The influence of pH and salt concentration on the microstructure and mechanical properties of meniscus extracellular matrix‐derived implants

Meniscus‐related injuries are a common orthopedic challenge with an increasing incidence in the population. While the preservation of viable meniscal tissue is the preferred approach in repair strategies, complex or total traumatic lesions may require alternative therapeutic approaches such as menis...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of biomedical materials research. Part A 2024-03, Vol.112 (3), p.359-372
Hauptverfasser: Salinas‐Fernandez, Soraya, Garcia, Orquidea, Kelly, Daniel J., Buckley, Conor T.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 372
container_issue 3
container_start_page 359
container_title Journal of biomedical materials research. Part A
container_volume 112
creator Salinas‐Fernandez, Soraya
Garcia, Orquidea
Kelly, Daniel J.
Buckley, Conor T.
description Meniscus‐related injuries are a common orthopedic challenge with an increasing incidence in the population. While the preservation of viable meniscal tissue is the preferred approach in repair strategies, complex or total traumatic lesions may require alternative therapeutic approaches such as meniscal reconstruction using allografts or engineered equivalents. Although clinical studies suggest promising outcomes with the use of acellular implants, further development is needed to improve their biological and mechanical requirements. Decellularized extracellular matrix (dECM) derived from menisci is a promising biomaterial for meniscus tissue engineering due to its recapitulation of the native tissue environment and the maintenance of tissue‐specific cues. However, the associated mechanical limitations of dECM‐derived scaffolds frequently impedes their adoption, requiring additional reinforcement or combining with stiffer biomaterials to increase their load‐bearing properties. In this study, decellularized extracellular matrix was extracted and its fibrillation was controlled by adjusting both pH and salt concentrations to fabricate mechanically functional meniscal tissue equivalents. The effect of collagen fibrillation on the mechanical properties of the dECM constructs was assessed, and porcine‐derived fibrochondrocytes were used to evaluate in vitro biocompatibility. It was also possible to fabricate meniscus‐shaped implants by casting of the dECM and to render the implants suitable for off‐the‐shelf use by adopting a freeze‐drying preservation method. Suture pull‐out tests were also performed to assess the feasibility of using existing surgical methods to fix such implants within a damaged meniscus. This study highlights the potential of utilizing ECM‐derived materials for meniscal tissue substitutes that closely mimic the mechanical and biological properties of native tissue.
doi_str_mv 10.1002/jbm.a.37634
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2886326624</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2886326624</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3554-a44d3125dca003c2e62065910f1a9f1da7633fc715fd45bdeeeb87d42c044b5f3</originalsourceid><addsrcrecordid>eNp9kU1rFTEUhgex2FpduZeAm4LMNd_3zrIWtZaKm7oOmeSE5pJkxiRj252_QPyN_hJze6sLF8KBHMLDw8t5u-4FwSuCMX2zHeNKr9haMv6oOyJC0J4PUjze7XzoGR3kYfe0lG2DJRb0SXfI1gMlFLOj7sfVNSCfXFggGUCTQ_M50smiokNFZmqfqWZd_ZRQm9ro6E2eSs2LqUuGeziCudbJGx3QnKcZcvVQdrIIyRezFAS3zWIghCXojKKu2d_--v7TQvbfwCIf56BTLc-6A6dDgecP73H35f27q7Pz_vLzh49np5e9YULwXnNuGaHCGo0xMxQkxVIMBDuiB0esbsdgzqyJcJaL0QLAuFlbTg3mfBSOHXcne2-L-3WBUlVsOVs8nWBaiqKbjWRUSsob-uofdDstObV0ig5EsgZy2ajXe2p3m5LBqTn7qPOdIljtalKtJqXVfU2NfvngXMYI9i_7p5cG0D1w4wPc_c-lLt5-Ot1bfwNVIaGF</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2916386346</pqid></control><display><type>article</type><title>The influence of pH and salt concentration on the microstructure and mechanical properties of meniscus extracellular matrix‐derived implants</title><source>Wiley Online Library Journals Frontfile Complete</source><creator>Salinas‐Fernandez, Soraya ; Garcia, Orquidea ; Kelly, Daniel J. ; Buckley, Conor T.</creator><creatorcontrib>Salinas‐Fernandez, Soraya ; Garcia, Orquidea ; Kelly, Daniel J. ; Buckley, Conor T.