Accounting for differences between serum and plasma: An indirect approach to derive reference intervals for total protein, albumin, and globulin

•Plasma vs serum: Difference in protein levels not reflected in reference intervals.•Indirect reference intervals derived using large datasets is an effective approach.•Statistical tools can help identify healthy patients for interval estimation.•Analytes should be compared across matrices for refer...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinica chimica acta 2024-08, Vol.562, p.119851, Article 119851
Hauptverfasser: Militello, Leah, El-Khoury, Joe M., Durant, Thomas J.S.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page 119851
container_title Clinica chimica acta
container_volume 562
creator Militello, Leah
El-Khoury, Joe M.
Durant, Thomas J.S.
description •Plasma vs serum: Difference in protein levels not reflected in reference intervals.•Indirect reference intervals derived using large datasets is an effective approach.•Statistical tools can help identify healthy patients for interval estimation.•Analytes should be compared across matrices for reference interval optimization. Observable quantitative variations exist between plasma and serum in routine protein measurements, often not reflected in standard reference intervals. In this study, we describe an indirect approach for estimating a combined reference interval (RI) (i.e., serum and plasma), for commonly ordered protein measurands: total protein, albumin, and globulin. We applied an indirect reference interval estimation for protein measurements in serum and plasma using data from July 2018 to February 2024. The data were divided into three Epochs based on a period of plasma separator tube shortage during the COVID-19 pandemic. Bootstrap resampling was used to calculate RIs and corresponding 95% confidence intervals for each month. Our results demonstrate notable changes in RI limits for total protein, albumin, and globulin between Epochs, reflecting the influence of changing sample matrix. A combined RI was identified for all components and verified using plasma and serum samples from 20 healthy individuals and retrospective analysis of flagging rates on our outpatient population using new and historical RIs. The study demonstrates notable differences in the RIs for total protein, albumin, and globulin when container type changes. In addition, the results demonstrate the effectiveness of big data analytics in deriving RIs and highlights the necessity of continuous RI assessment and adjustment based on the patient population and acceptable specimen types.
doi_str_mv 10.1016/j.cca.2024.119851
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3077176012</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S000989812402103X</els_id><sourcerecordid>3077176012</sourcerecordid><originalsourceid>FETCH-LOGICAL-c235t-41633bfdc5c93561239f6ecd0d4fc60b26347b752e9719e3a14c46192cfb5fb83</originalsourceid><addsrcrecordid>eNp9kcuO0zAUhi0EYjqFB2CDvGRBii-JE8OqGsGANBIbWFu-HA-uEqfYTke8BY-MOyksWdmWvvPJ5_8RekXJjhIq3h121uodI6zdUSqHjj5BGzr0vOGtZE_RhhAim0EO9Apd53yoz5YI-hxd8UH2Pe3ZBv3eWzsvsYR4j_2csAveQ4JoIWMD5QEg4gxpmbCODh9HnSf9Hu8jDtGFBLZgfTymWdsfuMzYQQonwAkujkoVSCc95kd5mYseccULhPgW69Es0-Olqu_H2SxjiC_QM195eHk5t-j7p4_fbj43d19vv9zs7xrLeFealgrOjXe2s5J3gjIuvQDriGu9FcQwwdve9B0D2VMJXNPWtoJKZr3pvBn4Fr1ZvfU7PxfIRU0hWxhHHWFesuLknJAg1bxFdEVtmnOuy6ljCpNOvxQl6lyEOqhahDoXodYi6szri34xE7h_E3-Tr8CHFYC65ClAUtmGc2ZrrMrN4T_6PxYEmrk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3077176012</pqid></control><display><type>article</type><title>Accounting for differences between serum and plasma: An indirect approach to derive reference intervals for total protein, albumin, and globulin</title><source>Elsevier ScienceDirect Journals</source><creator>Militello, Leah ; El-Khoury, Joe M. ; Durant, Thomas J.S.</creator><creatorcontrib>Militello, Leah ; El-Khoury, Joe M. ; Durant, Thomas J.S.</creatorcontrib><description>•Plasma vs serum: Difference in protein levels not reflected in reference intervals.•Indirect reference intervals derived using large datasets is an effective approach.•Statistical tools can help identify healthy patients for interval estimation.