Influence of Windfarms on Power System Dynamic and Transient Stability

The interaction between bulk windfarm generation and conventional generation and its influence on network dynamic characteristics are investigated. A simple three-generator system having characteristics that may be considered representative of the major areas of the UK network is used for the dynami...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Wind engineering 2006-03, Vol.30 (2), p.107-127
Hauptverfasser: Anaya-Lara, Olimpo, Hughes, F. Michael, Jenkins, Nicholas, Strbac, Goran
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 127
container_issue 2
container_start_page 107
container_title Wind engineering
container_volume 30
creator Anaya-Lara, Olimpo
Hughes, F. Michael
Jenkins, Nicholas
Strbac, Goran
description The interaction between bulk windfarm generation and conventional generation and its influence on network dynamic characteristics are investigated. A simple three-generator system having characteristics that may be considered representative of the major areas of the UK network is used for the dynamic studies. Time response simulation and eigenvalue analysis are used to establish basic transient and dynamic stability characteristics. The wind generation is provided either by windfarms based on Fixed Speed Induction Generators (FSIGs) or Doubly Fed Induction Generators (DFIGs). In addition, in order to provide a base-line, against which windfarm influence on network dynamics can be judged, the case where the power is provided only by conventional synchronous generation is also considered.
doi_str_mv 10.1260/030952406778055018
format Article
fullrecord <record><control><sourceid>jstor_proqu</sourceid><recordid>TN_cdi_proquest_miscellaneous_29763555</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><jstor_id>43856573</jstor_id><sage_id>10.1260_030952406778055018</sage_id><sourcerecordid>43856573</sourcerecordid><originalsourceid>FETCH-LOGICAL-c412t-30445905687829e61467e8c586281b13a1b97754f7aaae4c88273f3907fbadb3</originalsourceid><addsrcrecordid>eNqFkE1Lw0AQhhdRsFb_gCDsyVvs7PfmKNVqoaDQgr2FTbqRlGS37iZI_r0pES-CXmYuz_MO8yJ0TeCOUAkzYJAKykEqpUEIIPoETShwnXCg21M0OQLJQGzP0UWMewDCCeETtFi6su6sKyz2JX6r3K40oYnYO_zqP23A6z62tsEPvTNNVWDjdngTjIuVdS1etyav6qrtL9FZaepor773FG0Wj5v5c7J6eVrO71dJwQltEwacixSE1ErT1ErCpbK6EFpSTXLCDMlTpQQvlTHG8kJrqljJUlBlbnY5m6LbMfYQ_EdnY5s1VSxsXRtnfRczmirJhBD_g8C0ZMOcIjqCRfAxBltmh1A1JvQZgexYbfa72kGajVI07zbb-y644em_jZvR2MfWh58bnGkhhWLsC4H6gQs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>20386320</pqid></control><display><type>article</type><title>Influence of Windfarms on Power System Dynamic and Transient Stability</title><source>JSTOR Archive Collection A-Z Listing</source><source>SAGE Complete A-Z List</source><creator>Anaya-Lara, Olimpo ; Hughes, F. Michael ; Jenkins, Nicholas ; Strbac, Goran</creator><creatorcontrib>Anaya-Lara, Olimpo ; Hughes, F. Michael ; Jenkins, Nicholas ; Strbac, Goran</creatorcontrib><description>The interaction between bulk windfarm generation and conventional generation and its influence on network dynamic characteristics are investigated. A simple three-generator system having characteristics that may be considered representative of the major areas of the UK network is used for the dynamic studies. Time response simulation and eigenvalue analysis are used to establish basic transient and dynamic stability characteristics. The wind generation is provided either by windfarms based on Fixed Speed Induction Generators (FSIGs) or Doubly Fed Induction Generators (DFIGs). In addition, in order to provide a base-line, against which windfarm influence on network dynamics can be judged, the case where the power is provided only by conventional synchronous generation is also considered.</description><identifier>ISSN: 0309-524X</identifier><identifier>EISSN: 2048-402X</identifier><identifier>DOI: 10.1260/030952406778055018</identifier><language>eng</language><publisher>London, England: Multi-Science Publishing Company</publisher><subject>Clock synchronization ; Damping ; Dynamic stability ; Eigenvalues ; Electric generators ; Electric potential ; Modeling ; Stators ; Wind power ; Wind turbines</subject><ispartof>Wind engineering, 2006-03, Vol.30 (2), p.107-127</ispartof><rights>2006 SAGE Publications</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c412t-30445905687829e61467e8c586281b13a1b97754f7aaae4c88273f3907fbadb3</citedby><cites>FETCH-LOGICAL-c412t-30445905687829e61467e8c586281b13a1b97754f7aaae4c88273f3907fbadb3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.jstor.org/stable/pdf/43856573$$EPDF$$P50$$Gjstor$$H</linktopdf><linktohtml>$$Uhttps://www.jstor.org/stable/43856573$$EHTML$$P50$$Gjstor$$H</linktohtml><link.rule.ids>314,780,784,803,21818,27923,27924,43620,43621,58016,58249</link.rule.ids></links><search><creatorcontrib>Anaya-Lara, Olimpo</creatorcontrib><creatorcontrib>Hughes, F. Michael</creatorcontrib><creatorcontrib>Jenkins, Nicholas</creatorcontrib><creatorcontrib>Strbac, Goran</creatorcontrib><title>Influence of Windfarms on Power System Dynamic and Transient Stability</title><title>Wind engineering</title><description>The interaction between bulk windfarm generation and conventional generation and its influence on network dynamic characteristics are investigated. A simple three-generator system having characteristics that may be considered representative of the major areas of the UK network is used for the dynamic studies. Time response simulation and eigenvalue analysis are used to establish basic transient and dynamic stability characteristics. The wind generation is provided either by windfarms based on Fixed Speed Induction Generators (FSIGs) or Doubly Fed Induction Generators (DFIGs). In addition, in order to provide a base-line, against which windfarm influence on network dynamics can be judged, the case where the power is provided only by conventional synchronous generation is also considered.