Reliable Determination of Contact Angle from the Liquid Fence

Traditional methods of measuring contact angles often face difficulties in precisely defining the three-phase contact points. A novel method for accurately defining three-phase contact points based on liquid fences is proposed in this article. The tested liquid is placed in a cubic liquid fence comp...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Langmuir 2024-06, Vol.40 (24), p.12459-12464
Hauptverfasser: Chen, Tao, Li, Linfeng, Guan, Jianfei, Shang, Xiuting, Yang, Zhengxuan, Gu, Lingcheng, Xu, Rongqing, Chen, Jing
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 12464
container_issue 24
container_start_page 12459
container_title Langmuir
container_volume 40
creator Chen, Tao
Li, Linfeng
Guan, Jianfei
Shang, Xiuting
Yang, Zhengxuan
Gu, Lingcheng
Xu, Rongqing
Chen, Jing
description Traditional methods of measuring contact angles often face difficulties in precisely defining the three-phase contact points. A novel method for accurately defining three-phase contact points based on liquid fences is proposed in this article. The tested liquid is placed in a cubic liquid fence composed of a pair of narrow strips of the tested solid and a pair of transparent wide strips. The transparent wide strip serves as the measurement window, and the surface tension of the liquid on it can be almost ignored. In experimental measurements, the horizontal coordinates of the end points of the liquid profile are fixed by the liquid fence, thus determining the horizontal coordinates of the three-phase contact points, which helps to accurately survey the contact angle. Additionally, since the parameters of the liquid fence are known, the size of the contact angle can also be calculated by measuring the height of the liquid level dome inside the liquid fence. Using the electric wetting effect as an example, we experimentally extracted a series of liquid contour maps with circular tops and square columns under varying voltages. The relationship curve between contact angle and voltage variation was obtained using the above methods, and a contact angle variation tendency seemed to agree well with the theoretical value.
doi_str_mv 10.1021/acs.langmuir.4c00836
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3064580511</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3064580511</sourcerecordid><originalsourceid>FETCH-LOGICAL-a227t-dca226d032d39363b4cf7accb45d3303043f54a4dac3e083d6b18f4def43027c3</originalsourceid><addsrcrecordid>eNp9kEtPwzAQhC0EoqXwDxDKkUvK2us8euBQFQpIlZAQnCPHj-IqiVs7OfDvcdWWI6c57Mys5iPklsKUAqMPQoZpI7p1O1g_5RKgxPyMjGnGIM1KVpyTMRQc04LnOCJXIWwAYIZ8dklGWJZsVjA-Jo8furGibnTypHvtW9uJ3roucSZZuK4Xsk_m3TqejXdt0n_rZGV3g1XJUndSX5MLI5qgb446IV_L58_Fa7p6f3lbzFepYKzoUyWj5gqQKZxhjjWXphBS1jxTiIDA0WRccCUk6rhD5TUtDVfacARWSJyQ-0Pv1rvdoENftTZI3cT92g2hQsh5VkJGabTyg1V6F4LXptp62wr_U1Go9uCqCK46gauO4GLs7vhhqFut_kInUtEAB8M-vnGD7-Lg_zt_ATgEfJI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3064580511</pqid></control><display><type>article</type><title>Reliable Determination of Contact Angle from the Liquid Fence</title><source>American Chemical Society Journals</source><creator>Chen, Tao ; Li, Linfeng ; Guan, Jianfei ; Shang, Xiuting ; Yang, Zhengxuan ; Gu, Lingcheng ; Xu, Rongqing ; Chen, Jing</creator><creatorcontrib>Chen, Tao ; Li, Linfeng ; Guan, Jianfei ; Shang, Xiuting ; Yang, Zhengxuan ; Gu, Lingcheng ; Xu, Rongqing ; Chen, Jing</creatorcontrib><description>Traditional methods of measuring contact angles often face difficulties in precisely defining the three-phase contact points. A novel method for accurately defining three-phase contact points based on liquid fences is proposed in this article. The tested liquid is placed in a cubic liquid fence composed of a pair of narrow strips of the tested solid and a pair of transparent wide strips. The transparent wide strip serves as the measurement window, and the surface tension of the liquid on it can be almost ignored. In experimental measurements, the horizontal coordinates of the end points of the liquid profile are fixed by the liquid fence, thus determining the horizontal