Cementless reverse total shoulder arthroplasty implantation with humeral matchstick autograft augmentation: early radiographic outcomes

Humeral-sided complications account for up to 21% of all revision reverse total shoulder arthroplasty (RTSA) surgeries. Stress shielding with large bulky stems can lead to proximal bone resorption per Wolff law, complicating further surgeries. Previously published studies suggest that lowering the m...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of shoulder and elbow surgery 2024-08, Vol.33 (8), p.e422-e428
Hauptverfasser: Montemaggi, Paolo, Lo, Eddie Y., Ouseph, Alvin, Lund, Julia, Krishnan, Sumant G.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page e428
container_issue 8
container_start_page e422
container_title Journal of shoulder and elbow surgery
container_volume 33
creator Montemaggi, Paolo
Lo, Eddie Y.
Ouseph, Alvin
Lund, Julia
Krishnan, Sumant G.
description Humeral-sided complications account for up to 21% of all revision reverse total shoulder arthroplasty (RTSA) surgeries. Stress shielding with large bulky stems can lead to proximal bone resorption per Wolff law, complicating further surgeries. Previously published studies suggest that lowering the metaphyseal implant fill ratio can lead to fewer adaptive radiographic changes and decreased bone resorption. Inspired by these studies, cementless primary RTSA implantation technique with humeral matchstick autografts was proposed to augment cementless humeral constructs, foster the use of a smaller size stem, and create primary stability of the humeral implant even in osteoporotic or in-between size medullary canals. In this study, retrospective review of this cementless RTSA technique with short-term radiographic evaluation was performed. Forty-six nonconsecutive patients underwent primary RTSA with a short-stem cementless prosthesis (Stryker Ascend Flex) augmented by matchstick bone grafting from January to July 2020. Patient demographics were recorded, and follow-up radiographs were retrospectively reviewed to assess metaphyseal fill ratios and incidence of stress shielding at minimum 1-year follow-up. Discrepancies between templated and final stem sizes were recorded, along with all intraoperative and postoperative complications. Of the 46 patients originally identified, there were 5 men and 41 women with a mean age of 71 years (standard deviation [SD] 7, range 53-88). Mean templated stem size was 4 (SD 2, range 1-8), whereas the mean final implant size was 2 (SD 1, range 1-3). Mean fill ratios were 0.76 (SD 0.06, range 0.54-0.89) along the metaphysis and 0.67 (SD 0.09, range 0.49-0.83) along the diaphysis. There were no intraoperative humeral fractures from implantation. All patients were available for radiographic follow-up with a mean of 19 months (SD 8, range 12-40). There were 3 cases (7%) of proximal humeral stress shielding, with average fill ratios of 0.857 and 0.807 in the metaphysis and diaphysis, respectively. There were 3 patients (7%) who underwent revision surgeries for baseplate failure and periprosthetic humeral fracture. There were no cases of early humeral loosening. Matchstick autograft humeral augmentation is a simple, promising surgical technique with low intraoperative complication rates and good short-term radiographic outcomes. When the implant fill ratio is successfully reduced, there is a possible lower risk of humeral stress shiel
doi_str_mv 10.1016/j.jse.2023.11.021
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2929033769</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1058274624000223</els_id><sourcerecordid>2929033769</sourcerecordid><originalsourceid>FETCH-LOGICAL-c305t-bec96afdd65681b42be9787cadb549a2f491795a56252fb5c0cb447113ebba163</originalsourceid><addsrcrecordid>eNp9kMtO3DAUhq0KVC7tA3SDvGST1JfYicsKjVpaCYkNXVu2c0I8JOOp7YDmCfraeDrAsqvzS-c7v3Q-hL5QUlNC5dd1vU5QM8J4TWlNGP2ATqngrJKCkKOSiegq1jbyBJ2ltCaEqIawj-iEd4x2DeGn6O8KZtjkCVLCEZ4gJsA5ZDPhNIZl6iFiE_MYw3YyKe-wn0vYZJN92OBnn0c8LjPEws8muzFl7x6xWXJ4iGbIJT3s6__h3zCYOO1wNL3fr7ejdzgs2YUZ0id0PJgpwefXeY5-__h-v_pZ3d7d_Fpd31aOE5ErC05JM_S9FLKjtmEWVNu1zvRWNMqwoVG0VcIIyQQbrHDE2aZpKeVgraGSn6PLQ-82hj8LpKxnnxxM5SkIS9JMMUU4b6UqKD2gLoaUIgx6G_1s4k5Tovf-9VoX_3rvX1Oqi_9yc_Fav9gZ-veLN-EFuDoAUJ588hB1ch42DnofwWXdB_-f-hftc5rA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2929033769</pqid></control><display><type>article</type><title>Cementless reverse total shoulder arthroplasty implantation with humeral matchstick autograft augmentation: early radiographic outcomes</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>Montemaggi, Paolo ; Lo, Eddie Y. ; Ouseph, Alvin ; Lund, Julia ; Krishnan, Sumant G.</creator><creatorcontrib>Montemaggi, Paolo ; Lo, Eddie Y. ; Ouseph, Alvin ; Lund, Julia ; Krishnan, Sumant G.