Effects of a Long-Acting Diquafosol Ophthalmic Solution on the Ocular Surface, Tolerability, and Usability in Dry Eye Disease

Introduction This study aimed to investigate the tolerability of high-viscosity diquafosol tetrasodium (DQS) ophthalmic solution (DIQUAS LX; DQSLX) and examine its usability and effect on clinical findings in patients with dry eye disease (DED). Methods This interventional retrospective study includ...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Advances in therapy 2024-06, Vol.41 (6), p.2477-2485
Hauptverfasser: Kaido, Minako, Arita, Reiko
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Introduction This study aimed to investigate the tolerability of high-viscosity diquafosol tetrasodium (DQS) ophthalmic solution (DIQUAS LX; DQSLX) and examine its usability and effect on clinical findings in patients with dry eye disease (DED). Methods This interventional retrospective study included 66 eyes of 66 patients with DED who switched from conventional DQS to DQSLX ophthalmic solution. Tear function assessments (tear film breakup time [BUT], keratoconjunctival vital staining [VS] score), evaluations of DED symptom relief, and a four-item usability questionnaire (“comfort upon instillation,” “irritation upon instillation,” “eye mucus discharge,” “convenience of instillation frequency”) assessed using a visual analog scale from 0 (worst) to 10 (best) were administered 4 weeks after switching to DQSLX. Factors associated with drug tolerability were assessed using multiple regression analysis. Results The symptoms improved by 64.2% after switching to DQSLX. The BUT value, VS score, and the questionnaire items “comfort upon instillation” and “convenience of instillation frequency” were significantly improved after switching to DQSLX. DQSLX tolerability was reported as acceptable in 56 (84.8%) and unacceptable in 10 (15.2%) patients. Overall, DQSLX tolerability was significantly associated with “comfort upon instillation” and “convenience of instillation frequency” and tended to be associated with a VS score ≥ 1. DQSLX tolerability depended on symptom and VS score improvements and absence of excessive “eye mucus discharge” in patients with a VS score ≥ 1 (39 patients), but on “comfort upon instillation” and absence of excessive “eye mucus discharge” in patients with a VS score = 0 (27 patients). Conclusion The high-viscosity DQSLX ophthalmic solution was generally considered acceptable in the study population. However, drug tolerability seemingly differed between patients with DED with and without epithelial damage. The former were affected by improvements in symptoms and clinical findings, whereas the latter were affected by comfort upon instillation. Trial Registration University Hospital Medical Information Network identifier, UMIN000051390.
ISSN:0741-238X
1865-8652
DOI:10.1007/s12325-024-02871-4