Anti-Vibration Performance Proof Test for an Optimized Stiffness Distribution of Elasto-Plastic Joint Elements for Boiler Structures

Seismic ties are the connecting devices installed between a boiler and its supporting structure in thermal power plants. The seismic ties are made of steel and allowed to be used in the elasto-plastic deformation region in order to reduce the seismic response of the boiler structure. This paper deal...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nihon Kikai Gakkai ronbunshū. C 2004-01, Vol.16 (10), p.2817-2821
Hauptverfasser: Aida, Kiyoshi, Owa, Yasuyuki, Murayama, Naotomo, Kawamura, Koutaro, Suzuki, Kohei, Fujita, Satoshi, Chiba, Toshio
Format: Artikel
Sprache:jpn
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2821
container_issue 10
container_start_page 2817
container_title Nihon Kikai Gakkai ronbunshū. C
container_volume 16
creator Aida, Kiyoshi
Owa, Yasuyuki
Murayama, Naotomo
Kawamura, Koutaro
Suzuki, Kohei
Fujita, Satoshi
Chiba, Toshio
description Seismic ties are the connecting devices installed between a boiler and its supporting structure in thermal power plants. The seismic ties are made of steel and allowed to be used in the elasto-plastic deformation region in order to reduce the seismic response of the boiler structure. This paper deals with an anti-vibration performance proof test for an optimized stiffness distribution of elasto-plastic joint elements for boiler structures using a down-scaled boiler structure model on a large shaking table.
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_29884727</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>29884727</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_298847273</originalsourceid><addsrcrecordid>eNqNjUFLw0AQhfdQoUX7H-bkLbAk1STH2lbEiwGL17KJszCw2W1nZi-e_eGuxR_g6YPHe99bmJVturZ6sPVmadYiNFpr--axb7qV-d5GpeqDRnZKKcKA7BPPLk4IA6fk4YiiUDJwEd7OSjN94Se8K3kfUQT2JMo05uu89A_BiaZq-AVN8JooaglxxqhyFT0lCshFwXnSzCh35sa7ILj-4625fz4cdy_VmdMll__TTDJhCC5iynKq-67btHXb_Lv4AxqnVjo</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>29884727</pqid></control><display><type>article</type><title>Anti-Vibration Performance Proof Test for an Optimized Stiffness Distribution of Elasto-Plastic Joint Elements for Boiler Structures</title><source>J-STAGE Free</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Aida, Kiyoshi ; Owa, Yasuyuki ; Murayama, Naotomo ; Kawamura, Koutaro ; Suzuki, Kohei ; Fujita, Satoshi ; Chiba, Toshio</creator><creatorcontrib>Aida, Kiyoshi ; Owa, Yasuyuki ; Murayama, Naotomo ; Kawamura, Koutaro ; Suzuki, Kohei ; Fujita, Satoshi ; Chiba, Toshio</creatorcontrib><description>Seismic ties are the connecting devices installed between a boiler and its supporting structure in thermal power plants. The seismic ties are made of steel and allowed to be used in the elasto-plastic deformation region in order to reduce the seismic response of the boiler structure. This paper deals with an anti-vibration performance proof test for an optimized stiffness distribution of elasto-plastic joint elements for boiler structures using a down-scaled boiler structure model on a large shaking table.</description><identifier>ISSN: 0387-5024</identifier><language>jpn</language><ispartof>Nihon Kikai Gakkai ronbunshū. C, 2004-01, Vol.16 (10), p.2817-2821</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,778,782</link.rule.ids></links><search><creatorcontrib>Aida, Kiyoshi</creatorcontrib><creatorcontrib>Owa, Yasuyuki</creatorcontrib><creatorcontrib>Murayama, Naotomo</creatorcontrib><creatorcontrib>Kawamura, Koutaro</creatorcontrib><creatorcontrib>Suzuki, Kohei</creatorcontrib><creatorcontrib>Fujita, Satoshi</creatorcontrib><creatorcontrib>Chiba, Toshio</creatorcontrib><title>Anti-Vibration Performance Proof Test for an Optimized Stiffness Distribution of Elasto-Plastic Joint Elements for Boiler Structures</title><title>Nihon Kikai Gakkai ronbunshū. C</title><description>Seismic ties are the connecting devices installed between a boiler and its supporting structure in thermal power plants. The seismic ties are made of steel and allowed to be used in the elasto-plastic deformation region in order to reduce the seismic response of the boiler structure. This paper deals with an anti-vibration performance proof test for an optimized stiffness distribution of elasto-plastic joint elements for boiler structures using a down-scaled boiler structure model on a large shaking table.