Development of an insulin-like growth factor-1 certified reference material by SI-traceable isotope-dilution mass spectrometry

In this study, an insulin-like growth factor-1 (IGF-1) certified reference material (CRM) was developed by the National Institute of Metrology (NIM), and two different principles for evaluating the IGF-1 CRM were established. After optimisation of the acid hydrolysis conditions (110 °C, 36 h), quant...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2024-06, Vol.273, p.125812-125812, Article 125812
Hauptverfasser: Liu, Zihan, Zhao, Xu, Liu, Yahui, Shi, Lianhua, Wu, Liqing, Yuan, Hui, Jin, Youxun
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 125812
container_issue
container_start_page 125812
container_title Talanta (Oxford)
container_volume 273
creator Liu, Zihan
Zhao, Xu
Liu, Yahui
Shi, Lianhua
Wu, Liqing
Yuan, Hui
Jin, Youxun
description In this study, an insulin-like growth factor-1 (IGF-1) certified reference material (CRM) was developed by the National Institute of Metrology (NIM), and two different principles for evaluating the IGF-1 CRM were established. After optimisation of the acid hydrolysis conditions (110 °C, 36 h), quantitative determination of peptide purity, and chromatographic separation and mass spectrometric detection, amino acid analysis-based high-performance liquid chromatography combined with isotope-dilution tandem mass spectrometry (AAA-HPLC-IDMS/MS) and peptide analysis-based HPLC-IDMS/MS (Peptide-HPLC-IDMS/MS) were used for certified value assignment; the results obtained were 136.28 and 135.01 μg/g, respectively, which were in good agreement. These results were subjected to the normal distribution test, outlier test, and method consistency test. The homogeneity and stability of the reference materials were also examined, and the uncertainty introduced in the experimental process was calculated. The final certified value was (136 ± 15) μg g−1 (k = 2). The CRM was found to be stable for at least six months when stored at −70 °C and for 7 d when stored at higher temperatures (−20 °C, 4 °C, 25 °C, or 40 °C). The CRM is expected to be used as a primary calibrator for quality control in biopharmaceutical production and clinical diagnostics. [Display omitted] •IGF-1 CRM was developed by the National Institute of Metrology (NIM).•AAA-HPLC-IDMS/MS and Peptide-HPLC-IDMS/MS used to evaluate IGF-1 CRM.•CRM was stable for at least 6 months at −70 °C and for 7 d at higher temperatures.
doi_str_mv 10.1016/j.talanta.2024.125812
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2954769756</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0039914024001917</els_id><sourcerecordid>2954769756</sourcerecordid><originalsourceid>FETCH-LOGICAL-c313t-cc7135f6c0df3e924aaab54bf7148da4a8a9fef0fdec7840f56b1350863f3df33</originalsourceid><addsrcrecordid>eNqFkE2PFCEQQInRuOPqT9Bw9MIIDfTHyZj1a5NNPKhnUk0Xykg3LdBr5uJvl8mMXj3V5b2q1CPkueB7wUX76rAvEGApsG94o_ai0b1oHpCd6DvJpO7kQ7LjXA5sEIpfkSc5HzjnjeTyMbmSvdJVGHbk91u8xxDXGZdCo6OwUL_kLfiFBf8D6bcUf5Xv1IEtMTFBLabinceJJnSYcLFIZyiYPAQ6HunnW1YSWIQxIPU5lrgim3zYio9LJXOmeUVbUpyxpONT8shByPjsMq_J1_fvvtx8ZHefPtzevLljVgpZmLWdkNq1lk9O4tAoABi1Gl0nVD-Bgh4Gh467CW3XK-50O1aB9610sirymrw8711T_LlhLmb22WKoBTFu2TSDVl07dLqtqD6jNsWc65dmTX6GdDSCm1N6czCX9OaU3pzTV-_F5cQ2zjj9s_62rsDrM4D10XuPyWTrTwEnn2oRM0X_nxN_AL0amuA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2954769756</pqid></control><display><type>article</type><title>Development of an insulin-like growth factor-1 certified reference material by SI-traceable isotope-dilution mass spectrometry</title><source>Elsevier ScienceDirect Journals</source><creator>Liu, Zihan ; Zhao, Xu ; Liu, Yahui ; Shi, Lianhua ; Wu, Liqing ; Yuan, Hui ; Jin, Youxun</creator><creatorcontrib>Liu, Zihan ; Zhao, Xu ; Liu, Yahui ; Shi, Lianhua ; Wu, Liqing ; Yuan, Hui ; Jin, Youxun</creatorcontrib><description>In this study, an insulin-like growth factor-1 (IGF-1) certified reference material (CRM) was developed by the National Institute of Metrology (NIM), and two different principles for evaluating the IGF-1 CRM were established. After optimisation of the acid hydrolysis conditions (110 °C, 36 h), quantitative determination of peptide purity, and chromatographic separation and mass spectrometric detection, amino acid analysis-based high-performance liquid chromatography combined with isotope-dilution tandem mass spectrometry (AAA-HPLC-IDMS/MS) and peptide analysis-based HPLC-IDMS/MS (Peptide-HPLC-IDMS/MS) were used for certified value assignment; the results obtained were 136.28 and 135.01 μg/g, respectively, which