A Study on Development of the Total Hip Prosthesis Design Fitted for Japanese Patients (2nd Report, Shape Accuracy Estimation of the Femur CAD Model and Improvement in the Canal Fill Ratio of Prosthesis)

In order to devolop the total hip prosthesis design fitted for Japanese osteoar throsis (OA) femurs, the authors analyzed their canal shapes geometrically. The canal shapes of Japanese OA femurs were classified into three types, and prosthetic stem designs corresponded to each femur type were propos...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nihon Kikai Gakkai ronbunshū. A 2004-09, Vol.16 (9), p.1186-1192
Hauptverfasser: Sakamoto, Jiro, Oda, Juhachi, Hasegawa, Yukinori, Sugimori, Tanzou, Kaneuji, Ayumi, Matsumoto, Tadami, Nishino, Mitsuru, Fujita, Masahiko, Tomita, Katsuro
Format: Artikel
Sprache:jpn
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1192
container_issue 9
container_start_page 1186
container_title Nihon Kikai Gakkai ronbunshū. A
container_volume 16
creator Sakamoto, Jiro
Oda, Juhachi
Hasegawa, Yukinori
Sugimori, Tanzou
Kaneuji, Ayumi
Matsumoto, Tadami
Nishino, Mitsuru
Fujita, Masahiko
Tomita, Katsuro
description In order to devolop the total hip prosthesis design fitted for Japanese osteoar throsis (OA) femurs, the authors analyzed their canal shapes geometrically. The canal shapes of Japanese OA femurs were classified into three types, and prosthetic stem designs corresponded to each femur type were proposed in our previous paper. 3-dimensional CAD models of the proximal femurs based on computed topographic (CT) images were used in the classification and the design. Shape accuracy estimation of the CAD models is required to establish the classification. In this paper, femur CAD models were constructed from not only the CT Images but real images of sliced femur specimen, and proximal canal shapes of the models were compared each other in same coordinate. Shape differences of the models were estimated quantitatively, and accuracy of the model based on CT images was entablished. Furthermore, a prosthetic stem design was improved to increase fill rate of the stem to femoral canal. Finite-element analysis of proximal femur with the improved prosthesis was carried out. Stress distribution of bone around the stem was compared between case of the improved and previous design. Effect of increasing the canal fill ratio on the stress distribution was discussed.
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_30011729</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>30011729</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_300117293</originalsourceid><addsrcrecordid>eNqNjsFKw0AQhnNQaNG-w38SBQubhJp6DGlDFYTS9l7WZGIXNrvrzqbQZ_Sl3JaCV08Dw_fNfDfJWOTzYjoTYj5KJszqU4g8LVLxko2TnxLbMLQnWIMFHUlb15MJsB3CgbCzQWqslMPaW44bVhw5Vl8GtQqBWnTW4106aYgJaxlU1BmPmWmxIWd9eMb2IB2hbJrBy-aEJQfVRzC-vL6pqR88qnKBD9uShozyW--8PdKlRpkLVkkTa2qlNTZn_6z_dT3dJ7ed1EyT67xLHurlrlpN46HvgTjse8UNaR1b7cD7XIg0LbLX_N_gL6ttbOs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>30011729</pqid></control><display><type>article</type><title>A Study on Development of the Total Hip Prosthesis Design Fitted for Japanese Patients (2nd Report, Shape Accuracy Estimation of the Femur CAD Model and Improvement in the Canal Fill Ratio of Prosthesis)</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>J-STAGE (Japan Science &amp; Technology Information Aggregator, Electronic) Freely Available Titles - Japanese</source><creator>Sakamoto, Jiro ; Oda, Juhachi ; Hasegawa, Yukinori ; Sugimori, Tanzou ; Kaneuji, Ayumi ; Matsumoto, Tadami ; Nishino, Mitsuru ; Fujita, Masahiko ; Tomita, Katsuro</creator><creatorcontrib>Sakamoto, Jiro ; Oda, Juhachi ; Hasegawa, Yukinori ; Sugimori, Tanzou ; Kaneuji, Ayumi ; Matsumoto, Tadami ; Nishino, Mitsuru ; Fujita, Masahiko ; Tomita, Katsuro</creatorcontrib><description>In order to devolop the total hip prosthesis design fitted for Japanese osteoar throsis (OA) femurs, the authors analyzed their canal shapes geometrically. The canal shapes of Japanese OA femurs were classified into three types, and prosthetic stem designs corresponded to each femur type were proposed in our previous paper. 