Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit
Purpose: Image-guided percutaneous drainage for abscesses is known as a safe and effective treatment. The computed tomography-guided percutaneous drainage kit Drainaway (SB Kawasumi Co., Ltd.), developed on the basis of a modified trocar method, has made it possible to complete the procedure only un...
Gespeichert in:
Veröffentlicht in: | Interventional Radiology 2023/11/01, Vol.8(3), pp.130-135 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 135 |
---|---|
container_issue | 3 |
container_start_page | 130 |
container_title | Interventional Radiology |
container_volume | 8 |
creator | Togawa, Koji Nakatsuka, Seishi Tsukada, Jitsuro Ito, Nobutake Yamamoto, Yosuke Kogo, Togo Yoshikawa, Hiroki Misu, Manabu Tamura, Masashi Soga, Shigeyoshi Inoue, Masanori Yashiro, Hideki Kurata, Tadayoshi Okada, Masahiro Jinzaki, Masahiro |
description | Purpose: Image-guided percutaneous drainage for abscesses is known as a safe and effective treatment. The computed tomography-guided percutaneous drainage kit Drainaway (SB Kawasumi Co., Ltd.), developed on the basis of a modified trocar method, has made it possible to complete the procedure only under computed tomography guidance without radiographic fluoroscopy. This study investigated the feasibility and safety of Drainaway for abscess drainage.Material and Methods: In this retrospective observational study, 28 procedures in 27 patients (18 men and 9 women; age 67.0 ± 12.3 years) who underwent computed tomography-guided drainage using Drainaway between March and December 2021 at seven affiliated hospitals were analyzed. Patients with symptomatic, puncturable on computed tomography and refractory abscesses were included. Technical success (successful drainage with computed tomography alone), primary clinical success (successful drainage with Drainaway alone), secondary clinical success (avoidance of surgery), and complications were evaluated.Results: The sites of the abscesses were the intraperitoneal, retroperitoneal, and thoracic cavities in 19, 5, and 2 patients, respectively, and subcutaneous tissue in 1 patient. The mean size of the abscesses was 7.1 ± 3.4 cm. The technical success rate was 96.4%; the ligament of the puncture route could not be penetrated in one case. The primary clinical success rate was 77.8%, whereas the secondary clinical success rate of catheter upsizing or replacement was 96.3%. Complications included one case of biliary pleurisy that required drainage.Conclusions: Drainaway is a useful device that allows abscess drainage using only computed tomography guidance without radiographic fluoroscopy. |
doi_str_mv | 10.22575/interventionalradiology.2022-0027 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2895706677</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2895706677</sourcerecordid><originalsourceid>FETCH-LOGICAL-c381t-da3b1f3fc5283aded72402ef02b3dc666a245e9985cf409696c1efaa5ed4f5f03</originalsourceid><addsrcrecordid>eNp1kE1PwzAMhisEEtPYf-gRIXWkSdOPI4xPMcRlO0demrSZ2qYkGaj_noxNhcsOli3r8Wv7DYKbGM0xphm9VZ0T5kt0TukOGgOl0o2uhjlGGEcI4ewsmOCE-Log9PxffRnMrN0ij8QJoghNAljott85UYYr3erKQF8PUbVTpe88GFAdVCL8Vq4O33WppNqDRnMw4UrwulOfOxGureqqEI78Nwx_k2_KXQUXEhorZsc8DdZPj6vFS7T8eH5d3C0jTvLYRSWQTSyJ5BTnBPz6DCcIC4nwhpQ8TVPACRVFkVMuE1SkRcpjIQGoKBNJJSLT4Pqg2xvtr7KOtcpy0TTQCb2zDOcFzVCaZplH7w8oN9paIyTrjWrBDCxG7NdidsJitreY7S0m4x9b6_yrowQYp3gjTirkjPgYdUae12CY6MgPnbSaRw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2895706677</pqid></control><display><type>article</type><title>Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit</title><source>J-STAGE Free</source><source>PubMed Central</source><source>PubMed Central Open Access</source><creator>Togawa, Koji ; Nakatsuka, Seishi ; Tsukada, Jitsuro ; Ito, Nobutake ; Yamamoto, Yosuke ; Kogo, Togo ; Yoshikawa, Hiroki ; Misu, Manabu ; Tamura, Masashi ; Soga, Shigeyoshi ; Inoue, Masanori ; Yashiro, Hideki ; Kurata, Tadayoshi ; Okada, Masahiro ; Jinzaki, Masahiro</creator><creatorcontrib>Togawa, Koji ; Nakatsuka, Seishi ; Tsukada, Jitsuro ; Ito, Nobutake ; Yamamoto, Yosuke ; Kogo, Togo ; Yoshikawa, Hiroki ; Misu, Manabu ; Tamura, Masashi ; Soga, Shigeyoshi ; Inoue, Masanori ; Yashiro, Hideki ; Kurata, Tadayoshi ; Okada, Masahiro ; Jinzaki, Masahiro</creatorcontrib><description>Purpose: Image-guided percutaneous drainage for abscesses is known as a safe and effective treatment. The computed tomography-guided percutaneous drainage kit Drainaway (SB Kawasumi Co., Ltd.), developed on the basis of a modified trocar method, has made it possible to complete the procedure only under computed tomography guidance without radiographic fluoroscopy. This study investigated the feasibility and safety of Drainaway for abscess drainage.Material and Methods: In this retrospective observational study, 28 procedures in 27 patients (18 men and 9 women; age 67.0 ± 12.3 years) who underwent computed tomography-guided drainage using Drainaway between March and December 2021 at seven affiliated hospitals were analyzed. Patients with symptomatic, puncturable on computed tomography and refractory abscesses were included. Technical success (successful drainage with computed tomography alone), primary clinical success (successful drainage with Drainaway alone), secondary clinical success (avoidance of surgery), and complications were evaluated.Results: The sites of the abscesses were the intraperitoneal, retroperitoneal, and thoracic cavities in 19, 5, and 2 patients, respectively, and subcutaneous tissue in 1 patient. The mean size of the abscesses was 7.1 ± 3.4 cm. The technical success rate was 96.4%; the ligament of the puncture route could not be penetrated in one case. The primary clinical success rate was 77.8%, whereas the secondary clinical success rate of catheter upsizing or replacement was 96.3%. Complications included one case of biliary pleurisy that required drainage.Conclusions: Drainaway is a useful device that allows abscess drainage using only computed tomography guidance without radiographic fluoroscopy.</description><identifier>ISSN: 2432-0935</identifier><identifier>EISSN: 2432-0935</identifier><identifier>DOI: 10.22575/interventionalradiology.2022-0027</identifier><language>eng</language><publisher>Japanese Society of Interventional Radiology</publisher><subject>abscess drainage ; CT-guided drainage ; modified trocar technique</subject><ispartof>Interventional Radiology, 2023/11/01, Vol.8(3), pp.130-135</ispartof><rights>2023 Japanese Society of Interventional Radiology</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c381t-da3b1f3fc5283aded72402ef02b3dc666a245e9985cf409696c1efaa5ed4f5f03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,1877,27901,27902</link.rule.ids></links><search><creatorcontrib>Togawa, Koji</creatorcontrib><creatorcontrib>Nakatsuka, Seishi</creatorcontrib><creatorcontrib>Tsukada, Jitsuro</creatorcontrib><creatorcontrib>Ito, Nobutake</creatorcontrib><creatorcontrib>Yamamoto, Yosuke</creatorcontrib><creatorcontrib>Kogo, Togo</creatorcontrib><creatorcontrib>Yoshikawa, Hiroki</creatorcontrib><creatorcontrib>Misu, Manabu</creatorcontrib><creatorcontrib>Tamura, Masashi</creatorcontrib><creatorcontrib>Soga, Shigeyoshi</creatorcontrib><creatorcontrib>Inoue, Masanori</creatorcontrib><creatorcontrib>Yashiro, Hideki</creatorcontrib><creatorcontrib>Kurata, Tadayoshi</creatorcontrib><creatorcontrib>Okada, Masahiro</creatorcontrib><creatorcontrib>Jinzaki, Masahiro</creatorcontrib><title>Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit</title><title>Interventional Radiology</title><description>Purpose: Image-guided percutaneous drainage for abscesses is known as a safe and effective treatment. The computed tomography-guided percutaneous drainage kit Drainaway (SB Kawasumi Co., Ltd.), developed on the basis of a modified trocar method, has made it possible to complete the procedure only under computed tomography guidance