Good Laboratory Practice (GLP) - guidelines for the acquisition and processing of electronic raw data in a GLP environment

The aim of the present document is to provide guidance on the Good Laboratory Practice (GLP)‐compliant acquisition and processing of electronic raw data. The life cycle of electronic raw data and their related meta data from the data acquisition to the data processing and the generation of results i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The quality assurance journal 2006-03, Vol.10 (1), p.3-14
Hauptverfasser: Hassler, Stephan, Donzé, Gérard, Esch, Peter M., Eschbach, Bruno, Hartmann, Hansruedi, Hutter, Leo, Timm, Uwe, Saxer, Hans Peter
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 14
container_issue 1
container_start_page 3
container_title The quality assurance journal
container_volume 10
creator Hassler, Stephan
Donzé, Gérard
Esch, Peter M.
Eschbach, Bruno
Hartmann, Hansruedi
Hutter, Leo
Timm, Uwe
Saxer, Hans Peter
description The aim of the present document is to provide guidance on the Good Laboratory Practice (GLP)‐compliant acquisition and processing of electronic raw data. The life cycle of electronic raw data and their related meta data from the data acquisition to the data processing and the generation of results is shown. The different roles and responsibilities for data entry, data editing, data approval, and data freezing are specified. The requirements for time stamps, audit trails, and the identification of acting persons are described. Furthermore different levels of laboratory instrument integration in a LIMS are discussed. This document is intended to aid test facilities, and to promote the use of a common standard, but it should not be considered as a legally binding document. These guidelines may evolve with experience over the next few years and may be modified to reflect interpretations made by other Organisation for Economic Co‐operation and Development (OECD) member countries. The present guidelines were prepared by the Working Group on Information Technology (Arbeitsgruppe Informationstechnologie, AGIT). This group consists of representatives from Swiss industry and the Swiss GLP monitoring authorities. Copyright © 2006 John Wiley & Sons, Ltd.
doi_str_mv 10.1002/qaj.356
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_29537127</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>29537127</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2456-9d0ae38f3eedbd754b8d4768eb2d440a0b2ecc6957b0fbf6ac9d03d1ede7431d3</originalsourceid><addsrcrecordid>eNp10EtPwzAMB_AKgcRTfAWfeAgV0qZt2iMaMEATb8YxShMXAl2zJRkwPj1BRdw42ZJ_tqx_FG0n5DAhJD2aiddDmhdL0VpCqipOWFks__Qli0vKytVo3blXQoKtqrXoa2iMgpGojRXe2AXcWCG9lgh7w9HNPsTwPNcKW92hg8ZY8C8IQs7m2mmvTQeiUzC1RqJzunsG0wC2KL01nZZgxQco4QXoACEcBOzedZhNsPOb0UojWodbv3Ujejw7fRicx6Pr4cXgeBTLNMuLuFJEIC0biqhqxfKsLlXGihLrVGUZEaROUcqiyllNmrophAwbVCWokGU0UXQj2unvhjdnc3SeT7ST2LaiQzN3PK1yypKUBbjbQ2mNcxYbPrV6IuyCJ4T_ZMtDtjxkG-RBLz90i4v_GL89vux13GvtPH7-aWHfeMEoy_nT1ZCPx_f53eBkzO_oN64Oix8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>29537127</pqid></control><display><type>article</type><title>Good Laboratory Practice (GLP) - guidelines for the acquisition and processing of electronic raw data in a GLP environment</title><source>Wiley Online Library Journals Frontfile Complete</source><creator>Hassler, Stephan ; Donzé, Gérard ; Esch, Peter M. ; Eschbach, Bruno ; Hartmann, Hansruedi ; Hutter, Leo ; Timm, Uwe ; Saxer, Hans Peter</creator><creatorcontrib>Hassler, Stephan ; Donzé, Gérard ; Esch, Peter M. ; Eschbach, Bruno ; Hartmann, Hansruedi ; Hutter, Leo ; Timm, Uwe ; Saxer, Hans Peter</creatorcontrib><description>The aim of the present document is to provide guidance on the Good Laboratory Practice (GLP)‐compliant acquisition and processing of electronic raw data. The life cycle of electronic raw data and their related meta data from the data acquisition to the data processing and the generation of results is shown. The different roles and responsibilities for data entry, data editing, data approval, and data freezing are specified. The requirements for time stamps, audit trails, and the identification of acting persons are described. Furthermore different levels of laboratory instrument integration in a LIMS are discussed. This document is intended to aid test facilities, and to promote the use of a common standard, but it should not be considered as a legally binding document. These guidelines may evolve with experience over the next few years and may be modified to reflect interpretations made by other Organisation for Economic Co‐operation and Development (OECD) member countries. The present guidelines were prepared by the Working Group on Information Technology (Arbeitsgruppe Informationstechnologie, AGIT). This group consists of representatives from Swiss industry and the Swiss GLP monitoring authorities. Copyright © 2006 John Wiley &amp; Sons, Ltd.