A Comparison of Real-time Feedback and Tissue Response to Ultrasound-Guided High Intensity Focused Ultrasound (HIFU) Ablation using Scanned Track Exposure Regimes
Real time ultrasound monitoring of tissue ablation in clinical HIFU treatments currently depends on the observation of the appearance of new hyperechoic regions within the target volume, allowing visually directed treatment. These grey-scale changes are attributed to the formation of gas or vapour b...
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 327 |
---|---|
container_issue | |
container_start_page | 321 |
container_title | |
container_volume | 911 |
creator | Gray, Robert H R Leslie, Thomas A Civale, John Kennedy, James E Haar, Gail ter |
description | Real time ultrasound monitoring of tissue ablation in clinical HIFU treatments currently depends on the observation of the appearance of new hyperechoic regions within the target volume, allowing visually directed treatment. These grey-scale changes are attributed to the formation of gas or vapour bubbles. In this study, scanned track lesions have been formed in ex vivo bovine liver samples at a range of ablative intensities (free field spatial peak intensities 7 - 47 kW cm-2), and tracking speeds (1-2 mms-1). Their appearance on conventional B-mode ultrasound images has been assessed using digital imaging techniques over the first 60 seconds following HIFU exposure. The size of the lesion as seen on the ultrasound scan is compared to the macroscopic size of the lesion at dissection. It is seen that the lesion size is highly dependent on the intensity and scanning speed of the transducer. Reliable lesions can be created using scanned tracks at the lowest powers, with increased numbers of cycles, and grey-scale changes correlated strongly with the histological findings. Although not a highly sensitive indication of ablated area, ultrasound monitoring of treatment is highly specific thus confirming its clinical utility. |
doi_str_mv | 10.1063/1.2744292 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_29963411</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>29963411</sourcerecordid><originalsourceid>FETCH-LOGICAL-p186t-c6f2ff0dbad921347c6d651a1a3dc12d30e76e99427b3fd70387928d0a8a76773</originalsourceid><addsrcrecordid>eNpFjs1KAzEcxAMq2FYPvkFOooet-WqyOZbSbQsFQVvwVtJNtka3ybr_Dejr-KRuUfA0MDPMbxC6oWRMieQPdMyUEEyzMzQkik8EEVSLczQgRIuMCf5yiYYAb4QwrVQ-QN9TPIvHxrQeYsCxwk_O1Fnnjw4Xztm9Kd-xCRZvPEByfQpNDOBwF_G27loDMQWbLZK3zuKlP7ziVehcAN994SKWCXr7v4jvlqtie4-n-9p0vgcm8OGAn0sTQl_ctCfc_LOJkNoT7ND_gCt0UZka3PWfjtC2mG9my2z9uFjNpuusobnsslJWrKpIf9lqRrlQpbRyQg013JaUWU6ckk5rwdSeV1YRnivNcktMbpRUio_Q7e9u08aP5KDbHT2Urq5NcDHBjmktuaCU_wA0MG5n</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype><pqid>29963411</pqid></control><display><type>conference_proceeding</type><title>A Comparison of Real-time Feedback and Tissue Response to Ultrasound-Guided High Intensity Focused Ultrasound (HIFU) Ablation using Scanned Track Exposure Regimes</title><source>AIP Journals Complete</source><creator>Gray, Robert H R ; Leslie, Thomas A ; Civale, John ; Kennedy, James E ; Haar, Gail ter</creator><creatorcontrib>Gray, Robert H R ; Leslie, Thomas A ; Civale, John ; Kennedy, James E ; Haar, Gail ter</creatorcontrib><description>Real time ultrasound monitoring of tissue ablation in clinical HIFU treatments currently depends on the observation of the appearance of new hyperechoic regions within the target volume, allowing visually directed treatment. These grey-scale changes are attributed to the formation of gas or vapour bubbles. In this study, scanned track lesions have been formed in ex vivo bovine liver samples at a range of ablative intensities (free field spatial peak intensities 7 - 47 kW cm-2), and tracking speeds (1-2 mms-1). Their appearance on conventional B-mode ultrasound images has been