•Analytes should be compared across matrices for reference interval optimization. Observable quantitative variations exist between plasma and serum in routine protein measurements, often not reflected in standard reference intervals. In this study, we describe an indirect approach for estimating a combined reference interval (RI) (i.e., serum and plasma), for commonly ordered protein measurands: total protein, albumin, and globulin. We applied an indirect reference interval estimation for protein measurements in serum and plasma using data from July 2018 to February 2024. The data were divided into three Epochs based on a period of plasma separator tube shortage during the COVID-19 pandemic. Bootstrap resampling was used to calculate RIs and corresponding 95% confidence intervals for each month. Our results demonstrate notable changes in RI limits for total protein, albumin, and globulin between Epochs, reflecting the influence of changing sample matrix. A combined RI was identified for all components and verified using plasma and serum samples from 20 healthy individuals and retrospective analysis of flagging rates on our outpatient population using new and historical RIs. The study demonstrates notable differences in the RIs for total protein, albumin, and globulin when container type changes. In addition, the results demonstrate the effectiveness of big data analytics in deriving RIs and highlights the necessity of continuous RI assessment and adjustment based on the patient population and acceptable specimen types.</description><identifier>ISSN: 0009-8981</identifier><identifier>ISSN: 1873-3492</identifier><identifier>EISSN: 1873-3492</identifier><identifier>DOI: 10.1016/j.cca.2024.119851</identifier><identifier>PMID: 38977172</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><ispartof>Clinica chimica acta, 2024-08, Vol.562, p.119851, Article 119851</ispartof><rights>2024</rights><rights>Copyright © 2024. Published by Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c235t-41633bfdc5c93561239f6ecd0d4fc60b26347b752e9719e3a14c46192cfb5fb83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.cca.2024.119851$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,777,781,3537,27905,27906,45976</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38977172$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Militello, Leah</creatorcontrib><creatorcontrib>El-Khoury, Joe M.</creatorcontrib><creatorcontrib>Durant, Thomas J.S.</creatorcontrib><title>Accounting for differences between serum and plasma: An indirect approach to derive reference intervals for total protein, albumin, and globulin</title><title>Clinica chimica acta</title><addtitle>Clin Chim Acta</addtitle><description>•Plasma vs serum: Difference in protein levels not reflected in reference intervals.•Indirect reference intervals derived using large datasets is an effective approach.•Statistical tools can help identify healthy patients for interval estimation.•Analytes should be compared across matrices for reference interval optimization. Observable quantitative variations exist between plasma and serum in routine protein measurements, often not reflected in standard reference intervals. In this study, we describe an indirect approach for estimating a combined reference interval (RI) (i.e., serum and plasma), for commonly ordered protein measurands: total protein, albumin, and globulin. We applied an indirect reference interval estimation for protein measurements in serum and plasma using data from July 2018 to February 2024. The data were divided into three Epochs based on a period of plasma separator tube shortage during the COVID-19 pandemic. Bootstrap resampling was used to calculate RIs and corresponding 95% confidence intervals for each month. Our results demonstrate notable changes in RI limits for total protein, albumin, and globulin between Epochs, reflecting the influence of changing sample matrix. A combined RI was identified for all components and verified using plasma and serum samples from 20 healthy individuals and retrospective analysis of flagging rates on our outpatient population using new and historical RIs. The study demonstrates notable differences in the RIs for total protein, albumin, and globulin when container type changes. In addition, the results demonstrate the effectiveness of big data analytics in deriving RIs and highlights the necessity of continuous RI assessment and adjustment based on the patient population and acceptable specimen types.</description><issn>0009-8981</issn><issn>1873-3492</issn><issn>1873-3492</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kcuO0zAUhi0EYjqFB2CDvGRBii-JE8OqGsGANBIbWFu-HA-uEqfYTke8BY-MOyksWdmWvvPJ5_8RekXJjhIq3h121uodI6zdUSqHjj5BGzr0vOGtZE_RhhAim0EO9Apd53yoz5YI-hxd8UH2Pe3ZBv3eWzsvsYR4j_2csAveQ4JoIWMD5QEg4gxpmbCODh9HnSf9Hu8jDtGFBLZgfTymWdsfuMzYQQonwAkujkoVSCc95kd5mYseccULhPgW69Es0-Olqu_H2SxjiC_QM195eHk5t-j7p4_fbj43d19vv9zs7xrLeFealgrOjXe2s5J3gjIuvQDriGu9FcQwwdve9B0D2VMJXNPWtoJKZr3pvBn4Fr1ZvfU7PxfIRU0hWxhHHWFesuLknJAg1bxFdEVtmnOuy6ljCpNOvxQl6lyEOqhahDoXodYi6szri34xE7h_E3-Tr8CHFYC65ClAUtmGc2ZrrMrN4T_6PxYEmrk</recordid><startdate>20240815</startdate><enddate>20240815</enddate><creator>Militello, Leah</creator><creator>El-Khoury, Joe M.