</description><issn>0387-5024</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><recordid>eNqNjUFLw0AQhfdQoUX7H-bkLbAk1STH2lbEiwGL17KJszCw2W1nZi-e_eGuxR_g6YPHe99bmJVturZ6sPVmadYiNFpr--axb7qV-d5GpeqDRnZKKcKA7BPPLk4IA6fk4YiiUDJwEd7OSjN94Se8K3kfUQT2JMo05uu89A_BiaZq-AVN8JooaglxxqhyFT0lCshFwXnSzCh35sa7ILj-4625fz4cdy_VmdMll__TTDJhCC5iynKq-67btHXb_Lv4AxqnVjo</recordid><startdate>20040101</startdate><enddate>20040101</enddate><creator>Aida, Kiyoshi</creator><creator>Owa, Yasuyuki</creator><creator>Murayama, Naotomo</creator><creator>Kawamura, Koutaro</creator><creator>Suzuki, Kohei</creator><creator>Fujita, Satoshi</creator><creator>Chiba, Toshio</creator><scope>7SM</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>20040101</creationdate><title>Anti-Vibration Performance Proof Test for an Optimized Stiffness Distribution of Elasto-Plastic Joint Elements for Boiler Structures</title><author>Aida, Kiyoshi ; Owa, Yasuyuki ; Murayama, Naotomo ; Kawamura, Koutaro ; Suzuki, Kohei ; Fujita, Satoshi ; Chiba, Toshio</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_298847273</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>jpn</language><creationdate>2004</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Aida, Kiyoshi</creatorcontrib><creatorcontrib>Owa, Yasuyuki</creatorcontrib><creatorcontrib>Murayama, Naotomo</creatorcontrib><creatorcontrib>Kawamura, Koutaro</creatorcontrib><creatorcontrib>Suzuki, Kohei</creatorcontrib><creatorcontrib>Fujita, Satoshi</creatorcontrib><creatorcontrib>Chiba, Toshio</creatorcontrib><collection>Earthquake Engineering Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Nihon Kikai Gakkai ronbunshū. C</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Aida, Kiyoshi</au><au>Owa, Yasuyuki</au><au>Murayama, Naotomo</au><au>Kawamura, Koutaro</au><au>Suzuki, Kohei</au><au>Fujita, Satoshi</au><au>Chiba, Toshio</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Anti-Vibration Performance Proof Test for an Optimized Stiffness Distribution of Elasto-Plastic Joint Elements for Boiler Structures</atitle><jtitle>Nihon Kikai Gakkai ronbunshū. C</jtitle><date>2004-01-01</date><risdate>2004</risdate><volume>16</volume><issue>10</issue><spage>2817</spage><epage>2821</epage><pages>2817-2821</pages><issn>0387-5024</issn><abstract>Seismic ties are the connecting devices installed between a boiler and its supporting structure in thermal power plants. The seismic ties are made of steel and allowed to be used in the elasto-plastic deformation region in order to reduce the seismic response of the boiler structure. This paper deals with an anti-vibration performance proof test for an optimized stiffness distribution of elasto-plastic joint elements for boiler structures using a down-scaled boiler structure model on a large shaking table.</abstract></addata></record>
fulltext fulltext
identifier ISSN: 0387-5024
ispartof Nihon Kikai Gakkai ronbunshū. C, 2004-01, Vol.16 (10), p.2817-2821
issn 0387-5024
language jpn
recordid cdi_proquest_miscellaneous_29884727
source J-STAGE Free; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
title Anti-Vibration Performance Proof Test for an Optimized Stiffness Distribution of Elasto-Plastic Joint Elements for Boiler Structures
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T11%3A00%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Anti-Vibration%20Performance%20Proof%20Test%20for%20an%20Optimized%20Stiffness%20Distribution%20of%20Elasto-Plastic%20Joint%20Elements%20for%20Boiler%20Structures&rft.jtitle=Nihon%20Kikai%20Gakkai%20ronbunsh%C5%AB.%20C&rft.au=Aida,%20Kiyoshi&rft.date=2004-01-01&rft.volume=16&rft.issue=10&rft.spage=2817&rft.epage=2821&rft.pages=2817-2821&rft.issn=0387-5024&rft_id=info:doi/&rft_dat=%3Cproquest%3E29884727%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=29884727&rft_id=info:pmid/&rfr_iscdi=true