Non-Invasive Kinematic Analysis of the Triceps Surae Muscle-Tendon Complex during a Gait

The purpose of this study is to calculate the length and velocity change of gastrocnemius and soleus muscle-tendon complex (MTC) for diagnosis and estimation of the rehabilitation procedure of the patient from non-invasive 3D markers. The previous method measuring the length of MTC has been dependan...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Key engineering materials 2006-01, Vol.321-323, p.1090-1093
Hauptverfasser: Lee, Sang Sik, Mun, Joung H., Choi, Ahn Ryul, Rim, Yong Hoon
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1093
container_issue
container_start_page 1090
container_title Key engineering materials
container_volume 321-323
creator Lee, Sang Sik
Mun, Joung H.
Choi, Ahn Ryul
Rim, Yong Hoon
description The purpose of this study is to calculate the length and velocity change of gastrocnemius and soleus muscle-tendon complex (MTC) for diagnosis and estimation of the rehabilitation procedure of the patient from non-invasive 3D markers. The previous method measuring the length of MTC has been dependant on the regression equation based on the rotation angle in the sagittal plane. However, in view of the fact that movement analysis is based on the human body having a variety of structure, the measurement using merely rotation angle and regression equation which not based on each subject shank and foot length might not be accurate. In order to overcome these limitations, the length change of MTC is calculated, employing 3D MTC model accompanied with the trajectory data of markers attached anatomical landmarks, each subject measurements and femur condyle radius. Basically, more accurate length change could be acquired through the 3D trajectory data of markers in comparing with 2D data based on the rotation angle. As our study, the difference of the gastrocnemius length change between 3D marker trajectory based method and the method using a 2-D angle was approximately 4% (2cm) at maximum contraction and 1% (0.5cm) at maximum relaxation. Similarly, the difference in terms of the soleus was approximately 0.7% (0.3cm) at maximum contraction and 0.5% (0.2cm) at maximum relaxation.
doi_str_mv 10.4028/www.scientific.net/KEM.321-323.1090
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_29274356</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>29274356</sourcerecordid><originalsourceid>FETCH-LOGICAL-c238t-4d6a859172915d4e3ad0f802d3a913f8f4e9c9d9d2dc0a76815a4b1b067a8a933</originalsourceid><addsrcrecordid>eNqV0EtLAzEQB_BFFKyP75CTF9ltHvvKsZT6wNfBCt7CmMxqZJutSbbVb2-kgmcPw8zhz5_hl2XnjBYl5e10u90WQVt00XZWFw7j9GZxVwjOcsFFwaike9mE1TXPZSOr_XRTJnLZ8vowOwrhnVLBWlZNsuf7weXXbgPBbpDcWIcriFaTmYP-K9hAho7ENyRLbzWuA3kcPSC5G4PuMV-iM4Mj82G17vGTmNFb90qAXIKNJ9lBB33A0999nD1dLJbzq_z24fJ6PrvNNRdtzEtTQ1tJ1nDJKlOiAEO7lnIjQDLRtV2JUksjDTeaQlOnp6F8YS-0bqAFKcRxdrbrXfvhY8QQ1coGjX0PDocxKC55U4qqTsH5Lqj9EILHTq29XYH_UoyqH1WVVNWfqkqqKqmqpJpGqB_V1LLYtUQPLkTUb-p9GH3SCv_q-QZch4sf</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>29274356</pqid></control><display><type>article</type><title>Non-Invasive Kinematic Analysis of the Triceps Surae Muscle-Tendon Complex during a Gait</title><source>Scientific.net Journals</source><creator>Lee, Sang Sik ; Mun, Joung H. ; Choi, Ahn Ryul ; Rim, Yong Hoon</creator><creatorcontrib>Lee, Sang Sik ; Mun, Joung H. ; Choi, Ahn Ryul ; Rim, Yong Hoon</creatorcontrib><description>The purpose of this study is to calculate the length and velocity change of gastrocnemius and soleus muscle-tendon complex (MTC) for diagnosis and estimation of the rehabilitation procedure of the patient from non-invasive 3D markers. The previous method measuring the length of MTC has been dependant on the regression equation based on the rotation angle in the sagittal plane. However, in view of the fact that movement analysis is based on the human body having