Rapid radiation degradation in the XPS analysis of antibacterial coatings of brominated furanones

Brominated furanones are promising antibacterial compounds, both in solution and immobilized on solid surfaces, and there is interest in their utilization as protective coatings on biomedical devices to combat device‐centered infections. The rational design and optimization of antibacterial furanone...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Surface and interface analysis 2006-11, Vol.38 (11), p.1512-1518
Hauptverfasser: Al-Bataineh, Sameer A., Britcher, Leanne G., Griesser, Hans J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1518
container_issue 11
container_start_page 1512
container_title Surface and interface analysis
container_volume 38
creator Al-Bataineh, Sameer A.
Britcher, Leanne G.
Griesser, Hans J.
description Brominated furanones are promising antibacterial compounds, both in solution and immobilized on solid surfaces, and there is interest in their utilization as protective coatings on biomedical devices to combat device‐centered infections. The rational design and optimization of antibacterial furanone coatings requires detailed spectroscopic surface characterization of the coatings produced and correlation of surface analysis data with antibacterial performance. However, as reported in this study, the extreme sensitivity of brominated furanones to radiation damage in the course of XPS analysis greatly complicates characterization. Our data show that rapid degradation occurs, as shown by the emergence of a signal assignable to Br− ion in the Br 3d spectrum. This Br− is water soluble as shown by washing experiments, whereas the CBr signal does not become reduced during washing, consistent with covalent interfacial immobilization of the furanone molecules. Furanone molecules were immobilized onto two different hydrogel interlayers (polyacrylic acid and polyethylene oxide (PEO)), and XPS analyses show that the interlayers did not suffer significant radiation degradation; the damage is limited to the furanone molecules. The results of this study may assist in XPS analyses of other brominated compounds on surfaces; the possibility of Br− ions deriving from XPS analysis–damage must be investigated before assigning their generation to side reactions in the coating or surface‐modification procedure. Copyright © 2006 John Wiley & Sons, Ltd.
doi_str_mv 10.1002/sia.2387
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_29604046</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>29604046</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3347-c3bb5f629a49f65d3b1a0308214aa9c3f64c2a662be06e02fb29bd9584406dd23</originalsourceid><addsrcrecordid>eNp10E1LwzAYB_AgCs4p-BF6Ei-deWvaHGXqNhgqmzLxEp60yYx27Uw6dN_ezorgwcvzwvPjOfwROiV4QDCmF8HBgLIs3UM9gqWIpSTZPuphwmlMOSWH6CiEV4xxxjLRQzCDtSsiD4WDxtVVVJhlu3Szq6LmxURP9_MIKii3wYWotu3cOA15Y7yDMsrrFlfL74v29cpV0JgishsPVV2ZcIwOLJTBnPz0Pnq8uX4YjuPp3WgyvJzGOWM8bavWiRVUApdWJAXTBDDDGSUcQObMCp5TEIJqg4XB1GoqdSGTjHMsioKyPjrr_q59_b4xoVErF3JTllCZehMUlQJzzEULzzuY-zoEb6xae7cCv1UEq12Gqs1Q7TJsadzRD1ea7b9OzSeXf70Ljfn89eDflEhZmqjF7UjNkvFi8TzM1BX7AkfBgtA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>29604046</pqid></control><display><type>article</type><title>Rapid radiation degradation in the XPS analysis of antibacterial coatings of brominated furanones</title><source>Wiley Journals</source><creator>Al-Bataineh, Sameer A. ; Britcher, Leanne G. ; Griesser, Hans J.</creator><creatorcontrib>Al-Bataineh, Sameer A. ; Britcher, Leanne G. ; Griesser, Hans J.</creatorcontrib><description>Brominated furanones are promising antibacterial compounds, both in solution and immobilized on solid surfaces, and there is interest in their utilization as protective coatings on biomedical devices to combat device‐centered infections. The rational design and optimization of antibacterial furanone coatings requires detailed spectroscopic surface characterization of the coatings produced and correlation of surface analysis data with antibacterial performance. However, as reported in this study, the extreme sensitivity of brominated furanones to radiation damage in the course of XPS analysis greatly complicates characterization. Our data show that rapid degradation occurs, as shown by the emergence of a signal assignable to Br− ion in the Br 3d spectrum. This