</creatorcontrib><description>Humeral-sided complications account for up to 21% of all revision reverse total shoulder arthroplasty (RTSA) surgeries. Stress shielding with large bulky stems can lead to proximal bone resorption per Wolff law, complicating further surgeries. Previously published studies suggest that lowering the metaphyseal implant fill ratio can lead to fewer adaptive radiographic changes and decreased bone resorption. Inspired by these studies, cementless primary RTSA implantation technique with humeral matchstick autografts was proposed to augment cementless humeral constructs, foster the use of a smaller size stem, and create primary stability of the humeral implant even in osteoporotic or in-between size medullary canals. In this study, retrospective review of this cementless RTSA technique with short-term radiographic evaluation was performed. Forty-six nonconsecutive patients underwent primary RTSA with a short-stem cementless prosthesis (Stryker Ascend Flex) augmented by matchstick bone grafting from January to July 2020. Patient demographics were recorded, and follow-up radiographs were retrospectively reviewed to assess metaphyseal fill ratios and incidence of stress shielding at minimum 1-year follow-up. Discrepancies between templated and final stem sizes were recorded, along with all intraoperative and postoperative complications. Of the 46 patients originally identified, there were 5 men and 41 women with a mean age of 71 years (standard deviation [SD] 7, range 53-88). Mean templated stem size was 4 (SD 2, range 1-8), whereas the mean final implant size was 2 (SD 1, range 1-3). Mean fill ratios were 0.76 (SD 0.06, range 0.54-0.89) along the metaphysis and 0.67 (SD 0.09, range 0.49-0.83) along the diaphysis. There were no intraoperative humeral fractures from implantation. All patients were available for radiographic follow-up with a mean of 19 months (SD 8, range 12-40). There were 3 cases (7%) of proximal humeral stress shielding, with average fill ratios of 0.857 and 0.807 in the metaphysis and diaphysis, respectively. There were 3 patients (7%) who underwent revision surgeries for baseplate failure and periprosthetic humeral fracture. There were no cases of early humeral loosening. Matchstick autograft humeral augmentation is a simple, promising surgical technique with low intraoperative complication rates and good short-term radiographic outcomes. When the implant fill ratio is successfully reduced, there is a possible lower risk of humeral stress shielding. The authors believe this technique can help maximize implant stability in cementless shoulder arthroplasty and preserve humeral bone stock for future revision surgeries.</description><identifier>ISSN: 1058-2746</identifier><identifier>ISSN: 1532-6500</identifier><identifier>EISSN: 1532-6500</identifier><identifier>DOI: 10.1016/j.jse.2023.11.021</identifier><identifier>PMID: 38218403</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Cementless reverse total shoulder arthroplasty ; fill ratio ; humeral autograft ; matchstick ; proximal humeral bone loss ; stress shielding</subject><ispartof>Journal of shoulder and elbow surgery, 2024-08, Vol.33 (8), p.e422-e428</ispartof><rights>2024 Journal of Shoulder and Elbow Surgery Board of Trustees</rights><rights>Copyright © 2024 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c305t-bec96afdd65681b42be9787cadb549a2f491795a56252fb5c0cb447113ebba163</cites><orcidid>0000-0001-9828-7174 ; 0000-0003-0865-858X ; 0000-0002-7992-709X ; 0000-0001-5369-5780</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.jse.2023.11.021$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>315,781,785,3551,27929,27930,46000</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38218403$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Montemaggi, Paolo</creatorcontrib><creatorcontrib>Lo, Eddie Y.</creatorcontrib><creatorcontrib>Ouseph, Alvin</creatorcontrib><creatorcontrib>Lund, Julia</creatorcontrib><creatorcontrib>Krishnan, Sumant G.</creatorcontrib><title>Cementless reverse total shoulder arthroplasty implantation with humeral matchstick autograft augmentation: early radiographic outcomes</title><title>Journal of shoulder and elbow surgery</title><addtitle>J Shoulder Elbow Surg</addtitle><description>Humeral-sided complications account for up to 21% of all revision reverse total shoulder arthroplasty (RTSA) surgeries. Stress shielding with large bulky stems can lead to proximal bone resorption per Wolff law, complicating further surgeries. Previously published studies suggest that lowering the metaphyseal implant fill ratio can lead to fewer adaptive radiographic changes and decreased bone resorption. Inspired by these studies, cementless