a variety of structure, the measurement using merely rotation angle and regression equation which not based on each subject shank and foot length might not be accurate. In order to overcome these limitations, the length change of MTC is calculated, employing 3D MTC model accompanied with the trajectory data of markers attached anatomical landmarks, each subject measurements and femur condyle radius. Basically, more accurate length change could be acquired through the 3D trajectory data of markers in comparing with 2D data based on the rotation angle. As our study, the difference of the gastrocnemius length change between 3D marker trajectory based method and the method using a 2-D angle was approximately 4% (2cm) at maximum contraction and 1% (0.5cm) at maximum relaxation. Similarly, the difference in terms of the soleus was approximately 0.7% (0.3cm) at maximum contraction and 0.5% (0.2cm) at maximum relaxation.</description><identifier>ISSN: 1013-9826</identifier><identifier>ISSN: 1662-9795</identifier><identifier>EISSN: 1662-9795</identifier><identifier>DOI: 10.4028/www.scientific.net/KEM.321-323.1090</identifier><language>eng</language><publisher>Trans Tech Publications Ltd</publisher><ispartof>Key engineering materials, 2006-01, Vol.321-323, p.1090-1093</ispartof><rights>2006 Trans Tech Publications Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c238t-4d6a859172915d4e3ad0f802d3a913f8f4e9c9d9d2dc0a76815a4b1b067a8a933</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.scientific.net/Image/TitleCover/42?width=600</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Lee, Sang Sik</creatorcontrib><creatorcontrib>Mun, Joung H.</creatorcontrib><creatorcontrib>Choi, Ahn Ryul</creatorcontrib><creatorcontrib>Rim, Yong Hoon</creatorcontrib><title>Non-Invasive Kinematic Analysis of the Triceps Surae Muscle-Tendon Complex during a Gait</title><title>Key engineering materials</title><description>The purpose of this study is to calculate the length and velocity change of gastrocnemius and soleus muscle-tendon complex (MTC) for diagnosis and estimation of the rehabilitation procedure of the patient from non-invasive 3D markers. The previous method measuring the length of MTC has been dependant on the regression equation based on the rotation angle in the sagittal plane. However, in view of the fact that movement analysis is based on the human body having a variety of structure, the measurement using merely rotation angle and regression equation which not based on each subject shank and foot length might not be accurate. In order to overcome these limitations, the length change of MTC is calculated, employing 3D MTC model accompanied with the trajectory data of markers attached anatomical landmarks, each subject measurements and femur condyle radius. Basically, more accurate length change could be acquired through the 3D trajectory data of markers in comparing with 2D data based on the rotation angle. As our study, the difference of the gastrocnemius length change between 3D marker trajectory based method and the method using a 2-D angle was approximately 4% (2cm) at maximum contraction and 1% (0.5cm) at maximum relaxation. Similarly, the difference in terms of the soleus was approximately 0.7% (0.3cm) at maximum contraction and 0.5% (0.2cm) at maximum relaxation.</description><issn>1013-9826</issn><issn>1662-9795</issn><issn>1662-9795</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNqV0EtLAzEQB_BFFKyP75CTF9ltHvvKsZT6wNfBCt7CmMxqZJutSbbVb2-kgmcPw8zhz5_hl2XnjBYl5e10u90WQVt00XZWFw7j9GZxVwjOcsFFwaike9mE1TXPZSOr_XRTJnLZ8vowOwrhnVLBWlZNsuf7weXXbgPBbpDcWIcriFaTmYP-K9hAho7ENyRLbzWuA3kcPSC5G4PuMV-iM4Mj82G17vGTmNFb90qAXIKNJ9lBB33A0999nD1dLJbzq_z24fJ6PrvNNRdtzEtTQ1tJ1nDJKlOiAEO7lnIjQDLRtV2JUksjDTeaQlOnp6F8YS-0bqAFKcRxdrbrXfvhY8QQ1coGjX0PDocxKC55U4qqTsH5Lqj9EILHTq29XYH_UoyqH1WVVNWfqkqqKqmqpJpGqB_V1LLYtUQPLkTUb-p9GH3SCv_q-QZch4sf</recordid><startdate>20060101</startdate><enddate>20060101</enddate><creator>Lee, Sang Sik</creator><creator>Mun, Joung H.