</creator><creator>Durant, Thomas J.S.</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20240815</creationdate><title>Accounting for differences between serum and plasma: An indirect approach to derive reference intervals for total protein, albumin, and globulin</title><author>Militello, Leah ; El-Khoury, Joe M. ; Durant, Thomas J.S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c235t-41633bfdc5c93561239f6ecd0d4fc60b26347b752e9719e3a14c46192cfb5fb83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Militello, Leah</creatorcontrib><creatorcontrib>El-Khoury, Joe M.</creatorcontrib><creatorcontrib>Durant, Thomas J.S.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Clinica chimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Militello, Leah</au><au>El-Khoury, Joe M.</au><au>Durant, Thomas J.S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Accounting for differences between serum and plasma: An indirect approach to derive reference intervals for total protein, albumin, and globulin</atitle><jtitle>Clinica chimica acta</jtitle><addtitle>Clin Chim Acta</addtitle><date>2024-08-15</date><risdate>2024</risdate><volume>562</volume><spage>119851</spage><pages>119851-</pages><artnum>119851</artnum><issn>0009-8981</issn><issn>1873-3492</issn><eissn>1873-3492</eissn><abstract>•Plasma vs serum: Difference in protein levels not reflected in reference intervals.•Indirect reference intervals derived using large datasets is an effective approach.•Statistical tools can help identify healthy patients for interval estimation.•Analytes should be compared across matrices for reference interval optimization. Observable quantitative variations exist between plasma and serum in routine protein measurements, often not reflected in standard reference intervals. In this study, we describe an indirect approach for estimating a combined reference interval (RI) (i.e., serum and plasma), for commonly ordered protein measurands: total protein, albumin, and globulin. We applied an indirect reference interval estimation for protein measurements in serum and plasma using data from July 2018 to February 2024. The data were divided into three Epochs based on a period of plasma separator tube shortage during the COVID-19 pandemic. Bootstrap resampling was used to calculate RIs and corresponding 95% confidence intervals for each month. Our results demonstrate notable changes in RI limits for total protein, albumin, and globulin between Epochs, reflecting the influence of changing sample matrix. A combined RI was identified for all components and verified using plasma and serum samples from 20 healthy individuals and retrospective analysis of flagging rates on our outpatient population using new and historical RIs. The study demonstrates notable differences in the RIs for total protein, albumin, and globulin when container type changes. In addition, the results demonstrate the effectiveness of big data analytics in deriving RIs and highlights the necessity of continuous RI assessment and adjustment based on the patient population and acceptable specimen types.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>38977172</pmid><doi>10.1016/j.cca.2024.119851</doi></addata></record>
fulltext fulltext
identifier ISSN: 0009-8981
ispartof Clinica chimica acta, 2024-08, Vol.562, p.119851, Article 119851
issn 0009-8981
1873-3492
1873-3492
language eng
recordid cdi_proquest_miscellaneous_3077176012
source Elsevier ScienceDirect Journals
title Accounting for differences between serum and plasma: An indirect approach to derive reference intervals for total protein, albumin, and globulin
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T21%3A53%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Accounting%20for%20differences%20between%20serum%20and%20plasma:%20An%20indirect%20approach%20to%20derive%20reference%20intervals%20for%20total%20protein,%20albumin,%20and%20globulin&rft.jtitle=Clinica%20chimica%20acta&rft.au=Militello,%20Leah&rft.date=2024-08-15&rft.volume=562&rft.spage=119851&rft.pages=119851-&rft.artnum=119851&rft.issn=0009-8981&rft.eissn=1873-3492&rft_id=info:doi/10.1016/j.cca.2024.119851&rft_dat=%3Cproquest_cross%3E3077176012%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3077176012&rft_id=info:pmid/38977172&rft_els_id=S000989812402103X&rfr_iscdi=true