Treatment of wastewaters from manufactured gas plants

Concentrated wastewaters from a gasworks were treated by the addition of formaldehyde which condensed the phenol at an optimal temperature of 60C. The complex was settled after adjustment of the pH to 10.5 with a lime solution. The pH was then raised to 10.5-11.2 and ammonia removed by air stripping...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Land contamination & reclamation 1995-01, Vol.3 (4), p.2-3-2-5
Hauptverfasser: Cocheci, V, Bogatu, C, Radovan, C
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3-2-5
container_issue 4
container_start_page 2
container_title Land contamination & reclamation
container_volume 3
creator Cocheci, V
Bogatu, C
Radovan, C
description Concentrated wastewaters from a gasworks were treated by the addition of formaldehyde which condensed the phenol at an optimal temperature of 60C. The complex was settled after adjustment of the pH to 10.5 with a lime solution. The pH was then raised to 10.5-11.2 and ammonia removed by air stripping. The effluent from this process was then diluted 5 times and treated with activated sludge. Electrocoagulation and electrochemical oxidation or chemical oxidation with sodium hypochlorite, followed. The whole process reduced the COD from 84,000 to 112-150 mg per litre.
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_29932772</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>29932772</sourcerecordid><originalsourceid>FETCH-LOGICAL-p932-3216065f41367b687b4966481519b719963c7f570730cbb00609534346b2471d3</originalsourceid><addsrcrecordid>eNqNjrtOAzEQRV2AREj4B1d0K3n8mIlLFPGSItFsH9kbG4H2hcer_D4rQQ_VbY7OPVdiozxSoxyYG3HL_KkUgiHYCNeWFOqQxiqnLC-Ba7qEmgrLXKZBDmFccujqUtJZvgeWcx_GyjtxnUPP6e53t6J9emwPL83x7fn18HBsZm90YzSgQpctGKSIe4rWI9o9OPCRwHs0HWVHiozqYlyblHfGGotRW4Kz2Yr7H-1cpq8lcT0NH9ylfm1I08In7dcbIv0PkLTVCv4E11KLbjV-A429Wjg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>13646572</pqid></control><display><type>article</type><title>Treatment of wastewaters from manufactured gas plants</title><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><creator>Cocheci, V ; Bogatu, C ; Radovan, C</creator><creatorcontrib>Cocheci, V ; Bogatu, C ; Radovan, C</creatorcontrib><description>Concentrated wastewaters from a gasworks were treated by the addition of formaldehyde which condensed the phenol at an optimal temperature of 60C. The complex was settled after adjustment of the pH to 10.5 with a lime solution. The pH was then raised to 10.5-11.2 and ammonia removed by air stripping. The effluent from this process was then diluted 5 times and treated with activated sludge. Electrocoagulation and electrochemical oxidation or chemical oxidation with sodium hypochlorite, followed. The whole process reduced the COD from 84,000 to 112-150 mg per litre.</description><identifier>ISSN: 0967-0513</identifier><language>eng</language><ispartof>Land contamination &amp; reclamation, 1995-01, Vol.3 (4), p.2-3-2-5</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids></links><search><creatorcontrib>Cocheci, V</creatorcontrib><creatorcontrib>Bogatu, C</creatorcontrib><creatorcontrib>Radovan, C</creatorcontrib><title>Treatment of wastewaters from manufactured gas plants</title><title>Land contamination &amp; reclamation</title><description>Concentrated wastewaters from a gasworks were treated by the addition of formaldehyde which condensed the phenol at an optimal temperature of 60C. The complex was settled after adjustment of the pH to 10.5 with a lime solution. The pH was then raised to 10.5-11.2 and ammonia removed by air stripping. The effluent from this process was then diluted 5 times and treated with activated sludge. Electrocoagulation and electrochemical oxidation or chemical oxidation with sodium hypochlorite, followed. The whole process reduced the COD from 84,000 to 112-150 mg per litre.</description><issn>0967-0513</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1995</creationdate><recordtype>article</recordtype><recordid>eNqNjrtOAzEQRV2AREj4B1d0K3n8mIlLFPGSItFsH9kbG4H2hcer_D4rQQ_VbY7OPVdiozxSoxyYG3HL_KkUgiHYCNeWFOqQxiqnLC-Ba7qEmgrLXKZBDmFccujqUtJZvgeWcx_GyjtxnUPP6e53t6J9emwPL83x7fn18HBsZm90YzSgQpctGKSIe4rWI9o9OPCRwHs0HWVHiozqYlyblHfGGotRW4Kz2Yr7H-1cpq8lcT0NH9ylfm1I08In7dcbIv0PkLTVCv4E11KLbjV-A429Wjg</recordid><startdate>19950101</startdate><enddate>19950101</enddate><creator>Cocheci, V</creator><creator>Bogatu, C</creator><creator>Radovan, C</creator><scope>7QH</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>19950101</creationdate><title>Treatment of wastewaters from manufactured gas plants</title><author>Cocheci, V ; Bogatu, C ; Radovan, C</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p932-3216065f41367b687b4966481519b719963c7f570730cbb00609534346b2471d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1995</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cocheci, V</creatorcontrib><creatorcontrib>Bogatu, C</creatorcontrib><creatorcontrib>Radovan, C</creatorcontrib><collection>Aqualine</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Land contamination &amp; reclamation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cocheci, V</au><au>Bogatu, C</au><au>Radovan, C</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Treatment of wastewaters from manufactured gas plants</atitle><jtitle>Land contamination &amp; reclamation</jtitle><date>1995-01-01</date><risdate>1995</risdate><volume>3</volume><issue>4</issue><spage>2</spage><epage>3-2-5</epage><pages>2-3-2-5</pages><issn>0967-0513</issn><abstract>Concentrated wastewaters from a gasworks were treated by the addition of formaldehyde which condensed the phenol at an optimal temperature of 60C. The complex was settled after adjustment of the pH to 10.5 with a lime solution. The pH was then raised to 10.5-11.2 and ammonia removed by air stripping. The effluent from this process was then diluted 5 times and treated with activated sludge. Electrocoagulation and electrochemical oxidation or chemical oxidation with sodium hypochlorite, followed. The whole process reduced the COD from 84,000 to 112-150 mg per litre.</abstract></addata></record>
fulltext fulltext
identifier ISSN: 0967-0513
ispartof Land contamination & reclamation, 1995-01, Vol.3 (4), p.2-3-2-5
issn 0967-0513
language eng
recordid cdi_proquest_miscellaneous_29932772
source EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection
title Treatment of wastewaters from manufactured gas plants
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T05%3A46%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Treatment%20of%20wastewaters%20from%20manufactured%20gas%20plants&rft.jtitle=Land%20contamination%20&%20reclamation&rft.au=Cocheci,%20V&rft.date=1995-01-01&rft.volume=3&rft.issue=4&rft.spage=2&rft.epage=3-2-5&rft.pages=2-3-2-5&rft.issn=0967-0513&rft_id=info:doi/&rft_dat=%3Cproquest%3E29932772%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=13646572&rft_id=info:pmid/&rfr_iscdi=true