3-dimensional CAD models of the proximal femurs based on computed topographic (CT) images were used in the classification and the design. Shape accuracy estimation of the CAD models is required to establish the classification. In this paper, femur CAD models were constructed from not only the CT Images but real images of sliced femur specimen, and proximal canal shapes of the models were compared each other in same coordinate. Shape differences of the models were estimated quantitatively, and accuracy of the model based on CT images was entablished. Furthermore, a prosthetic stem design was improved to increase fill rate of the stem to femoral canal. Finite-element analysis of proximal femur with the improved prosthesis was carried out. Stress distribution of bone around the stem was compared between case of the improved and previous design. Effect of increasing the canal fill ratio on the stress distribution was discussed.</description><identifier>ISSN: 0387-5008</identifier><language>jpn</language><ispartof>Nihon Kikai Gakkai ronbunshū. A, 2004-09, Vol.16 (9), p.1186-1192</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785</link.rule.ids></links><search><creatorcontrib>Sakamoto, Jiro</creatorcontrib><creatorcontrib>Oda, Juhachi</creatorcontrib><creatorcontrib>Hasegawa, Yukinori</creatorcontrib><creatorcontrib>Sugimori, Tanzou</creatorcontrib><creatorcontrib>Kaneuji, Ayumi</creatorcontrib><creatorcontrib>Matsumoto, Tadami</creatorcontrib><creatorcontrib>Nishino, Mitsuru</creatorcontrib><creatorcontrib>Fujita, Masahiko</creatorcontrib><creatorcontrib>Tomita, Katsuro</creatorcontrib><title>A Study on Development of the Total Hip Prosthesis Design Fitted for Japanese Patients (2nd Report, Shape Accuracy Estimation of the Femur CAD Model and Improvement in the Canal Fill Ratio of Prosthesis)</title><title>Nihon Kikai Gakkai ronbunshū. A</title><description>In order to devolop the total hip prosthesis design fitted for Japanese osteoar throsis (OA) femurs, the authors analyzed their canal shapes geometrically. The canal shapes of Japanese OA femurs were classified into three types, and prosthetic stem designs corresponded to each femur type were proposed in our previous paper. 3-dimensional CAD models of the proximal femurs based on computed topographic (CT) images were used in the classification and the design. Shape accuracy estimation of the CAD models is required to establish the classification. In this paper, femur CAD models were constructed from not only the CT Images but real images of sliced femur specimen, and proximal canal shapes of the models were compared each other in same coordinate. Shape differences of the models were estimated quantitatively, and accuracy of the model based on CT images was entablished. Furthermore, a prosthetic stem design was improved to increase fill rate of the stem to femoral canal. Finite-element analysis of proximal femur with the improved prosthesis was carried out. Stress distribution of bone around the stem was compared between case of the improved and previous design. Effect of increasing the canal fill ratio on the stress distribution was discussed.</description><issn>0387-5008</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><recordid>eNqNjsFKw0AQhnNQaNG-w38SBQubhJp6DGlDFYTS9l7WZGIXNrvrzqbQZ_Sl3JaCV08Dw_fNfDfJWOTzYjoTYj5KJszqU4g8LVLxko2TnxLbMLQnWIMFHUlb15MJsB3CgbCzQWqslMPaW44bVhw5Vl8GtQqBWnTW4106aYgJaxlU1BmPmWmxIWd9eMb2IB2hbJrBy-aEJQfVRzC-vL6pqR88qnKBD9uShozyW--8PdKlRpkLVkkTa2qlNTZn_6z_dT3dJ7ed1EyT67xLHurlrlpN46HvgTjse8UNaR1b7cD7XIg0LbLX_N_gL6ttbOs</recordid><startdate>20040901</startdate><enddate>20040901</enddate><creator>Sakamoto, Jiro</creator><creator>Oda, Juhachi</creator><creator>Hasegawa, Yukinori</creator><creator>Sugimori, Tanzou</creator><creator>Kaneuji, Ayumi</creator><creator>Matsumoto, Tadami</creator><creator>Nishino, Mitsuru</creator><creator>Fujita, Masahiko</creator><creator>Tomita, Katsuro</creator><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope></search><sort><creationdate>20040901</creationdate><title>A Study on Development of the Total Hip Prosthesis Design Fitted for Japanese Patients (2nd Report, Shape Accuracy Estimation of the Femur CAD Model and Improvement in the Canal Fill Ratio of