On the relationship between time and frequency domain methods in time delay estimation for leak detection in water distribution pipes
Estimation of time delay in a vibroacoustic system is a problem that occurs in several engineering fields. This can be determined directly in the time domain or in the frequency domain by examining the phase spectrum of two signals. In this paper, the equivalence of these two methods is discussed wi...
Gespeichert in:
Veröffentlicht in: | Journal of sound and vibration 2007-07, Vol.304 (1), p.213-223 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 223 |
---|---|
container_issue | 1 |
container_start_page | 213 |
container_title | Journal of sound and vibration |
container_volume | 304 |
creator | Brennan, M.J. Gao, Y. Joseph, P.F. |
description | Estimation of time delay in a vibroacoustic system is a problem that occurs in several engineering fields. This can be determined directly in the time domain or in the frequency domain by examining the phase spectrum of two signals. In this paper, the equivalence of these two methods is discussed with particular reference to the problem of determining the position of a leak in water distribution pipes. Popular methods central to this process are based on cross-correlation, and it has been found that pre-whitening the signals prior to determining the cross-correlation function has certain advantages. A new interpretation of the process of cross-correlation for time delay estimation is presented. To support the theoretical findings, analysis is carried out on test data from a specially constructed leak-detection facility located at a National Research Council site in Canada. Test results show that the time delay estimates and their variances calculated using time and frequency domain methods are almost identical. |
doi_str_mv | 10.1016/j.jsv.2007.02.023 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_29897744</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0022460X07001423</els_id><sourcerecordid>29897744</sourcerecordid><originalsourceid>FETCH-LOGICAL-c358t-5cad99fb8e90175e2148a705d21b682e4e85827e82215d24e2561e62fb49e3133</originalsourceid><addsrcrecordid>eNp9kM9qGzEQxkVJoI7TB-hNl-S2rqSVdrX0VEzSFgy-NNCb0EqzWO56d6ORHfwAee_Kf6C3woDQN7_5hvkI-czZgjNefdkutnhYCMbqBRO5yg9kxlmjCq0qfUNmjAlRyIr9_kjuELeMsUaWckbe1wNNG6ARepvCOOAmTLSF9AaQG2EH1A6edhFe9zC4I_XjzoaB7iBtRo80XCGfx48UMH_ONrQbI-3B_smdBO4sZfbNJojUB0wxtPuzOoUJ8J7cdrZH-HR95-Tl-enX8kexWn__ufy2KlypdCqUs75pulZDw3itQHCpbc2UF7yttAAJWmlRgxaCZ1GCUBWHSnStbKDkZTknjxffKY75IExmF9BB39sBxj0a0eimrqXMIL-ALo6IETozxXxaPBrOzClwszU5cHMK3DCR62T-cDW36GzfRTu4gP8Gda2U5iJzXy8c5EsPAaJBF3K44EPMURk_hv9s-QsT4pgf</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>29897744</pqid></control><display><type>article</type><title>On the relationship between time and frequency domain methods in time delay estimation for leak detection in water distribution pipes</title><source>Elsevier ScienceDirect Journals Complete - AutoHoldings</source><creator>Brennan, M.J. ; Gao, Y. ; Joseph, P.F.</creator><creatorcontrib>Brennan, M.J. ; Gao, Y. ; Joseph, P.F.</creatorcontrib><description>Estimation of time delay in a vibroacoustic system is a problem that occurs in several engineering fields. This can be determined directly in the time domain or in the frequency domain by examining the phase spectrum of two signals. In this paper, the equivalence of these two methods is discussed with particular reference to the problem of determining the position of a leak in water distribution pipes. Popular methods central to this process are based on cross-correlation, and it has been found that pre-whitening the signals prior to determining the cross-correlation function has certain advantages. A new interpretation of the process of cross-correlation for time delay estimation is presented. To support the theoretical findings, analysis is carried out on test data from a specially constructed leak-detection facility located at a National Research Council site in Canada. Test results show that the time delay estimates and their variances calculated using time and frequency domain methods are almost identical.</description><identifier>ISSN: 0022-460X</identifier><identifier>EISSN: 1095-8568</identifier><identifier>DOI: 10.1016/j.jsv.2007.02.023</identifier><identifier>CODEN: JSVIAG</identifier><language>eng</language><publisher>London: Elsevier Ltd</publisher><subject>Acoustics ; Exact sciences and technology ; Fundamental areas of phenomenology (including applications) ; Physics ; Structural acoustics and vibration</subject><ispartof>Journal of sound and vibration, 2007-07, Vol.304 (1), p.213-223</ispartof><rights>2007 Elsevier Ltd</rights><rights>2007 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c358t-5cad99fb8e90175e2148a705d21b682e4e85827e82215d24e2561e62fb49e3133</citedby><cites>FETCH-LOGICAL-c358t-5cad99fb8e90175e2148a705d21b682e4e85827e82215d24e2561e62fb49e3133</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.jsv.2007.02.023$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3548,27923,27924,45994</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=18755812$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Brennan, M.J.</creatorcontrib><creatorcontrib>Gao, Y.</creatorcontrib><creatorcontrib>Joseph, P.F.