"Right sizing" circuit breakers in motor starters
Instantaneous-trip, molded-case circuit breakers (MCCBs) have been applied successfully for low-voltage motor protection for many years. However, the changes in motor-starting characteristics have created more difficult challenges for the application engineer. The major challenge is successfully sta...
Gespeichert in:
Veröffentlicht in: | IEEE industry applications magazine 2000-09, Vol.6 (5), p.23-32 |
---|---|
Hauptverfasser: | , |
Format: | Magazinearticle |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 32 |
---|---|
container_issue | 5 |
container_start_page | 23 |
container_title | IEEE industry applications magazine |
container_volume | 6 |
creator | Padden, L.K. Gregory, G.D. |
description | Instantaneous-trip, molded-case circuit breakers (MCCBs) have been applied successfully for low-voltage motor protection for many years. However, the changes in motor-starting characteristics have created more difficult challenges for the application engineer. The major challenge is successfully starting the low-voltage motor without causing the instantaneous-trip breaker to falsely trip without exceeding equipment ratings or violating limitations in the National Electrical Code (NEC). "Right sizing" circuit breakers for use in low-voltage combination motor starters is critical to the successful, reliable operation of plant and process facilities. If not properly applied, false tripping on motor starting and contact welding of contactors may occur. Moreover, changes in the NEC and improved motor efficiencies have impacted equipment selection and protection. The following information is intended to guide application engineers in their selection of the right breaker and its setting for more reliable motor protection: combination motor-starter components, circuit breaker characteristics, circuit breaker and combination. starter testing, motor starting characteristics, and component selection using coordination examples. The examples show how selecting the right breaker and breaker setting can avoid false tripping during starting, mitigate contact welding, and provide backup protection for overload conditions. |
doi_str_mv | 10.1109/2943.863632 |
format | Magazinearticle |
fullrecord | <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_proquest_miscellaneous_29549440</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>863632</ieee_id><sourcerecordid>28785508</sourcerecordid><originalsourceid>FETCH-LOGICAL-c360t-51081da36d52ec1dbe1211a6467838921836e6fa94a98581b4899aa7499f572b3</originalsourceid><addsrcrecordid>eNqF0T1PwzAQBmALgUQpTGxMUQcYUIrP8cd5RBVfUiUkBLPlpE5xaZtiJwP8elylYmCg053uHt1wLyHnQMcAVN8wzYsxykIW7IAMQAjMqdB4mHqqVM4k4DE5iXFBKXCu1IDA6MXP39ss-m-_no-yyoeq821WBmc_XIiZX2erpm1CFlsb2jQ5JUe1XUZ3tqtD8nZ_9zp5zKfPD0-T22leFZK2uQCKMLOFnAnmKpiVDhiAlVwqLFAzwEI6WVvNrUaBUHLU2lrFta6FYmUxJFf93U1oPjsXW7PysXLLpV27potGA5ecouJJXv4rmRZcc073Q1QoBMX9UElUSSc4-gMXTRfW6S8GUaRMhGAJXfeoCk2MwdVmE_zKhi8D1GxzM9vcTJ9b0he99s65X7lb_gCpNo6t</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>magazinearticle</recordtype><pqid>885110552</pqid></control><display><type>magazinearticle</type><title>"Right sizing" circuit breakers in motor starters</title><source>IEEE/IET Electronic Library (IEL)</source><creator>Padden, L.K. ; Gregory, G.D.</creator><creatorcontrib>Padden, L.K. ; Gregory, G.D.</creatorcontrib><description>Instantaneous-trip, molded-case circuit breakers (MCCBs) have been applied successfully for low-voltage motor protection for many years. However, the changes in motor-starting characteristics have created more difficult challenges for the application engineer. The major challenge is successfully starting the low-voltage motor without causing the instantaneous-trip breaker to falsely trip without exceeding equipment ratings or violating limitations in the National Electrical Code (NEC). "Right sizing" circuit breakers for use in low-voltage combination motor starters is critical to the successful, reliable operation of plant and process facilities. If not properly applied, false tripping on motor starting and contact welding of contactors may occur. Moreover, changes in the NEC and improved motor efficiencies have impacted equipment selection and protection. The following information is intended to guide application engineers in their selection of the right breaker and its setting for more reliable motor protection: combination motor-starter components, circuit breaker characteristics, circuit breaker and combination. starter testing, motor starting characteristics, and component selection using coordination examples. The examples show how selecting the right breaker and breaker setting can avoid false tripping during starting, mitigate contact welding, and provide backup protection for overload conditions.