Dynamic Angular Control Of Thermal Therapy With Stationary Multi-Sectored Tubular Ultrasound Applicators Under MR Temperature Monitoring

Multi-sectored ultrasound heating applicators with dynamic angular and longitudinal control of heating profiles are being investigated for the thermal treatment of tumors in sites such as prostate, uterus, and brain. Multi-sectored tubular ultrasound transducers with independent sector power control...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Kinsey, Adam M, Diederich, Chris J, Nau, William H, Ross, Anthony B, Pauly, Kim Butts, Rieke, Viola, Sommer, Graham
Format: Tagungsbericht
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 459
container_issue
container_start_page 455
container_title
container_volume 829
creator Kinsey, Adam M
Diederich, Chris J
Nau, William H
Ross, Anthony B
Pauly, Kim Butts
Rieke, Viola
Sommer, Graham
description Multi-sectored ultrasound heating applicators with dynamic angular and longitudinal control of heating profiles are being investigated for the thermal treatment of tumors in sites such as prostate, uterus, and brain. Multi-sectored tubular ultrasound transducers with independent sector power control were incorporated into interstitial and transurethral applicators and provided dynamic angular control of a heating pattern without requiring device manipulation during treatment. Acoustic beam measurements of each applicator type demonstrated a 35-40 deg acoustic dead zone between each independent sector, with negligible mechanical or electrical coupling. Despite the acoustic dead zone between sectors, simulations and experiments under MR temperature (MRT) monitoring showed that the variance from the maximum lesion radius (scalloping) with all elements activated on a transducer was minimal and did not affect conformal heating of a target area. A biothermal model with a multi-point controller was used to adjust the applied power and treatment time of individual transducer segments as the tissue temperature changed in simulations of thermal lesions with both interstitial and transurethral applicators. Transurethral ultrasound applicators for benign prostatic hyperplasia (BPH) treatment with either three or four sectors conformed a thermal dose to a simulated target area in the angular and radial dimensions. The simulated treatment was controlled to a maximum temperature of 85 deg C, and had a maximum duration of 5 min when power was turned off as the 52 deg C temperature contour reach a predetermined control point for each sector in the tissue. Experiments conducted with multi-sectored applicators under MRT monitoring showed thermal ablation and hyperthermia treatments had little or no border `scalloping', conformed to a pretreatment target area, and correlated very well with the simulated thermal lesions. The radial penetration of the heat treatments in tissue with interstitial (1.5-1.8 mm OD transducer) and transurethral (2.5-4.0 mm OD transducer) applicators was at least 1.5 cm and 2.0 cm, respectively, for a treatment duration of 10 min. Angular control of thermal ablation and hyperthermia therapy often relies upon non-adjustable angular power deposition patterns and/or mechanical manipulation of the heating device. The multi-sectored ultrasound applicators developed in this study provide dynamic control of the angular heating distribution during treatment w
doi_str_mv 10.1063/1.2205516
format Conference Proceeding
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_29227062</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>29227062</sourcerecordid><originalsourceid>FETCH-LOGICAL-p186t-c844503c35014d59232e153b5607384a12139cfc1a2f1ae683221369c63cc9b3</originalsourceid><addsrcrecordid>eNotj01LwzAAhgMquE0P_oOcvHXmo0nb45g6hY2B63C3kaXpFkmTmo_D_oE_2zI9PfA-8MALwANGU4w4fcJTQhBjmF-BMSooyxEleHcNRghVeUZyursF4xC-ECJVUZQj8PN8tqLTEs7sMRnh4dzZ6J2B6xbWJ-U7YS4U_Rl-6niCmyiidlb4M1wlE3W2UTI6rxpYp8OlsDXRi-CSbeCs742WYvABbm2jPFx9wFp1_RCMySu4clYPVtvjHbhphQnq_p8TUL--1PO3bLlevM9ny6zHJY-ZLPOcISopQzhvWEUoUZjRA-PD3TIXmGBayVZiQVosFC8pGRZeSU6lrA50Ah7_sr1330mFuO90kMoYYZVLYU8qQgrECf0FryZlJQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype><pqid>29227062</pqid></control><display><type>conference_proceeding</type><title>Dynamic Angular Control Of Thermal Therapy With Stationary Multi-Sectored