</description><identifier>ISSN: 1087-8378</identifier><identifier>EISSN: 1099-1786</identifier><identifier>DOI: 10.1002/qaj.356</identifier><language>eng</language><publisher>Chichester, UK: John Wiley &amp; Sons, Ltd</publisher><subject>acquisition and processing ; data approval ; electronic raw data ; Good Laboratory Practice (GLP) ; initialling</subject><ispartof>The quality assurance journal, 2006-03, Vol.10 (1), p.3-14</ispartof><rights>Copyright © 2006 John Wiley &amp; Sons, Ltd.</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2456-9d0ae38f3eedbd754b8d4768eb2d440a0b2ecc6957b0fbf6ac9d03d1ede7431d3</citedby><cites>FETCH-LOGICAL-c2456-9d0ae38f3eedbd754b8d4768eb2d440a0b2ecc6957b0fbf6ac9d03d1ede7431d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fqaj.356$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fqaj.356$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27901,27902,45550,45551</link.rule.ids></links><search><creatorcontrib>Hassler, Stephan</creatorcontrib><creatorcontrib>Donzé, Gérard</creatorcontrib><creatorcontrib>Esch, Peter M.</creatorcontrib><creatorcontrib>Eschbach, Bruno</creatorcontrib><creatorcontrib>Hartmann, Hansruedi</creatorcontrib><creatorcontrib>Hutter, Leo</creatorcontrib><creatorcontrib>Timm, Uwe</creatorcontrib><creatorcontrib>Saxer, Hans Peter</creatorcontrib><title>Good Laboratory Practice (GLP) - guidelines for the acquisition and processing of electronic raw data in a GLP environment</title><title>The quality assurance journal</title><addtitle>Qual. Assur. J</addtitle><description>The aim of the present document is to provide guidance on the Good Laboratory Practice (GLP)‐compliant acquisition and processing of electronic raw data. The life cycle of electronic raw data and their related meta data from the data acquisition to the data processing and the generation of results is shown. The different roles and responsibilities for data entry, data editing, data approval, and data freezing are specified. The requirements for time stamps, audit trails, and the identification of acting persons are described. Furthermore different levels of laboratory instrument integration in a LIMS are discussed. This document is intended to aid test facilities, and to promote the use of a common standard, but it should not be considered as a legally binding document. These guidelines may evolve with experience over the next few years and may be modified to reflect interpretations made by other Organisation for Economic Co‐operation and Development (OECD) member countries. The present guidelines were prepared by the Working Group on Information Technology (Arbeitsgruppe Informationstechnologie, AGIT). This group consists of representatives from Swiss industry and the Swiss GLP monitoring authorities. Copyright © 2006 John Wiley &amp; Sons, Ltd.</description><subject>acquisition and processing</subject><subject>data approval</subject><subject>electronic raw data</subject><subject>Good Laboratory Practice (GLP)</subject><subject>initialling</subject><issn>1087-8378</issn><issn>1099-1786</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNp10EtPwzAMB_AKgcRTfAWfeAgV0qZt2iMaMEATb8YxShMXAl2zJRkwPj1BRdw42ZJ_tqx_FG0n5DAhJD2aiddDmhdL0VpCqipOWFks__Qli0vKytVo3blXQoKtqrXoa2iMgpGojRXe2AXcWCG9lgh7w9HNPsTwPNcKW92hg8ZY8C8IQs7m2mmvTQeiUzC1RqJzunsG0wC2KL01nZZgxQco4QXoACEcBOzedZhNsPOb0UojWodbv3Ujejw7fRicx6Pr4cXgeBTLNMuLuFJEIC0biqhqxfKsLlXGihLrVGUZEaROUcqiyllNmrophAwbVCWokGU0UXQj2unvhjdnc3SeT7ST2LaiQzN3PK1yypKUBbjbQ2mNcxYbPrV6IuyCJ4T_ZMtDtjxkG-RBLz90i4v_GL89vux13GvtPH7-aWHfeMEoy_nT1ZCPx_f53eBkzO_oN64Oix8</recordid><startdate>200603</startdate><enddate>200603</enddate><creator>Hassler, Stephan</creator><creator>Donzé, Gérard</creator><creator>Esch, Peter M.