Leak Behavior of SCC Degraded SG Tubes at a Constant Pressure

A primary water stress corrosion cracking (SCC) and an outside diameter SCC have occurred in the steam generator (SG) tubes of nuclear power plants around the world. It is important to establish the repair criteria for the degraded tubes to assure a reactor integrity, and yet maintain the plugging r...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Key engineering materials 2007-08, Vol.345-346, p.1345-1348
Hauptverfasser: Park, Jang Yul, Chan, Nam Gung, Hwang, Seong Sik, Kim, Joung Soo, Jung, Man Kyo, Kim, Hong Pyo
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1348
container_issue
container_start_page 1345
container_title Key engineering materials
container_volume 345-346
creator Park, Jang Yul
Chan, Nam Gung
Hwang, Seong Sik
Kim, Joung Soo
Jung, Man Kyo
Kim, Hong Pyo
description A primary water stress corrosion cracking (SCC) and an outside diameter SCC have occurred in the steam generator (SG) tubes of nuclear power plants around the world. It is important to establish the repair criteria for the degraded tubes to assure a reactor integrity, and yet maintain the plugging ratio within the limits needed for an efficient operation. For assessment and management of the degradation, it became crucial to understand initial leak behaviors under a small pressure and leak rate evolution under a constant pressure of SCC flaws. Stress corrosion cracked tube specimens were prepared by using a room temperature cracking technique, and leak behaviors of these tubes were measured at room temperature. Water pressure inside the tube was increased slowly in a step like manner with a designated holding time. Water leak rates just after a ligament rupture were measured by collecting the leaked water in a plastic container for a designated time. A leak rate was calculated by dividing the amount of water by the time. Under 3.45 MPa, a small water droplet was formed, but it did not grow after a 10 minute holding period at a constant pressure of 3.45 MPa. A throughwall crack seemed to open at around 8.28 MPa (1200 psi). Some tubes with 100 % through wall cracks did not show a leakage at 10.8 MPa, which is a typical pressure difference of pressurized water reactors (PWRs) during a normal operation. The higher the pressure was applied, the larger the rates of increase with the time were. Axial cracks showed a lower leak pressure than that of the circumferential cracks, which might be from a higher hoop stress than the axial stress. A large open and long axial crack showed an increasing leak rate with the time at a constant pressure.
doi_str_mv 10.4028/www.scientific.net/KEM.345-346.1345
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_29969082</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>29969082</sourcerecordid><originalsourceid>FETCH-LOGICAL-c304t-9aa5603ff2e358ecaa11ffe2a0a5eab547c49390a48f7c87558a52b109b8dc5c3</originalsourceid><addsrcrecordid>eNqVkLFOwzAURSMEEqXwD55YUFI7jhN7YIBQCqIIpJbZenGfaUqbFDuh4u9xVSRmhqd3h6sj3RNFV4wmGU3laLfbJd7U2HS1rU3SYDd6Gj8nPBMxz_KEhXAUDViep7EqlDgOmTIeK5nmp9GZ9ytKOZNMDKLrKcIHucUlfNWtI60ls7Ikd_juYIELMpuQeV-hJ9ARIGXb-A6ajrw69L53eB6dWFh7vPj9w-jtfjwvH-Lpy-SxvJnGhtOsixWAyCm3NkUuJBoAxqzFFCgIhEpkhckUVxQyaQsjCyEkiLRiVFVyYYThw-jywN269rNH3-lN7Q2u19Bg23udKpUrKtNQLA9F41rvHVq9dfUG3LdmVO_V6aBO_6nTQZ0O6nQwFi7Xe3WBMj5QOgdhMZqlXrW9a8LEf3F-AJDHgPk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>29969082</pqid></control><display><type>article</type><title>Leak Behavior of SCC Degraded SG Tubes at a Constant Pressure</title><source>Scientific.net Journals</source><creator>Park, Jang Yul ; Chan, Nam Gung ; Hwang, Seong Sik ; Kim, Joung Soo ; Jung, Man Kyo ; Kim, Hong Pyo</creator><creatorcontrib>Park, Jang Yul ; Chan, Nam Gung ; Hwang, Seong Sik ; Kim, Joung Soo ; Jung, Man Kyo ; Kim, Hong Pyo</creatorcontrib><description>A primary water stress corrosion cracking (SCC) and an outside diameter SCC have occurred in the steam generator (SG) tubes of nuclear power plants around the world. It is important to establish the repair criteria for the degraded tubes to assure a reactor integrity, and yet maintain the plugging ratio within the limits needed for an efficient operation. For assessment and management of the degradation, it became crucial to understand initial leak behaviors under a small pressure and leak rate evolution under a constant pressure of SCC flaws. Stress corrosion cracked tube specimens were prepared by using a room temperature cracking technique, and