Capacitance wire-mesh sensor for fast measurement of phase fraction distributions
We introduce a new wire-mesh sensor based on capacitance (permittivity) measurements. The sensor can be used to measure transient phase fraction distributions in a flow cross-section, such as in a pipe or other vessel, and is able to discriminate fluids having different relative permittivity (dielec...
Gespeichert in:
Veröffentlicht in: | Measurement science & technology 2007-07, Vol.18 (7), p.2245-2251 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 2251 |
---|---|
container_issue | 7 |
container_start_page | 2245 |
container_title | Measurement science & technology |
container_volume | 18 |
creator | Da Silva, M J Schleicher, E Hampel, U |
description | We introduce a new wire-mesh sensor based on capacitance (permittivity) measurements. The sensor can be used to measure transient phase fraction distributions in a flow cross-section, such as in a pipe or other vessel, and is able to discriminate fluids having different relative permittivity (dielectric constant) values in a multiphase flow. We designed and manufactured a prototype sensor which comprises two planes of 16 wires each. The wires are evenly distributed across the measuring cross-section, and measurement is performed at the wire crossings. Time resolution of the prototype sensor is 625 frames per second. Sensor and measuring electronics were evaluated showing good stability and accuracy in the capacitance measurement. The wire-mesh sensor was tested in a silicone oil/water two-phase bubbly flow. |
doi_str_mv | 10.1088/0957-0233/18/7/059 |
format | Article |
fullrecord | <record><control><sourceid>proquest_iop_p</sourceid><recordid>TN_cdi_proquest_miscellaneous_30005330</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>30005330</sourcerecordid><originalsourceid>FETCH-LOGICAL-c416t-27b0586ed9b192462a683616ce1bd0347e919e465b709bf8a4e607fd52f02cfd3</originalsourceid><addsrcrecordid>eNp9kE1LxDAQhoMouK7-AU85CR7qTtombY6y-AULIug5pOmEjWw_zLSI_96Wlb0seBhmBp53eOdl7FrAnYCyXIGWRQJplq1EuSpWIPUJW4hMiURJEKdscQDO2QXRJwAUoPWCva1tb10YbOuQf4eISYO05YQtdZH7uSwNvEFLY8QG24F3nvdbS8h9tG4IXcvrQEMM1TgvdMnOvN0RXv31Jft4fHhfPyeb16eX9f0mcblQQ5IWFchSYa0rodNcpVaVk1_lUFQ1ZHmBWmjMlawmo5UvbY4KCl_L1EPqfJ0t2c3-bh-7rxFpME0gh7udbbEbyWTTjzLLYALTPehiRxTRmz6GxsYfI8DM6Zk5HDOHY0RppknqSXS7F4WuP_DHnOlrP7HJMfvP7V8cKX1m</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>30005330</pqid></control><display><type>article</type><title>Capacitance wire-mesh sensor for fast measurement of phase fraction distributions</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Da Silva, M J ; Schleicher, E ; Hampel, U</creator><creatorcontrib>Da Silva, M J ; Schleicher, E ; Hampel, U</creatorcontrib><description>We introduce a new wire-mesh sensor based on capacitance (permittivity) measurements. The sensor can be used to measure transient phase fraction distributions in a flow cross-section, such as in a pipe or other vessel, and is able to discriminate fluids having different relative permittivity (dielectric constant) values in a multiphase flow. We designed and manufactured a prototype sensor which comprises two planes of 16 wires each. The wires are evenly distributed across the measuring cross-section, and measurement is performed at the wire crossings. Time resolution of the prototype sensor is 625 frames per second. Sensor and measuring electronics were evaluated showing good stability and accuracy in the capacitance measurement. The wire-mesh sensor was tested in a silicone oil/water two-phase bubbly flow.</description><identifier>ISSN: 0957-0233</identifier><identifier>EISSN: 1361-6501</identifier><identifier>DOI: 10.1088/0957-0233/18/7/059</identifier><language>eng</language><publisher>IOP Publishing</publisher><ispartof>Measurement science & technology, 2007-07, Vol.18 (7), p.2245-2251</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c416t-27b0586ed9b192462a683616ce1bd0347e919e465b709bf8a4e607fd52f02cfd3</citedby><cites>FETCH-LOGICAL-c416t-27b0586ed9b192462a683616ce1bd0347e919e465b709bf8a4e607fd52f02cfd3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/0957-0233/18/7/059/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,776,780,27901,27902,53805,53885</link.rule.ids></links><search><creatorcontrib>Da Silva, M J</creatorcontrib><creatorcontrib>Schleicher, E</creatorcontrib><creatorcontrib>Hampel, U</creatorcontrib><title>Capacitance wire-mesh sensor for fast measurement of phase fraction distributions</title><title>Measurement science & technology</title><description>We