Tubular Ultrasound Applicators Under MR Temperature Monitoring</title><source>AIP Journals Complete</source><creator>Kinsey, Adam M ; Diederich, Chris J ; Nau, William H ; Ross, Anthony B ; Pauly, Kim Butts ; Rieke, Viola ; Sommer, Graham</creator><creatorcontrib>Kinsey, Adam M ; Diederich, Chris J ; Nau, William H ; Ross, Anthony B ; Pauly, Kim Butts ; Rieke, Viola ; Sommer, Graham</creatorcontrib><description>Multi-sectored ultrasound heating applicators with dynamic angular and longitudinal control of heating profiles are being investigated for the thermal treatment of tumors in sites such as prostate, uterus, and brain. Multi-sectored tubular ultrasound transducers with independent sector power control were incorporated into interstitial and transurethral applicators and provided dynamic angular control of a heating pattern without requiring device manipulation during treatment. Acoustic beam measurements of each applicator type demonstrated a 35-40 deg acoustic dead zone between each independent sector, with negligible mechanical or electrical coupling. Despite the acoustic dead zone between sectors, simulations and experiments under MR temperature (MRT) monitoring showed that the variance from the maximum lesion radius (scalloping) with all elements activated on a transducer was minimal and did not affect conformal heating of a target area. A biothermal model with a multi-point controller was used to adjust the applied power and treatment time of individual transducer segments as the tissue temperature changed in simulations of thermal lesions with both interstitial and transurethral applicators. Transurethral ultrasound applicators for benign prostatic hyperplasia (BPH) treatment with either three or four sectors conformed a thermal dose to a simulated target area in the angular and radial dimensions. The simulated treatment was controlled to a maximum temperature of 85 deg C, and had a maximum duration of 5 min when power was turned off as the 52 deg C temperature contour reach a predetermined control point for each sector in the tissue. Experiments conducted with multi-sectored applicators under MRT monitoring showed thermal ablation and hyperthermia treatments had little or no border `scalloping', conformed to a pretreatment target area, and correlated very well with the simulated thermal lesions. The radial penetration of the heat treatments in tissue with interstitial (1.5-1.8 mm OD transducer) and transurethral (2.5-4.0 mm OD transducer) applicators was at least 1.5 cm and 2.0 cm, respectively, for a treatment duration of 10 min. Angular control of thermal ablation and hyperthermia therapy often relies upon non-adjustable angular power deposition patterns and/or mechanical manipulation of the heating device. The multi-sectored ultrasound applicators developed in this study provide dynamic control of the angular heating distribution during treatment without device manipulation and maintain previously reported heating penetration and spatial control characteristics of similar ultrasound devices.</description><identifier>ISSN: 0094-243X</identifier><identifier>ISBN: 073540321X</identifier><identifier>ISBN: 9780735403215</identifier><identifier>DOI: 10.1063/1.2205516</identifier><language>eng</language><ispartof>Therapeutic Ultrasound: 5th International Symposium on Therapeutic Ultrasound, 2006, Vol.829, p.455-459</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Kinsey, Adam M</creatorcontrib><creatorcontrib>Diederich, Chris J</creatorcontrib><creatorcontrib>Nau, William H</creatorcontrib><creatorcontrib>Ross, Anthony B</creatorcontrib><creatorcontrib>Pauly, Kim Butts</creatorcontrib><creatorcontrib>Rieke, Viola</creatorcontrib><creatorcontrib>Sommer, Graham</creatorcontrib><title>Dynamic Angular Control Of Thermal Therapy With Stationary Multi-Sectored Tubular Ultrasound Applicators Under MR Temperature Monitoring</title><title>Therapeutic Ultrasound: 5th International Symposium on Therapeutic Ultrasound</title><description>Multi-sectored ultrasound heating applicators with dynamic angular and longitudinal control of heating profiles are being investigated for the thermal treatment of tumors in sites such as prostate, uterus, and brain. Multi-sectored tubular ultrasound transducers with independent sector power control were incorporated