primary RTSA implantation technique with humeral matchstick autografts was proposed to augment cementless humeral constructs, foster the use of a smaller size stem, and create primary stability of the humeral implant even in osteoporotic or in-between size medullary canals. In this study, retrospective review of this cementless RTSA technique with short-term radiographic evaluation was performed. Forty-six nonconsecutive patients underwent primary RTSA with a short-stem cementless prosthesis (Stryker Ascend Flex) augmented by matchstick bone grafting from January to July 2020. Patient demographics were recorded, and follow-up radiographs were retrospectively reviewed to assess metaphyseal fill ratios and incidence of stress shielding at minimum 1-year follow-up. Discrepancies between templated and final stem sizes were recorded, along with all intraoperative and postoperative complications. Of the 46 patients originally identified, there were 5 men and 41 women with a mean age of 71 years (standard deviation [SD] 7, range 53-88). Mean templated stem size was 4 (SD 2, range 1-8), whereas the mean final implant size was 2 (SD 1, range 1-3). Mean fill ratios were 0.76 (SD 0.06, range 0.54-0.89) along the metaphysis and 0.67 (SD 0.09, range 0.49-0.83) along the diaphysis. There were no intraoperative humeral fractures from implantation. All patients were available for radiographic follow-up with a mean of 19 months (SD 8, range 12-40). There were 3 cases (7%) of proximal humeral stress shielding, with average fill ratios of 0.857 and 0.807 in the metaphysis and diaphysis, respectively. There were 3 patients (7%) who underwent revision surgeries for baseplate failure and periprosthetic humeral fracture. There were no cases of early humeral loosening. Matchstick autograft humeral augmentation is a simple, promising surgical technique with low intraoperative complication rates and good short-term radiographic outcomes. When the implant fill ratio is successfully reduced, there is a possible lower risk of humeral stress shielding. The authors believe this technique can help maximize implant stability in cementless shoulder arthroplasty and preserve humeral bone stock for future revision surgeries.</description><subject>Cementless reverse total shoulder arthroplasty</subject><subject>fill ratio</subject><subject>humeral autograft</subject><subject>matchstick</subject><subject>proximal humeral bone loss</subject><subject>stress shielding</subject><issn>1058-2746</issn><issn>1532-6500</issn><issn>1532-6500</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kMtO3DAUhq0KVC7tA3SDvGST1JfYicsKjVpaCYkNXVu2c0I8JOOp7YDmCfraeDrAsqvzS-c7v3Q-hL5QUlNC5dd1vU5QM8J4TWlNGP2ATqngrJKCkKOSiegq1jbyBJ2ltCaEqIawj-iEd4x2DeGn6O8KZtjkCVLCEZ4gJsA5ZDPhNIZl6iFiE_MYw3YyKe-wn0vYZJN92OBnn0c8LjPEws8muzFl7x6xWXJ4iGbIJT3s6__h3zCYOO1wNL3fr7ejdzgs2YUZ0id0PJgpwefXeY5-__h-v_pZ3d7d_Fpd31aOE5ErC05JM_S9FLKjtmEWVNu1zvRWNMqwoVG0VcIIyQQbrHDE2aZpKeVgraGSn6PLQ-82hj8LpKxnnxxM5SkIS9JMMUU4b6UqKD2gLoaUIgx6G_1s4k5Tovf-9VoX_3rvX1Oqi_9yc_Fav9gZ-veLN-EFuDoAUJ588hB1ch42DnofwWXdB_-f-hftc5rA</recordid><startdate>20240801</startdate><enddate>20240801</enddate><creator>Montemaggi, Paolo</creator><creator>Lo, Eddie Y.</creator><creator>Ouseph, Alvin</creator><creator>Lund, Julia</creator><creator>Krishnan, Sumant G.</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-9828-7174</orcidid><orcidid>https://orcid.org/0000-0003-0865-858X</orcidid><orcidid>https://orcid.org/0000-0002-7992-709X</orcidid><orcidid>https://orcid.org/0000-0001-5369-5780</orcidid></search><sort><creationdate>20240801</creationdate><title>Cementless reverse total shoulder arthroplasty implantation with humeral matchstick autograft augmentation: early radiographic outcomes</title><author>Montemaggi, Paolo ; Lo, Eddie Y. ; Ouseph, Alvin ; Lund, Julia ; Krishnan, Sumant G.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c305t-bec96afdd65681b42be9787cadb549a2f491795a56252fb5c0cb447113ebba163</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Cementless reverse total shoulder arthroplasty</topic><topic>fill ratio</topic><topic>humeral autograft</topic><topic>matchstick</topic><topic>proximal humeral bone loss</topic><topic>stress shielding</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Montemaggi, Paolo</creatorcontrib><creatorcontrib>Lo, Eddie Y.</creatorcontrib><creatorcontrib>Ouseph, Alvin</creatorcontrib><creatorcontrib>Lund, Julia</creatorcontrib><creatorcontrib>Krishnan, Sumant G.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of shoulder and elbow surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Montemaggi, Paolo</au><au>Lo, Eddie Y.</au><au>Ouseph, Alvin</au><au>Lund, Julia</au><au>Krishnan, Sumant G.