A practical method to simulate realistic reduced-exposure CT images by the addition of computationally generated noise

Computed tomography (CT) scanning protocols should be optimized to minimize the radiation dose necessary for imaging. The addition of computationally generated noise to the CT images facilitates dose reduction. The objective of this study was to develop a noise addition method that reproduces the co...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Radiological physics and technology 2024-03, Vol.17 (1), p.112-123
Hauptverfasser: Gibson, Nicholas Mark, Lee, Amy, Bencsik, Martin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 123
container_issue 1
container_start_page 112
container_title Radiological physics and technology
container_volume 17
creator Gibson, Nicholas Mark
Lee, Amy
Bencsik, Martin
description Computed tomography (CT) scanning protocols should be optimized to minimize the radiation dose necessary for imaging. The addition of computationally generated noise to the CT images facilitates dose reduction. The objective of this study was to develop a noise addition method that reproduces the complexity of the noise texture present in clinical images with directionality that varies over images according to the underlying anatomy, requiring only Digital Imaging and Communications in Medicine (DICOM) images as input data and commonly available phantoms for calibration. The developed method is based on the estimation of projection data by forward projection from images, the addition of Poisson noise, and the reconstruction of new images. The method was validated by applying it to images acquired from cylindrical and thoracic phantoms using source images with exposures up to 49 mAs and target images between 39 and 5 mAs. 2D noise spectra were derived for regions of interest in the generated low-dose images and compared with those from the scanner-acquired low-dose images. The root mean square difference between the standard deviations of noise was 4%, except for very low exposures in peripheral regions of the cylindrical phantom. The noise spectra from the corresponding regions of interest exhibited remarkable agreement, indicating that the complex nature of the noise was reproduced. A practical method for adding noise to CT images was presented, and the magnitudes of noise and spectral content were validated. This method may be used to optimize CT imaging.
doi_str_mv 10.1007/s12194-023-00755-w
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2889588209</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2889588209</sourcerecordid><originalsourceid>FETCH-LOGICAL-c375t-90840c59405f16e6e88a1203745395e5d0791e07e1f2fb979fe4fafc6d4ebea43</originalsourceid><addsrcrecordid>eNp9kU1P3DAQhq2qqFDgD_RQWeqFS8AfcWIf0aqllZC4LGfLa4-XoCRObaew_74Ou6USB04zo3nmndG8CH2h5JIS0l4lyqiqK8J4VUohqqcP6ITKRlSE1_Tja875Mfqc0iMhDWWMfULHvFVCSKpO0J9rPEVjc2dNjwfID8HhHHDqhrk3GXAE03eptEvmZguugucppDkCXq1xN5gtJLzZ4fwA2DjX5S6MOHhswzDN2Syl6fsd3sIIsQg6PIYuwRk68qZPcH6Ip-j-x_f16md1e3fza3V9W1neilwpImtihaqJ8LSBBqQ0lBHe1oIrAcKRVlEgLVDP_Ea1ykPtjbeNq2EDpuan6GKvO8Xwe4aU9dAlC31vRghz0kxKJaRkRBX02xv0McyxXF8oxfnyRrkIsj1lY0gpgtdTLF-IO02JXlzRe1d0cUW_uKKfytDXg_S8GcC9jvyzoQB8D6TSGrcQ_-9-R_YvcXqZeQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2933033384</pqid></control><display><type>article</type><title>A practical method to simulate realistic reduced-exposure CT images by the addition of computationally generated noise</title><source>Springer Nature - Complete Springer Journals</source><creator>Gibson, Nicholas Mark ; Lee, Amy ; Bencsik, Martin</creator><creatorcontrib>Gibson, Nicholas Mark ; Lee, Amy ; Bencsik, Martin</creatorcontrib><description>Computed tomography (CT) scanning protocols should be optimized to minimize the radiation dose necessary for imaging. The addition of computationally generated noise to the CT images facilitates dose reduction. The objective of this study was to develop a noise addition method that reproduces the complexity of the noise texture present in clinical images with directionality that varies over images according to the underlying anatomy, requiring only Digital Imaging and Communications in Medicine (DICOM) images as input data and commonly available phantoms for calibration. The developed method is based on the estimation of projection data by forward projection from images, the addition of Poisson noise, and the reconstruction of new images. The method was validated by applying it to images acquired from cylindrical and thoracic phantoms using source images with exposures up to 49 mAs and target images between 39 and 5 mAs. 2D noise spectra were derived for regions of interest in the generated low-dose images and compared with those from the scanner-acquired low-dose images. The root mean square difference between the standard deviations of noise was 4%, except for very low exposures in peripheral regions of the cylindrical phantom. The noise spectra from the corresponding regions of interest exhibited remarkable agreement, indicating that the complex nature of the noise was reproduced. A practical method for adding noise to CT images was presented, and the magnitudes of noise and spectral content were validated. This method may be used to optimize CT imaging.