into interstitial and transurethral applicators and provided dynamic angular control of a heating pattern without requiring device manipulation during treatment. Acoustic beam measurements of each applicator type demonstrated a 35-40 deg acoustic dead zone between each independent sector, with negligible mechanical or electrical coupling. Despite the acoustic dead zone between sectors, simulations and experiments under MR temperature (MRT) monitoring showed that the variance from the maximum lesion radius (scalloping) with all elements activated on a transducer was minimal and did not affect conformal heating of a target area. A biothermal model with a multi-point controller was used to adjust the applied power and treatment time of individual transducer segments as the tissue temperature changed in simulations of thermal lesions with both interstitial and transurethral applicators. Transurethral ultrasound applicators for benign prostatic hyperplasia (BPH) treatment with either three or four sectors conformed a thermal dose to a simulated target area in the angular and radial dimensions. The simulated treatment was controlled to a maximum temperature of 85 deg C, and had a maximum duration of 5 min when power was turned off as the 52 deg C temperature contour reach a predetermined control point for each sector in the tissue. Experiments conducted with multi-sectored applicators under MRT monitoring showed thermal ablation and hyperthermia treatments had little or no border `scalloping', conformed to a pretreatment target area, and correlated very well with the simulated thermal lesions. The radial penetration of the heat treatments in tissue with interstitial (1.5-1.8 mm OD transducer) and transurethral (2.5-4.0 mm OD transducer) applicators was at least 1.5 cm and 2.0 cm, respectively, for a treatment duration of 10 min. Angular control of thermal ablation and hyperthermia therapy often relies upon non-adjustable angular power deposition patterns and/or mechanical manipulation of the heating device. The multi-sectored ultrasound applicators developed in this study provide dynamic control of the angular heating distribution during treatment without device manipulation and maintain previously reported heating penetration and spatial control characteristics of similar ultrasound devices.</description><issn>0094-243X</issn><isbn>073540321X</isbn><isbn>9780735403215</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2006</creationdate><recordtype>conference_proceeding</recordtype><recordid>eNotj01LwzAAhgMquE0P_oOcvHXmo0nb45g6hY2B63C3kaXpFkmTmo_D_oE_2zI9PfA-8MALwANGU4w4fcJTQhBjmF-BMSooyxEleHcNRghVeUZyursF4xC-ECJVUZQj8PN8tqLTEs7sMRnh4dzZ6J2B6xbWJ-U7YS4U_Rl-6niCmyiidlb4M1wlE3W2UTI6rxpYp8OlsDXRi-CSbeCs742WYvABbm2jPFx9wFp1_RCMySu4clYPVtvjHbhphQnq_p8TUL--1PO3bLlevM9ny6zHJY-ZLPOcISopQzhvWEUoUZjRA-PD3TIXmGBayVZiQVosFC8pGRZeSU6lrA50Ah7_sr1330mFuO90kMoYYZVLYU8qQgrECf0FryZlJQ</recordid><startdate>20060101</startdate><enddate>20060101</enddate><creator>Kinsey, Adam M</creator><creator>Diederich, Chris J</creator><creator>Nau, William H</creator><creator>Ross, Anthony B</creator><creator>Pauly, Kim Butts</creator><creator>Rieke, Viola</creator><creator>Sommer, Graham</creator><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>20060101</creationdate><title>Dynamic Angular Control Of Thermal Therapy With Stationary Multi-Sectored Tubular Ultrasound Applicators Under MR Temperature Monitoring</title><author>Kinsey, Adam M ; Diederich, Chris J ; Nau, William H ; Ross, Anthony B ; Pauly, Kim Butts ; Rieke, Viola ; Sommer, Graham</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p186t-c844503c35014d59232e153b5607384a12139cfc1a2f1ae683221369c63cc9b3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2006</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kinsey, Adam M</creatorcontrib><creatorcontrib>Diederich, Chris J</creatorcontrib><creatorcontrib>Nau, William H</creatorcontrib><creatorcontrib>Ross, Anthony B</creatorcontrib><creatorcontrib>Pauly, Kim Butts</creatorcontrib><creatorcontrib>Rieke, Viola</creatorcontrib><creatorcontrib>Sommer, Graham</creatorcontrib><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kinsey, Adam M</au><au>Diederich, Chris J</au><au>Nau, William H</au><au>Ross, Anthony B</au><au>Pauly, Kim