assessed using digital imaging techniques over the first 60 seconds following HIFU exposure. The size of the lesion as seen on the ultrasound scan is compared to the macroscopic size of the lesion at dissection. It is seen that the lesion size is highly dependent on the intensity and scanning speed of the transducer. Reliable lesions can be created using scanned tracks at the lowest powers, with increased numbers of cycles, and grey-scale changes correlated strongly with the histological findings. Although not a highly sensitive indication of ablated area, ultrasound monitoring of treatment is highly specific thus confirming its clinical utility.</description><identifier>ISSN: 0094-243X</identifier><identifier>ISBN: 0735404194</identifier><identifier>ISBN: 9780735404199</identifier><identifier>DOI: 10.1063/1.2744292</identifier><language>eng</language><ispartof>6th International Symposium on Therapeutic Ultrasound (AIP Conference Proceedings Volume 911), 2007, Vol.911, p.321-327</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Gray, Robert H R</creatorcontrib><creatorcontrib>Leslie, Thomas A</creatorcontrib><creatorcontrib>Civale, John</creatorcontrib><creatorcontrib>Kennedy, James E</creatorcontrib><creatorcontrib>Haar, Gail ter</creatorcontrib><title>A Comparison of Real-time Feedback and Tissue Response to Ultrasound-Guided High Intensity Focused Ultrasound (HIFU) Ablation using Scanned Track Exposure Regimes</title><title>6th International Symposium on Therapeutic Ultrasound (AIP Conference Proceedings Volume 911)</title><description>Real time ultrasound monitoring of tissue ablation in clinical HIFU treatments currently depends on the observation of the appearance of new hyperechoic regions within the target volume, allowing visually directed treatment. These grey-scale changes are attributed to the formation of gas or vapour bubbles. In this study, scanned track lesions have been formed in ex vivo bovine liver samples at a range of ablative intensities (free field spatial peak intensities 7 - 47 kW cm-2), and tracking speeds (1-2 mms-1). Their appearance on conventional B-mode ultrasound images has been assessed using digital imaging techniques over the first 60 seconds following HIFU exposure. The size of the lesion as seen on the ultrasound scan is compared to the macroscopic size of the lesion at dissection. It is seen that the lesion size is highly dependent on the intensity and scanning speed of the transducer. Reliable lesions can be created using scanned tracks at the lowest powers, with increased numbers of cycles, and grey-scale changes correlated strongly with the histological findings. Although not a highly sensitive indication of ablated area, ultrasound monitoring of treatment is highly specific thus confirming its clinical utility.</description><issn>0094-243X</issn><isbn>0735404194</isbn><isbn>9780735404199</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2007</creationdate><recordtype>conference_proceeding</recordtype><recordid>eNpFjs1KAzEcxAMq2FYPvkFOooet-WqyOZbSbQsFQVvwVtJNtka3ybr_Dejr-KRuUfA0MDPMbxC6oWRMieQPdMyUEEyzMzQkik8EEVSLczQgRIuMCf5yiYYAb4QwrVQ-QN9TPIvHxrQeYsCxwk_O1Fnnjw4Xztm9Kd-xCRZvPEByfQpNDOBwF_G27loDMQWbLZK3zuKlP7ziVehcAN994SKWCXr7v4jvlqtie4-n-9p0vgcm8OGAn0sTQl_ctCfc_LOJkNoT7ND_gCt0UZka3PWfjtC2mG9my2z9uFjNpuusobnsslJWrKpIf9lqRrlQpbRyQg013JaUWU6ckk5rwdSeV1YRnivNcktMbpRUio_Q7e9u08aP5KDbHT2Urq5NcDHBjmktuaCU_wA0MG5n</recordid><startdate>20070101</startdate><enddate>20070101</enddate><creator>Gray, Robert H R</creator><creator>Leslie, Thomas A</creator><creator>Civale, John</creator><creator>Kennedy, James E</creator><creator>Haar, Gail ter</creator><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>20070101</creationdate><title>A Comparison of Real-time Feedback and Tissue Response to Ultrasound-Guided High Intensity Focused Ultrasound (HIFU) Ablation using Scanned Track Exposure Regimes</title><author>Gray, Robert H R ; Leslie, Thomas A ; Civale, John ; Kennedy, James E ; Haar, Gail ter</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p186t-c6f2ff0dbad921347c6d651a1a3dc12d30e76e99427b3fd70387928d0a8a76773</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2007</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gray, Robert H R</creatorcontrib><creatorcontrib>Leslie, Thomas A</creatorcontrib><creatorcontrib>Civale, John</creatorcontrib><creatorcontrib>Kennedy, James E</creatorcontrib><creatorcontrib>Haar, Gail ter</creatorcontrib><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gray, Robert H R</au><au>Leslie, Thomas A</au><au>Civale, John</au><au>Kennedy, James E</au><au>Haar, Gail ter</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>A Comparison of Real-time Feedback and Tissue Response to Ultrasound-Guided High Intensity Focused Ultrasound (HIFU) Ablation using Scanned Track Exposure Regimes</atitle><btitle>6th International Symposium on Therapeutic Ultrasound (AIP Conference Proceedings Volume 911)</btitle><date>2007-01-01</date><risdate>2007</risdate><volume>911</volume><spage>321</spage><epage>327</epage><pages>321-327</pages><issn>0094-243X</issn><isbn>0735404194</isbn><isbn>9780735404199</isbn><abstract>Real time ultrasound monitoring of tissue ablation in clinical HIFU treatments currently depends on the observation of the appearance of new hyperechoic regions within the target volume, allowing visually directed treatment. These grey-scale changes are attributed to the formation of gas or vapour bubbles. In this study, scanned track lesions have been formed in ex vivo bovine liver samples at a range of ablative intensities (free field spatial peak intensities 7 - 47 kW cm-2), and tracking speeds (1-2 mms-1). Their appearance on conventional B-mode ultrasound images has been assessed using digital imaging techniques over the first 60 seconds following HIFU exposure. The size of the lesion as seen on the ultrasound scan is compared to the macroscopic size of the lesion at dissection. It is seen that the lesion size is highly dependent on the intensity and scanning speed of the transducer. Reliable lesions can be created using scanned tracks at the lowest powers, with increased numbers of cycles, and grey-scale changes correlated strongly with the histological findings. Although not a highly sensitive indication of ablated area, ultrasound monitoring of treatment is highly specific thus confirming its clinical utility.</abstract><doi>10.1063/1.2744292</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0094-243X |
ispartof | 6th International Symposium on Therapeutic Ultrasound (AIP Conference Proceedings Volume 911), 2007, Vol.911, p.321-327 |
issn | 0094-243X |
language | eng |
recordid | cdi_proquest_miscellaneous_29963411 |
source | AIP Journals Complete |
title | A Comparison of Real-time Feedback and Tissue Response to Ultrasound-Guided High Intensity Focused Ultrasound (HIFU) Ablation using Scanned Track Exposure Regimes |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T04%3A04%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=A%20Comparison%20of%20Real-time%20Feedback%20and%20Tissue%20Response%20to%20Ultrasound-Guided%20High%20Intensity%20Focused%20Ultrasound%20(HIFU)%20Ablation%20using%20Scanned%20Track%20Exposure%20Regimes&rft.btitle=6th%20International%20Symposium%20on%20Therapeutic%20Ultrasound%20(AIP%20Conference%20Proceedings%20Volume%20911)&rft.au=Gray,%20Robert%20H%20R&rft.date=2007-01-01&rft.volume=911&rft.spage=321&rft.epage=327&rft.pages=321-327&rft.issn=0094-243X&rft.isbn=0735404194&rft.isbn_list=9780735404199&rft_id=info:doi/10.1063/1.2744292&rft_dat=%3Cproquest%3E29963411%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=29963411&rft_id=info:pmid/&rfr_iscdi=true |