Application of the fibre-optic Sagnac interferometer in the investigation of seismic rotational waves
This paper presents new results connected with the fibre-optic Sagnac interferometer application in the investigation of seismic rotational waves. In general, it is a fibre-optic rotational seismometer representing sensitivity equal to 4.27 X 10-8 rad s-1 which can detect seismic rotational waves in...
Gespeichert in:
Veröffentlicht in: | Measurement science & technology 2006-05, Vol.17 (5), p.1186-1193 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1193 |
---|---|
container_issue | 5 |
container_start_page | 1186 |
container_title | Measurement science & technology |
container_volume | 17 |
creator | Jaroszewicz, L R Krajewski, Z Solarz, L Teisseyer, R |
description | This paper presents new results connected with the fibre-optic Sagnac interferometer application in the investigation of seismic rotational waves. In general, it is a fibre-optic rotational seismometer representing sensitivity equal to 4.27 X 10-8 rad s-1 which can detect seismic rotational waves in a direct way. This paper presents the experimental results obtained simultaneously by a fibre-optic and a standard rotational seismometer installed in the Ojcow seismic observatory. The main advantage of such an approach is the possibility of recognizing the velocity of seismic rotational waves, which is different from the velocities of other seismic waves. The experimental data presented in this paper are confirmed by the theoretical description of the nature of seismic rotational waves. |
doi_str_mv | 10.1088/0957-0233/17/5/S42 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_29484304</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>29484304</sourcerecordid><originalsourceid>FETCH-LOGICAL-c350t-b6f575ed5e9dbd459aaf0ff8aa9a7405c5860c9b896ca04d06bac2701e7ef4ac3</originalsourceid><addsrcrecordid>eNp90E1LwzAYB_AgCs7pF_DUk-Ch9knbNM1xDN9g4GF6Dk_TZEa6piad4rc322SXgae88Ps_PPwJuaZwR6GuMxCMp5AXRUZ5xrJlmZ-QCS0qmlYM6CmZHMA5uQjhAwA4CDEhejYMnVU4WtcnziTju06MbbxO3TBalSxx1aNKbD9qb7R3ax0v8bmDtv_SYbSrQzpoG9Yx5d24-8Mu-cZoLsmZwS7oq79zSt4e7l_nT-ni5fF5PlukqmAwpk1lGGe6ZVq0TVsygWjAmBpRIC-BKVZXoERTi0ohlC1UDaqcA9VcmxJVMSU3-7mDd5-buJtc26B012Gv3SbIXJR1WUAZYb6HyrsQvDZy8HaN_kdSkNtG5bYwuS1MUi6ZjI3G0O0-ZN1w8MdODq2JNj22_8z-BcPyhrs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>29484304</pqid></control><display><type>article</type><title>Application of the fibre-optic Sagnac interferometer in the investigation of seismic rotational waves</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Jaroszewicz, L R ; Krajewski, Z ; Solarz, L ; Teisseyer, R</creator><creatorcontrib>Jaroszewicz, L R ; Krajewski, Z ; Solarz, L ; Teisseyer, R</creatorcontrib><description>This paper presents new results connected with the fibre-optic Sagnac interferometer application in the investigation of seismic rotational waves. In general, it is a fibre-optic rotational seismometer representing sensitivity equal to 4.27 X 10-8 rad s-1 which can detect seismic rotational waves in a direct way. This paper presents the experimental results obtained simultaneously by a fibre-optic and a standard rotational seismometer installed in the Ojcow seismic observatory. The main advantage of such an approach is the possibility of recognizing the velocity of seismic rotational waves, which is different from the velocities of other seismic waves. The experimental data presented in this paper are confirmed by the theoretical description of the nature of seismic rotational waves.</description><identifier>ISSN: 0957-0233</identifier><identifier>EISSN: 1361-6501</identifier><identifier>DOI: 10.1088/0957-0233/17/5/S42</identifier><language>eng</language><publisher>IOP Publishing</publisher><ispartof>Measurement science & technology, 2006-05, Vol.17 (5), p.1186-1193</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c350t-b6f575ed5e9dbd459aaf0ff8aa9a7405c5860c9b896ca04d06bac2701e7ef4ac3</citedby><cites>FETCH-LOGICAL-c350t-b6f575ed5e9dbd459aaf0ff8aa9a7405c5860c9b896ca04d06bac2701e7ef4ac3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/0957-0233/17/5/S42/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,776,780,27901,27902,53805,53885</link.rule.ids></links><search><creatorcontrib>Jaroszewicz, L R</creatorcontrib><creatorcontrib>Krajewski, Z</creatorcontrib><creatorcontrib>Solarz, L</creatorcontrib><creatorcontrib>Teisseyer, R</creatorcontrib><title>Application of the fibre-optic Sagnac interferometer in the investigation of seismic rotational waves</title><title>Measurement science & technology</title><description>This paper presents new results connected with the fibre-optic Sagnac