leak behaviors of these tubes were measured at room temperature. Water pressure inside the tube was increased slowly in a step like manner with a designated holding time. Water leak rates just after a ligament rupture were measured by collecting the leaked water in a plastic container for a designated time. A leak rate was calculated by dividing the amount of water by the time. Under 3.45 MPa, a small water droplet was formed, but it did not grow after a 10 minute holding period at a constant pressure of 3.45 MPa. A throughwall crack seemed to open at around 8.28 MPa (1200 psi). Some tubes with 100 % through wall cracks did not show a leakage at 10.8 MPa, which is a typical pressure difference of pressurized water reactors (PWRs) during a normal operation. The higher the pressure was applied, the larger the rates of increase with the time were. Axial cracks showed a lower leak pressure than that of the circumferential cracks, which might be from a higher hoop stress than the axial stress. A large open and long axial crack showed an increasing leak rate with the time at a constant pressure.</description><identifier>ISSN: 1013-9826</identifier><identifier>ISSN: 1662-9795</identifier><identifier>EISSN: 1662-9795</identifier><identifier>DOI: 10.4028/www.scientific.net/KEM.345-346.1345</identifier><language>eng</language><publisher>Trans Tech Publications Ltd</publisher><ispartof>Key engineering materials, 2007-08, Vol.345-346, p.1345-1348</ispartof><rights>2007 Trans Tech Publications Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c304t-9aa5603ff2e358ecaa11ffe2a0a5eab547c49390a48f7c87558a52b109b8dc5c3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.scientific.net/Image/TitleCover/70?width=600</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Park, Jang Yul</creatorcontrib><creatorcontrib>Chan, Nam Gung</creatorcontrib><creatorcontrib>Hwang, Seong Sik</creatorcontrib><creatorcontrib>Kim, Joung Soo</creatorcontrib><creatorcontrib>Jung, Man Kyo</creatorcontrib><creatorcontrib>Kim, Hong Pyo</creatorcontrib><title>Leak Behavior of SCC Degraded SG Tubes at a Constant Pressure</title><title>Key engineering materials</title><description>A primary water stress corrosion cracking (SCC) and an outside diameter SCC have occurred in the steam generator (SG) tubes of nuclear power plants around the world. It is important to establish the repair criteria for the degraded tubes to assure a reactor integrity, and yet maintain the plugging ratio within the limits needed for an efficient operation. For assessment and management of the degradation, it became crucial to understand initial leak behaviors under a small pressure and leak rate evolution under a constant pressure of SCC flaws. Stress corrosion cracked tube specimens were prepared by using a room temperature cracking technique, and leak behaviors of these tubes were measured at room temperature. Water pressure inside the tube was increased slowly in a step like manner with a designated holding time. Water leak rates just after a ligament rupture were measured by collecting the leaked water in a plastic container for a designated time. A leak rate was calculated by dividing the amount of water by the time. Under 3.45 MPa, a small water droplet was formed, but it did not grow after a 10 minute holding period at a constant pressure of 3.45 MPa. A throughwall crack seemed to open at around 8.28 MPa (1200 psi). Some tubes with 100 % through wall cracks did not show a leakage at 10.8 MPa, which is a typical pressure difference of pressurized water reactors (PWRs) during a normal operation. The higher the pressure was applied, the larger the rates of increase with the time were. Axial cracks showed a lower leak pressure than that of the circumferential cracks, which might be from a higher hoop stress than the axial stress. A large open and long axial crack showed an increasing leak rate with the time at a constant pressure.