A Comparison of Real-time Feedback and Tissue Response to Ultrasound-Guided High Intensity Focused Ultrasound (HIFU) Ablation using Scanned Track Exposure Regimes

Real time ultrasound monitoring of tissue ablation in clinical HIFU treatments currently depends on the observation of the appearance of new hyperechoic regions within the target volume, allowing visually directed treatment. These grey-scale changes are attributed to the formation of gas or vapour b...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Gray, Robert H R, Leslie, Thomas A, Civale, John, Kennedy, James E, Haar, Gail ter
Format: Tagungsbericht
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 327
container_issue
container_start_page 321
container_title
container_volume 911
creator Gray, Robert H R
Leslie, Thomas A
Civale, John
Kennedy, James E
Haar, Gail ter
description Real time ultrasound monitoring of tissue ablation in clinical HIFU treatments currently depends on the observation of the appearance of new hyperechoic regions within the target volume, allowing visually directed treatment. These grey-scale changes are attributed to the formation of gas or vapour bubbles. In this study, scanned track lesions have been formed in ex vivo bovine liver samples at a range of ablative intensities (free field spatial peak intensities 7 - 47 kW cm-2), and tracking speeds (1-2 mms-1). Their appearance on conventional B-mode ultrasound images has been assessed using digital imaging techniques over the first 60 seconds following HIFU exposure. The size of the lesion as seen on the ultrasound scan is compared to the macroscopic size of the lesion at dissection. It is seen that the lesion size is highly dependent on the intensity and scanning speed of the transducer. Reliable lesions can be created using scanned tracks at the lowest powers, with increased numbers of cycles, and grey-scale changes correlated strongly with the histological findings. Although not a highly sensitive indication of ablated area, ultrasound monitoring of treatment is highly specific thus confirming its clinical utility.
doi_str_mv 10.1063/1.2744292
format Conference Proceeding
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_29963411</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>29963411</sourcerecordid><originalsourceid>FETCH-LOGICAL-p186t-c6f2ff0dbad921347c6d651a1a3dc12d30e76e99427b3fd70387928d0a8a76773</originalsourceid><addsrcrecordid>eNpFjs1KAzEcxAMq2FYPvkFOooet-WqyOZbSbQsFQVvwVtJNtka3ybr_Dejr-KRuUfA0MDPMbxC6oWRMieQPdMyUEEyzMzQkik8EEVSLczQgRIuMCf5yiYYAb4QwrVQ-QN9TPIvHxrQeYsCxwk_O1Fnnjw4Xztm9Kd-xCRZvPEByfQpNDOBwF_G27loDMQWbLZK3zuKlP7ziVehcAN994SKWCXr7v4jvlqtie4-n-9p0vgcm8OGAn0sTQl_ctCfc_LOJkNoT7ND_gCt0UZka3PWfjtC2mG9my2z9uFjNpuusobnsslJWrKpIf9lqRrlQpbRyQg013JaUWU6ckk5rwdSeV1YRnivNcktMbpRUio_Q7e9u08aP5KDbHT2Urq5NcDHBjmktuaCU_wA0MG5n</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype><pqid>29963411</pqid></control><display><type>conference_proceeding</type><title>A Comparison of Real-time Feedback and Tissue Response to Ultrasound-Guided High Intensity Focused Ultrasound (HIFU) Ablation using Scanned Track Exposure Regimes</title><source>AIP Journals Complete</source><creator>Gray, Robert H R ; Leslie, Thomas A ; Civale, John ; Kennedy, James E ; Haar, Gail ter</creator><creatorcontrib>Gray, Robert H R ; Leslie, Thomas A ; Civale, John ; Kennedy, James E ; Haar, Gail ter</creatorcontrib><description>Real time ultrasound monitoring of tissue ablation in clinical HIFU treatments currently depends on the observation of the appearance of new hyperechoic regions within the target volume, allowing visually directed treatment. These grey-scale changes are attributed to the formation of gas or vapour bubbles. In this study, scanned track lesions have been formed in ex vivo bovine liver samples at a range of ablative intensities (free field spatial peak intensities 7 - 47 