</description><identifier>ISSN: 1077-2618</identifier><identifier>EISSN: 1558-0598</identifier><identifier>DOI: 10.1109/2943.863632</identifier><identifier>CODEN: IIAMEG</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Backups ; Circuit breakers ; Circuit protection ; Contact ; Electric contacts ; Electrical codes ; Energy efficiency ; Engineers ; Motor drives ; Motors ; National electric code ; Protection ; Protective relaying ; Relays ; Rotors ; Sizing ; Starters ; Switches ; Voltage ; Welding</subject><ispartof>IEEE industry applications magazine, 2000-09, Vol.6 (5), p.23-32</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2000</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c360t-51081da36d52ec1dbe1211a6467838921836e6fa94a98581b4899aa7499f572b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/863632$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>776,780,792,27902,54733</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/863632$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Padden, L.K.</creatorcontrib><creatorcontrib>Gregory, G.D.</creatorcontrib><title>"Right sizing" circuit breakers in motor starters</title><title>IEEE industry applications magazine</title><addtitle>MIAS</addtitle><description>Instantaneous-trip, molded-case circuit breakers (MCCBs) have been applied successfully for low-voltage motor protection for many years. However, the changes in motor-starting characteristics have created more difficult challenges for the application engineer. The major challenge is successfully starting the low-voltage motor without causing the instantaneous-trip breaker to falsely trip without exceeding equipment ratings or violating limitations in the National Electrical Code (NEC). "Right sizing" circuit breakers for use in low-voltage combination motor starters is critical to the successful, reliable operation of plant and process facilities. If not properly applied, false tripping on motor starting and contact welding of contactors may occur. Moreover, changes in the NEC and improved motor efficiencies have impacted equipment selection and protection. The following information is intended to guide application engineers in their selection of the right breaker and its setting for more reliable motor protection: combination motor-starter components, circuit breaker characteristics, circuit breaker and combination. starter testing, motor starting characteristics, and component selection using coordination examples. The examples show how selecting the right breaker and breaker setting can avoid false tripping during starting, mitigate contact welding, and provide backup protection for overload conditions.</description><subject>Backups</subject><subject>Circuit breakers</subject><subject>Circuit protection</subject><subject>Contact</subject><subject>Electric contacts</subject><subject>Electrical codes</subject><subject>Energy efficiency</subject><subject>Engineers</subject><subject>Motor drives</subject><subject>Motors</subject><subject>National electric code</subject><subject>Protection</subject><subject>Protective relaying</subject><subject>Relays</subject><subject>Rotors</subject><subject>Sizing</subject><subject>Starters</subject><subject>Switches</subject><subject>Voltage</subject><subject>Welding</subject><issn>1077-2618</issn><issn>1558-0598</issn><fulltext>true</fulltext><rsrctype>magazinearticle</rsrctype><creationdate>2000</creationdate><recordtype>magazinearticle</recordtype><sourceid>RIE</sourceid><recordid>eNqF0T1PwzAQBmALgUQpTGxMUQcYUIrP8cd5RBVfUiUkBLPlpE5xaZtiJwP8elylYmCg053uHt1wLyHnQMcAVN8wzYsxykIW7IAMQAjMqdB4mHqqVM4k4DE5iXFBKXCu1IDA6MXP39ss-m-_no-yyoeq821WBmc_XIiZX2erpm1CFlsb2jQ5JUe1XUZ3tqtD8nZ_9zp5zKfPD0-T22leFZK2uQCKMLOFnAnmKpiVDhiAlVwqLFAzwEI6WVvNrUaBUHLU2lrFta6FYmUxJFf93U1oPjsXW7PysXLLpV27potGA5ecouJJXv4rmRZcc073Q1QoBMX9UElUSSc4-gMXTRfW6S8GUaRMhGAJXfeoCk2MwdVmE_zKhi8D1GxzM9vcTJ9b0he99s65X7lb_gCpNo6t</recordid><startdate>20000901</startdate><enddate>20000901</enddate><creator>Padden, L.K.</creator><creator>Gregory, G.D.