Phase detection using AD8302 evaluation board in the superheterodyne microwave interferometer for line average plasma electron density measurements

In this paper the use of AD8302 evaluation board from analog devices for phase detection and consequently line average electron density measurement in the superheterodyne microwave interferometer is described. The phase is directly measured from this board. This method is very cheap and easy to inte...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Measurement : journal of the International Measurement Confederation 2007-11, Vol.40 (9), p.849-853
Hauptverfasser: Yee, Y.F., Chakrabarty, C.K.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 853
container_issue 9
container_start_page 849
container_title Measurement : journal of the International Measurement Confederation
container_volume 40
creator Yee, Y.F.
Chakrabarty, C.K.
description In this paper the use of AD8302 evaluation board from analog devices for phase detection and consequently line average electron density measurement in the superheterodyne microwave interferometer is described. The phase is directly measured from this board. This method is very cheap and easy to integrate. For the measurement, signals that were obtained from the IF of both the mixers in the interferometer were fed as inputs to the evaluation board. The output was connected to an oscilloscope to capture the voltage trace. The voltage reading was then converted to phase angle by using the calibration data provided with the evaluation board. The plasma used to test the phase detection system was a microwave plasma discharge. The phase measurements were obtained very quickly without the use of a computer. These were then translated to line average electron density. The values were agreeable to published results.
doi_str_mv 10.1016/j.measurement.2007.02.005
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_30968119</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0263224107000218</els_id><sourcerecordid>30968119</sourcerecordid><originalsourceid>FETCH-LOGICAL-c352t-971f57f73848d5371eefc2b723a5cd5d69937cca23d54b6fd22f5ae187cf53bc3</originalsourceid><addsrcrecordid>eNqNUbtOAzEQtBBIhMA_mIbuDj_O9yij8JQiQQESneWz14mjewT7LijfwQ_jEIqUVCvNzsxqdhC6piSlhOa367QFFUYPLXRDyggpUsJSQsQJmtCy4ElG2ccpmhCW84SxjJ6jixDWhJCcV_kEfb-uVABsYAA9uL7DY3DdEs_uSk4Yhq1qRvWL173yBrsODyvAYdyAX0WN782uA9w67fsvtYVIiKCNeLvfYtt73LjIiDuvloA3jQqtwtDEcz7aGuiCG3b4KEW4RGdWNQGu_uYUvT_cv82fksXL4_N8tkg0F2xIqoJaUdiCl1lpBC8ogNWsLhhXQhth8qrihdaKcSOyOreGMSsUxK9oK3it-RTdHHw3vv8cIQyydUFD06gO-jFITqq8pLSKxOpAjClD8GDlxrtW-Z2kRO5rkGt5FEDua5CEyVhD1M4PWohJtg68DNpBp8E4H38gTe_-4fIDCBGcFQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>30968119</pqid></control><display><type>article</type><title>Phase detection using AD8302 evaluation board in the superheterodyne microwave interferometer for line average plasma electron density measurements</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Yee, Y.F. ; Chakrabarty, C.K.</creator><creatorcontrib>Yee, Y.F. ; Chakrabarty, C.K.</creatorcontrib><description>In this paper the use of AD8302 evaluation board from analog devices for phase detection and consequently line average electron density measurement in the superheterodyne microwave interferometer is described. The phase is directly measured from this board. This method is very cheap and easy to integrate. For the measurement, signals that were obtained from the IF of both the mixers in the interferometer were fed as inputs to the evaluation board. The output was connected to an oscilloscope to capture the voltage trace. The voltage reading was then converted to phase angle by using the calibration data provided with the evaluation board. The plasma used to test the phase detection system was a microwave plasma discharge. The phase measurements were obtained very quickly without the use of a computer. These were then translated to line average electron density. The values were agreeable to published results.</description><identifier>ISSN: 0263-2241</identifier><identifier>EISSN: 1873-412X</identifier><identifier>DOI: 10.1016/j.measurement.2007.02.005</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Interferometer ; Phase measurement ; Plasma diagnostic</subject><ispartof>Measurement : journal of the International Measurement Confederation, 2007-11, Vol.40 (9), p.849-853</ispartof><rights>2007 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c352t-971f57f73848d5371eefc2b723a5cd5d69937cca23d54b6fd22f5ae187cf53bc3</citedby><cites>FETCH-LOGICAL-c352t-971f57f73848d5371eefc2b723a5cd5d69937cca23d54b6fd22f5ae187cf53bc3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.measurement.2007.02.005$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids></links><search><creatorcontrib>Yee, Y.F.</creatorcontrib><creatorcontrib>Chakrabarty, C.K.