Observation on the tilt and decentration of multifocal intraocular lens with optic capture in Berger space for pediatric cataract

Purpose This study aimed to observe the tilt and decentration of multifocal intraocular lens (IOL) with optic capture in Berger space within 2 years after pediatric cataract surgery. Methods This is a prospective observational study. The implantation of multifocal IOL (Tecnis ZMB00) with optic captu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International ophthalmology 2024-04, Vol.44 (1), p.203-203, Article 203
Hauptverfasser: Fan, Zheng, Wang, Menghan, Peng, Yusu, Wang, Xiaoyun, Li, Dongfang, Ding, Yichao, Zhang, Jing, Huang, Yusen
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 203
container_issue 1
container_start_page 203
container_title International ophthalmology
container_volume 44
creator Fan, Zheng
Wang, Menghan
Peng, Yusu
Wang, Xiaoyun
Li, Dongfang
Ding, Yichao
Zhang, Jing
Huang, Yusen
description Purpose This study aimed to observe the tilt and decentration of multifocal intraocular lens (IOL) with optic capture in Berger space within 2 years after pediatric cataract surgery. Methods This is a prospective observational study. The implantation of multifocal IOL (Tecnis ZMB00) with optic capture in Berger space was performed on 33 patients (48 eyes) with pediatric cataract at Qingdao Eye Hospital. Tilt and decentration of IOL was measured using Scheimpflug system (Pentacam) at 1 month and 2 years postoperatively. Results All the multifocal IOLs were successfully implanted in Berger space with optic capture and no visually significant complications were detected during the follow-up. The mean tilt of IOLs was 2.779° ± 0.950° in the vertical plane and 2.399° ± 0.898° in the horizontal plane at 1 month postoperatively, and the mean length of the decentration was 0.207 ± 0.081 mm in vertical plane and 0.211 ± 0.090 mm in the horizontal plane. Compared with 1 month after surgery, the angle of tilt decreased by a mean of 0.192° and decentration increased by a mean of 0.014 mm at the vertical meridian at 2 years postoperatively ( P  = 0.37 and P  = 0.27, respectively), meanwhile, tilt increased by 0.265° and decentration increased by 0.012 mm at the horizontal meridian ( P  = 0.11 and P  = 0.22, respectively). Conclusions The follow-up results suggest the tilt and decentration of multifocal IOL implantation with optic capture in Berger space remain stable in an acceptable range within 2 years after cataract surgery in children above the age of 5. Trial registration :The study was approved by the Ethics Committee of Qingdao Eye Hospital, and registered on Chinese Clinical Trial Registry (ChiCTR identifier: 1900023155).
doi_str_mv 10.1007/s10792-024-03130-9
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3047939418</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3046998579</sourcerecordid><originalsourceid>FETCH-LOGICAL-c326t-af1210dd0d08a5e677dacd519c195a4ef9586441b5d9e7eb978cc75fe109867a3</originalsourceid><addsrcrecordid>eNp9kU1P3DAQhi1UVOi2f6CHylIvXELHcRLHxxYBrYTEhZ6tWXsCRtk4tZ1WHPnneNnthzhUsjSW55l3PPMy9l7AqQBQn5IApesK6qYCKSRU-oAdi1bJqu4kvPrnfsTepHQPAFrp7jU7kn2nhNDtMXu8XieKPzH7MPFy8h3x7MfMcXLckaUpx31y4JtlzH4IFkfut-_BLiNGPtKU-C-f73iYs7fc4pyXSIXhXyjeUuRpRkt8CJHP5Dzm-ExljGjzW3Y44Jjo3T6u2PeL85uzr9XV9eW3s89XlZV1lyscRC3AOXDQY0udUg6ta4W2ZQ5saNBt3zWNWLdOk6K1Vr21qh1IgC7Tolyxk53uHMOPhVI2G58sjSNOFJZkJDRKS92IvqAfX6D3YYlT-d2W6rTu24KuWL2jbAwpRRrMHP0G44MRYLYGmZ1Bphhkng0y26IPe-llvSH3p-S3IwWQOyCV1FSW97f3f2SfAH2inT4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3046998579</pqid></control><display><type>article</type><title>Observation on the tilt and decentration of multifocal intraocular lens with optic capture in Berger space for pediatric cataract</title><source>MEDLINE</source><source>SpringerLink Journals</source><creator>Fan, Zheng ; Wang, Menghan ; Peng, Yusu ; Wang, Xiaoyun ; Li, Dongfang ; Ding, Yichao ; Zhang, Jing ; Huang, Yusen</creator><creatorcontrib>Fan, Zheng ; Wang, Menghan ; Peng, Yusu ; Wang, Xiaoyun ; Li, Dongfang ; Ding, Yichao ; Zhang, Jing ; Huang, Yusen</creatorcontrib><description>Purpose This study aimed to observe the tilt and decentration of multifocal intraocular lens (IOL) with optic capture in Berger space within 2 years after pediatric cataract surgery. Methods This is a prospective observational study. The implantation of multifocal IOL (Tecnis ZMB00) with optic capture in Berger space was performed on 33 patients (48 eyes) with pediatric cataract at Qingdao Eye Hospital. Tilt and decentration of IOL was measured using Scheimpflug system (Pentacam) at 1 month and 2 years postoperatively. Results All the multifocal IOLs were successfully implanted in Berger space with optic capture and no visually significant complications were detected during the follow-up. The mean tilt of IOLs was 2.779° ± 0.950° in the vertical plane and 2.399° ± 0.898° in the horizontal plane at 1 month postoperatively, and the mean length of the decentration was 0.207 ± 0.081 mm in vertical plane and 0.211 ± 0.090 mm in the horizontal plane. Compared with 1 month after surgery, the angle of tilt decreased by a mean of 0.192° and decentration increased by a mean of 0.014 mm at the vertical meridian at 2 years postoperatively ( P  = 0.37 and P  = 0.27, respectively), meanwhile, tilt increased by 0.265° and decentration increased by 0.012 mm at the horizontal meridian ( P  = 0.11 and P  = 0.22, respectively). Conclusions The follow-up results suggest the tilt and decentration of multifocal IOL implantation with optic capture in Berger space remain stable in an acceptable range within 2 years after cataract surgery in children above the age of 5. Trial registration :The study was approved by the Ethics Committee of Qingdao Eye Hospital, and registered on Chinese Clinical Trial Registry (ChiCTR identifier: 1900023155).</description><identifier>ISSN: 1573-2630</identifier><identifier>ISSN: 0165-5701</identifier><identifier>EISSN: 1573-2630</identifier><identifier>DOI: 10.1007/s10792-024-03130-9</identifier><identifier>PMID: 38671195</identifier><language>eng</language><publisher>Dordrecht: Springer Netherlands</publisher><subject>Artificial Lens Implant Migration - diagnosis ; Artificial Lens Implant Migration - etiology ; Artificial Lens Implant Migration - physiopathology ; Artificial Lens Implant Migration - surgery ; Cataract - complications ; Cataract - physiopathology ; Cataract Extraction - adverse effects ; Cataract Extraction - methods ; Cataracts ; Child ; Child, Preschool ; Eye ; Eye surgery ; Female ; Follow-Up Studies ; Hospitals ; Humans ; Implantation ; Infant ; Intraocular lenses ; Lens Implantation, Intraocular - methods ; Male ; Medicine ; Medicine &amp; Public Health ; Multifocal Intraocular Lenses ; Observational studies ; Ophthalmology ; Original Paper ; Pediatrics ; Prospective Studies ; Prosthesis Design ; Surgery ; Visual Acuity</subject><ispartof>International ophthalmology, 2024-04, Vol.44 (1), p.203-203, Article 203</ispartof><rights>The Author(s), under exclusive licence to Springer Nature B.V. 2024. Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.