Operating temperature and distribution of a working fluid in LHP

One of the main factors that influence the operating temperature of a loop heat pipe (LHP) is the distribution of a working fluid in the device. The paper presents the classification of LHP operating modes on the basis of the criterion of presence or absence of the working-fluid vapor phase in the c...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of heat and mass transfer 2007-07, Vol.50 (13), p.2704-2713
Hauptverfasser: Chernysheva, M.A., Vershinin, S.V., Maydanik, Yu. F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:One of the main factors that influence the operating temperature of a loop heat pipe (LHP) is the distribution of a working fluid in the device. The paper presents the classification of LHP operating modes on the basis of the criterion of presence or absence of the working-fluid vapor phase in the compensation chamber (CC). It gives a description of method of calculating the LHP operating temperature for every operating mode and shows the characteristic features, advantages and disadvantages of every mode.
ISSN:0017-9310
1879-2189
DOI:10.1016/j.ijheatmasstransfer.2006.11.020