were in good agreement. These results were subjected to the normal distribution test, outlier test, and method consistency test. The homogeneity and stability of the reference materials were also examined, and the uncertainty introduced in the experimental process was calculated. The final certified value was (136 ± 15) μg g−1 (k = 2). The CRM was found to be stable for at least six months when stored at −70 °C and for 7 d when stored at higher temperatures (−20 °C, 4 °C, 25 °C, or 40 °C). The CRM is expected to be used as a primary calibrator for quality control in biopharmaceutical production and clinical diagnostics. [Display omitted] •IGF-1 CRM was developed by the National Institute of Metrology (NIM).•AAA-HPLC-IDMS/MS and Peptide-HPLC-IDMS/MS used to evaluate IGF-1 CRM.•CRM was stable for at least 6 months at −70 °C and for 7 d at higher temperatures.</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/j.talanta.2024.125812</identifier><identifier>PMID: 38452589</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>AAA-HPLC-IDMS/MS ; IGF-1 CRM ; LC-MS ; Peptide-HPLC-IDMS/MS</subject><ispartof>Talanta (Oxford), 2024-06, Vol.273, p.125812-125812, Article 125812</ispartof><rights>2024 The Authors</rights><rights>Copyright © 2024 The Authors. Published by Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c313t-cc7135f6c0df3e924aaab54bf7148da4a8a9fef0fdec7840f56b1350863f3df33</cites><orcidid>0009-0000-4657-0074</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0039914024001917$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38452589$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Liu, Zihan</creatorcontrib><creatorcontrib>Zhao, Xu</creatorcontrib><creatorcontrib>Liu, Yahui</creatorcontrib><creatorcontrib>Shi, Lianhua</creatorcontrib><creatorcontrib>Wu, Liqing</creatorcontrib><creatorcontrib>Yuan, Hui</creatorcontrib><creatorcontrib>Jin, Youxun</creatorcontrib><title>Development of an insulin-like growth factor-1 certified reference material by SI-traceable isotope-dilution mass spectrometry</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>In this study, an insulin-like growth factor-1 (IGF-1) certified reference material (CRM) was developed by the National Institute of Metrology (NIM), and two different principles for evaluating the IGF-1 CRM were established. After optimisation of the acid hydrolysis conditions (110 °C, 36 h), quantitative determination of peptide purity, and chromatographic separation and mass spectrometric detection, amino acid analysis-based high-performance liquid chromatography combined with isotope-dilution tandem mass spectrometry (AAA-HPLC-IDMS/MS) and peptide analysis-based HPLC-IDMS/MS (Peptide-HPLC-IDMS/MS) were used for certified value assignment; the results obtained were 136.28 and 135.01 μg/g, respectively, which were in good agreement. These results were subjected to the normal distribution test, outlier test, and method consistency test. The homogeneity and stability of the reference materials were also examined, and the uncertainty introduced in the experimental process was calculated. The final certified value was (136 ± 15) μg g−1 (k = 2). The CRM was found to be stable for at least six months when stored at −70 °C and for 7 d when stored at higher temperatures (−20 °C, 4 °C, 25 °C, or 40 °C). The CRM is expected to be used as a primary calibrator for quality control in biopharmaceutical production and clinical diagnostics. [Display omitted] •IGF-1 CRM was developed by the National Institute of Metrology (NIM).•AAA-HPLC-IDMS/MS and Peptide-HPLC-IDMS/MS used to evaluate IGF-1 CRM.•CRM was stable for at least 6 months at −70 °C and for 7 d at higher temperatures.</description><subject>AAA-HPLC-IDMS/MS</subject><subject>IGF-1 CRM</subject><subject>LC-MS</subject><subject>Peptide-HPLC-IDMS/MS</subject><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNqFkE2PFCEQQInRuOPqT9Bw9MIIDfTHyZj1a5NNPKhnUk0Xykg3LdBr5uJvl8mMXj3V5b2q1CPkueB7wUX76rAvEGApsG94o_ai0b1oHpCd6DvJpO7kQ7LjXA5sEIpfkSc5HzjnjeTyMbmSvdJVGHbk91u8xxDXGZdCo6OwUL_kLfiFBf8D6bcUf5Xv1IEtMTFBLabinceJJnSYcLFIZyiYPAQ6HunnW1YSWIQxIPU5lrgim3zYio9LJXOmeUVbUpyxpONT8shByPjsMq_J1_fvvtx8ZHefPtzevLljVgpZmLWdkNq1lk9O4tAoABi1Gl0nVD-Bgh4Gh467CW3XK-50O1aB9610sirymrw8711T_LlhLmb22WKoBTFu2TSDVl07dLqtqD6jNsWc65dmTX6GdDSCm1N6czCX9OaU3pzTV-_F5cQ2zjj9s_62rsDrM4D10XuPyWTrTwEnn2oRM0X_nxN_AL0amuA</recordid><startdate>20240601</startdate><enddate>20240601</enddate><creator>Liu, Zihan</creator><creator>Zhao, Xu</creator><creator>Liu, Yahui</creator><creator>Shi, Lianhua</creator><creator>Wu, Liqing</creator><creator>Yuan, Hui</creator><creator>Jin, Youxun</creator><general>Elsevier B.V</general><scope>6I.