</rights><rights>2024. The Author(s), under exclusive licence to Springer Nature B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c326t-af1210dd0d08a5e677dacd519c195a4ef9586441b5d9e7eb978cc75fe109867a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s10792-024-03130-9$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s10792-024-03130-9$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,41488,42557,51319</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38671195$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Fan, Zheng</creatorcontrib><creatorcontrib>Wang, Menghan</creatorcontrib><creatorcontrib>Peng, Yusu</creatorcontrib><creatorcontrib>Wang, Xiaoyun</creatorcontrib><creatorcontrib>Li, Dongfang</creatorcontrib><creatorcontrib>Ding, Yichao</creatorcontrib><creatorcontrib>Zhang, Jing</creatorcontrib><creatorcontrib>Huang, Yusen</creatorcontrib><title>Observation on the tilt and decentration of multifocal intraocular lens with optic capture in Berger space for pediatric cataract</title><title>International ophthalmology</title><addtitle>Int Ophthalmol</addtitle><addtitle>Int Ophthalmol</addtitle><description>Purpose This study aimed to observe the tilt and decentration of multifocal intraocular lens (IOL) with optic capture in Berger space within 2 years after pediatric cataract surgery. Methods This is a prospective observational study. The implantation of multifocal IOL (Tecnis ZMB00) with optic capture in Berger space was performed on 33 patients (48 eyes) with pediatric cataract at Qingdao Eye Hospital. Tilt and decentration of IOL was measured using Scheimpflug system (Pentacam) at 1 month and 2 years postoperatively. Results All the multifocal IOLs were successfully implanted in Berger space with optic capture and no visually significant complications were detected during the follow-up. The mean tilt of IOLs was 2.779° ± 0.950° in the vertical plane and 2.399° ± 0.898° in the horizontal plane at 1 month postoperatively, and the mean length of the decentration was 0.207 ± 0.081 mm in vertical plane and 0.211 ± 0.090 mm in the horizontal plane. Compared with 1 month after surgery, the angle of tilt decreased by a mean of 0.192° and decentration increased by a mean of 0.014 mm at the vertical meridian at 2 years postoperatively ( P  = 0.37 and P  = 0.27, respectively), meanwhile, tilt increased by 0.265° and decentration increased by 0.012 mm at the horizontal meridian ( P  = 0.11 and P  = 0.22, respectively). Conclusions The follow-up results suggest the tilt and decentration of multifocal IOL implantation with optic capture in Berger space remain stable in an acceptable range within 2 years after cataract surgery in children above the age of 5. Trial registration :The study was approved by the Ethics Committee of Qingdao Eye Hospital, and registered on Chinese Clinical Trial Registry (ChiCTR identifier: 1900023155).</description><subject>Artificial Lens Implant Migration - diagnosis</subject><subject>Artificial Lens Implant Migration - etiology</subject><subject>Artificial Lens Implant Migration - physiopathology</subject><subject>Artificial Lens Implant Migration - surgery</subject><subject>Cataract - complications</subject><subject>Cataract - physiopathology</subject><subject>Cataract Extraction - adverse effects</subject><subject>Cataract Extraction - methods</subject><subject>Cataracts</subject><subject>Child</subject><subject>Child, Preschool</subject><subject>Eye</subject><subject>Eye surgery</subject><subject>Female</subject><subject>Follow-Up Studies</subject><subject>Hospitals</subject><subject>Humans</subject><subject>Implantation</subject><subject>Infant</subject><subject>Intraocular lenses</subject><subject>Lens Implantation, Intraocular - methods</subject><subject>Male</subject><subject>Medicine</subject><subject>Medicine &amp; Public Health</subject><subject>Multifocal Intraocular Lenses</subject><subject>Observational studies</subject><subject>Ophthalmology</subject><subject>Original Paper</subject><subject>Pediatrics</subject><subject>Prospective Studies</subject><subject>Prosthesis Design</subject><subject>Surgery</subject><subject>Visual