without radiographic fluoroscopy. This study investigated the feasibility and safety of Drainaway for abscess drainage.Material and Methods: In this retrospective observational study, 28 procedures in 27 patients (18 men and 9 women; age 67.0 ± 12.3 years) who underwent computed tomography-guided drainage using Drainaway between March and December 2021 at seven affiliated hospitals were analyzed. Patients with symptomatic, puncturable on computed tomography and refractory abscesses were included. Technical success (successful drainage with computed tomography alone), primary clinical success (successful drainage with Drainaway alone), secondary clinical success (avoidance of surgery), and complications were evaluated.Results: The sites of the abscesses were the intraperitoneal, retroperitoneal, and thoracic cavities in 19, 5, and 2 patients, respectively, and subcutaneous tissue in 1 patient. The mean size of the abscesses was 7.1 ± 3.4 cm. The technical success rate was 96.4%; the ligament of the puncture route could not be penetrated in one case. The primary clinical success rate was 77.8%, whereas the secondary clinical success rate of catheter upsizing or replacement was 96.3%. Complications included one case of biliary pleurisy that required drainage.Conclusions: Drainaway is a useful device that allows abscess drainage using only computed tomography guidance without radiographic fluoroscopy.</description><subject>abscess drainage</subject><subject>CT-guided drainage</subject><subject>modified trocar technique</subject><issn>2432-0935</issn><issn>2432-0935</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp1kE1PwzAMhisEEtPYf-gRIXWkSdOPI4xPMcRlO0demrSZ2qYkGaj_noxNhcsOli3r8Wv7DYKbGM0xphm9VZ0T5kt0TukOGgOl0o2uhjlGGEcI4ewsmOCE-Log9PxffRnMrN0ij8QJoghNAljott85UYYr3erKQF8PUbVTpe88GFAdVCL8Vq4O33WppNqDRnMw4UrwulOfOxGureqqEI78Nwx_k2_KXQUXEhorZsc8DdZPj6vFS7T8eH5d3C0jTvLYRSWQTSyJ5BTnBPz6DCcIC4nwhpQ8TVPACRVFkVMuE1SkRcpjIQGoKBNJJSLT4Pqg2xvtr7KOtcpy0TTQCb2zDOcFzVCaZplH7w8oN9paIyTrjWrBDCxG7NdidsJitreY7S0m4x9b6_yrowQYp3gjTirkjPgYdUae12CY6MgPnbSaRw</recordid><startdate>20231101</startdate><enddate>20231101</enddate><creator>Togawa, Koji</creator><creator>Nakatsuka, Seishi</creator><creator>Tsukada, Jitsuro</creator><creator>Ito, Nobutake</creator><creator>Yamamoto, Yosuke</creator><creator>Kogo, Togo</creator><creator>Yoshikawa, Hiroki</creator><creator>Misu, Manabu</creator><creator>Tamura, Masashi</creator><creator>Soga, Shigeyoshi</creator><creator>Inoue, Masanori</creator><creator>Yashiro, Hideki</creator><creator>Kurata, Tadayoshi</creator><creator>Okada, Masahiro</creator><creator>Jinzaki, Masahiro</creator><general>Japanese Society of Interventional Radiology</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20231101</creationdate><title>Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit</title><author>Togawa, Koji ; Nakatsuka, Seishi ; Tsukada, Jitsuro ; Ito, Nobutake ; Yamamoto, Yosuke ; Kogo, Togo ; Yoshikawa, Hiroki ; Misu, Manabu ; Tamura, Masashi ; Soga, Shigeyoshi ; Inoue, Masanori ; Yashiro, Hideki ; Kurata, Tadayoshi ; Okada, Masahiro ; Jinzaki, Masahiro</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c381t-da3b1f3fc5283aded72402ef02b3dc666a245e9985cf409696c1efaa5ed4f5f03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>abscess drainage</topic><topic>CT-guided drainage</topic><topic>modified trocar technique</topic><toplevel>online_resources</toplevel><creatorcontrib>Togawa, Koji</creatorcontrib><creatorcontrib>Nakatsuka, Seishi</creatorcontrib><creatorcontrib>Tsukada, Jitsuro</creatorcontrib><creatorcontrib>Ito, Nobutake</creatorcontrib><creatorcontrib>Yamamoto, Yosuke</creatorcontrib><creatorcontrib>Kogo, Togo</creatorcontrib><creatorcontrib>Yoshikawa, Hiroki</creatorcontrib><creatorcontrib>Misu, Manabu</creatorcontrib><creatorcontrib>Tamura, Masashi</creatorcontrib><creatorcontrib>Soga, Shigeyoshi</creatorcontrib><creatorcontrib>Inoue, Masanori</creatorcontrib><creatorcontrib>Yashiro, Hideki</creatorcontrib><creatorcontrib>Kurata, Tadayoshi</creatorcontrib><creatorcontrib>Okada, Masahiro</creatorcontrib><creatorcontrib>Jinzaki, Masahiro</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Interventional Radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Togawa, Koji</au><au>Nakatsuka, Seishi</au><au>Tsukada, Jitsuro</au><au>Ito, Nobutake</au><au>Yamamoto, Yosuke</au><au>Kogo, Togo</au><au>Yoshikawa, Hiroki</au><au>Misu, Manabu</au><au>Tamura, Masashi</au><au>Soga, Shigeyoshi</au><au>Inoue, Masanori</au><au>Yashiro, Hideki</au><au>Kurata, Tadayoshi</au><au>Okada, Masahiro</au><au>Jinzaki, Masahiro</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit</atitle><jtitle>Interventional Radiology</jtitle><date>2023-11-01</date><risdate>2023</risdate><volume>8</volume><issue>3</issue><spage>130</spage><epage>135</epage><pages>130-135</pages><artnum>2022-0027</artnum><issn>2432-0935</issn><eissn>2432-0935</eissn><abstract>Purpose: Image-guided percutaneous drainage for abscesses is known as a safe and effective treatment. The computed tomography-guided percutaneous drainage kit Drainaway (SB Kawasumi Co., Ltd.), developed on the basis of a modified trocar method, has made it possible to complete the procedure only under computed tomography guidance without radiographic fluoroscopy. This study investigated the feasibility and safety of Drainaway for abscess drainage.Material and Methods: In this retrospective observational study, 28 procedures in 27 patients (18 men and 9 women; age 67.0 ± 12.3 years) who underwent computed tomography-guided drainage using Drainaway between March and December 2021 at seven affiliated hospitals were analyzed. Patients with symptomatic, puncturable on computed tomography and refractory abscesses were included. Technical success (successful drainage with computed tomography alone), primary clinical success (successful drainage with Drainaway alone), secondary clinical success (avoidance of surgery), and complications were evaluated.Results: The sites of the abscesses were the intraperitoneal, retroperitoneal, and thoracic cavities in 19, 5, and 2 patients, respectively, and subcutaneous tissue in 1 patient. The mean size of the abscesses was 7.1 ± 3.4 cm. The technical success rate was 96.4%; the ligament of the puncture route could not be penetrated in one case. The primary clinical success rate was 77.8%, whereas the secondary clinical success rate of catheter upsizing or replacement was 96.3%. Complications included one case of biliary pleurisy that required drainage.Conclusions: Drainaway is a useful device that allows abscess drainage using only computed tomography guidance without radiographic fluoroscopy.</abstract><pub>Japanese Society of Interventional Radiology</pub><doi>10.22575/interventionalradiology.2022-0027</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2432-0935 |
ispartof | Interventional Radiology, 2023/11/01, Vol.8(3), pp.130-135 |
issn | 2432-0935 2432-0935 |
language | eng |
recordid | cdi_proquest_miscellaneous_2895706677 |
source | J-STAGE Free; PubMed Central; PubMed Central Open Access |
subjects | abscess drainage CT-guided drainage modified trocar technique |
title | Computed Tomography-guided Drainage with Modified Trocar Technique Using a Drainaway Drainage Kit |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-13T19%3A29%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Computed%20Tomography-guided%20Drainage%20with%20Modified%20Trocar%20Technique%20Using%20a%20Drainaway%20Drainage%20Kit&rft.jtitle=Interventional%20Radiology&rft.au=Togawa,%20Koji&rft.date=2023-11-01&rft.volume=8&rft.issue=3&rft.spage=130&rft.epage=135&rft.pages=130-135&rft.artnum=2022-0027&rft.issn=2432-0935&rft.eissn=2432-0935&rft_id=info:doi/10.22575/interventionalradiology.2022-0027&rft_dat=%3Cproquest_cross%3E2895706677%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2895706677&rft_id=info:pmid/&rfr_iscdi=true |