coordinates of the three-phase contact points, which helps to accurately survey the contact angle. Additionally, since the parameters of the liquid fence are known, the size of the contact angle can also be calculated by measuring the height of the liquid level dome inside the liquid fence. Using the electric wetting effect as an example, we experimentally extracted a series of liquid contour maps with circular tops and square columns under varying voltages. The relationship curve between contact angle and voltage variation was obtained using the above methods, and a contact angle variation tendency seemed to agree well with the theoretical value.</description><identifier>ISSN: 0743-7463</identifier><identifier>ISSN: 1520-5827</identifier><identifier>EISSN: 1520-5827</identifier><identifier>DOI: 10.1021/acs.langmuir.4c00836</identifier><identifier>PMID: 38829724</identifier><language>eng</language><publisher>United States: American Chemical Society</publisher><ispartof>Langmuir, 2024-06, Vol.40 (24), p.12459-12464</ispartof><rights>2024 American Chemical Society</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-a227t-dca226d032d39363b4cf7accb45d3303043f54a4dac3e083d6b18f4def43027c3</cites><orcidid>0000-0002-0525-5374</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://pubs.acs.org/doi/pdf/10.1021/acs.langmuir.4c00836$$EPDF$$P50$$Gacs$$H</linktopdf><linktohtml>$$Uhttps://pubs.acs.org/doi/10.1021/acs.langmuir.4c00836$$EHTML$$P50$$Gacs$$H</linktohtml><link.rule.ids>314,780,784,2765,27076,27924,27925,56738,56788</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38829724$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Chen, Tao</creatorcontrib><creatorcontrib>Li, Linfeng</creatorcontrib><creatorcontrib>Guan, Jianfei</creatorcontrib><creatorcontrib>Shang, Xiuting</creatorcontrib><creatorcontrib>Yang, Zhengxuan</creatorcontrib><creatorcontrib>Gu, Lingcheng</creatorcontrib><creatorcontrib>Xu, Rongqing</creatorcontrib><creatorcontrib>Chen, Jing</creatorcontrib><title>Reliable Determination of Contact Angle from the Liquid Fence</title><title>Langmuir</title><addtitle>Langmuir</addtitle><description>Traditional methods of measuring contact angles often face difficulties in precisely defining the three-phase contact points. A novel method for accurately defining three-phase contact points based on liquid fences is proposed in this article. The tested liquid is placed in a cubic liquid fence composed of a pair of narrow strips of the tested solid and a pair of transparent wide strips. The transparent wide strip serves as the measurement window, and the surface tension of the liquid on it can be almost ignored. In experimental measurements, the horizontal coordinates of the end points of the liquid profile are fixed by the liquid fence, thus determining the horizontal coordinates of the three-phase contact points, which helps to accurately survey the contact angle. Additionally, since the parameters of the liquid fence are known, the size of the contact angle can also be calculated by measuring the height of the liquid level dome inside the liquid fence. Using the electric wetting effect as an example, we experimentally extracted a series of liquid contour maps with circular tops and square columns under varying voltages. The relationship curve between contact angle and voltage variation was obtained using the above methods, and a contact angle variation tendency seemed to agree well with the theoretical value.</description><issn>0743-7463</issn><issn>1520-5827</issn><issn>1520-5827</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kEtPwzAQhC0EoqXwDxDKkUvK2us8euBQFQpIlZAQnCPHj-IqiVs7OfDvcdWWI6c57Mys5iPklsKUAqMPQoZpI7p1O1g_5RKgxPyMjGnGIM1KVpyTMRQc04LnOCJXIWwAYIZ8dklGWJZsVjA-Jo8furGibnTypHvtW9uJ3roucSZZuK4Xsk_m3TqejXdt0n_rZGV3g1XJUndSX5MLI5qgb446IV_L58_Fa7p6f3lbzFepYKzoUyWj5gqQKZxhjjWXphBS1jxTiIDA0WRccCUk6rhD5TUtDVfacARWSJyQ-0Pv1rvdoENftTZI3cT92g2hQsh5VkJGabTyg1V6F4LXptp62wr_U1Go9uCqCK46gauO4GLs7vhhqFut_kInUtEAB8M-vnGD7-Lg_zt_ATgEfJI</recordid><startdate>20240618</startdate><enddate>20240618</enddate><creator>Chen, Tao</creator><creator>Li, Linfeng</creator><creator>Guan, Jianfei</creator><creator>Shang, Xiuting</creator><creator>Yang, Zhengxuan</creator><creator>Gu, Lingcheng</creator><creator>Xu, Rongqing</creator><creator>Chen, Jing</creator><general>American