kW cm-2), and tracking speeds (1-2 mms-1). Their appearance on conventional B-mode ultrasound images has been assessed using digital imaging techniques over the first 60 seconds following HIFU exposure. The size of the lesion as seen on the ultrasound scan is compared to the macroscopic size of the lesion at dissection. It is seen that the lesion size is highly dependent on the intensity and scanning speed of the transducer. Reliable lesions can be created using scanned tracks at the lowest powers, with increased numbers of cycles, and grey-scale changes correlated strongly with the histological findings. Although not a highly sensitive indication of ablated area, ultrasound monitoring of treatment is highly specific thus confirming its clinical utility.</description><identifier>ISSN: 0094-243X</identifier><identifier>ISBN: 0735404194</identifier><identifier>ISBN: 9780735404199</identifier><identifier>DOI: 10.1063/1.2744292</identifier><language>eng</language><ispartof>6th International Symposium on Therapeutic Ultrasound (AIP Conference Proceedings Volume 911), 2007, Vol.911, p.321-327</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Gray, Robert H R</creatorcontrib><creatorcontrib>Leslie, Thomas A</creatorcontrib><creatorcontrib>Civale, John</creatorcontrib><creatorcontrib>Kennedy, James E</creatorcontrib><creatorcontrib>Haar, Gail ter</creatorcontrib><title>A Comparison of Real-time Feedback and Tissue Response to Ultrasound-Guided High Intensity Focused Ultrasound (HIFU) Ablation using Scanned Track Exposure Regimes</title><title>6th International Symposium on Therapeutic Ultrasound (AIP Conference Proceedings Volume 911)</title><description>Real time ultrasound monitoring of tissue ablation in clinical HIFU treatments currently depends on the observation of the appearance of new hyperechoic regions within the target volume, allowing visually directed treatment. These grey-scale changes are attributed to the formation of gas or vapour bubbles. In this study, scanned track lesions have been formed in ex vivo bovine liver samples at a range of ablative intensities (free field spatial peak intensities 7 - 47 kW cm-2), and tracking speeds (1-2 mms-1). Their appearance on conventional B-mode ultrasound images has been assessed using digital imaging techniques over the first 60 seconds following HIFU exposure. The size of the lesion as seen on the ultrasound scan is compared to the macroscopic size of the lesion at dissection. It is seen that the lesion size is highly dependent on the intensity and scanning speed of the transducer. Reliable lesions can be created using scanned tracks at the lowest powers, with increased numbers of cycles, and grey-scale changes correlated strongly with the histological findings. Although not a highly sensitive indication of ablated area, ultrasound monitoring of treatment is highly specific thus confirming its clinical utility.</description><issn>0094-243X</issn><isbn>0735404194</isbn><isbn>9780735404199</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2007</creationdate><recordtype>conference_proceeding</recordtype><recordid>eNpFjs1KAzEcxAMq2FYPvkFOooet-WqyOZbSbQsFQVvwVtJNtka3ybr_Dejr-KRuUfA0MDPMbxC6oWRMieQPdMyUEEyzMzQkik8EEVSLczQgRIuMCf5yiYYAb4QwrVQ-QN9TPIvHxrQeYsCxwk_O1Fnnjw4Xztm9Kd-xCRZvPEByfQpNDOBwF_G27loDMQWbLZK3zuKlP7ziVehcAN994SKWCXr7v4jvlqtie4-n-9p0vgcm8OGAn0sTQl_ctCfc_LOJkNoT7ND_gCt0UZka3PWfjtC2mG9my2z9uFjNpuusobnsslJWrKpIf9lqRrlQpbRyQg013JaUWU6ckk5rwdSeV1YRnivNcktMbpRUio_Q7e9u08aP5KDbHT2Urq5NcDHBjmktuaCU_wA0MG5n</recordid><startdate>20070101</startdate><enddate>20070101</enddate><creator>Gray, Robert H R</creator><creator>Leslie, Thomas A</creator><creator>Civale, John</creator><creator>Kennedy, James E</creator><creator>Haar, Gail ter</creator><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>20070101</creationdate><title>A Comparison of Real-time Feedback and Tissue