</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>8FD</scope><scope>L7M</scope><scope>7TB</scope><scope>FR3</scope><scope>F28</scope></search><sort><creationdate>20000901</creationdate><title>"Right sizing" circuit breakers in motor starters</title><author>Padden, L.K. ; Gregory, G.D.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c360t-51081da36d52ec1dbe1211a6467838921836e6fa94a98581b4899aa7499f572b3</frbrgroupid><rsrctype>magazinearticle</rsrctype><prefilter>magazinearticle</prefilter><language>eng</language><creationdate>2000</creationdate><topic>Backups</topic><topic>Circuit breakers</topic><topic>Circuit protection</topic><topic>Contact</topic><topic>Electric contacts</topic><topic>Electrical codes</topic><topic>Energy efficiency</topic><topic>Engineers</topic><topic>Motor drives</topic><topic>Motors</topic><topic>National electric code</topic><topic>Protection</topic><topic>Protective relaying</topic><topic>Relays</topic><topic>Rotors</topic><topic>Sizing</topic><topic>Starters</topic><topic>Switches</topic><topic>Voltage</topic><topic>Welding</topic><toplevel>online_resources</toplevel><creatorcontrib>Padden, L.K.</creatorcontrib><creatorcontrib>Gregory, G.D.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE/IET Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Engineering Research Database</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><jtitle>IEEE industry applications magazine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Padden, L.K.</au><au>Gregory, G.D.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>"Right sizing" circuit breakers in motor starters</atitle><jtitle>IEEE industry applications magazine</jtitle><stitle>MIAS</stitle><date>2000-09-01</date><risdate>2000</risdate><volume>6</volume><issue>5</issue><spage>23</spage><epage>32</epage><pages>23-32</pages><issn>1077-2618</issn><eissn>1558-0598</eissn><coden>IIAMEG</coden><abstract>Instantaneous-trip, molded-case circuit breakers (MCCBs) have been applied successfully for low-voltage motor protection for many years. However, the changes in motor-starting characteristics have created more difficult challenges for the application engineer. The major challenge is successfully starting the low-voltage motor without causing the instantaneous-trip breaker to falsely trip without exceeding equipment ratings or violating limitations in the National Electrical Code (NEC). "Right sizing" circuit breakers for use in low-voltage combination motor starters is critical to the successful, reliable operation of plant and process facilities. If not properly applied, false tripping on motor starting and contact welding of contactors may occur. Moreover, changes in the NEC and improved motor efficiencies have impacted equipment selection and protection. The following information is intended to guide application engineers in their selection of the right breaker and its setting for more reliable motor protection: combination motor-starter components, circuit breaker characteristics, circuit breaker and combination. starter testing, motor starting characteristics, and component selection using coordination examples. The examples show how selecting the right breaker and breaker setting can avoid false tripping during starting, mitigate contact welding, and provide backup protection for overload conditions.</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/2943.863632</doi><tpages>10</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 1077-2618 |
ispartof | IEEE industry applications magazine, 2000-09, Vol.6 (5), p.23-32 |
issn | 1077-2618 1558-0598 |
language | eng |
recordid | cdi_proquest_miscellaneous_29549440 |
source | IEEE/IET Electronic Library (IEL) |
subjects | Backups Circuit breakers Circuit protection Contact Electric contacts Electrical codes Energy efficiency Engineers Motor drives Motors National electric code Protection Protective relaying Relays Rotors Sizing Starters Switches Voltage Welding |
title | "Right sizing" circuit breakers in motor starters |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-11T23%3A28%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=%22Right%20sizing%22%20circuit%20breakers%20in%20motor%20starters&rft.jtitle=IEEE%20industry%20applications%20magazine&rft.au=Padden,%20L.K.&rft.date=2000-09-01&rft.volume=6&rft.issue=5&rft.spage=23&rft.epage=32&rft.pages=23-32&rft.issn=1077-2618&rft.eissn=1558-0598&rft.coden=IIAMEG&rft_id=info:doi/10.1109/2943.863632&rft_dat=%3Cproquest_RIE%3E28785508%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=885110552&rft_id=info:pmid/&rft_ieee_id=863632&rfr_iscdi=true |