An Activated Structure Transformable Ratiometric Photoacoustic Nanoprobe for Real-Time Dynamic Monitoring of H2S In Vivo
H2S has emerged as a promising biomarker for many diseases such as colon cancer and metformin-induced hepatotoxicity. Real-time monitoring of H2S levels in vivo is significant for early accurate diagnosis of these diseases. Herein, a new accurate and reliable nanoprobe (Au NRs@Ag) was designed for r...
Gespeichert in:
Veröffentlicht in: | Nano letters 2023-11, Vol.23 (22), p.10642-10650 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 10650 |
---|---|
container_issue | 22 |
container_start_page | 10642 |
container_title | Nano letters |
container_volume | 23 |
creator | Wen, Xingwang Bi, Shenghui Wang, Chunxia Zeng, Songjun |
description | H2S has emerged as a promising biomarker for many diseases such as colon cancer and metformin-induced hepatotoxicity. Real-time monitoring of H2S levels in vivo is significant for early accurate diagnosis of these diseases. Herein, a new accurate and reliable nanoprobe (Au NRs@Ag) was designed for real-time dynamic ratiometric photoacoustic (PA) imaging of H2S in vivo based on the endogenous H2S-triggered local surface plasmon resonance (LSPR) red-shift. The Au NRs@Ag nanoprobe can be readily converted into Au NRs@Ag2S via the endogenous H2S-activated in situ sulfurative reaction, subsequently leading to a significant red-shift of the LSPR wavelength from 808 to 980 nm and enabling accurate ratiometric PA (PA980/PA808) imaging of H2S. Moreover, dynamic ratiometric PA imaging of metformin-induced hepatotoxicity was also successfully achieved by the designed PA imaging strategy. These findings provide the possibility of designing a new ratiometric PA imaging strategy for dynamic in situ monitoring of H2S-related diseases. |
doi_str_mv | 10.1021/acs.nanolett.3c03980 |
format | Article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_2889996692</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2889996692</sourcerecordid><originalsourceid>FETCH-LOGICAL-p188t-8888a5cc11b6369e448c0ef341c89fd83a7f51be490b0d6f578842711c21175b3</originalsourceid><addsrcrecordid>eNotT0tLAzEYDIJgrf4DDzl62ZrHPpJjqY8W6oN29Vqy6ReN7CY1yRb99wZ0LsMww_fNIHRFyYwSRm-UjjOnnO8hpRnXhEtBTtCEVpwUtZTsDJ3H-EkIkbwiE_Q9d3iukz2qBHu8TWHUaQyA26BcND4MqusBb1SyfoAUrMYvHz55pf0YU1ZP-dUh-A5wDuMNqL5o7QD49sepIfuP3tnkg3Xv2Bu8ZFu8cvjNHv0FOjWqj3D5z1P0en_XLpbF-vlhtZiviwMVIhUiQ1VaU9rVvJZQlkITMLykWkizF1w1pqIdlJJ0ZF-bqhGiZA2lmlHaVB2fouu_u7nl1wgx7QYbNfS9cpA37JgQUsq6loz_AsnVYlk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2889996692</pqid></control><display><type>article</type><title>An Activated Structure Transformable Ratiometric Photoacoustic Nanoprobe for Real-Time Dynamic Monitoring of H2S In Vivo</title><source>ACS Publications</source><creator>Wen, Xingwang ; Bi, Shenghui ; Wang, Chunxia ; Zeng, Songjun</creator><creatorcontrib>Wen, Xingwang ; Bi, Shenghui ; Wang, Chunxia ; Zeng, Songjun</creatorcontrib><description>H2S has emerged as a promising biomarker for many diseases such as colon cancer and metformin-induced hepatotoxicity. Real-time monitoring of H2S levels in vivo is significant for early accurate diagnosis of these diseases. Herein, a new accurate and reliable nanoprobe (Au NRs@Ag) was designed for real-time dynamic ratiometric photoacoustic (PA) imaging of H2S in vivo based on the endogenous H2S-triggered local surface plasmon resonance (LSPR) red-shift. The Au NRs@Ag nanoprobe can be readily converted into Au NRs@Ag2S via the endogenous H2S-activated in situ sulfurative reaction, subsequently leading to a significant red-shift of the LSPR wavelength from 808 to 980 nm and enabling accurate ratiometric PA (PA980/PA808) imaging of H2S. Moreover, dynamic ratiometric PA imaging of metformin-induced hepatotoxicity was also successfully achieved by the designed PA imaging strategy. These findings provide the possibility of designing a new ratiometric PA imaging strategy for dynamic in situ monitoring of H2S-related diseases.</description><identifier>EISSN: 1530-6992</identifier><identifier>DOI: 10.1021/acs.nanolett.3c03980</identifier><language>eng</language><ispartof>Nano letters, 2023-11, Vol.23 (22), p.10642-10650</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Wen, Xingwang</creatorcontrib><creatorcontrib>Bi, Shenghui</creatorcontrib><creatorcontrib>Wang, Chunxia</creatorcontrib><creatorcontrib>Zeng, Songjun</creatorcontrib><title>An Activated Structure Transformable Ratiometric Photoacoustic Nanoprobe for Real-Time Dynamic Monitoring of H2S In Vivo</title><title>Nano letters</title><description>H2S has emerged as a promising biomarker for many diseases such as colon cancer and metformin-induced hepatotoxicity. Real-time monitoring of H2S levels in vivo is significant for early