Butts</au><au>Rieke, Viola</au><au>Sommer, Graham</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Dynamic Angular Control Of Thermal Therapy With Stationary Multi-Sectored Tubular Ultrasound Applicators Under MR Temperature Monitoring</atitle><btitle>Therapeutic Ultrasound: 5th International Symposium on Therapeutic Ultrasound</btitle><date>2006-01-01</date><risdate>2006</risdate><volume>829</volume><spage>455</spage><epage>459</epage><pages>455-459</pages><issn>0094-243X</issn><isbn>073540321X</isbn><isbn>9780735403215</isbn><abstract>Multi-sectored ultrasound heating applicators with dynamic angular and longitudinal control of heating profiles are being investigated for the thermal treatment of tumors in sites such as prostate, uterus, and brain. Multi-sectored tubular ultrasound transducers with independent sector power control were incorporated into interstitial and transurethral applicators and provided dynamic angular control of a heating pattern without requiring device manipulation during treatment. Acoustic beam measurements of each applicator type demonstrated a 35-40 deg acoustic dead zone between each independent sector, with negligible mechanical or electrical coupling. Despite the acoustic dead zone between sectors, simulations and experiments under MR temperature (MRT) monitoring showed that the variance from the maximum lesion radius (scalloping) with all elements activated on a transducer was minimal and did not affect conformal heating of a target area. A biothermal model with a multi-point controller was used to adjust the applied power and treatment time of individual transducer segments as the tissue temperature changed in simulations of thermal lesions with both interstitial and transurethral applicators. Transurethral ultrasound applicators for benign prostatic hyperplasia (BPH) treatment with either three or four sectors conformed a thermal dose to a simulated target area in the angular and radial dimensions. The simulated treatment was controlled to a maximum temperature of 85 deg C, and had a maximum duration of 5 min when power was turned off as the 52 deg C temperature contour reach a predetermined control point for each sector in the tissue. Experiments conducted with multi-sectored applicators under MRT monitoring showed thermal ablation and hyperthermia treatments had little or no border `scalloping', conformed to a pretreatment target area, and correlated very well with the simulated thermal lesions. The radial penetration of the heat treatments in tissue with interstitial (1.5-1.8 mm OD transducer) and transurethral (2.5-4.0 mm OD transducer) applicators was at least 1.5 cm and 2.0 cm, respectively, for a treatment duration of 10 min. Angular control of thermal ablation and hyperthermia therapy often relies upon non-adjustable angular power deposition patterns and/or mechanical manipulation of the heating device. The multi-sectored ultrasound applicators developed in this study provide dynamic control of the angular heating distribution during treatment without device manipulation and maintain previously reported heating penetration and spatial control characteristics of similar ultrasound devices.</abstract><doi>10.1063/1.2205516</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0094-243X
ispartof Therapeutic Ultrasound: 5th International Symposium on Therapeutic Ultrasound, 2006, Vol.829, p.455-459
issn 0094-243X
language eng
recordid cdi_proquest_miscellaneous_29227062
source AIP Journals Complete
title Dynamic Angular Control Of Thermal Therapy With Stationary Multi-Sectored Tubular Ultrasound Applicators Under MR Temperature Monitoring
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T05%3A32%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Dynamic%20Angular%20Control%20Of%20Thermal%20Therapy%20With%20Stationary%20Multi-Sectored%20Tubular%20Ultrasound%20Applicators%20Under%20MR%20Temperature%20Monitoring&rft.btitle=Therapeutic%20Ultrasound:%205th%20International%20Symposium%20on%20Therapeutic%20Ultrasound&rft.au=Kinsey,%20Adam%20M&rft.date=2006-01-01&rft.volume=829&rft.spage=455&rft.epage=459&rft.pages=455-459&rft.issn=0094-243X&rft.isbn=073540321X&rft.isbn_list=9780735403215&rft_id=info:doi/10.1063/1.2205516&rft_dat=%3Cproquest%3E29227062%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=29227062&rft_id=info:pmid/&rfr_iscdi=true