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Cementless reverse total shoulder arthroplasty implantation with humeral matchstick autograft augmentation: early radiographic outcomes</atitle><jtitle>Journal of shoulder and elbow surgery</jtitle><addtitle>J Shoulder Elbow Surg</addtitle><date>2024-08-01</date><risdate>2024</risdate><volume>33</volume><issue>8</issue><spage>e422</spage><epage>e428</epage><pages>e422-e428</pages><issn>1058-2746</issn><issn>1532-6500</issn><eissn>1532-6500</eissn><abstract>Humeral-sided complications account for up to 21% of all revision reverse total shoulder arthroplasty (RTSA) surgeries. Stress shielding with large bulky stems can lead to proximal bone resorption per Wolff law, complicating further surgeries. Previously published studies suggest that lowering the metaphyseal implant fill ratio can lead to fewer adaptive radiographic changes and decreased bone resorption. Inspired by these studies, cementless primary RTSA implantation technique with humeral matchstick autografts was proposed to augment cementless humeral constructs, foster the use of a smaller size stem, and create primary stability of the humeral implant even in osteoporotic or in-between size medullary canals. In this study, retrospective review of this cementless RTSA technique with short-term radiographic evaluation was performed. Forty-six nonconsecutive patients underwent primary RTSA with a short-stem cementless prosthesis (Stryker Ascend Flex) augmented by matchstick bone grafting from January to July 2020. Patient demographics were recorded, and follow-up radiographs were retrospectively reviewed to assess metaphyseal fill ratios and incidence of stress shielding at minimum 1-year follow-up. Discrepancies between templated and final stem sizes were recorded, along with all intraoperative and postoperative complications. Of the 46 patients originally identified, there were 5 men and 41 women with a mean age of 71 years (standard deviation [SD] 7, range 53-88). Mean templated stem size was 4 (SD 2, range 1-8), whereas the mean final implant size was 2 (SD 1, range 1-3). Mean fill ratios were 0.76 (SD 0.06, range 0.54-0.89) along the metaphysis and 0.67 (SD 0.09, range 0.49-0.83) along the diaphysis. There were no intraoperative humeral fractures from implantation. All patients were available for radiographic follow-up with a mean of 19 months (SD 8, range 12-40). There were 3 cases (7%) of proximal humeral stress shielding, with average fill ratios of 0.857 and 0.807 in the metaphysis and diaphysis, respectively. There were 3 patients (7%) who underwent revision surgeries for baseplate failure and periprosthetic humeral fracture. There were no cases of early humeral loosening. Matchstick autograft humeral augmentation is a simple, promising surgical technique with low intraoperative complication rates and good short-term radiographic outcomes. When the implant fill ratio is successfully reduced, there is a possible lower risk of humeral stress shielding. The authors believe this technique can help maximize implant stability in cementless shoulder arthroplasty and preserve humeral bone stock for future revision surgeries.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>38218403</pmid><doi>10.1016/j.jse.2023.11.021</doi><orcidid>https://orcid.org/0000-0001-9828-7174</orcidid><orcidid>https://orcid.org/0000-0003-0865-858X</orcidid><orcidid>https://orcid.org/0000-0002-7992-709X</orcidid><orcidid>https://orcid.org/0000-0001-5369-5780</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1058-2746
ispartof Journal of shoulder and elbow surgery, 2024-08, Vol.33 (8), p.e422-e428
issn 1058-2746
1532-6500
1532-6500
language eng
recordid cdi_proquest_miscellaneous_2929033769
source ScienceDirect Journals (5 years ago - present)
subjects Cementless reverse total shoulder arthroplasty
fill ratio
humeral autograft
matchstick
proximal humeral bone loss
stress shielding
title Cementless reverse total shoulder arthroplasty implantation with humeral matchstick autograft augmentation: early radiographic outcomes
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-15T06%3A25%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Cementless%20reverse%20total%20shoulder%20arthroplasty%20implantation%20with%20humeral%20matchstick%20autograft%20augmentation:%20early%20radiographic%20outcomes&rft.jtitle=Journal%20of%20shoulder%20and%20elbow%20surgery&rft.au=Montemaggi,%20Paolo&rft.date=2024-08-01&rft.volume=33&rft.issue=8&rft.spage=e422&rft.epage=e428&rft.pages=e422-e428&rft.issn=1058-2746&rft.eissn=1532-6500&rft_id=info:doi/10.1016/j.jse.2023.11.021&rft_dat=%3Cproquest_cross%3E2929033769%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2929033769&rft_id=info:pmid/38218403&rft_els_id=S1058274624000223&rfr_iscdi=true