accurate diagnosis of these diseases. Herein, a new accurate and reliable nanoprobe (Au NRs@Ag) was designed for real-time dynamic ratiometric photoacoustic (PA) imaging of H2S in vivo based on the endogenous H2S-triggered local surface plasmon resonance (LSPR) red-shift. The Au NRs@Ag nanoprobe can be readily converted into Au NRs@Ag2S via the endogenous H2S-activated in situ sulfurative reaction, subsequently leading to a significant red-shift of the LSPR wavelength from 808 to 980 nm and enabling accurate ratiometric PA (PA980/PA808) imaging of H2S. Moreover, dynamic ratiometric PA imaging of metformin-induced hepatotoxicity was also successfully achieved by the designed PA imaging strategy. These findings provide the possibility of designing a new ratiometric PA imaging strategy for dynamic in situ monitoring of H2S-related diseases.</description><issn>1530-6992</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNotT0tLAzEYDIJgrf4DDzl62ZrHPpJjqY8W6oN29Vqy6ReN7CY1yRb99wZ0LsMww_fNIHRFyYwSRm-UjjOnnO8hpRnXhEtBTtCEVpwUtZTsDJ3H-EkIkbwiE_Q9d3iukz2qBHu8TWHUaQyA26BcND4MqusBb1SyfoAUrMYvHz55pf0YU1ZP-dUh-A5wDuMNqL5o7QD49sepIfuP3tnkg3Xv2Bu8ZFu8cvjNHv0FOjWqj3D5z1P0en_XLpbF-vlhtZiviwMVIhUiQ1VaU9rVvJZQlkITMLykWkizF1w1pqIdlJJ0ZF-bqhGiZA2lmlHaVB2fouu_u7nl1wgx7QYbNfS9cpA37JgQUsq6loz_AsnVYlk</recordid><startdate>20231122</startdate><enddate>20231122</enddate><creator>Wen, Xingwang</creator><creator>Bi, Shenghui</creator><creator>Wang, Chunxia</creator><creator>Zeng, Songjun</creator><scope>7X8</scope></search><sort><creationdate>20231122</creationdate><title>An Activated Structure Transformable Ratiometric Photoacoustic Nanoprobe for Real-Time Dynamic Monitoring of H2S In Vivo</title><author>Wen, Xingwang ; Bi, Shenghui ; Wang, Chunxia ; Zeng, Songjun</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p188t-8888a5cc11b6369e448c0ef341c89fd83a7f51be490b0d6f578842711c21175b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wen, Xingwang</creatorcontrib><creatorcontrib>Bi, Shenghui</creatorcontrib><creatorcontrib>Wang, Chunxia</creatorcontrib><creatorcontrib>Zeng, Songjun</creatorcontrib><collection>MEDLINE - Academic</collection><jtitle>Nano letters</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wen, Xingwang</au><au>Bi, Shenghui</au><au>Wang, Chunxia</au><au>Zeng, Songjun</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An Activated Structure Transformable Ratiometric Photoacoustic Nanoprobe for Real-Time Dynamic Monitoring of H2S In Vivo</atitle><jtitle>Nano letters</jtitle><date>2023-11-22</date><risdate>2023</risdate><volume>23</volume><issue>22</issue><spage>10642</spage><epage>10650</epage><pages>10642-10650</pages><eissn>1530-6992</eissn><abstract>H2S has emerged as a promising biomarker for many diseases such as colon cancer and metformin-induced hepatotoxicity. Real-time monitoring of H2S levels in vivo is significant for early accurate diagnosis of these diseases. Herein, a new accurate and reliable nanoprobe (Au NRs@Ag) was designed for real-time dynamic ratiometric photoacoustic (PA) imaging of H2S in vivo based on the endogenous H2S-triggered local surface plasmon resonance (LSPR) red-shift. The Au NRs@Ag nanoprobe can be readily converted into Au NRs@Ag2S via the endogenous H2S-activated in situ sulfurative reaction, subsequently leading to a significant red-shift of the LSPR wavelength from 808 to 980 nm and enabling accurate ratiometric PA (PA980/PA808) imaging of H2S. Moreover, dynamic ratiometric PA imaging of metformin-induced hepatotoxicity was also successfully achieved by the designed PA imaging strategy. These findings provide the possibility of designing a new ratiometric PA imaging strategy for dynamic in situ monitoring of H2S-related diseases.</abstract><doi>10.1021/acs.nanolett.3c03980</doi><tpages>9</tpages></addata></record> |
fulltext | fulltext |
identifier | EISSN: 1530-6992 |
ispartof | Nano letters, 2023-11, Vol.23 (22), p.10642-10650 |
issn | 1530-6992 |
language | eng |
recordid | cdi_proquest_miscellaneous_2889996692 |
source | ACS Publications |
title | An Activated Structure Transformable Ratiometric Photoacoustic Nanoprobe for Real-Time Dynamic Monitoring of H2S In Vivo |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-13T18%3A19%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20Activated%20Structure%20Transformable%20Ratiometric%20Photoacoustic%20Nanoprobe%20for%20Real-Time%20Dynamic%20Monitoring%20of%20H2S%20In%20Vivo&rft.jtitle=Nano%20letters&rft.au=Wen,%20Xingwang&rft.date=2023-11-22&rft.volume=23&rft.issue=22&rft.spage=10642&rft.epage=10650&rft.pages=10642-10650&rft.eissn=1530-6992&rft_id=info:doi/10.1021/acs.nanolett.3c03980&rft_dat=%3Cproquest%3E2889996692%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2889996692&rft_id=info:pmid/&rfr_iscdi=true |