</creatorcontrib><title>Phase detection using AD8302 evaluation board in the superheterodyne microwave interferometer for line average plasma electron density measurements</title><title>Measurement : journal of the International Measurement Confederation</title><description>In this paper the use of AD8302 evaluation board from analog devices for phase detection and consequently line average electron density measurement in the superheterodyne microwave interferometer is described. The phase is directly measured from this board. This method is very cheap and easy to integrate. For the measurement, signals that were obtained from the IF of both the mixers in the interferometer were fed as inputs to the evaluation board. The output was connected to an oscilloscope to capture the voltage trace. The voltage reading was then converted to phase angle by using the calibration data provided with the evaluation board. The plasma used to test the phase detection system was a microwave plasma discharge. The phase measurements were obtained very quickly without the use of a computer. These were then translated to line average electron density. The values were agreeable to published results.</description><subject>Interferometer</subject><subject>Phase measurement</subject><subject>Plasma diagnostic</subject><issn>0263-2241</issn><issn>1873-412X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNqNUbtOAzEQtBBIhMA_mIbuDj_O9yij8JQiQQESneWz14mjewT7LijfwQ_jEIqUVCvNzsxqdhC6piSlhOa367QFFUYPLXRDyggpUsJSQsQJmtCy4ElG2ccpmhCW84SxjJ6jixDWhJCcV_kEfb-uVABsYAA9uL7DY3DdEs_uSk4Yhq1qRvWL173yBrsODyvAYdyAX0WN782uA9w67fsvtYVIiKCNeLvfYtt73LjIiDuvloA3jQqtwtDEcz7aGuiCG3b4KEW4RGdWNQGu_uYUvT_cv82fksXL4_N8tkg0F2xIqoJaUdiCl1lpBC8ogNWsLhhXQhth8qrihdaKcSOyOreGMSsUxK9oK3it-RTdHHw3vv8cIQyydUFD06gO-jFITqq8pLSKxOpAjClD8GDlxrtW-Z2kRO5rkGt5FEDua5CEyVhD1M4PWohJtg68DNpBp8E4H38gTe_-4fIDCBGcFQ</recordid><startdate>20071101</startdate><enddate>20071101</enddate><creator>Yee, Y.F.</creator><creator>Chakrabarty, C.K.</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope></search><sort><creationdate>20071101</creationdate><title>Phase detection using AD8302 evaluation board in the superheterodyne microwave interferometer for line average plasma electron density measurements</title><author>Yee, Y.F. ; Chakrabarty, C.K.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c352t-971f57f73848d5371eefc2b723a5cd5d69937cca23d54b6fd22f5ae187cf53bc3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Interferometer</topic><topic>Phase measurement</topic><topic>Plasma diagnostic</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yee, Y.F.</creatorcontrib><creatorcontrib>Chakrabarty, C.K.</creatorcontrib><collection>CrossRef</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><jtitle>Measurement : journal of the International Measurement Confederation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yee, Y.F.</au><au>Chakrabarty, C.K.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Phase detection using AD8302 evaluation board in the superheterodyne microwave interferometer for line average plasma electron density measurements</atitle><jtitle>Measurement : journal of the International Measurement Confederation</jtitle><date>2007-11-01</date><risdate>2007</risdate><volume>40</volume><issue>9</issue><spage>849</spage><epage>853</epage><pages>849-853</pages><issn>0263-2241</issn><eissn>1873-412X</eissn><abstract>In this paper the use of AD8302 evaluation board from analog devices for phase detection and consequently line average electron density measurement in the superheterodyne microwave interferometer is described. The phase is directly measured from this board. This method is very cheap and easy to integrate. For the measurement, signals that were obtained from the IF of both the mixers in the interferometer were fed as inputs to the evaluation board. The output was connected to an oscilloscope to capture the voltage trace. The voltage reading was then converted to phase angle by using the calibration data provided with the evaluation board. The plasma used to test the phase detection system was a microwave plasma discharge. The phase measurements were obtained very quickly without the use of a computer. These were then translated to line average electron density. The values were agreeable to published results.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.measurement.2007.02.005</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0263-2241
ispartof Measurement : journal of the International Measurement Confederation, 2007-11, Vol.40 (9), p.849-853
issn 0263-2241
1873-412X
language eng
recordid cdi_proquest_miscellaneous_30968119
source Elsevier ScienceDirect Journals Complete
subjects Interferometer
Phase measurement
Plasma diagnostic
title Phase detection using AD8302 evaluation board in the superheterodyne microwave interferometer for line average plasma electron density measurements
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-23T21%3A09%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Phase%20detection%20using%20AD8302%20evaluation%20board%20in%20the%20superheterodyne%20microwave%20interferometer%20for%20line%20average%20plasma%20electron%20density%20measurements&rft.jtitle=Measurement%20:%20journal%20of%20the%20International%20Measurement%20Confederation&rft.au=Yee,%20Y.F.&rft.date=2007-11-01&rft.volume=40&rft.issue=9&rft.spage=849&rft.epage=853&rft.pages=849-853&rft.issn=0263-2241&rft.eissn=1873-412X&rft_id=info:doi/10.1016/j.measurement.2007.02.005&rft_dat=%3Cproquest_cross%3E30968119%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=30968119&rft_id=info:pmid/&rft_els_id=S0263224107000218&rfr_iscdi=true