</description><issn>1013-9826</issn><issn>1662-9795</issn><issn>1662-9795</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNqVkLFOwzAURSMEEqXwD55YUFI7jhN7YIBQCqIIpJbZenGfaUqbFDuh4u9xVSRmhqd3h6sj3RNFV4wmGU3laLfbJd7U2HS1rU3SYDd6Gj8nPBMxz_KEhXAUDViep7EqlDgOmTIeK5nmp9GZ9ytKOZNMDKLrKcIHucUlfNWtI60ls7Ikd_juYIELMpuQeV-hJ9ARIGXb-A6ajrw69L53eB6dWFh7vPj9w-jtfjwvH-Lpy-SxvJnGhtOsixWAyCm3NkUuJBoAxqzFFCgIhEpkhckUVxQyaQsjCyEkiLRiVFVyYYThw-jywN269rNH3-lN7Q2u19Bg23udKpUrKtNQLA9F41rvHVq9dfUG3LdmVO_V6aBO_6nTQZ0O6nQwFi7Xe3WBMj5QOgdhMZqlXrW9a8LEf3F-AJDHgPk</recordid><startdate>20070815</startdate><enddate>20070815</enddate><creator>Park, Jang Yul</creator><creator>Chan, Nam Gung</creator><creator>Hwang, Seong Sik</creator><creator>Kim, Joung Soo</creator><creator>Jung, Man Kyo</creator><creator>Kim, Hong Pyo</creator><general>Trans Tech Publications Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SE</scope><scope>7SR</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope></search><sort><creationdate>20070815</creationdate><title>Leak Behavior of SCC Degraded SG Tubes at a Constant Pressure</title><author>Park, Jang Yul ; Chan, Nam Gung ; Hwang, Seong Sik ; Kim, Joung Soo ; Jung, Man Kyo ; Kim, Hong Pyo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c304t-9aa5603ff2e358ecaa11ffe2a0a5eab547c49390a48f7c87558a52b109b8dc5c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Park, Jang Yul</creatorcontrib><creatorcontrib>Chan, Nam Gung</creatorcontrib><creatorcontrib>Hwang, Seong Sik</creatorcontrib><creatorcontrib>Kim, Joung Soo</creatorcontrib><creatorcontrib>Jung, Man Kyo</creatorcontrib><creatorcontrib>Kim, Hong Pyo</creatorcontrib><collection>CrossRef</collection><collection>Corrosion Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><jtitle>Key engineering materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Park, Jang Yul</au><au>Chan, Nam Gung</au><au>Hwang, Seong Sik</au><au>Kim, Joung Soo</au><au>Jung, Man Kyo</au><au>Kim, Hong Pyo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Leak Behavior of SCC Degraded SG Tubes at a Constant Pressure</atitle><jtitle>Key engineering materials</jtitle><date>2007-08-15</date><risdate>2007</risdate><volume>345-346</volume><spage>1345</spage><epage>1348</epage><pages>1345-1348</pages><issn>1013-9826</issn><issn>1662-9795</issn><eissn>1662-9795</eissn><abstract>A primary water stress corrosion cracking (SCC) and an outside diameter SCC have occurred in the steam generator (SG) tubes of nuclear power plants around the world. It is important to establish the repair criteria for the degraded tubes to assure a reactor integrity, and yet maintain the plugging ratio within the limits needed for an efficient operation. For assessment and management of the degradation, it became crucial to understand initial leak behaviors under a small pressure and leak rate evolution under a constant pressure of SCC flaws. Stress corrosion cracked tube specimens were prepared by using a room temperature cracking technique, and leak behaviors of these tubes were measured at room temperature. Water pressure inside the tube was increased slowly in a step like manner with a designated holding time. Water leak rates just after a ligament rupture were measured by collecting the leaked water in a plastic container for a designated time. A leak rate was calculated by dividing the amount of water by the time. Under 3.45 MPa, a small water droplet was formed, but it did not grow after a 10 minute holding period at a constant pressure of 3.45 MPa. A throughwall crack seemed to open at around 8.28 MPa (1200 psi). Some tubes with 100 % through wall cracks did not show a leakage at 10.8 MPa, which is a typical pressure difference of pressurized water reactors (PWRs) during a normal operation. The higher the pressure was applied, the larger the rates of increase with the time were. Axial cracks showed a lower leak pressure than that of the circumferential cracks, which might be from a higher hoop stress than the axial stress. A large open and long axial crack showed an increasing leak rate with the time at a constant pressure.</abstract><pub>Trans Tech Publications Ltd</pub><doi>10.4028/www.scientific.net/KEM.345-346.1345</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1013-9826
ispartof Key engineering materials, 2007-08, Vol.345-346, p.1345-1348
issn 1013-9826
1662-9795
1662-9795
language eng
recordid cdi_proquest_miscellaneous_29969082
source Scientific.net Journals
title Leak Behavior of SCC Degraded SG Tubes at a Constant Pressure
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T16%3A23%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Leak%20Behavior%20of%20SCC%20Degraded%20SG%20Tubes%20at%20a%20Constant%20Pressure&rft.jtitle=Key%20engineering%20materials&rft.au=Park,%20Jang%20Yul&rft.date=2007-08-15&rft.volume=345-346&rft.spage=1345&rft.epage=1348&rft.pages=1345-1348&rft.issn=1013-9826&rft.eissn=1662-9795&rft_id=info:doi/10.4028/www.scientific.net/KEM.345-346.1345&rft_dat=%3Cproquest_cross%3E29969082%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=29969082&rft_id=info:pmid/&rfr_iscdi=true