Fixation of Gardens Type 4 Intracapsular Neck of Femur Fracture Using the GS Kulkarni Controlled Dynamic Hip Screw System
The goal for surgical treatment of femoral neck fractures is achieving union through an anatomic reduction and stable fixation while avoiding osteonecrosis. This report describes the case of a 50-year-old male who presented with pain and swelling in his right hip and inability to bear weight over hi...
Gespeichert in:
Veröffentlicht in: | Curēus (Palo Alto, CA) CA), 2024-07, Vol.16 (7), p.e64848 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 7 |
container_start_page | e64848 |
container_title | Curēus (Palo Alto, CA) |
container_volume | 16 |
creator | Phalak, Mukesh O Bhadauriya, Abhishek Gupta, Archit Gurnani, Sagar |
description | The goal for surgical treatment of femoral neck fractures is achieving union through an anatomic reduction and stable fixation while avoiding osteonecrosis. This report describes the case of a 50-year-old male who presented with pain and swelling in his right hip and inability to bear weight over his right lower limb following a road traffic accident. The X-ray revealed a right-sided femoral neck fracture (Garden Type IV and Pauwels Type III). The patient was surgically treated with the GS Kulkarni (GSK) controlled dynamic hip screw. On follow-up, the bone healing time was 14 weeks and the patient achieved a Harris hip score of 93.65 with significant improvement. |
doi_str_mv | 10.7759/cureus.64848 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3094471667</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3094471667</sourcerecordid><originalsourceid>FETCH-LOGICAL-c244t-aa7bf8bef26d9aa034890225140d7d90fb78171822e27de1024f41a3bd44e4933</originalsourceid><addsrcrecordid>eNpd0c9LwzAUB_AgisrczbMEvHhwmqRvTXqUaacoetg8l7R91bq2qUmD9r-3c1PEUx7k837Al5Bjzi6knEaXmbfo3UUICtQOORQ8VBPFFez-qQ_I2Lk3xhhnUjDJ9slBEPFpCAEckj4uP3VXmoaags61zbFxdNm3SIHeNZ3VmW6dr7Slj5it1ijG2lsaDz_dsJw-u7J5od0r0vmC3vtqpW1T0pkZek1VYU6v-0bXZUZvy5YuMosfdNG7DusjslfoyuF4-47Ic3yznN1OHp7md7Orh0kmALqJ1jItVIqFCPNIaxaAipgQUw4sl3nEilQqLrkSAoXMkTMBBXAdpDkAQhQEI3K2mdta8-7RdUldugyrSjdovEsCFgFIHoZyoKf_6JvxthmuW6tIwEDVoM43KrPGOYtF0tqy1rZPOEvWqSSbVJLvVAZ-sh3q0xrzX_yTQfAF00KIAg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3099240948</pqid></control><display><type>article</type><title>Fixation of Gardens Type 4 Intracapsular Neck of Femur Fracture Using the GS Kulkarni Controlled Dynamic Hip Screw System</title><source>PubMed Central Open Access</source><source>PubMed Central</source><creator>Phalak, Mukesh O ; Bhadauriya, Abhishek ; Gupta, Archit ; Gurnani, Sagar</creator><creatorcontrib>Phalak, Mukesh O ; Bhadauriya, Abhishek ; Gupta, Archit ; Gurnani, Sagar</creatorcontrib><description>The goal for surgical treatment of femoral neck fractures is achieving union through an anatomic reduction and stable fixation while avoiding osteonecrosis. This report describes the case of a 50-year-old male who presented with pain and swelling in his right hip and inability to bear weight over his right lower limb following a road traffic accident. The X-ray revealed a right-sided femoral neck fracture (Garden Type IV and Pauwels Type III). The patient was surgically treated with the GS Kulkarni (GSK) controlled dynamic hip screw. On follow-up, the bone healing time was 14 weeks and the patient achieved a Harris hip score of 93.65 with significant improvement.</description><identifier>ISSN: 2168-8184</identifier><identifier>EISSN: 2168-8184</identifier><identifier>DOI: 10.7759/cureus.64848</identifier><identifier>PMID: 39156434</identifier><language>eng</language><publisher>United States: Cureus Inc</publisher><subject>Bone surgery ; Fractures ; Gardens & gardening ; Hip joint ; Necrosis ; Older people ; Patients ; X-rays</subject><ispartof>Curēus (Palo Alto, CA), 2024-07, Vol.16 (7), p.e64848</ispartof><rights>Copyright © 2024, Phalak et al.</rights><rights>Copyright © 2024, Phalak et al. This work is published under https://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c244t-aa7bf8bef26d9aa034890225140d7d90fb78171822e27de1024f41a3bd44e4933</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39156434$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Phalak, Mukesh O</creatorcontrib><creatorcontrib>Bhadauriya, Abhishek</creatorcontrib><creatorcontrib>Gupta, Archit</creatorcontrib><creatorcontrib>Gurnani, Sagar</creatorcontrib><title>Fixation of Gardens Type 4 Intracapsular Neck of Femur Fracture Using the GS Kulkarni Controlled Dynamic Hip Screw System</title><title>Curēus (Palo Alto, CA)</title><addtitle>Cureus</addtitle><description>The goal for surgical treatment of femoral neck fractures is achieving union through an anatomic reduction and stable fixation while avoiding osteonecrosis. This report describes the case of a 50-year-old male who presented with pain and swelling in his right hip and inability to bear weight over his right lower limb following a road traffic accident. The X-ray revealed a right-sided femoral neck fracture (Garden Type IV and Pauwels Type III). The patient was surgically treated with the GS Kulkarni (GSK) controlled dynamic hip screw. On follow-up, the bone healing time was 14 weeks and the patient achieved a Harris hip score of 93.65 with significant improvement.