interferometer application in the investigation of seismic rotational waves. In general, it is a fibre-optic rotational seismometer representing sensitivity equal to 4.27 X 10-8 rad s-1 which can detect seismic rotational waves in a direct way. This paper presents the experimental results obtained simultaneously by a fibre-optic and a standard rotational seismometer installed in the Ojcow seismic observatory. The main advantage of such an approach is the possibility of recognizing the velocity of seismic rotational waves, which is different from the velocities of other seismic waves. The experimental data presented in this paper are confirmed by the theoretical description of the nature of seismic rotational waves.</description><issn>0957-0233</issn><issn>1361-6501</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNp90E1LwzAYB_AgCs7pF_DUk-Ch9knbNM1xDN9g4GF6Dk_TZEa6piad4rc322SXgae88Ps_PPwJuaZwR6GuMxCMp5AXRUZ5xrJlmZ-QCS0qmlYM6CmZHMA5uQjhAwA4CDEhejYMnVU4WtcnziTju06MbbxO3TBalSxx1aNKbD9qb7R3ax0v8bmDtv_SYbSrQzpoG9Yx5d24-8Mu-cZoLsmZwS7oq79zSt4e7l_nT-ni5fF5PlukqmAwpk1lGGe6ZVq0TVsygWjAmBpRIC-BKVZXoERTi0ohlC1UDaqcA9VcmxJVMSU3-7mDd5-buJtc26B012Gv3SbIXJR1WUAZYb6HyrsQvDZy8HaN_kdSkNtG5bYwuS1MUi6ZjI3G0O0-ZN1w8MdODq2JNj22_8z-BcPyhrs</recordid><startdate>20060501</startdate><enddate>20060501</enddate><creator>Jaroszewicz, L R</creator><creator>Krajewski, Z</creator><creator>Solarz, L</creator><creator>Teisseyer, R</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SM</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>20060501</creationdate><title>Application of the fibre-optic Sagnac interferometer in the investigation of seismic rotational waves</title><author>Jaroszewicz, L R ; Krajewski, Z ; Solarz, L ; Teisseyer, R</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c350t-b6f575ed5e9dbd459aaf0ff8aa9a7405c5860c9b896ca04d06bac2701e7ef4ac3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jaroszewicz, L R</creatorcontrib><creatorcontrib>Krajewski, Z</creatorcontrib><creatorcontrib>Solarz, L</creatorcontrib><creatorcontrib>Teisseyer, R</creatorcontrib><collection>CrossRef</collection><collection>Earthquake Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Measurement science & technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jaroszewicz, L R</au><au>Krajewski, Z</au><au>Solarz, L</au><au>Teisseyer, R</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Application of the fibre-optic Sagnac interferometer in the investigation of seismic rotational waves</atitle><jtitle>Measurement science & technology</jtitle><date>2006-05-01</date><risdate>2006</risdate><volume>17</volume><issue>5</issue><spage>1186</spage><epage>1193</epage><pages>1186-1193</pages><issn>0957-0233</issn><eissn>1361-6501</eissn><abstract>This paper presents new results connected with the fibre-optic Sagnac interferometer application in the investigation of seismic rotational waves. In general, it is a fibre-optic rotational seismometer representing sensitivity equal to 4.27 X 10-8 rad s-1 which can detect seismic rotational waves in a direct way. This paper presents the experimental results obtained simultaneously by a fibre-optic and a standard rotational seismometer installed in the Ojcow seismic observatory. The main advantage of such an approach is the possibility of recognizing the velocity of seismic rotational waves, which is different from the velocities of other seismic waves. The experimental data presented in this paper are confirmed by the theoretical description of the nature of seismic rotational waves.</abstract><pub>IOP Publishing</pub><doi>10.1088/0957-0233/17/5/S42</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0957-0233 |
ispartof | Measurement science & technology, 2006-05, Vol.17 (5), p.1186-1193 |
issn | 0957-0233 1361-6501 |
language | eng |
recordid | cdi_proquest_miscellaneous_29484304 |
source | IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link |
title | Application of the fibre-optic Sagnac interferometer in the investigation of seismic rotational waves |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T22%3A07%3A20IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Application%20of%20the%20fibre-optic%20Sagnac%20interferometer%20in%20the%20investigation%20of%20seismic%20rotational%20waves&rft.jtitle=Measurement%20science%20&%20technology&rft.au=Jaroszewicz,%20L%20R&rft.date=2006-05-01&rft.volume=17&rft.issue=5&rft.spage=1186&rft.epage=1193&rft.pages=1186-1193&rft.issn=0957-0233&rft.eissn=1361-6501&rft_id=info:doi/10.1088/0957-0233/17/5/S42&rft_dat=%3Cproquest_cross%3E29484304%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=29484304&rft_id=info:pmid/&rfr_iscdi=true |