</description><subject>Clock synchronization</subject><subject>Damping</subject><subject>Dynamic stability</subject><subject>Eigenvalues</subject><subject>Electric generators</subject><subject>Electric potential</subject><subject>Modeling</subject><subject>Stators</subject><subject>Wind power</subject><subject>Wind turbines</subject><issn>0309-524X</issn><issn>2048-402X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNqFkE1Lw0AQhhdRsFb_gCDsyVvs7PfmKNVqoaDQgr2FTbqRlGS37iZI_r0pES-CXmYuz_MO8yJ0TeCOUAkzYJAKykEqpUEIIPoETShwnXCg21M0OQLJQGzP0UWMewDCCeETtFi6su6sKyz2JX6r3K40oYnYO_zqP23A6z62tsEPvTNNVWDjdngTjIuVdS1etyav6qrtL9FZaepor773FG0Wj5v5c7J6eVrO71dJwQltEwacixSE1ErT1ErCpbK6EFpSTXLCDMlTpQQvlTHG8kJrqljJUlBlbnY5m6LbMfYQ_EdnY5s1VSxsXRtnfRczmirJhBD_g8C0ZMOcIjqCRfAxBltmh1A1JvQZgexYbfa72kGajVI07zbb-y644em_jZvR2MfWh58bnGkhhWLsC4H6gQs</recordid><startdate>20060301</startdate><enddate>20060301</enddate><creator>Anaya-Lara, Olimpo</creator><creator>Hughes, F. Michael</creator><creator>Jenkins, Nicholas</creator><creator>Strbac, Goran</creator><general>Multi-Science Publishing Company</general><general>SAGE Publications</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>7U6</scope><scope>C1K</scope><scope>7SP</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope><scope>L7M</scope></search><sort><creationdate>20060301</creationdate><title>Influence of Windfarms on Power System Dynamic and Transient Stability</title><author>Anaya-Lara, Olimpo ; Hughes, F. Michael ; Jenkins, Nicholas ; Strbac, Goran</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c412t-30445905687829e61467e8c586281b13a1b97754f7aaae4c88273f3907fbadb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Clock synchronization</topic><topic>Damping</topic><topic>Dynamic stability</topic><topic>Eigenvalues</topic><topic>Electric generators</topic><topic>Electric potential</topic><topic>Modeling</topic><topic>Stators</topic><topic>Wind power</topic><topic>Wind turbines</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Anaya-Lara, Olimpo</creatorcontrib><creatorcontrib>Hughes, F. Michael</creatorcontrib><creatorcontrib>Jenkins, Nicholas</creatorcontrib><creatorcontrib>Strbac, Goran</creatorcontrib><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Sustainability Science Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Wind engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Anaya-Lara, Olimpo</au><au>Hughes, F. Michael</au><au>Jenkins, Nicholas</au><au>Strbac, Goran</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Influence of Windfarms on Power System Dynamic and Transient Stability</atitle><jtitle>Wind engineering</jtitle><date>2006-03-01</date><risdate>2006</risdate><volume>30</volume><issue>2</issue><spage>107</spage><epage>127</epage><pages>107-127</pages><issn>0309-524X</issn><eissn>2048-402X</eissn><abstract>The interaction between bulk windfarm generation and conventional generation and its influence on network dynamic characteristics are investigated. A simple three-generator system having characteristics that may be considered representative of the major areas of the UK network is used for the dynamic studies. Time response simulation and eigenvalue analysis are used to establish basic transient and dynamic stability characteristics. The wind generation is provided either by windfarms based on Fixed Speed Induction Generators (FSIGs) or Doubly Fed Induction Generators (DFIGs). In addition, in order to provide a base-line, against which windfarm influence on network dynamics can be judged, the case where the power is provided only by conventional synchronous generation is also considered.</abstract><cop>London, England</cop><pub>Multi-Science Publishing Company</pub><doi>10.1260/030952406778055018</doi><tpages>21</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0309-524X
ispartof Wind engineering, 2006-03, Vol.30 (2), p.107-127
issn 0309-524X
2048-402X
language eng
recordid cdi_proquest_miscellaneous_29763555
source JSTOR Archive Collection A-Z Listing; SAGE Complete A-Z List
subjects Clock synchronization
Damping
Dynamic stability
Eigenvalues
Electric generators
Electric potential
Modeling
Stators
Wind power
Wind turbines
title Influence of Windfarms on Power System Dynamic and Transient Stability
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T11%3A31%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-jstor_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Influence%20of%20Windfarms%20on%20Power%20System%20Dynamic%20and%20Transient%20Stability&rft.jtitle=Wind%20engineering&rft.au=Anaya-Lara,%20Olimpo&rft.date=2006-03-01&rft.volume=30&rft.issue=2&rft.spage=107&rft.epage=127&rft.pages=107-127&rft.issn=0309-524X&rft.eissn=2048-402X&rft_id=info:doi/10.1260/030952406778055018&rft_dat=%3Cjstor_proqu%3E43856573%3C/jstor_proqu%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=20386320&rft_id=info:pmid/&rft_jstor_id=43856573&rft_sage_id=10.1260_030952406778055018&rfr_iscdi=true