</creator><creator>Choi, Ahn Ryul</creator><creator>Rim, Yong Hoon</creator><general>Trans Tech Publications Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope></search><sort><creationdate>20060101</creationdate><title>Non-Invasive Kinematic Analysis of the Triceps Surae Muscle-Tendon Complex during a Gait</title><author>Lee, Sang Sik ; Mun, Joung H. ; Choi, Ahn Ryul ; Rim, Yong Hoon</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c238t-4d6a859172915d4e3ad0f802d3a913f8f4e9c9d9d2dc0a76815a4b1b067a8a933</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lee, Sang Sik</creatorcontrib><creatorcontrib>Mun, Joung H.</creatorcontrib><creatorcontrib>Choi, Ahn Ryul</creatorcontrib><creatorcontrib>Rim, Yong Hoon</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><jtitle>Key engineering materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lee, Sang Sik</au><au>Mun, Joung H.</au><au>Choi, Ahn Ryul</au><au>Rim, Yong Hoon</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Non-Invasive Kinematic Analysis of the Triceps Surae Muscle-Tendon Complex during a Gait</atitle><jtitle>Key engineering materials</jtitle><date>2006-01-01</date><risdate>2006</risdate><volume>321-323</volume><spage>1090</spage><epage>1093</epage><pages>1090-1093</pages><issn>1013-9826</issn><issn>1662-9795</issn><eissn>1662-9795</eissn><abstract>The purpose of this study is to calculate the length and velocity change of gastrocnemius and soleus muscle-tendon complex (MTC) for diagnosis and estimation of the rehabilitation procedure of the patient from non-invasive 3D markers. The previous method measuring the length of MTC has been dependant on the regression equation based on the rotation angle in the sagittal plane. However, in view of the fact that movement analysis is based on the human body having a variety of structure, the measurement using merely rotation angle and regression equation which not based on each subject shank and foot length might not be accurate. In order to overcome these limitations, the length change of MTC is calculated, employing 3D MTC model accompanied with the trajectory data of markers attached anatomical landmarks, each subject measurements and femur condyle radius. Basically, more accurate length change could be acquired through the 3D trajectory data of markers in comparing with 2D data based on the rotation angle. As our study, the difference of the gastrocnemius length change between 3D marker trajectory based method and the method using a 2-D angle was approximately 4% (2cm) at maximum contraction and 1% (0.5cm) at maximum relaxation. Similarly, the difference in terms of the soleus was approximately 0.7% (0.3cm) at maximum contraction and 0.5% (0.2cm) at maximum relaxation.</abstract><pub>Trans Tech Publications Ltd</pub><doi>10.4028/www.scientific.net/KEM.321-323.1090</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1013-9826
ispartof Key engineering materials, 2006-01, Vol.321-323, p.1090-1093
issn 1013-9826
1662-9795
1662-9795
language eng
recordid cdi_proquest_miscellaneous_29274356
source Scientific.net Journals
title Non-Invasive Kinematic Analysis of the Triceps Surae Muscle-Tendon Complex during a Gait
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T16%3A41%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Non-Invasive%20Kinematic%20Analysis%20of%20the%20Triceps%20Surae%20Muscle-Tendon%20Complex%20during%20a%20Gait&rft.jtitle=Key%20engineering%20materials&rft.au=Lee,%20Sang%20Sik&rft.date=2006-01-01&rft.volume=321-323&rft.spage=1090&rft.epage=1093&rft.pages=1090-1093&rft.issn=1013-9826&rft.eissn=1662-9795&rft_id=info:doi/10.4028/www.scientific.net/KEM.321-323.1090&rft_dat=%3Cproquest_cross%3E29274356%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=29274356&rft_id=info:pmid/&rfr_iscdi=true