Assessment of Human Fetuses Undergoing Acute Pain: Validation of the Fetal-7 Scale

Improvements in fetal ultrasound have allowed for the diagnosis and treatment of fetal diseases in the uterus, often through surgery. However, little attention has been drawn to the assessment of fetal pain. To address this gap, a fetal pain scoring system, known as the Fetal-7 scale, was developed....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The journal of pain 2024-09, Vol.25 (9), p.104527, Article 104527
Hauptverfasser: Bernardes, Lisandra S., Fernandes, Ana M., Carvalho, Mariana A., Ottolia, Juliana, Hamani, Michele, Oliveira, Inaeh, Kubota, Gabriel T., da Silva, Valquíria A., Veloso, Adriano, de Carvalho, Mario H.B., de Amorim Filho, Antonio G., Arenholt, Louise T.S., Leutscher, Peter C., de Andrade, Daniel C.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Improvements in fetal ultrasound have allowed for the diagnosis and treatment of fetal diseases in the uterus, often through surgery. However, little attention has been drawn to the assessment of fetal pain. To address this gap, a fetal pain scoring system, known as the Fetal-7 scale, was developed. The present study is a full validation of the Fetal-7 scale. The validation involved 2 steps: 1) 4 fetuses with the indication of surgery were evaluated in 3 conditions perioperatively: acute pain, rest, and under loud sound stimulation. Facial expressions were assessed by 30 raters using screenshots from 4D high-definition ultrasound films; 2) assessment of sensitivity and specificity of the Fetal-7 scale in 54 healthy fetuses and 2 fetuses undergoing acute pain after preoperative anesthetic intramuscular injection. There was high internal consistency with Cronbach’s alpha (α) of .99. Intrarater reliability of the Fetal-7 scale (test-retest) calculated by intraclass correlation coefficient was .95, and inter-rater reliability was .99. The scale accurately differentiated between healthy fetuses at rest and those experiencing acute pain (sensitivity of 100% and specificity of 94.4%). The Fetal-7 scale is a valid tool for assessing acute pain-related behavior in third-trimester fetuses and may be of value in guiding analgesic procedures efficacy in these patients. Further research is warranted to explore the presence of postoperative pain in fetuses and its effects after birth. Recordings with 3-dimensional ultrasound of human fetuses undergoing preoperative anesthetic injections revealed complex facial expressions during acute pain, similar to those collected in newborns. This study presented the validation process and cut-off value of the Fetal-7 scale, paving the way for the study of pain before birth in humans. •The Fetal-7 scale is the first validated tool for assessing pain-related behavior in fetuses.•This scale demonstrated high internal consistency and high intra- and inter-rater reliabilities.•It detected acute fetal pain behavior with 100% sensitivity and 94.4% specificity.•The Fetal-7 scale may be useful for guiding analgesia among third-trimester fetuses.
ISSN:1526-5900
1528-8447
1528-8447