introduce a new wire-mesh sensor based on capacitance (permittivity) measurements. The sensor can be used to measure transient phase fraction distributions in a flow cross-section, such as in a pipe or other vessel, and is able to discriminate fluids having different relative permittivity (dielectric constant) values in a multiphase flow. We designed and manufactured a prototype sensor which comprises two planes of 16 wires each. The wires are evenly distributed across the measuring cross-section, and measurement is performed at the wire crossings. Time resolution of the prototype sensor is 625 frames per second. Sensor and measuring electronics were evaluated showing good stability and accuracy in the capacitance measurement. The wire-mesh sensor was tested in a silicone oil/water two-phase bubbly flow.</description><issn>0957-0233</issn><issn>1361-6501</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LxDAQhoMouK7-AU85CR7qTtombY6y-AULIug5pOmEjWw_zLSI_96Wlb0seBhmBp53eOdl7FrAnYCyXIGWRQJplq1EuSpWIPUJW4hMiURJEKdscQDO2QXRJwAUoPWCva1tb10YbOuQf4eISYO05YQtdZH7uSwNvEFLY8QG24F3nvdbS8h9tG4IXcvrQEMM1TgvdMnOvN0RXv31Jft4fHhfPyeb16eX9f0mcblQQ5IWFchSYa0rodNcpVaVk1_lUFQ1ZHmBWmjMlawmo5UvbY4KCl_L1EPqfJ0t2c3-bh-7rxFpME0gh7udbbEbyWTTjzLLYALTPehiRxTRmz6GxsYfI8DM6Zk5HDOHY0RppknqSXS7F4WuP_DHnOlrP7HJMfvP7V8cKX1m</recordid><startdate>20070701</startdate><enddate>20070701</enddate><creator>Da Silva, M J</creator><creator>Schleicher, E</creator><creator>Hampel, U</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope></search><sort><creationdate>20070701</creationdate><title>Capacitance wire-mesh sensor for fast measurement of phase fraction distributions</title><author>Da Silva, M J ; Schleicher, E ; Hampel, U</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c416t-27b0586ed9b192462a683616ce1bd0347e919e465b709bf8a4e607fd52f02cfd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Da Silva, M J</creatorcontrib><creatorcontrib>Schleicher, E</creatorcontrib><creatorcontrib>Hampel, U</creatorcontrib><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><jtitle>Measurement science & technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Da Silva, M J</au><au>Schleicher, E</au><au>Hampel, U</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Capacitance wire-mesh sensor for fast measurement of phase fraction distributions</atitle><jtitle>Measurement science & technology</jtitle><date>2007-07-01</date><risdate>2007</risdate><volume>18</volume><issue>7</issue><spage>2245</spage><epage>2251</epage><pages>2245-2251</pages><issn>0957-0233</issn><eissn>1361-6501</eissn><abstract>We introduce a new wire-mesh sensor based on capacitance (permittivity) measurements. The sensor can be used to measure transient phase fraction distributions in a flow cross-section, such as in a pipe or other vessel, and is able to discriminate fluids having different relative permittivity (dielectric constant) values in a multiphase flow. We designed and manufactured a prototype sensor which comprises two planes of 16 wires each. The wires are evenly distributed across the measuring cross-section, and measurement is performed at the wire crossings. Time resolution of the prototype sensor is 625 frames per second. Sensor and measuring electronics were evaluated showing good stability and accuracy in the capacitance measurement. The wire-mesh sensor was tested in a silicone oil/water two-phase bubbly flow.</abstract><pub>IOP Publishing</pub><doi>10.1088/0957-0233/18/7/059</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0957-0233 |
ispartof | Measurement science & technology, 2007-07, Vol.18 (7), p.2245-2251 |
issn | 0957-0233 1361-6501 |
language | eng |
recordid | cdi_proquest_miscellaneous_30005330 |
source | IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link |
title | Capacitance wire-mesh sensor for fast measurement of phase fraction distributions |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T14%3A37%3A45IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_iop_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Capacitance%20wire-mesh%20sensor%20for%20fast%20measurement%20of%20phase%20fraction%20distributions&rft.jtitle=Measurement%20science%20&%20technology&rft.au=Da%20Silva,%20M%20J&rft.date=2007-07-01&rft.volume=18&rft.issue=7&rft.spage=2245&rft.epage=2251&rft.pages=2245-2251&rft.issn=0957-0233&rft.eissn=1361-6501&rft_id=info:doi/10.1088/0957-0233/18/7/059&rft_dat=%3Cproquest_iop_p%3E30005330%3C/proquest_iop_p%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=30005330&rft_id=info:pmid/&rfr_iscdi=true |