Natural convection in enclosures with floor cooling subjected to a heated vertical wall

Natural convection in enclosures is extensively investigated due to its importance in many applications, such as heat transfer through double glazing windows, electronic cooling devices, geophysical applications, etc. Two configurations that have been extensively explored in the literature are the d...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of heat and mass transfer 2006, Vol.49 (1), p.108-121
Hauptverfasser: Mohamad, A.A., Sicard, J., Bennacer, R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 121
container_issue 1
container_start_page 108
container_title International journal of heat and mass transfer
container_volume 49
creator Mohamad, A.A.
Sicard, J.
Bennacer, R.
description Natural convection in enclosures is extensively investigated due to its importance in many applications, such as heat transfer through double glazing windows, electronic cooling devices, geophysical applications, etc. Two configurations that have been extensively explored in the literature are the differentially heated enclosures and the Rayleigh–Benard problems. In the present work, a different kind of problem is investigated, namely the cross thermal boundary conditions. Three dimensional analyses were performed for an enclosure cooled from below with one vertical wall heated, and the other connecting walls were assumed to be adiabatic. The thermal condition at the ceiling is varied from an adiabatic one to a different degree of heating. The objective of this study is to simulate the comfort provided by floor cooling in a room. For comfort requirements, the interest is on determining the rate of heat transfer and the temperature distribution in the room. Also, the results have importance for other cooling applications such as electronic cooling and natural convection in freezers. Furthermore, the problem is academically interesting for understanding the fundamentals of natural convection. Based on the authors’ knowledge, the physics of this problem has not been explored by other people in such a detail. However, the application has been in practice from ancient times. The predicted results are interesting and have practical applications. For a certain configuration, where strong three dimensional recirculations were predicted, the flow is three dimensional, hence the two dimensional assumption is not valid. Also, it is found that the rate of rate transfer from the floor is a weak function of the investigated parameters, such as Rayleigh number.
doi_str_mv 10.1016/j.ijheatmasstransfer.2005.07.033
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_29449250</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0017931005005107</els_id><sourcerecordid>29449250</sourcerecordid><originalsourceid>FETCH-LOGICAL-c403t-99bd87bc7940da52a5c38bdc49680ab07f0e1e0f4b9c71592b6d193ce50d03613</originalsourceid><addsrcrecordid>eNqNkM1u1TAQRq0KpF4K7-BNEZuk4_w53oEqSltVZQNiaTnOpHXkGxePcyveHke3Egs2XXksHX3fzGHsk4BSgOgu5tLNj2jS3hClaBaaMJYVQFuCLKGuT9hO9FIVlejVG7YDELJQtYBT9o5o3r7QdDv2696kNRrPbVgOaJMLC3cLx8X6QGtE4s8uPfLJhxAzE7xbHjitw5xZHHkK3PBtjTwfMCZnc9Sz8f49ezsZT_jh5T1jP6--_ri8Lu6-f7u5_HJX2AbqVCg1jL0crFQNjKatTGvrfhhto7oezAByAhQIUzMoK0WrqqEbhaottjBC3Yn6jH085j7F8HtFSnrvyKL3ZsGwkq5U06iqhQx-PoI2BqKIk36Kbm_iHy1Ab0b1rP83qjejGqTORnPE-UuXoXznlBnr6F-ObIVQcqu6PXKYDz-4nELWZaM4upi16TG415f-Be0Cmjg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>29449250</pqid></control><display><type>article</type><title>Natural convection in enclosures with floor cooling subjected to a heated vertical wall</title><source>Elsevier ScienceDirect Journals</source><creator>Mohamad, A.A. ; Sicard, J. ; Bennacer, R.</creator><creatorcontrib>Mohamad, A.A. ; Sicard, J. ; Bennacer, R.</creatorcontrib><description>Natural convection in enclosures is extensively investigated due to its importance in many applications, such as heat transfer through double glazing windows, electronic cooling devices, geophysical applications, etc. Two configurations that have been extensively explored in the literature are the differentially heated enclosures and the Rayleigh–Benard problems. In the present work, a different kind of problem is investigated, namely the cross thermal boundary conditions. Three dimensional analyses were performed for an enclosure cooled from below with one vertical wall heated, and the other connecting walls were assumed to be adiabatic. The thermal condition at the ceiling is varied from an adiabatic one to a different degree of heating. The objective of this study is to simulate the comfort provided by floor cooling in a room. For comfort requirements, the interest is on determining the rate of heat transfer and the temperature distribution in the room. Also, the results have importance for other cooling applications such as electronic cooling and natural convection in freezers. Furthermore, the problem is academically interesting for understanding the fundamentals of natural convection. Based on the authors’ knowledge, the physics of this problem has not been explored by other people in such a detail. However, the application has been in practice from ancient times. The predicted results are interesting and have practical applications. For a certain configuration, where strong three dimensional recirculations were predicted, the flow is three dimensional, hence the two dimensional assumption is not valid. Also, it is found that the rate of rate transfer from the floor is a weak function of the investigated parameters, such as Rayleigh number.