Chemical Society</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-0525-5374</orcidid></search><sort><creationdate>20240618</creationdate><title>Reliable Determination of Contact Angle from the Liquid Fence</title><author>Chen, Tao ; Li, Linfeng ; Guan, Jianfei ; Shang, Xiuting ; Yang, Zhengxuan ; Gu, Lingcheng ; Xu, Rongqing ; Chen, Jing</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a227t-dca226d032d39363b4cf7accb45d3303043f54a4dac3e083d6b18f4def43027c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chen, Tao</creatorcontrib><creatorcontrib>Li, Linfeng</creatorcontrib><creatorcontrib>Guan, Jianfei</creatorcontrib><creatorcontrib>Shang, Xiuting</creatorcontrib><creatorcontrib>Yang, Zhengxuan</creatorcontrib><creatorcontrib>Gu, Lingcheng</creatorcontrib><creatorcontrib>Xu, Rongqing</creatorcontrib><creatorcontrib>Chen, Jing</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Langmuir</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chen, Tao</au><au>Li, Linfeng</au><au>Guan, Jianfei</au><au>Shang, Xiuting</au><au>Yang, Zhengxuan</au><au>Gu, Lingcheng</au><au>Xu, Rongqing</au><au>Chen, Jing</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reliable Determination of Contact Angle from the Liquid Fence</atitle><jtitle>Langmuir</jtitle><addtitle>Langmuir</addtitle><date>2024-06-18</date><risdate>2024</risdate><volume>40</volume><issue>24</issue><spage>12459</spage><epage>12464</epage><pages>12459-12464</pages><issn>0743-7463</issn><issn>1520-5827</issn><eissn>1520-5827</eissn><abstract>Traditional methods of measuring contact angles often face difficulties in precisely defining the three-phase contact points. A novel method for accurately defining three-phase contact points based on liquid fences is proposed in this article. The tested liquid is placed in a cubic liquid fence composed of a pair of narrow strips of the tested solid and a pair of transparent wide strips. The transparent wide strip serves as the measurement window, and the surface tension of the liquid on it can be almost ignored. In experimental measurements, the horizontal coordinates of the end points of the liquid profile are fixed by the liquid fence, thus determining the horizontal coordinates of the three-phase contact points, which helps to accurately survey the contact angle. Additionally, since the parameters of the liquid fence are known, the size of the contact angle can also be calculated by measuring the height of the liquid level dome inside the liquid fence. Using the electric wetting effect as an example, we experimentally extracted a series of liquid contour maps with circular tops and square columns under varying voltages. The relationship curve between contact angle and voltage variation was obtained using the above methods, and a contact angle variation tendency seemed to agree well with the theoretical value.</abstract><cop>United States</cop><pub>American Chemical Society</pub><pmid>38829724</pmid><doi>10.1021/acs.langmuir.4c00836</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0002-0525-5374</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0743-7463
ispartof Langmuir, 2024-06, Vol.40 (24), p.12459-12464
issn 0743-7463
1520-5827
1520-5827
language eng
recordid cdi_proquest_miscellaneous_3064580511
source American Chemical Society Journals
title Reliable Determination of Contact Angle from the Liquid Fence
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T08%3A18%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reliable%20Determination%20of%20Contact%20Angle%20from%20the%20Liquid%20Fence&rft.jtitle=Langmuir&rft.au=Chen,%20Tao&rft.date=2024-06-18&rft.volume=40&rft.issue=24&rft.spage=12459&rft.epage=12464&rft.pages=12459-12464&rft.issn=0743-7463&rft.eissn=1520-5827&rft_id=info:doi/10.1021/acs.langmuir.4c00836&rft_dat=%3Cproquest_cross%3E3064580511%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3064580511&rft_id=info:pmid/38829724&rfr_iscdi=true