</creatorcontrib><title>On the relationship between time and frequency domain methods in time delay estimation for leak detection in water distribution pipes</title><title>Journal of sound and vibration</title><description>Estimation of time delay in a vibroacoustic system is a problem that occurs in several engineering fields. This can be determined directly in the time domain or in the frequency domain by examining the phase spectrum of two signals. In this paper, the equivalence of these two methods is discussed with particular reference to the problem of determining the position of a leak in water distribution pipes. Popular methods central to this process are based on cross-correlation, and it has been found that pre-whitening the signals prior to determining the cross-correlation function has certain advantages. A new interpretation of the process of cross-correlation for time delay estimation is presented. To support the theoretical findings, analysis is carried out on test data from a specially constructed leak-detection facility located at a National Research Council site in Canada. Test results show that the time delay estimates and their variances calculated using time and frequency domain methods are almost identical.</description><subject>Acoustics</subject><subject>Exact sciences and technology</subject><subject>Fundamental areas of phenomenology (including applications)</subject><subject>Physics</subject><subject>Structural acoustics and vibration</subject><issn>0022-460X</issn><issn>1095-8568</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNp9kM9qGzEQxkVJoI7TB-hNl-S2rqSVdrX0VEzSFgy-NNCb0EqzWO56d6ORHfwAee_Kf6C3woDQN7_5hvkI-czZgjNefdkutnhYCMbqBRO5yg9kxlmjCq0qfUNmjAlRyIr9_kjuELeMsUaWckbe1wNNG6ARepvCOOAmTLSF9AaQG2EH1A6edhFe9zC4I_XjzoaB7iBtRo80XCGfx48UMH_ONrQbI-3B_smdBO4sZfbNJojUB0wxtPuzOoUJ8J7cdrZH-HR95-Tl-enX8kexWn__ufy2KlypdCqUs75pulZDw3itQHCpbc2UF7yttAAJWmlRgxaCZ1GCUBWHSnStbKDkZTknjxffKY75IExmF9BB39sBxj0a0eimrqXMIL-ALo6IETozxXxaPBrOzClwszU5cHMK3DCR62T-cDW36GzfRTu4gP8Gda2U5iJzXy8c5EsPAaJBF3K44EPMURk_hv9s-QsT4pgf</recordid><startdate>20070710</startdate><enddate>20070710</enddate><creator>Brennan, M.J.</creator><creator>Gao, Y.</creator><creator>Joseph, P.F.</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>20070710</creationdate><title>On the relationship between time and frequency domain methods in time delay estimation for leak detection in water distribution pipes</title><author>Brennan, M.J. ; Gao, Y. ; Joseph, P.F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c358t-5cad99fb8e90175e2148a705d21b682e4e85827e82215d24e2561e62fb49e3133</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Acoustics</topic><topic>Exact sciences and technology</topic><topic>Fundamental areas of phenomenology (including applications)</topic><topic>Physics</topic><topic>Structural acoustics and vibration</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Brennan, M.J.</creatorcontrib><creatorcontrib>Gao, Y.</creatorcontrib><creatorcontrib>Joseph, P.F.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Journal of sound and vibration</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Brennan, M.J.</au><au>Gao, Y.</au><au>Joseph, P.F.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>On the relationship between time and frequency domain methods in time delay estimation for leak detection in water distribution pipes</atitle><jtitle>Journal of sound and vibration</jtitle><date>2007-07-10</date><risdate>2007</risdate><volume>304</volume><issue>1</issue><spage>213</spage><epage>223</epage><pages>213-223</pages><issn>0022-460X</issn><eissn>1095-8568</eissn><coden>JSVIAG</coden><abstract>Estimation of time delay in a vibroacoustic system is a problem that occurs in several engineering fields. This can be determined directly in the time domain or in the frequency domain by examining the phase spectrum of two signals. In this paper, the equivalence of these two methods is discussed with particular reference to the problem of determining the position of a leak in water distribution pipes. Popular methods central to this process are based on cross-correlation, and it has been found that pre-whitening the signals prior to determining the cross-correlation function has certain advantages. A new interpretation of the process of cross-correlation for time delay estimation is presented. To support the theoretical findings, analysis is carried out on test data from a specially constructed leak-detection facility located at a National Research Council site in Canada. Test results show that the time delay estimates and their variances calculated using time and frequency domain methods are almost identical.</abstract><cop>London</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.jsv.2007.02.023</doi><tpages>11</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0022-460X |
ispartof | Journal of sound and vibration, 2007-07, Vol.304 (1), p.213-223 |
issn | 0022-460X 1095-8568 |
language | eng |
recordid | cdi_proquest_miscellaneous_29897744 |
source | Elsevier ScienceDirect Journals Complete - AutoHoldings |
subjects | Acoustics Exact sciences and technology Fundamental areas of phenomenology (including applications) Physics Structural acoustics and vibration |
title | On the relationship between time and frequency domain methods in time delay estimation for leak detection in water distribution pipes |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T00%3A58%3A45IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=On%20the%20relationship%20between%20time%20and%20frequency%20domain%20methods%20in%20time%20delay%20estimation%20for%20leak%20detection%20in%20water%20distribution%20pipes&rft.jtitle=Journal%20of%20sound%20and%20vibration&rft.au=Brennan,%20M.J.&rft.date=2007-07-10&rft.volume=304&rft.issue=1&rft.spage=213&rft.epage=223&rft.pages=213-223&rft.issn=0022-460X&rft.eissn=1095-8568&rft.coden=JSVIAG&rft_id=info:doi/10.1016/j.jsv.2007.02.023&rft_dat=%3Cproquest_cross%3E29897744%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=29897744&rft_id=info:pmid/&rft_els_id=S0022460X07001423&rfr_iscdi=true |