</description><subject>Bone surgery</subject><subject>Fractures</subject><subject>Gardens & gardening</subject><subject>Hip joint</subject><subject>Necrosis</subject><subject>Older people</subject><subject>Patients</subject><subject>X-rays</subject><issn>2168-8184</issn><issn>2168-8184</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNpd0c9LwzAUB_AgisrczbMEvHhwmqRvTXqUaacoetg8l7R91bq2qUmD9r-3c1PEUx7k837Al5Bjzi6knEaXmbfo3UUICtQOORQ8VBPFFez-qQ_I2Lk3xhhnUjDJ9slBEPFpCAEckj4uP3VXmoaags61zbFxdNm3SIHeNZ3VmW6dr7Slj5it1ijG2lsaDz_dsJw-u7J5od0r0vmC3vtqpW1T0pkZek1VYU6v-0bXZUZvy5YuMosfdNG7DusjslfoyuF4-47Ic3yznN1OHp7md7Orh0kmALqJ1jItVIqFCPNIaxaAipgQUw4sl3nEilQqLrkSAoXMkTMBBXAdpDkAQhQEI3K2mdta8-7RdUldugyrSjdovEsCFgFIHoZyoKf_6JvxthmuW6tIwEDVoM43KrPGOYtF0tqy1rZPOEvWqSSbVJLvVAZ-sh3q0xrzX_yTQfAF00KIAg</recordid><startdate>20240718</startdate><enddate>20240718</enddate><creator>Phalak, Mukesh O</creator><creator>Bhadauriya, Abhishek</creator><creator>Gupta, Archit</creator><creator>Gurnani, Sagar</creator><general>Cureus Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope></search><sort><creationdate>20240718</creationdate><title>Fixation of Gardens Type 4 Intracapsular Neck of Femur Fracture Using the GS Kulkarni Controlled Dynamic Hip Screw System</title><author>Phalak, Mukesh O ; Bhadauriya, Abhishek ; Gupta, Archit ; Gurnani, Sagar</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c244t-aa7bf8bef26d9aa034890225140d7d90fb78171822e27de1024f41a3bd44e4933</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Bone surgery</topic><topic>Fractures</topic><topic>Gardens & gardening</topic><topic>Hip joint</topic><topic>Necrosis</topic><topic>Older people</topic><topic>Patients</topic><topic>X-rays</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Phalak, Mukesh O</creatorcontrib><creatorcontrib>Bhadauriya, Abhishek</creatorcontrib><creatorcontrib>Gupta, Archit</creatorcontrib><creatorcontrib>Gurnani, Sagar</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><jtitle>Curēus (Palo Alto, CA)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Phalak, Mukesh O</au><au>Bhadauriya, Abhishek</au><au>Gupta, Archit</au><au>Gurnani, Sagar</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fixation of Gardens Type 4 Intracapsular Neck of Femur Fracture Using the GS Kulkarni Controlled Dynamic Hip Screw System</atitle><jtitle>Curēus (Palo Alto, CA)</jtitle><addtitle>Cureus</addtitle><date>2024-07-18</date><risdate>2024</risdate><volume>16</volume><issue>7</issue><spage>e64848</spage><pages>e64848-</pages><issn>2168-8184</issn><eissn>2168-8184</eissn><abstract>The goal for surgical treatment of femoral neck fractures is achieving union through an anatomic reduction and stable fixation while avoiding osteonecrosis. This report describes the case of a 50-year-old male who presented with pain and swelling in his right hip and inability to bear weight over his right lower limb following a road traffic accident. The X-ray revealed a right-sided femoral neck fracture (Garden Type IV and Pauwels Type III). The patient was surgically treated with the GS Kulkarni (GSK) controlled dynamic hip screw. On follow-up, the bone healing time was 14 weeks and the patient achieved a Harris hip score of 93.65 with significant improvement.</abstract><cop>United States</cop><pub>Cureus Inc</pub><pmid>39156434</pmid><doi>10.7759/cureus.64848</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2168-8184 |
ispartof | Curēus (Palo Alto, CA), 2024-07, Vol.16 (7), p.e64848 |
issn | 2168-8184 2168-8184 |
language | eng |
recordid | cdi_proquest_miscellaneous_3094471667 |
source | PubMed Central Open Access; PubMed Central |
subjects | Bone surgery Fractures Gardens & gardening Hip joint Necrosis Older people Patients X-rays |
title | Fixation of Gardens Type 4 Intracapsular Neck of Femur Fracture Using the GS Kulkarni Controlled Dynamic Hip Screw System |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-19T10%3A21%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fixation%20of%20Gardens%20Type%204%20Intracapsular%20Neck%20of%20Femur%20Fracture%20Using%20the%20GS%20Kulkarni%20Controlled%20Dynamic%20Hip%20Screw%20System&rft.jtitle=Cur%C4%93us%20(Palo%20Alto,%20CA)&rft.au=Phalak,%20Mukesh%20O&rft.date=2024-07-18&rft.volume=16&rft.issue=7&rft.spage=e64848&rft.pages=e64848-&rft.issn=2168-8184&rft.eissn=2168-8184&rft_id=info:doi/10.7759/cureus.64848&rft_dat=%3Cproquest_cross%3E3094471667%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3099240948&rft_id=info:pmid/39156434&rfr_iscdi=true |