</scope><scope>AAFTH</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0009-0000-4657-0074</orcidid></search><sort><creationdate>20240601</creationdate><title>Development of an insulin-like growth factor-1 certified reference material by SI-traceable isotope-dilution mass spectrometry</title><author>Liu, Zihan ; Zhao, Xu ; Liu, Yahui ; Shi, Lianhua ; Wu, Liqing ; Yuan, Hui ; Jin, Youxun</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c313t-cc7135f6c0df3e924aaab54bf7148da4a8a9fef0fdec7840f56b1350863f3df33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>AAA-HPLC-IDMS/MS</topic><topic>IGF-1 CRM</topic><topic>LC-MS</topic><topic>Peptide-HPLC-IDMS/MS</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Liu, Zihan</creatorcontrib><creatorcontrib>Zhao, Xu</creatorcontrib><creatorcontrib>Liu, Yahui</creatorcontrib><creatorcontrib>Shi, Lianhua</creatorcontrib><creatorcontrib>Wu, Liqing</creatorcontrib><creatorcontrib>Yuan, Hui</creatorcontrib><creatorcontrib>Jin, Youxun</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Liu, Zihan</au><au>Zhao, Xu</au><au>Liu, Yahui</au><au>Shi, Lianhua</au><au>Wu, Liqing</au><au>Yuan, Hui</au><au>Jin, Youxun</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of an insulin-like growth factor-1 certified reference material by SI-traceable isotope-dilution mass spectrometry</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>2024-06-01</date><risdate>2024</risdate><volume>273</volume><spage>125812</spage><epage>125812</epage><pages>125812-125812</pages><artnum>125812</artnum><issn>0039-9140</issn><eissn>1873-3573</eissn><abstract>In this study, an insulin-like growth factor-1 (IGF-1) certified reference material (CRM) was developed by the National Institute of Metrology (NIM), and two different principles for evaluating the IGF-1 CRM were established. After optimisation of the acid hydrolysis conditions (110 °C, 36 h), quantitative determination of peptide purity, and chromatographic separation and mass spectrometric detection, amino acid analysis-based high-performance liquid chromatography combined with isotope-dilution tandem mass spectrometry (AAA-HPLC-IDMS/MS) and peptide analysis-based HPLC-IDMS/MS (Peptide-HPLC-IDMS/MS) were used for certified value assignment; the results obtained were 136.28 and 135.01 μg/g, respectively, which were in good agreement. These results were subjected to the normal distribution test, outlier test, and method consistency test. The homogeneity and stability of the reference materials were also examined, and the uncertainty introduced in the experimental process was calculated. The final certified value was (136 ± 15) μg g−1 (k = 2). The CRM was found to be stable for at least six months when stored at −70 °C and for 7 d when stored at higher temperatures (−20 °C, 4 °C, 25 °C, or 40 °C). The CRM is expected to be used as a primary calibrator for quality control in biopharmaceutical production and clinical diagnostics. [Display omitted] •IGF-1 CRM was developed by the National Institute of Metrology (NIM).•AAA-HPLC-IDMS/MS and Peptide-HPLC-IDMS/MS used to evaluate IGF-1 CRM.•CRM was stable for at least 6 months at −70 °C and for 7 d at higher temperatures.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>38452589</pmid><doi>10.1016/j.talanta.2024.125812</doi><tpages>1</tpages><orcidid>https://orcid.org/0009-0000-4657-0074</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0039-9140
ispartof Talanta (Oxford), 2024-06, Vol.273, p.125812-125812, Article 125812
issn 0039-9140
1873-3573
language eng
recordid cdi_proquest_miscellaneous_2954769756
source Elsevier ScienceDirect Journals
subjects AAA-HPLC-IDMS/MS
IGF-1 CRM
LC-MS
Peptide-HPLC-IDMS/MS
title Development of an insulin-like growth factor-1 certified reference material by SI-traceable isotope-dilution mass spectrometry
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T05%3A43%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20an%20insulin-like%20growth%20factor-1%20certified%20reference%20material%20by%20SI-traceable%20isotope-dilution%20mass%20spectrometry&rft.jtitle=Talanta%20(Oxford)&rft.au=Liu,%20Zihan&rft.date=2024-06-01&rft.volume=273&rft.spage=125812&rft.epage=125812&rft.pages=125812-125812&rft.artnum=125812&rft.issn=0039-9140&rft.eissn=1873-3573&rft_id=info:doi/10.1016/j.talanta.2024.125812&rft_dat=%3Cproquest_cross%3E2954769756%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2954769756&rft_id=info:pmid/38452589&rft_els_id=S0039914024001917&rfr_iscdi=true