Br− is water soluble as shown by washing experiments, whereas the CBr signal does not become reduced during washing, consistent with covalent interfacial immobilization of the furanone molecules. Furanone molecules were immobilized onto two different hydrogel interlayers (polyacrylic acid and polyethylene oxide (PEO)), and XPS analyses show that the interlayers did not suffer significant radiation degradation; the damage is limited to the furanone molecules. The results of this study may assist in XPS analyses of other brominated compounds on surfaces; the possibility of Br− ions deriving from XPS analysis–damage must be investigated before assigning their generation to side reactions in the coating or surface‐modification procedure. Copyright © 2006 John Wiley &amp; Sons, Ltd.</description><identifier>ISSN: 0142-2421</identifier><identifier>EISSN: 1096-9918</identifier><identifier>DOI: 10.1002/sia.2387</identifier><language>eng</language><publisher>Chichester, UK: John Wiley &amp; Sons, Ltd</publisher><subject>antibacterial coating ; furanone ; PEO ; surface characterization ; surface modification ; XPS</subject><ispartof>Surface and interface analysis, 2006-11, Vol.38 (11), p.1512-1518</ispartof><rights>Copyright © 2006 John Wiley &amp; Sons, Ltd.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3347-c3bb5f629a49f65d3b1a0308214aa9c3f64c2a662be06e02fb29bd9584406dd23</citedby><cites>FETCH-LOGICAL-c3347-c3bb5f629a49f65d3b1a0308214aa9c3f64c2a662be06e02fb29bd9584406dd23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fsia.2387$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fsia.2387$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45574,45575</link.rule.ids></links><search><creatorcontrib>Al-Bataineh, Sameer A.</creatorcontrib><creatorcontrib>Britcher, Leanne G.</creatorcontrib><creatorcontrib>Griesser, Hans J.</creatorcontrib><title>Rapid radiation degradation in the XPS analysis of antibacterial coatings of brominated furanones</title><title>Surface and interface analysis</title><addtitle>Surf. Interface Anal</addtitle><description>Brominated furanones are promising antibacterial compounds, both in solution and immobilized on solid surfaces, and there is interest in their utilization as protective coatings on biomedical devices to combat device‐centered infections. The rational design and optimization of antibacterial furanone coatings requires detailed spectroscopic surface characterization of the coatings produced and correlation of surface analysis data with antibacterial performance. However, as reported in this study, the extreme sensitivity of brominated furanones to radiation damage in the course of XPS analysis greatly complicates characterization. Our data show that rapid degradation occurs, as shown by the emergence of a signal assignable to Br− ion in the Br 3d spectrum. This Br− is water soluble as shown by washing experiments, whereas the CBr signal does not become reduced during washing, consistent with covalent interfacial immobilization of the furanone molecules. Furanone molecules were immobilized onto two different hydrogel interlayers (polyacrylic acid and polyethylene oxide (PEO)), and XPS analyses show that the interlayers did not suffer significant radiation degradation; the damage is limited to the furanone molecules. The results of this study may assist in XPS analyses of other brominated compounds on surfaces; the possibility of Br− ions deriving from XPS analysis–damage must be investigated before assigning their generation to side reactions in the coating or surface‐modification procedure. Copyright © 2006 John Wiley &amp; Sons, Ltd.</description><subject>antibacterial coating</subject><subject>furanone</subject><subject>PEO</subject><subject>surface characterization</subject><subject>surface modification</subject><subject>XPS</subject><issn>0142-2421</issn><issn>1096-9918</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNp10E1LwzAYB_AgCs4p-BF6Ei-deWvaHGXqNhgqmzLxEp60yYx27Uw6dN_ezorgwcvzwvPjOfwROiV4QDCmF8HBgLIs3UM9gqWIpSTZPuphwmlMOSWH6CiEV4xxxjLRQzCDtSsiD4WDxtVVVJhlu3Szq6LmxURP9_MIKii3wYWotu3cOA15Y7yDMsrrFlfL74v29cpV0JgishsPVV2ZcIwOLJTBnPz0Pnq8uX4YjuPp3WgyvJzGOWM8bavWiRVUApdWJAXTBDDDGSUcQObMCp5TEIJqg4XB1GoqdSGTjHMsioKyPjrr_q59_b4xoVErF3JTllCZehMUlQJzzEULzzuY-zoEb6xae7cCv1UEq12Gqs1Q7TJsadzRD1ea7b9OzSeXf70Ljfn89eDflEhZmqjF7UjNkvFi8TzM1BX7AkfBgtA</recordid><startdate>200611</startdate><enddate>200611</enddate><creator>Al-Bataineh, Sameer A.