Acuity</subject><issn>1573-2630</issn><issn>0165-5701</issn><issn>1573-2630</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kU1P3DAQhi1UVOi2f6CHylIvXELHcRLHxxYBrYTEhZ6tWXsCRtk4tZ1WHPnneNnthzhUsjSW55l3PPMy9l7AqQBQn5IApesK6qYCKSRU-oAdi1bJqu4kvPrnfsTepHQPAFrp7jU7kn2nhNDtMXu8XieKPzH7MPFy8h3x7MfMcXLckaUpx31y4JtlzH4IFkfut-_BLiNGPtKU-C-f73iYs7fc4pyXSIXhXyjeUuRpRkt8CJHP5Dzm-ExljGjzW3Y44Jjo3T6u2PeL85uzr9XV9eW3s89XlZV1lyscRC3AOXDQY0udUg6ta4W2ZQ5saNBt3zWNWLdOk6K1Vr21qh1IgC7Tolyxk53uHMOPhVI2G58sjSNOFJZkJDRKS92IvqAfX6D3YYlT-d2W6rTu24KuWL2jbAwpRRrMHP0G44MRYLYGmZ1Bphhkng0y26IPe-llvSH3p-S3IwWQOyCV1FSW97f3f2SfAH2inT4</recordid><startdate>20240426</startdate><enddate>20240426</enddate><creator>Fan, Zheng</creator><creator>Wang, Menghan</creator><creator>Peng, Yusu</creator><creator>Wang, Xiaoyun</creator><creator>Li, Dongfang</creator><creator>Ding, Yichao</creator><creator>Zhang, Jing</creator><creator>Huang, Yusen</creator><general>Springer Netherlands</general><general>Springer Nature B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QL</scope><scope>7T7</scope><scope>7TK</scope><scope>7U9</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>H94</scope><scope>K9.</scope><scope>M7N</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>20240426</creationdate><title>Observation on the tilt and decentration of multifocal intraocular lens with optic capture in Berger space for pediatric cataract</title><author>Fan, Zheng ; Wang, Menghan ; Peng, Yusu ; Wang, Xiaoyun ; Li, Dongfang ; Ding, Yichao ; Zhang, Jing ; Huang, Yusen</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c326t-af1210dd0d08a5e677dacd519c195a4ef9586441b5d9e7eb978cc75fe109867a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Artificial Lens Implant Migration - diagnosis</topic><topic>Artificial Lens Implant Migration - etiology</topic><topic>Artificial Lens Implant Migration - physiopathology</topic><topic>Artificial Lens Implant Migration - surgery</topic><topic>Cataract - complications</topic><topic>Cataract - physiopathology</topic><topic>Cataract Extraction - adverse effects</topic><topic>Cataract Extraction - methods</topic><topic>Cataracts</topic><topic>Child</topic><topic>Child, Preschool</topic><topic>Eye</topic><topic>Eye surgery</topic><topic>Female</topic><topic>Follow-Up Studies</topic><topic>Hospitals</topic><topic>Humans</topic><topic>Implantation</topic><topic>Infant</topic><topic>Intraocular lenses</topic><topic>Lens Implantation, Intraocular - methods</topic><topic>Male</topic><topic>Medicine</topic><topic>Medicine &amp; Public Health</topic><topic>Multifocal Intraocular Lenses</topic><topic>Observational studies</topic><topic>Ophthalmology</topic><topic>Original Paper</topic><topic>Pediatrics</topic><topic>Prospective Studies</topic><topic>Prosthesis Design</topic><topic>Surgery</topic><topic>Visual Acuity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fan, Zheng</creatorcontrib><creatorcontrib>Wang, Menghan</creatorcontrib><creatorcontrib>Peng, Yusu</creatorcontrib><creatorcontrib>Wang, Xiaoyun</creatorcontrib><creatorcontrib>Li, Dongfang</creatorcontrib><creatorcontrib>Ding, Yichao</creatorcontrib><creatorcontrib>Zhang, Jing</creatorcontrib><creatorcontrib>Huang, Yusen</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Bacteriology Abstracts (Microbiology B)</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Neurosciences Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Algology Mycology and Protozoology Abstracts (Microbiology C)</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>International ophthalmology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Fan, Zheng</au><au>Wang, Menghan</au><au>Peng, Yusu</au><au>Wang, Xiaoyun</au><au>Li, Dongfang</au><au>Ding, Yichao</au><au>Zhang, Jing</au><au>Huang, Yusen</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Observation on the tilt and decentration of multifocal intraocular lens with optic capture in Berger space for pediatric cataract</atitle><jtitle>International ophthalmology</jtitle><stitle>Int Ophthalmol</stitle><addtitle>Int