</description><identifier>ISSN: 0017-9310</identifier><identifier>EISSN: 1879-2189</identifier><identifier>DOI: 10.1016/j.ijheatmasstransfer.2005.07.033</identifier><identifier>CODEN: IJHMAK</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Applied sciences ; Building technical equipments ; Buildings ; Buildings. Public works ; Computation methods. Tables. Charts ; Environmental engineering ; Exact sciences and technology ; External envelopes ; Structural analysis. Stresses ; Ventilation. Air conditioning ; Wall. Partition</subject><ispartof>International journal of heat and mass transfer, 2006, Vol.49 (1), p.108-121</ispartof><rights>2005</rights><rights>2006 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c403t-99bd87bc7940da52a5c38bdc49680ab07f0e1e0f4b9c71592b6d193ce50d03613</citedby><cites>FETCH-LOGICAL-c403t-99bd87bc7940da52a5c38bdc49680ab07f0e1e0f4b9c71592b6d193ce50d03613</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0017931005005107$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,4010,27900,27901,27902,65306</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=17511970$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Mohamad, A.A.</creatorcontrib><creatorcontrib>Sicard, J.</creatorcontrib><creatorcontrib>Bennacer, R.</creatorcontrib><title>Natural convection in enclosures with floor cooling subjected to a heated vertical wall</title><title>International journal of heat and mass transfer</title><description>Natural convection in enclosures is extensively investigated due to its importance in many applications, such as heat transfer through double glazing windows, electronic cooling devices, geophysical applications, etc. Two configurations that have been extensively explored in the literature are the differentially heated enclosures and the Rayleigh–Benard problems. In the present work, a different kind of problem is investigated, namely the cross thermal boundary conditions. Three dimensional analyses were performed for an enclosure cooled from below with one vertical wall heated, and the other connecting walls were assumed to be adiabatic. The thermal condition at the ceiling is varied from an adiabatic one to a different degree of heating. The objective of this study is to simulate the comfort provided by floor cooling in a room. For comfort requirements, the interest is on determining the rate of heat transfer and the temperature distribution in the room. Also, the results have importance for other cooling applications such as electronic cooling and natural convection in freezers. Furthermore, the problem is academically interesting for understanding the fundamentals of natural convection. Based on the authors’ knowledge, the physics of this problem has not been explored by other people in such a detail. However, the application has been in practice from ancient times. The predicted results are interesting and have practical applications. For a certain configuration, where strong three dimensional recirculations were predicted, the flow is three dimensional, hence the two dimensional assumption is not valid. Also, it is found that the rate of rate transfer from the floor is a weak function of the investigated parameters, such as Rayleigh number.</description><subject>Applied sciences</subject><subject>Building technical equipments</subject><subject>Buildings</subject><subject>Buildings. Public works</subject><subject>Computation methods. Tables. Charts</subject><subject>Environmental engineering</subject><subject>Exact sciences and technology</subject><subject>External envelopes</subject><subject>Structural analysis. Stresses</subject><subject>Ventilation. Air conditioning</subject><subject>Wall. Partition</subject><issn>0017-9310</issn><issn>1879-2189</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNqNkM1u1TAQRq0KpF4K7-BNEZuk4_w53oEqSltVZQNiaTnOpHXkGxePcyveHke3Egs2XXksHX3fzGHsk4BSgOgu5tLNj2jS3hClaBaaMJYVQFuCLKGuT9hO9FIVlejVG7YDELJQtYBT9o5o3r7QdDv2696kNRrPbVgOaJMLC3cLx8X6QGtE4s8uPfLJhxAzE7xbHjitw5xZHHkK3PBtjTwfMCZnc9Sz8f49ezsZT_jh5T1jP6--_ri8Lu6-f7u5_HJX2AbqVCg1jL0crFQNjKatTGvrfhhto7oezAByAhQIUzMoK0WrqqEbhaottjBC3Yn6jH085j7F8HtFSnrvyKL3ZsGwkq5U06iqhQx-PoI2BqKIk36Kbm_iHy1Ab0b1rP83qjejGqTORnPE-UuXoXznlBnr6F-ObIVQcqu6PXKYDz-4nELWZaM4upi16TG415f-Be0Cmjg</recordid><startdate>2006</startdate><enddate>2006</enddate><creator>Mohamad, A.A.