On the relationship between time and frequency domain methods in time delay estimation for leak detection in water distribution pipes

Estimation of time delay in a vibroacoustic system is a problem that occurs in several engineering fields. This can be determined directly in the time domain or in the frequency domain by examining the phase spectrum of two signals. In this paper, the equivalence of these two methods is discussed wi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of sound and vibration 2007-07, Vol.304 (1), p.213-223
Hauptverfasser: Brennan, M.J., Gao, Y., Joseph, P.F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 223
container_issue 1
container_start_page 213
container_title Journal of sound and vibration
container_volume 304
creator Brennan, M.J.
Gao, Y.
Joseph, P.F.
description Estimation of time delay in a vibroacoustic system is a problem that occurs in several engineering fields. This can be determined directly in the time domain or in the frequency domain by examining the phase spectrum of two signals. In this paper, the equivalence of these two methods is discussed with particular reference to the problem of determining the position of a leak in water distribution pipes. Popular methods central to this process are based on cross-correlation, and it has been found that pre-whitening the signals prior to determining the cross-correlation function has certain advantages. A new interpretation of the process of cross-correlation for time delay estimation is presented. To support the theoretical findings, analysis is carried out on test data from a specially constructed leak-detection facility located at a National Research Council site in Canada. Test results show that the time delay estimates and their variances calculated using time and frequency domain methods are almost identical.
doi_str_mv 10.1016/j.jsv.2007.02.023
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_29897744</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0022460X07001423</els_id><sourcerecordid>29897744</sourcerecordid><originalsourceid>FETCH-LOGICAL-c358t-5cad99fb8e90175e2148a705d21b682e4e85827e82215d24e2561e62fb49e3133</originalsourceid><addsrcrecordid>eNp9kM9qGzEQxkVJoI7TB-hNl-S2rqSVdrX0VEzSFgy-NNCb0EqzWO56d6ORHfwAee_Kf6C3woDQN7_5hvkI-czZgjNefdkutnhYCMbqBRO5yg9kxlmjCq0qfUNmjAlRyIr9_kjuELeMsUaWckbe1wNNG6ARepvCOOAmTLSF9AaQG2EH1A6edhFe9zC4I_XjzoaB7iBtRo80XCGfx48UMH_ONrQbI-3B_smdBO4sZfbNJojUB0wxtPuzOoUJ8J7cdrZH-HR95-Tl-enX8kexWn__ufy2KlypdCqUs75pulZDw3itQHCpbc2UF7yttAAJWmlRgxaCZ1GCUBWHSnStbKDkZTknjxffKY75IExmF9BB39sBxj0a0eimrqXMIL-ALo6IETozxXxaPBrOzClwszU5cHMK3DCR62T-cDW36GzfRTu4gP8Gda2U5iJzXy8c5EsPAaJBF3K44EPMURk_hv9s-QsT4pgf</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>29897744</pqid></control><display><type>article</type><title>On the relationship between time and frequency domain methods in time delay estimation for leak detection in water distribution pipes</title><source>Elsevier ScienceDirect Journals Complete - AutoHoldings</source><creator>Brennan, M.J. ; Gao, Y. ; Joseph, P.F.</creator><creatorcontrib>Brennan, M.J. ; Gao, Y. ; Joseph, P.F.</creatorcontrib><description>Estimation of time delay in a vibroacoustic system is a problem that occurs in several engineering fields. This can be determined directly in the time domain or in the frequency domain by examining the phase spectrum of two signals. In this paper, the equivalence of these two methods is discussed with particular reference to the problem of determining the position of a leak in water distribution pipes. Popular methods central to this process are based on cross-correlation, and it has been found that pre-whitening the signals prior to determining the cross-correlation function has certain advantages. A new interpretation of the process of cross-correlation for time delay estimation is presented. To support the theoretical findings, analysis is carried out on test data from a specially constructed leak-detection facility located at a National Research Council site in Canada. Test results show that the time delay estimates and their variances calculated using time and frequency domain methods are almost identical.</description><identifier>ISSN: 0022-460X</identifier><identifier>EISSN: 1095-8568</identifier><identifier>DOI: 10.1016/j.jsv.2007.02.023</identifier><identifier>CODEN: JSVIAG</identifier><language>eng</language><publisher>London: Elsevier Ltd</publisher><subject>Acoustics ; Exact sciences and technology ; Fundamental areas of phenomenology (including applications) ; Physics ; Structural acoustics and vibration</subject><ispartof>Journal of sound and vibration, 2007-07, Vol.304 (1), p.213-223</ispartof><rights>2007 Elsevier Ltd</rights><rights>2007 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c358t-5cad99fb8e90175e2148a705d21b682e4e85827e82215d24e2561e62fb49e3133</citedby><cites>FETCH-LOGICAL-c358t-5cad99fb8e90175e2148a705d21b682e4e85827e82215d24e2561e62fb49e3133</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.jsv.2007.02.023$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3548,27923,27924,45994</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=18755812$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Brennan, M.J.</creatorcontrib><creatorcontrib>Gao, Y.</creatorcontrib><creatorcontrib>Joseph, P.F.