Proof-of-principle measurements of the superfluid joule-thomson refrigerator concept

The performance of the first Superfluid Joule-Thomson Refrigerator (SJTR) is described. The SJTR has achieved a low temperature of 0.68 K when exhausting its waste heat to a thermal reservoir at a temperature of 1.2 K Cooling power versus temperature measurements were conducted with two different th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of low temperature physics 2005-11, Vol.141 (3-4), p.179-190
Hauptverfasser: MILLER, F. K, BRISSON, J. G
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 190
container_issue 3-4
container_start_page 179
container_title Journal of low temperature physics
container_volume 141
creator MILLER, F. K
BRISSON, J. G
description The performance of the first Superfluid Joule-Thomson Refrigerator (SJTR) is described. The SJTR has achieved a low temperature of 0.68 K when exhausting its waste heat to a thermal reservoir at a temperature of 1.2 K Cooling power versus temperature measurements were conducted with two different throttles and with different compressor speeds.
doi_str_mv 10.1007/s10909-005-8227-z
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_29300766</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>29300766</sourcerecordid><originalsourceid>FETCH-LOGICAL-c306t-351cbb5e94f5fd5fa247e81bdbafdb117c5d63f2991eb5757964a10265bf4083</originalsourceid><addsrcrecordid>eNpFkEtPwzAQhC0EEqXwA7jlAjfD-hXXR1TxkirBoXfLcdY0VRIHOznQX09QKyGNtJeZ0c5HyC2DBwagHzMDA4YCKLriXNPDGVkwpQXVQulzsgDgnHJu2CW5ynkPAGZVigXZfqYYA501pKb3zdBi0aHLU8IO-zEXMRTjDos8DZhCOzV1sY9Ti3TcxS7HvkgYUvOFyY0xFT72HofxmlwE12a8Od0l2b48b9dvdPPx-r5-2lAvoBypUMxXlUIjgwq1Co5LjStW1ZULdcWY9qouReDGMKyUVtqU0jHgpaqChJVYkvtj7ZDi94R5tF2TPbat6zFO2XIjZjRlORvZ0ehTzHn-2M5jO5d-LAP7h88e8dkZn_3DZw9z5u5U7rJ3bUhuppP_g1pKrqQUv2LAcik</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>29300766</pqid></control><display><type>article</type><title>Proof-of-principle measurements of the superfluid joule-thomson refrigerator concept</title><source>SpringerNature Journals</source><creator>MILLER, F. K ; BRISSON, J. G</creator><creatorcontrib>MILLER, F. K ; BRISSON, J. G</creatorcontrib><description>The performance of the first Superfluid Joule-Thomson Refrigerator (SJTR) is described. The SJTR has achieved a low temperature of 0.68 K when exhausting its waste heat to a thermal reservoir at a temperature of 1.2 K Cooling power versus temperature measurements were conducted with two different throttles and with different compressor speeds.</description><identifier>ISSN: 0022-2291</identifier><identifier>EISSN: 1573-7357</identifier><identifier>DOI: 10.1007/s10909-005-8227-z</identifier><identifier>CODEN: JLTPAC</identifier><language>eng</language><publisher>Heidelberg: Springer</publisher><subject>Applied sciences ; Energy ; Energy. Thermal use of fuels ; Exact sciences and technology ; Refrigerating engineering ; Refrigerating engineering. Cryogenics. Food conservation ; Refrigeration installations</subject><ispartof>Journal of low temperature physics, 2005-11, Vol.141 (3-4), p.179-190</ispartof><rights>2006 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c306t-351cbb5e94f5fd5fa247e81bdbafdb117c5d63f2991eb5757964a10265bf4083</citedby><cites>FETCH-LOGICAL-c306t-351cbb5e94f5fd5fa247e81bdbafdb117c5d63f2991eb5757964a10265bf4083</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,782,786,27933,27934</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=17442544$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>MILLER, F. K</creatorcontrib><creatorcontrib>BRISSON, J. G</creatorcontrib><title>Proof-of-principle measurements of the superfluid joule-thomson refrigerator concept</title><title>Journal of low temperature physics</title><description>The performance of the first Superfluid Joule-Thomson Refrigerator (SJTR) is described. The SJTR has achieved a low temperature of 0.68 K when exhausting its waste heat to a thermal reservoir at a temperature of 1.2 K Cooling power versus temperature measurements were conducted with two different throttles and with different compressor speeds.