</creator><creator>Britcher, Leanne G.</creator><creator>Griesser, Hans J.</creator><general>John Wiley &amp; Sons, Ltd</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>200611</creationdate><title>Rapid radiation degradation in the XPS analysis of antibacterial coatings of brominated furanones</title><author>Al-Bataineh, Sameer A. ; Britcher, Leanne G. ; Griesser, Hans J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3347-c3bb5f629a49f65d3b1a0308214aa9c3f64c2a662be06e02fb29bd9584406dd23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>antibacterial coating</topic><topic>furanone</topic><topic>PEO</topic><topic>surface characterization</topic><topic>surface modification</topic><topic>XPS</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Al-Bataineh, Sameer A.</creatorcontrib><creatorcontrib>Britcher, Leanne G.</creatorcontrib><creatorcontrib>Griesser, Hans J.</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Surface and interface analysis</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Al-Bataineh, Sameer A.</au><au>Britcher, Leanne G.</au><au>Griesser, Hans J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Rapid radiation degradation in the XPS analysis of antibacterial coatings of brominated furanones</atitle><jtitle>Surface and interface analysis</jtitle><addtitle>Surf. Interface Anal</addtitle><date>2006-11</date><risdate>2006</risdate><volume>38</volume><issue>11</issue><spage>1512</spage><epage>1518</epage><pages>1512-1518</pages><issn>0142-2421</issn><eissn>1096-9918</eissn><abstract>Brominated furanones are promising antibacterial compounds, both in solution and immobilized on solid surfaces, and there is interest in their utilization as protective coatings on biomedical devices to combat device‐centered infections. The rational design and optimization of antibacterial furanone coatings requires detailed spectroscopic surface characterization of the coatings produced and correlation of surface analysis data with antibacterial performance. However, as reported in this study, the extreme sensitivity of brominated furanones to radiation damage in the course of XPS analysis greatly complicates characterization. Our data show that rapid degradation occurs, as shown by the emergence of a signal assignable to Br− ion in the Br 3d spectrum. This Br− is water soluble as shown by washing experiments, whereas the CBr signal does not become reduced during washing, consistent with covalent interfacial immobilization of the furanone molecules. Furanone molecules were immobilized onto two different hydrogel interlayers (polyacrylic acid and polyethylene oxide (PEO)), and XPS analyses show that the interlayers did not suffer significant radiation degradation; the damage is limited to the furanone molecules. The results of this study may assist in XPS analyses of other brominated compounds on surfaces; the possibility of Br− ions deriving from XPS analysis–damage must be investigated before assigning their generation to side reactions in the coating or surface‐modification procedure. Copyright © 2006 John Wiley &amp; Sons, Ltd.</abstract><cop>Chichester, UK</cop><pub>John Wiley &amp; Sons, Ltd</pub><doi>10.1002/sia.2387</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0142-2421
ispartof Surface and interface analysis, 2006-11, Vol.38 (11), p.1512-1518
issn 0142-2421
1096-9918
language eng
recordid cdi_proquest_miscellaneous_29604046
source Wiley Journals
subjects antibacterial coating
furanone
PEO
surface characterization
surface modification
XPS
title Rapid radiation degradation in the XPS analysis of antibacterial coatings of brominated furanones
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T13%3A36%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Rapid%20radiation%20degradation%20in%20the%20XPS%20analysis%20of%20antibacterial%20coatings%20of%20brominated%20furanones&rft.jtitle=Surface%20and%20interface%20analysis&rft.au=Al-Bataineh,%20Sameer%20A.&rft.date=2006-11&rft.volume=38&rft.issue=11&rft.spage=1512&rft.epage=1518&rft.pages=1512-1518&rft.issn=0142-2421&rft.eissn=1096-9918&rft_id=info:doi/10.1002/sia.2387&rft_dat=%3Cproquest_cross%3E29604046%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=29604046&rft_id=info:pmid/&rfr_iscdi=true