Prosthesis)</title><author>Sakamoto, Jiro ; Oda, Juhachi ; Hasegawa, Yukinori ; Sugimori, Tanzou ; Kaneuji, Ayumi ; Matsumoto, Tadami ; Nishino, Mitsuru ; Fujita, Masahiko ; Tomita, Katsuro</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_300117293</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>jpn</language><creationdate>2004</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Sakamoto, Jiro</creatorcontrib><creatorcontrib>Oda, Juhachi</creatorcontrib><creatorcontrib>Hasegawa, Yukinori</creatorcontrib><creatorcontrib>Sugimori, Tanzou</creatorcontrib><creatorcontrib>Kaneuji, Ayumi</creatorcontrib><creatorcontrib>Matsumoto, Tadami</creatorcontrib><creatorcontrib>Nishino, Mitsuru</creatorcontrib><creatorcontrib>Fujita, Masahiko</creatorcontrib><creatorcontrib>Tomita, Katsuro</creatorcontrib><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><jtitle>Nihon Kikai Gakkai ronbunshū. A</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sakamoto, Jiro</au><au>Oda, Juhachi</au><au>Hasegawa, Yukinori</au><au>Sugimori, Tanzou</au><au>Kaneuji, Ayumi</au><au>Matsumoto, Tadami</au><au>Nishino, Mitsuru</au><au>Fujita, Masahiko</au><au>Tomita, Katsuro</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Study on Development of the Total Hip Prosthesis Design Fitted for Japanese Patients (2nd Report, Shape Accuracy Estimation of the Femur CAD Model and Improvement in the Canal Fill Ratio of Prosthesis)</atitle><jtitle>Nihon Kikai Gakkai ronbunshū. A</jtitle><date>2004-09-01</date><risdate>2004</risdate><volume>16</volume><issue>9</issue><spage>1186</spage><epage>1192</epage><pages>1186-1192</pages><issn>0387-5008</issn><abstract>In order to devolop the total hip prosthesis design fitted for Japanese osteoar throsis (OA) femurs, the authors analyzed their canal shapes geometrically. The canal shapes of Japanese OA femurs were classified into three types, and prosthetic stem designs corresponded to each femur type were proposed in our previous paper. 3-dimensional CAD models of the proximal femurs based on computed topographic (CT) images were used in the classification and the design. Shape accuracy estimation of the CAD models is required to establish the classification. In this paper, femur CAD models were constructed from not only the CT Images but real images of sliced femur specimen, and proximal canal shapes of the models were compared each other in same coordinate. Shape differences of the models were estimated quantitatively, and accuracy of the model based on CT images was entablished. Furthermore, a prosthetic stem design was improved to increase fill rate of the stem to femoral canal. Finite-element analysis of proximal femur with the improved prosthesis was carried out. Stress distribution of bone around the stem was compared between case of the improved and previous design. Effect of increasing the canal fill ratio on the stress distribution was discussed.</abstract></addata></record>
fulltext fulltext
identifier ISSN: 0387-5008
ispartof Nihon Kikai Gakkai ronbunshū. A, 2004-09, Vol.16 (9), p.1186-1192
issn 0387-5008
language jpn
recordid cdi_proquest_miscellaneous_30011729
source Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; J-STAGE (Japan Science & Technology Information Aggregator, Electronic) Freely Available Titles - Japanese
title A Study on Development of the Total Hip Prosthesis Design Fitted for Japanese Patients (2nd Report, Shape Accuracy Estimation of the Femur CAD Model and Improvement in the Canal Fill Ratio of Prosthesis)
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-15T22%3A47%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Study%20on%20Development%20of%20the%20Total%20Hip%20Prosthesis%20Design%20Fitted%20for%20Japanese%20Patients%20(2nd%20Report,%20Shape%20Accuracy%20Estimation%20of%20the%20Femur%20CAD%20Model%20and%20Improvement%20in%20the%20Canal%20Fill%20Ratio%20of%20Prosthesis)&rft.jtitle=Nihon%20Kikai%20Gakkai%20ronbunsh%C5%AB.%20A&rft.au=Sakamoto,%20Jiro&rft.date=2004-09-01&rft.volume=16&rft.issue=9&rft.spage=1186&rft.epage=1192&rft.pages=1186-1192&rft.issn=0387-5008&rft_id=info:doi/&rft_dat=%3Cproquest%3E30011729%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=30011729&rft_id=info:pmid/&rfr_iscdi=true