</description><identifier>ISSN: 1865-0333</identifier><identifier>EISSN: 1865-0341</identifier><identifier>DOI: 10.1007/s12194-023-00755-w</identifier><identifier>PMID: 37955819</identifier><language>eng</language><publisher>Singapore: Springer Nature Singapore</publisher><subject>Complexity ; Computed tomography ; Digital imaging ; Exposure ; Image acquisition ; Image reconstruction ; Imaging ; Medical and Radiation Physics ; Medical imaging ; Medicine ; Medicine &amp; Public Health ; Noise spectra ; Nuclear Medicine ; Radiation dosage ; Radiology ; Radiotherapy ; Research Article</subject><ispartof>Radiological physics and technology, 2024-03, Vol.17 (1), p.112-123</ispartof><rights>Crown 2023</rights><rights>2023. Crown.</rights><rights>Crown 2023.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c375t-90840c59405f16e6e88a1203745395e5d0791e07e1f2fb979fe4fafc6d4ebea43</citedby><cites>FETCH-LOGICAL-c375t-90840c59405f16e6e88a1203745395e5d0791e07e1f2fb979fe4fafc6d4ebea43</cites><orcidid>0000-0003-2973-4537 ; 0000-0002-1405-1912 ; 0000-0002-6278-0378</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s12194-023-00755-w$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s12194-023-00755-w$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,27915,27916,41479,42548,51310</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/37955819$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Gibson, Nicholas Mark</creatorcontrib><creatorcontrib>Lee, Amy</creatorcontrib><creatorcontrib>Bencsik, Martin</creatorcontrib><title>A practical method to simulate realistic reduced-exposure CT images by the addition of computationally generated noise</title><title>Radiological physics and technology</title><addtitle>Radiol Phys Technol</addtitle><addtitle>Radiol Phys Technol</addtitle><description>Computed tomography (CT) scanning protocols should be optimized to minimize the radiation dose necessary for imaging. The addition of computationally generated noise to the CT images facilitates dose reduction. The objective of this study was to develop a noise addition method that reproduces the complexity of the noise texture present in clinical images with directionality that varies over images according to the underlying anatomy, requiring only Digital Imaging and Communications in Medicine (DICOM) images as input data and commonly available phantoms for calibration. The developed method is based on the estimation of projection data by forward projection from images, the addition of Poisson noise, and the reconstruction of new images. The method was validated by applying it to images acquired from cylindrical and thoracic phantoms using source images with exposures up to 49 mAs and target images between 39 and 5 mAs. 2D noise spectra were derived for regions of interest in the generated low-dose images and compared with those from the scanner-acquired low-dose images. The root mean square difference between the standard deviations of noise was 4%, except for very low exposures in peripheral regions of the cylindrical phantom. The noise spectra from the corresponding regions of interest exhibited remarkable agreement, indicating that the complex nature of the noise was reproduced. A practical method for adding noise to CT images was presented, and the magnitudes of noise and spectral content were validated. This method may be used to optimize CT imaging.</description><subject>Complexity</subject><subject>Computed tomography</subject><subject>Digital imaging</subject><subject>Exposure</subject><subject>Image acquisition</subject><subject>Image reconstruction</subject><subject>Imaging</subject><subject>Medical and Radiation Physics</subject><subject>Medical imaging</subject><subject>Medicine</subject><subject>Medicine &amp; Public Health</subject><subject>Noise spectra</subject><subject>Nuclear Medicine</subject><subject>Radiation dosage</subject><subject>Radiology</subject><subject>Radiotherapy</subject><subject>Research Article</subject><issn>1865-0333</issn><issn>1865-0341</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kU1P3DAQhq2qqFDgD_RQWeqFS8AfcWIf0aqllZC4LGfLa4-XoCRObaew_74Ou6USB04zo3nmndG8CH2h5JIS0l4lyqiqK8J4VUohqqcP6ITKRlSE1_Tja875Mfqc0iMhDWWMfULHvFVCSKpO0J9rPEVjc2dNjwfID8HhHHDqhrk3GXAE03eptEvmZguugucppDkCXq1xN5gtJLzZ4fwA2DjX5S6MOHhswzDN2Syl6fsd3sIIsQg6PIYuwRk68qZPcH6Ip-j-x_f16md1e3fza3V9W1neilwpImtihaqJ8LSBBqQ0lBHe1oIrAcKRVlEgLVDP_Ea1ykPtjbeNq2EDpuan6GKvO8Xwe4aU9dAlC31vRghz0kxKJaRkRBX02xv0McyxXF8oxfnyRrkIsj1lY0gpgtdTLF-IO02JXlzRe1d0cUW_uKKfytDXg_S8GcC9jvyzoQB8D6TSGrcQ_-9-R_YvcXqZeQ</recordid><startdate>20240301</startdate><enddate>20240301</enddate><creator>Gibson, Nicholas Mark</creator><creator>Lee, Amy</creator><creator>Bencsik, Martin</creator><general>Springer Nature Singapore</general><general>Springer Nature