</creatorcontrib><title>On the relationship between time and frequency domain methods in time delay estimation for leak detection in water distribution pipes</title><title>Journal of sound and vibration</title><description>Estimation of time delay in a vibroacoustic system is a problem that occurs in several engineering fields. This can be determined directly in the time domain or in the frequency domain by examining the phase spectrum of two signals. In this paper, the equivalence of these two methods is discussed with particular reference to the problem of determining the position of a leak in water distribution pipes. Popular methods central to this process are based on cross-correlation, and it has been found that pre-whitening the signals prior to determining the cross-correlation function has certain advantages. A new interpretation of the process of cross-correlation for time delay estimation is presented. To support the theoretical findings, analysis is carried out on test data from a specially constructed leak-detection facility located at a National Research Council site in Canada. Test results show that the time delay estimates and their variances calculated using time and frequency domain methods are almost identical.</description><subject>Acoustics</subject><subject>Exact sciences and technology</subject><subject>Fundamental areas of phenomenology (including applications)</subject><subject>Physics</subject><subject>Structural acoustics and vibration</subject><issn>0022-460X</issn><issn>1095-8568</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNp9kM9qGzEQxkVJoI7TB-hNl-S2rqSVdrX0VEzSFgy-NNCb0EqzWO56d6ORHfwAee_Kf6C3woDQN7_5hvkI-czZgjNefdkutnhYCMbqBRO5yg9kxlmjCq0qfUNmjAlRyIr9_kjuELeMsUaWckbe1wNNG6ARepvCOOAmTLSF9AaQG2EH1A6edhFe9zC4I_XjzoaB7iBtRo80XCGfx48UMH_ONrQbI-3B_smdBO4sZfbNJojUB0wxtPuzOoUJ8J7cdrZH-HR95-Tl-enX8kexWn__ufy2KlypdCqUs75pulZDw3itQHCpbc2UF7yttAAJWmlRgxaCZ1GCUBWHSnStbKDkZTknjxffKY75IExmF9BB39sBxj0a0eimrqXMIL-ALo6IETozxXxaPBrOzClwszU5cHMK3DCR62T-cDW36GzfRTu4gP8Gda2U5iJzXy8c5EsPAaJBF3K44EPMURk_hv9s-QsT4pgf</recordid><startdate>20070710</startdate><enddate>20070710</enddate><creator>Brennan, M.J.</creator><creator>Gao, Y.</creator><creator>Joseph, P.F.</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>20070710</creationdate><title>On the relationship between time and frequency domain methods in time delay estimation for leak detection in water distribution pipes</title><author>Brennan, M.J. ; Gao, Y. ; Joseph, P.F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c358t-5cad99fb8e90175e2148a705d21b682e4e85827e82215d24e2561e62fb49e3133</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Acoustics</topic><topic>Exact sciences and technology</topic><topic>Fundamental areas of phenomenology (including applications)</topic><topic>Physics</topic><topic>Structural acoustics and vibration</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Brennan, M.J.</creatorcontrib><creatorcontrib>Gao, Y.</creatorcontrib><creatorcontrib>Joseph, P.F.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Journal of sound and vibration</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Brennan, M.J.</au><au>Gao, Y.</au><au>Joseph, P.F.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>On the relationship between time and frequency domain methods in time delay estimation for leak detection in water distribution pipes</atitle><jtitle>Journal of sound and vibration</jtitle><date>2007-07-10</date><risdate>2007</risdate><volume>304</volume><issue>1</issue><spage>213</spage><epage>223</epage><pages>213-223</pages><issn>0022-460X</issn><eissn>1095-8568</eissn><coden>JSVIAG</coden><abstract>Estimation of time delay in a vibroacoustic system is a problem that occurs in several engineering fields. This can be determined directly in the time domain or in the frequency domain by examining the phase spectrum of two signals. In this paper, the equivalence of these two methods is discussed with particular reference to the problem of determining the position of a leak in water distribution pipes. Popular methods central to this process are based on cross-correlation, and it has been found that pre-whitening the signals prior to determining the cross-correlation function has certain advantages. A new interpretation of the process of cross-correlation for time delay estimation is presented. To support the theoretical findings, analysis is carried out on test data from a specially constructed leak-detection facility located at a National Research Council site in Canada. Test results show that the time delay estimates and their variances calculated using time and frequency domain methods are almost identical.</abstract><cop>London</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.jsv.2007.02.023</doi><tpages>11</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0022-460X
ispartof Journal of sound and vibration, 2007-07, Vol.304 (1), p.213-223
issn 0022-460X
1095-8568
language eng
recordid cdi_proquest_miscellaneous_29897744
source Elsevier ScienceDirect Journals Complete - AutoHoldings
subjects Acoustics
Exact sciences and technology
Fundamental areas of phenomenology (including applications)
Physics
Structural acoustics and vibration
title On the relationship between time and frequency domain methods in time delay estimation for leak detection in water distribution pipes
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T00%3A58%3A45IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=On%20the%20relationship%20between%20time%20and%20frequency%20domain%20methods%20in%20time%20delay%20estimation%20for%20leak%20detection%20in%20water%20distribution%20pipes&rft.jtitle=Journal%20of%20sound%20and%20vibration&rft.au=Brennan,%20M.J.&rft.date=2007-07-10&rft.volume=304&rft.issue=1&rft.spage=213&rft.epage=223&rft.pages=213-223&rft.issn=0022-460X&rft.eissn=1095-8568&rft.coden=JSVIAG&rft_id=info:doi/10.1016/j.jsv.2007.02.023&rft_dat=%3Cproquest_cross%3E29897744%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=29897744&rft_id=info:pmid/&rft_els_id=S0022460X07001423&rfr_iscdi=true