</creatorcontrib><description>Meniscus‐related injuries are a common orthopedic challenge with an increasing incidence in the population. While the preservation of viable meniscal tissue is the preferred approach in repair strategies, complex or total traumatic lesions may require alternative therapeutic approaches such as meniscal reconstruction using allografts or engineered equivalents. Although clinical studies suggest promising outcomes with the use of acellular implants, further development is needed to improve their biological and mechanical requirements. Decellularized extracellular matrix (dECM) derived from menisci is a promising biomaterial for meniscus tissue engineering due to its recapitulation of the native tissue environment and the maintenance of tissue‐specific cues. However, the associated mechanical limitations of dECM‐derived scaffolds frequently impedes their adoption, requiring additional reinforcement or combining with stiffer biomaterials to increase their load‐bearing properties. In this study, decellularized extracellular matrix was extracted and its fibrillation was controlled by adjusting both pH and salt concentrations to fabricate mechanically functional meniscal tissue equivalents. The effect of collagen fibrillation on the mechanical properties of the dECM constructs was assessed, and porcine‐derived fibrochondrocytes were used to evaluate in vitro biocompatibility. It was also possible to fabricate meniscus‐shaped implants by casting of the dECM and to render the implants suitable for off‐the‐shelf use by adopting a freeze‐drying preservation method. Suture pull‐out tests were also performed to assess the feasibility of using existing surgical methods to fix such implants within a damaged meniscus. This study highlights the potential of utilizing ECM‐derived materials for meniscal tissue substitutes that closely mimic the mechanical and biological properties of native tissue.</description><identifier>ISSN: 1549-3296</identifier><identifier>EISSN: 1552-4965</identifier><identifier>DOI: 10.1002/jbm.a.37634</identifier><identifier>PMID: 37921203</identifier><language>eng</language><publisher>Hoboken, USA: John Wiley &amp; Sons, Inc</publisher><subject>Biocompatibility ; biofabrication ; Biological properties ; Biomaterials ; Biomedical materials ; ECM ; Equivalence ; Extracellular matrix ; Fibrillation ; Freeze drying ; Mechanical properties ; Meniscus ; Orthopedics ; Preservation ; Pull out tests ; salt ; Surgical implants ; Tissue engineering</subject><ispartof>Journal of biomedical materials research. Part A, 2024-03, Vol.112 (3), p.359-372</ispartof><rights>2023 The Authors. published by Wiley Periodicals LLC.</rights><rights>2023 The Authors. Journal of Biomedical Materials Research Part A published by Wiley Periodicals LLC.</rights><rights>2023. This article is published under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c3554-a44d3125dca003c2e62065910f1a9f1da7633fc715fd45bdeeeb87d42c044b5f3</cites><orcidid>0000-0001-7452-4534</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fjbm.a.37634$$EPDF$$P50$$Gwiley$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fjbm.a.37634$$EHTML$$P50$$Gwiley$$Hfree_for_read</linktohtml><link.rule.ids>314,776,780,1411,27903,27904,45553,45554</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/37921203$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Salinas‐Fernandez, Soraya</creatorcontrib><creatorcontrib>Garcia, Orquidea</creatorcontrib><creatorcontrib>Kelly, Daniel J.</creatorcontrib><creatorcontrib>Buckley, Conor T.</creatorcontrib><title>The influence of pH and salt concentration on the microstructure and mechanical properties of meniscus extracellular matrix‐derived implants</title><title>Journal of biomedical materials research. Part A</title><addtitle>J Biomed Mater Res A</addtitle><description>Meniscus‐related injuries are a common orthopedic challenge with an increasing incidence in the population. While the preservation of viable meniscal tissue is the preferred approach in repair strategies, complex or total traumatic lesions may require alternative therapeutic approaches such as meniscal reconstruction using allografts or engineered equivalents. Although clinical studies suggest promising outcomes with the use of acellular implants, further development is needed to improve their biological and mechanical requirements. Decellularized extracellular matrix (dECM) derived from menisci is a promising biomaterial for meniscus tissue engineering due to its recapitulation of the native tissue environment and the maintenance of tissue‐specific cues. However, the associated mechanical limitations of dECM‐derived scaffolds frequently impedes their adoption, requiring additional reinforcement or combining with stiffer biomaterials to increase their load‐bearing properties. In