B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-2973-4537</orcidid><orcidid>https://orcid.org/0000-0002-1405-1912</orcidid><orcidid>https://orcid.org/0000-0002-6278-0378</orcidid></search><sort><creationdate>20240301</creationdate><title>A practical method to simulate realistic reduced-exposure CT images by the addition of computationally generated noise</title><author>Gibson, Nicholas Mark ; Lee, Amy ; Bencsik, Martin</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c375t-90840c59405f16e6e88a1203745395e5d0791e07e1f2fb979fe4fafc6d4ebea43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Complexity</topic><topic>Computed tomography</topic><topic>Digital imaging</topic><topic>Exposure</topic><topic>Image acquisition</topic><topic>Image reconstruction</topic><topic>Imaging</topic><topic>Medical and Radiation Physics</topic><topic>Medical imaging</topic><topic>Medicine</topic><topic>Medicine &amp; Public Health</topic><topic>Noise spectra</topic><topic>Nuclear Medicine</topic><topic>Radiation dosage</topic><topic>Radiology</topic><topic>Radiotherapy</topic><topic>Research Article</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gibson, Nicholas Mark</creatorcontrib><creatorcontrib>Lee, Amy</creatorcontrib><creatorcontrib>Bencsik, Martin</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Radiological physics and technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gibson, Nicholas Mark</au><au>Lee, Amy</au><au>Bencsik, Martin</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A practical method to simulate realistic reduced-exposure CT images by the addition of computationally generated noise</atitle><jtitle>Radiological physics and technology</jtitle><stitle>Radiol Phys Technol</stitle><addtitle>Radiol Phys Technol</addtitle><date>2024-03-01</date><risdate>2024</risdate><volume>17</volume><issue>1</issue><spage>112</spage><epage>123</epage><pages>112-123</pages><issn>1865-0333</issn><eissn>1865-0341</eissn><abstract>Computed tomography (CT) scanning protocols should be optimized to minimize the radiation dose necessary for imaging. The addition of computationally generated noise to the CT images facilitates dose reduction. The objective of this study was to develop a noise addition method that reproduces the complexity of the noise texture present in clinical images with directionality that varies over images according to the underlying anatomy, requiring only Digital Imaging and Communications in Medicine (DICOM) images as input data and commonly available phantoms for calibration. The developed method is based on the estimation of projection data by forward projection from images, the addition of Poisson noise, and the reconstruction of new images. The method was validated by applying it to images acquired from cylindrical and thoracic phantoms using source images with exposures up to 49 mAs and target images between 39 and 5 mAs. 2D noise spectra were derived for regions of interest in the generated low-dose images and compared with those from the scanner-acquired low-dose images. The root mean square difference between the standard deviations of noise was 4%, except for very low exposures in peripheral regions of the cylindrical phantom. The noise spectra from the corresponding regions of interest exhibited remarkable agreement, indicating that the complex nature of the noise was reproduced. A practical method for adding noise to CT images was presented, and the magnitudes of noise and spectral content were validated. This method may be used to optimize CT imaging.</abstract><cop>Singapore</cop><pub>Springer Nature Singapore</pub><pmid>37955819</pmid><doi>10.1007/s12194-023-00755-w</doi><tpages>12</tpages><orcidid>https://orcid.org/0000-0003-2973-4537</orcidid><orcidid>https://orcid.org/0000-0002-1405-1912</orcidid><orcidid>https://orcid.org/0000-0002-6278-0378</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1865-0333
ispartof Radiological physics and technology, 2024-03, Vol.17 (1), p.112-123
issn 1865-0333
1865-0341
language eng
recordid cdi_proquest_miscellaneous_2889588209
source Springer Nature - Complete Springer Journals
subjects Complexity
Computed tomography
Digital imaging
Exposure
Image acquisition
Image reconstruction
Imaging
Medical and Radiation Physics
Medical imaging
Medicine
Medicine & Public Health
Noise spectra
Nuclear Medicine
Radiation dosage
Radiology
Radiotherapy
Research Article
title A practical method to simulate realistic reduced-exposure CT images by the addition of computationally generated noise
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T06%3A08%3A20IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20practical%20method%20to%20simulate%20realistic%20reduced-exposure%20CT%20images%20by%20the%20addition%20of%20computationally%20generated%20noise&rft.jtitle=Radiological%20physics%20and%20technology&rft.au=Gibson,%20Nicholas%20Mark&rft.date=2024-03-01&rft.volume=17&rft.issue=1&rft.spage=112&rft.epage=123&rft.pages=112-123&rft.issn=1865-0333&rft.eissn=1865-0341&rft_id=info:doi/10.1007/s12194-023-00755-w&rft_dat=%3Cproquest_cross%3E2889588209%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2933033384&rft_id=info:pmid/37955819&rfr_iscdi=true