%20of%20visualized%20experiments&rft.au=Burton,%20Timothy&rft.date=2024-08-09&rft.issue=210&rft.issn=1940-087X&rft.eissn=1940-087X&rft_id=info:doi/10.3791/66933&rft_dat=%3Cproquest_223%3E3097151546%3C/proquest_223%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3097151546&rft_id=info:pmid/39185859&rfr_iscdi=true |