Response to Ultrasound-Guided High Intensity Focused Ultrasound (HIFU) Ablation using Scanned Track Exposure Regimes</title><author>Gray, Robert H R ; Leslie, Thomas A ; Civale, John ; Kennedy, James E ; Haar, Gail ter</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p186t-c6f2ff0dbad921347c6d651a1a3dc12d30e76e99427b3fd70387928d0a8a76773</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2007</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gray, Robert H R</creatorcontrib><creatorcontrib>Leslie, Thomas A</creatorcontrib><creatorcontrib>Civale, John</creatorcontrib><creatorcontrib>Kennedy, James E</creatorcontrib><creatorcontrib>Haar, Gail ter</creatorcontrib><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gray, Robert H R</au><au>Leslie, Thomas A</au><au>Civale, John</au><au>Kennedy, James E</au><au>Haar, Gail ter</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>A Comparison of Real-time Feedback and Tissue Response to Ultrasound-Guided High Intensity Focused Ultrasound (HIFU) Ablation using Scanned Track Exposure Regimes</atitle><btitle>6th International Symposium on Therapeutic Ultrasound (AIP Conference Proceedings Volume 911)</btitle><date>2007-01-01</date><risdate>2007</risdate><volume>911</volume><spage>321</spage><epage>327</epage><pages>321-327</pages><issn>0094-243X</issn><isbn>0735404194</isbn><isbn>9780735404199</isbn><abstract>Real time ultrasound monitoring of tissue ablation in clinical HIFU treatments currently depends on the observation of the appearance of new hyperechoic regions within the target volume, allowing visually directed treatment. These grey-scale changes are attributed to the formation of gas or vapour bubbles. In this study, scanned track lesions have been formed in ex vivo bovine liver samples at a range of ablative intensities (free field spatial peak intensities 7 - 47 kW cm-2), and tracking speeds (1-2 mms-1). Their appearance on conventional B-mode ultrasound images has been assessed using digital imaging techniques over the first 60 seconds following HIFU exposure. The size of the lesion as seen on the ultrasound scan is compared to the macroscopic size of the lesion at dissection. It is seen that the lesion size is highly dependent on the intensity and scanning speed of the transducer. Reliable lesions can be created using scanned tracks at the lowest powers, with increased numbers of cycles, and grey-scale changes correlated strongly with the histological findings. Although not a highly sensitive indication of ablated area, ultrasound monitoring of treatment is highly specific thus confirming its clinical utility.</abstract><doi>10.1063/1.2744292</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0094-243X
ispartof 6th International Symposium on Therapeutic Ultrasound (AIP Conference Proceedings Volume 911), 2007, Vol.911, p.321-327
issn 0094-243X
language eng
recordid cdi_proquest_miscellaneous_29963411
source AIP Journals Complete
title A Comparison of Real-time Feedback and Tissue Response to Ultrasound-Guided High Intensity Focused Ultrasound (HIFU) Ablation using Scanned Track Exposure Regimes
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T04%3A04%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=A%20Comparison%20of%20Real-time%20Feedback%20and%20Tissue%20Response%20to%20Ultrasound-Guided%20High%20Intensity%20Focused%20Ultrasound%20(HIFU)%20Ablation%20using%20Scanned%20Track%20Exposure%20Regimes&rft.btitle=6th%20International%20Symposium%20on%20Therapeutic%20Ultrasound%20(AIP%20Conference%20Proceedings%20Volume%20911)&rft.au=Gray,%20Robert%20H%20R&rft.date=2007-01-01&rft.volume=911&rft.spage=321&rft.epage=327&rft.pages=321-327&rft.issn=0094-243X&rft.isbn=0735404194&rft.isbn_list=9780735404199&rft_id=info:doi/10.1063/1.2744292&rft_dat=%3Cproquest%3E29963411%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=29963411&rft_id=info:pmid/&rfr_iscdi=true