</creator><creator>Eschbach, Bruno</creator><creator>Hartmann, Hansruedi</creator><creator>Hutter, Leo</creator><creator>Timm, Uwe</creator><creator>Saxer, Hans Peter</creator><general>John Wiley &amp; Sons, Ltd</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TA</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>JG9</scope></search><sort><creationdate>200603</creationdate><title>Good Laboratory Practice (GLP) - guidelines for the acquisition and processing of electronic raw data in a GLP environment</title><author>Hassler, Stephan ; Donzé, Gérard ; Esch, Peter M. ; Eschbach, Bruno ; Hartmann, Hansruedi ; Hutter, Leo ; Timm, Uwe ; Saxer, Hans Peter</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2456-9d0ae38f3eedbd754b8d4768eb2d440a0b2ecc6957b0fbf6ac9d03d1ede7431d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>acquisition and processing</topic><topic>data approval</topic><topic>electronic raw data</topic><topic>Good Laboratory Practice (GLP)</topic><topic>initialling</topic><toplevel>online_resources</toplevel><creatorcontrib>Hassler, Stephan</creatorcontrib><creatorcontrib>Donzé, Gérard</creatorcontrib><creatorcontrib>Esch, Peter M.</creatorcontrib><creatorcontrib>Eschbach, Bruno</creatorcontrib><creatorcontrib>Hartmann, Hansruedi</creatorcontrib><creatorcontrib>Hutter, Leo</creatorcontrib><creatorcontrib>Timm, Uwe</creatorcontrib><creatorcontrib>Saxer, Hans Peter</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><collection>Materials Business File</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Materials Research Database</collection><jtitle>The quality assurance journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hassler, Stephan</au><au>Donzé, Gérard</au><au>Esch, Peter M.</au><au>Eschbach, Bruno</au><au>Hartmann, Hansruedi</au><au>Hutter, Leo</au><au>Timm, Uwe</au><au>Saxer, Hans Peter</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Good Laboratory Practice (GLP) - guidelines for the acquisition and processing of electronic raw data in a GLP environment</atitle><jtitle>The quality assurance journal</jtitle><addtitle>Qual. Assur. J</addtitle><date>2006-03</date><risdate>2006</risdate><volume>10</volume><issue>1</issue><spage>3</spage><epage>14</epage><pages>3-14</pages><issn>1087-8378</issn><eissn>1099-1786</eissn><abstract>The aim of the present document is to provide guidance on the Good Laboratory Practice (GLP)‐compliant acquisition and processing of electronic raw data. The life cycle of electronic raw data and their related meta data from the data acquisition to the data processing and the generation of results is shown. The different roles and responsibilities for data entry, data editing, data approval, and data freezing are specified. The requirements for time stamps, audit trails, and the identification of acting persons are described. Furthermore different levels of laboratory instrument integration in a LIMS are discussed. This document is intended to aid test facilities, and to promote the use of a common standard, but it should not be considered as a legally binding document. These guidelines may evolve with experience over the next few years and may be modified to reflect interpretations made by other Organisation for Economic Co‐operation and Development (OECD) member countries. The present guidelines were prepared by the Working Group on Information Technology (Arbeitsgruppe Informationstechnologie, AGIT). This group consists of representatives from Swiss industry and the Swiss GLP monitoring authorities. Copyright © 2006 John Wiley &amp; Sons, Ltd.</abstract><cop>Chichester, UK</cop><pub>John Wiley &amp; Sons, Ltd</pub><doi>10.1002/qaj.356</doi><tpages>12</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1087-8378
ispartof The quality assurance journal, 2006-03, Vol.10 (1), p.3-14
issn 1087-8378
1099-1786
language eng
recordid cdi_proquest_miscellaneous_29537127
source Wiley Online Library Journals Frontfile Complete
subjects acquisition and processing
data approval
electronic raw data
Good Laboratory Practice (GLP)
initialling
title Good Laboratory Practice (GLP) - guidelines for the acquisition and processing of electronic raw data in a GLP environment
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T10%3A46%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Good%20Laboratory%20Practice%20(GLP)%20-%20guidelines%20for%20the%20acquisition%20and%20processing%20of%20electronic%20raw%20data%20in%20a%20GLP%20environment&rft.jtitle=The%20quality%20assurance%20journal&rft.au=Hassler,%20Stephan&rft.date=2006-03&rft.volume=10&rft.issue=1&rft.spage=3&rft.epage=14&rft.pages=3-14&rft.issn=1087-8378&rft.eissn=1099-1786&rft_id=info:doi/10.1002/qaj.356&rft_dat=%3Cproquest_cross%3E29537127%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=29537127&rft_id=info:pmid/&rfr_iscdi=true