Ophthalmol</addtitle><date>2024-04-26</date><risdate>2024</risdate><volume>44</volume><issue>1</issue><spage>203</spage><epage>203</epage><pages>203-203</pages><artnum>203</artnum><issn>1573-2630</issn><issn>0165-5701</issn><eissn>1573-2630</eissn><abstract>Purpose This study aimed to observe the tilt and decentration of multifocal intraocular lens (IOL) with optic capture in Berger space within 2 years after pediatric cataract surgery. Methods This is a prospective observational study. The implantation of multifocal IOL (Tecnis ZMB00) with optic capture in Berger space was performed on 33 patients (48 eyes) with pediatric cataract at Qingdao Eye Hospital. Tilt and decentration of IOL was measured using Scheimpflug system (Pentacam) at 1 month and 2 years postoperatively. Results All the multifocal IOLs were successfully implanted in Berger space with optic capture and no visually significant complications were detected during the follow-up. The mean tilt of IOLs was 2.779° ± 0.950° in the vertical plane and 2.399° ± 0.898° in the horizontal plane at 1 month postoperatively, and the mean length of the decentration was 0.207 ± 0.081 mm in vertical plane and 0.211 ± 0.090 mm in the horizontal plane. Compared with 1 month after surgery, the angle of tilt decreased by a mean of 0.192° and decentration increased by a mean of 0.014 mm at the vertical meridian at 2 years postoperatively ( P  = 0.37 and P  = 0.27, respectively), meanwhile, tilt increased by 0.265° and decentration increased by 0.012 mm at the horizontal meridian ( P  = 0.11 and P  = 0.22, respectively). Conclusions The follow-up results suggest the tilt and decentration of multifocal IOL implantation with optic capture in Berger space remain stable in an acceptable range within 2 years after cataract surgery in children above the age of 5. Trial registration :The study was approved by the Ethics Committee of Qingdao Eye Hospital, and registered on Chinese Clinical Trial Registry (ChiCTR identifier: 1900023155).</abstract><cop>Dordrecht</cop><pub>Springer Netherlands</pub><pmid>38671195</pmid><doi>10.1007/s10792-024-03130-9</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1573-2630
ispartof International ophthalmology, 2024-04, Vol.44 (1), p.203-203, Article 203
issn 1573-2630
0165-5701
1573-2630
language eng
recordid cdi_proquest_miscellaneous_3047939418
source MEDLINE; SpringerLink Journals
subjects Artificial Lens Implant Migration - diagnosis
Artificial Lens Implant Migration - etiology
Artificial Lens Implant Migration - physiopathology
Artificial Lens Implant Migration - surgery
Cataract - complications
Cataract - physiopathology
Cataract Extraction - adverse effects
Cataract Extraction - methods
Cataracts
Child
Child, Preschool
Eye
Eye surgery
Female
Follow-Up Studies
Hospitals
Humans
Implantation
Infant
Intraocular lenses
Lens Implantation, Intraocular - methods
Male
Medicine
Medicine & Public Health
Multifocal Intraocular Lenses
Observational studies
Ophthalmology
Original Paper
Pediatrics
Prospective Studies
Prosthesis Design
Surgery
Visual Acuity
title Observation on the tilt and decentration of multifocal intraocular lens with optic capture in Berger space for pediatric cataract
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T14%3A50%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Observation%20on%20the%20tilt%20and%20decentration%20of%20multifocal%20intraocular%20lens%20with%20optic%20capture%20in%20Berger%20space%20for%20pediatric%20cataract&rft.jtitle=International%20ophthalmology&rft.au=Fan,%20Zheng&rft.date=2024-04-26&rft.volume=44&rft.issue=1&rft.spage=203&rft.epage=203&rft.pages=203-203&rft.artnum=203&rft.issn=1573-2630&rft.eissn=1573-2630&rft_id=info:doi/10.1007/s10792-024-03130-9&rft_dat=%3Cproquest_cross%3E3046998579%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3046998579&rft_id=info:pmid/38671195&rfr_iscdi=true