Influence of the size of a normal probe’s piezoelectric plate on the amplitude of a detected echo signal

A computer model for operation of normal probes combined with a flaw detector was used to consider the effect of the size (radius) of a piezoelectric plate on the amplitude of a detected echo signal. It is shown that the amplitude variation is mainly related to the acoustic part of the electroacoust...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Russian journal of nondestructive testing 2006-01, Vol.42 (1), p.42-46
1. Verfasser: Danilov, V. N.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A computer model for operation of normal probes combined with a flaw detector was used to consider the effect of the size (radius) of a piezoelectric plate on the amplitude of a detected echo signal. It is shown that the amplitude variation is mainly related to the acoustic part of the electroacoustic channel (a function of signal damping during wave propagation to and from a flaw).