</description><subject>Applied sciences</subject><subject>Energy</subject><subject>Energy. Thermal use of fuels</subject><subject>Exact sciences and technology</subject><subject>Refrigerating engineering</subject><subject>Refrigerating engineering. Cryogenics. Food conservation</subject><subject>Refrigeration installations</subject><issn>0022-2291</issn><issn>1573-7357</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNpFkEtPwzAQhC0EEqXwA7jlAjfD-hXXR1TxkirBoXfLcdY0VRIHOznQX09QKyGNtJeZ0c5HyC2DBwagHzMDA4YCKLriXNPDGVkwpQXVQulzsgDgnHJu2CW5ynkPAGZVigXZfqYYA501pKb3zdBi0aHLU8IO-zEXMRTjDos8DZhCOzV1sY9Ti3TcxS7HvkgYUvOFyY0xFT72HofxmlwE12a8Od0l2b48b9dvdPPx-r5-2lAvoBypUMxXlUIjgwq1Co5LjStW1ZULdcWY9qouReDGMKyUVtqU0jHgpaqChJVYkvtj7ZDi94R5tF2TPbat6zFO2XIjZjRlORvZ0ehTzHn-2M5jO5d-LAP7h88e8dkZn_3DZw9z5u5U7rJ3bUhuppP_g1pKrqQUv2LAcik</recordid><startdate>20051101</startdate><enddate>20051101</enddate><creator>MILLER, F. K</creator><creator>BRISSON, J. G</creator><general>Springer</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>20051101</creationdate><title>Proof-of-principle measurements of the superfluid joule-thomson refrigerator concept</title><author>MILLER, F. K ; BRISSON, J. G</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c306t-351cbb5e94f5fd5fa247e81bdbafdb117c5d63f2991eb5757964a10265bf4083</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Applied sciences</topic><topic>Energy</topic><topic>Energy. Thermal use of fuels</topic><topic>Exact sciences and technology</topic><topic>Refrigerating engineering</topic><topic>Refrigerating engineering. Cryogenics. Food conservation</topic><topic>Refrigeration installations</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>MILLER, F. K</creatorcontrib><creatorcontrib>BRISSON, J. G</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of low temperature physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>MILLER, F. K</au><au>BRISSON, J. G</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Proof-of-principle measurements of the superfluid joule-thomson refrigerator concept</atitle><jtitle>Journal of low temperature physics</jtitle><date>2005-11-01</date><risdate>2005</risdate><volume>141</volume><issue>3-4</issue><spage>179</spage><epage>190</epage><pages>179-190</pages><issn>0022-2291</issn><eissn>1573-7357</eissn><coden>JLTPAC</coden><abstract>The performance of the first Superfluid Joule-Thomson Refrigerator (SJTR) is described. The SJTR has achieved a low temperature of 0.68 K when exhausting its waste heat to a thermal reservoir at a temperature of 1.2 K Cooling power versus temperature measurements were conducted with two different throttles and with different compressor speeds.</abstract><cop>Heidelberg</cop><pub>Springer</pub><doi>10.1007/s10909-005-8227-z</doi><tpages>12</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0022-2291
ispartof Journal of low temperature physics, 2005-11, Vol.141 (3-4), p.179-190
issn 0022-2291
1573-7357
language eng
recordid cdi_proquest_miscellaneous_29300766
source SpringerNature Journals
subjects Applied sciences
Energy
Energy. Thermal use of fuels
Exact sciences and technology
Refrigerating engineering
Refrigerating engineering. Cryogenics. Food conservation
Refrigeration installations
title Proof-of-principle measurements of the superfluid joule-thomson refrigerator concept
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-02T22%3A29%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Proof-of-principle%20measurements%20of%20the%20superfluid%20joule-thomson%20refrigerator%20concept&rft.jtitle=Journal%20of%20low%20temperature%20physics&rft.au=MILLER,%20F.%20K&rft.date=2005-11-01&rft.volume=141&rft.issue=3-4&rft.spage=179&rft.epage=190&rft.pages=179-190&rft.issn=0022-2291&rft.eissn=1573-7357&rft.coden=JLTPAC&rft_id=info:doi/10.1007/s10909-005-8227-z&rft_dat=%3Cproquest_cross%3E29300766%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=29300766&rft_id=info:pmid/&rfr_iscdi=true