</creator><creator>Sicard, J.</creator><creator>Bennacer, R.</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>H8D</scope><scope>KR7</scope><scope>L7M</scope></search><sort><creationdate>2006</creationdate><title>Natural convection in enclosures with floor cooling subjected to a heated vertical wall</title><author>Mohamad, A.A. ; Sicard, J. ; Bennacer, R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c403t-99bd87bc7940da52a5c38bdc49680ab07f0e1e0f4b9c71592b6d193ce50d03613</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Applied sciences</topic><topic>Building technical equipments</topic><topic>Buildings</topic><topic>Buildings. Public works</topic><topic>Computation methods. Tables. Charts</topic><topic>Environmental engineering</topic><topic>Exact sciences and technology</topic><topic>External envelopes</topic><topic>Structural analysis. Stresses</topic><topic>Ventilation. Air conditioning</topic><topic>Wall. Partition</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mohamad, A.A.</creatorcontrib><creatorcontrib>Sicard, J.</creatorcontrib><creatorcontrib>Bennacer, R.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>International journal of heat and mass transfer</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mohamad, A.A.</au><au>Sicard, J.</au><au>Bennacer, R.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Natural convection in enclosures with floor cooling subjected to a heated vertical wall</atitle><jtitle>International journal of heat and mass transfer</jtitle><date>2006</date><risdate>2006</risdate><volume>49</volume><issue>1</issue><spage>108</spage><epage>121</epage><pages>108-121</pages><issn>0017-9310</issn><eissn>1879-2189</eissn><coden>IJHMAK</coden><abstract>Natural convection in enclosures is extensively investigated due to its importance in many applications, such as heat transfer through double glazing windows, electronic cooling devices, geophysical applications, etc. Two configurations that have been extensively explored in the literature are the differentially heated enclosures and the Rayleigh–Benard problems. In the present work, a different kind of problem is investigated, namely the cross thermal boundary conditions. Three dimensional analyses were performed for an enclosure cooled from below with one vertical wall heated, and the other connecting walls were assumed to be adiabatic. The thermal condition at the ceiling is varied from an adiabatic one to a different degree of heating. The objective of this study is to simulate the comfort provided by floor cooling in a room. For comfort requirements, the interest is on determining the rate of heat transfer and the temperature distribution in the room. Also, the results have importance for other cooling applications such as electronic cooling and natural convection in freezers. Furthermore, the problem is academically interesting for understanding the fundamentals of natural convection. Based on the authors’ knowledge, the physics of this problem has not been explored by other people in such a detail. However, the application has been in practice from ancient times. The predicted results are interesting and have practical applications. For a certain configuration, where strong three dimensional recirculations were predicted, the flow is three dimensional, hence the two dimensional assumption is not valid. Also, it is found that the rate of rate transfer from the floor is a weak function of the investigated parameters, such as Rayleigh number.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.ijheatmasstransfer.2005.07.033</doi><tpages>14</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0017-9310
ispartof International journal of heat and mass transfer, 2006, Vol.49 (1), p.108-121
issn 0017-9310
1879-2189
language eng
recordid cdi_proquest_miscellaneous_29449250
source Elsevier ScienceDirect Journals
subjects Applied sciences
Building technical equipments
Buildings
Buildings. Public works
Computation methods. Tables. Charts
Environmental engineering
Exact sciences and technology
External envelopes
Structural analysis. Stresses
Ventilation. Air conditioning
Wall. Partition
title Natural convection in enclosures with floor cooling subjected to a heated vertical wall
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-29T13%3A09%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Natural%20convection%20in%20enclosures%20with%20floor%20cooling%20subjected%20to%20a%20heated%20vertical%20wall&rft.jtitle=International%20journal%20of%20heat%20and%20mass%20transfer&rft.au=Mohamad,%20A.A.&rft.date=2006&rft.volume=49&rft.issue=1&rft.spage=108&rft.epage=121&rft.pages=108-121&rft.issn=0017-9310&rft.eissn=1879-2189&rft.coden=IJHMAK&rft_id=info:doi/10.1016/j.ijheatmasstransfer.2005.07.033&rft_dat=%3Cproquest_cross%3E29449250%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=29449250&rft_id=info:pmid/&rft_els_id=S0017931005005107&rfr_iscdi=true