this study, decellularized extracellular matrix was extracted and its fibrillation was controlled by adjusting both pH and salt concentrations to fabricate mechanically functional meniscal tissue equivalents. The effect of collagen fibrillation on the mechanical properties of the dECM constructs was assessed, and porcine‐derived fibrochondrocytes were used to evaluate in vitro biocompatibility. It was also possible to fabricate meniscus‐shaped implants by casting of the dECM and to render the implants suitable for off‐the‐shelf use by adopting a freeze‐drying preservation method. Suture pull‐out tests were also performed to assess the feasibility of using existing surgical methods to fix such implants within a damaged meniscus. This study highlights the potential of utilizing ECM‐derived materials for meniscal tissue substitutes that closely mimic the mechanical and biological properties of native tissue.</description><subject>Biocompatibility</subject><subject>biofabrication</subject><subject>Biological properties</subject><subject>Biomaterials</subject><subject>Biomedical materials</subject><subject>ECM</subject><subject>Equivalence</subject><subject>Extracellular matrix</subject><subject>Fibrillation</subject><subject>Freeze drying</subject><subject>Mechanical properties</subject><subject>Meniscus</subject><subject>Orthopedics</subject><subject>Preservation</subject><subject>Pull out tests</subject><subject>salt</subject><subject>Surgical implants</subject><subject>Tissue engineering</subject><issn>1549-3296</issn><issn>1552-4965</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>24P</sourceid><recordid>eNp9kU1rFTEUhgex2FpduZeAm4LMNd_3zrIWtZaKm7oOmeSE5pJkxiRj252_QPyN_hJze6sLF8KBHMLDw8t5u-4FwSuCMX2zHeNKr9haMv6oOyJC0J4PUjze7XzoGR3kYfe0lG2DJRb0SXfI1gMlFLOj7sfVNSCfXFggGUCTQ_M50smiokNFZmqfqWZd_ZRQm9ro6E2eSs2LqUuGeziCudbJGx3QnKcZcvVQdrIIyRezFAS3zWIghCXojKKu2d_--v7TQvbfwCIf56BTLc-6A6dDgecP73H35f27q7Pz_vLzh49np5e9YULwXnNuGaHCGo0xMxQkxVIMBDuiB0esbsdgzqyJcJaL0QLAuFlbTg3mfBSOHXcne2-L-3WBUlVsOVs8nWBaiqKbjWRUSsob-uofdDstObV0ig5EsgZy2ajXe2p3m5LBqTn7qPOdIljtalKtJqXVfU2NfvngXMYI9i_7p5cG0D1w4wPc_c-lLt5-Ot1bfwNVIaGF</recordid><startdate>202403</startdate><enddate>202403</enddate><creator>Salinas‐Fernandez, Soraya</creator><creator>Garcia, Orquidea</creator><creator>Kelly, Daniel J.</creator><creator>Buckley, Conor T.</creator><general>John Wiley &amp; Sons, Inc</general><general>Wiley Subscription Services, Inc</general><scope>24P</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>JG9</scope><scope>JQ2</scope><scope>K9.</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-7452-4534</orcidid></search><sort><creationdate>202403</creationdate><title>The influence of pH and salt concentration on the microstructure and mechanical properties of meniscus extracellular matrix‐derived implants</title><author>Salinas‐Fernandez, Soraya ; Garcia, Orquidea ; Kelly, Daniel J. ; Buckley, Conor T.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3554-a44d3125dca003c2e62065910f1a9f1da7633fc715fd45bdeeeb87d42c044b5f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Biocompatibility</topic><topic>biofabrication</topic><topic>Biological properties</topic><topic>Biomaterials</topic><topic>Biomedical materials</topic><topic>ECM</topic><topic>Equivalence</topic><topic>Extracellular matrix</topic><topic>Fibrillation</topic><topic>Freeze drying</topic><topic>Mechanical properties</topic><topic>Meniscus</topic><topic>Orthopedics</topic><topic>Preservation</topic><topic>Pull out tests</topic><topic>salt</topic><topic>Surgical implants</topic><topic>Tissue engineering</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Salinas‐Fernandez, Soraya</creatorcontrib><creatorcontrib>Garcia, Orquidea</creatorcontrib><creatorcontrib>Kelly, Daniel J.</creatorcontrib><creatorcontrib>Buckley, Conor T.</creatorcontrib><collection>Wiley Online Library Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of biomedical materials research. Part A</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Salinas‐Fernandez, Soraya</au><au>Garcia, Orquidea</au><au>Kelly, Daniel J.</au><au>Buckley, Conor T.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The influence of pH and salt concentration on the microstructure and mechanical properties of meniscus extracellular matrix‐derived implants</atitle><jtitle>Journal of biomedical materials research. Part A</jtitle><addtitle>J Biomed Mater Res A</addtitle><date>2024-03</date><risdate>2024</risdate><volume>112</volume><issue>3</issue><spage>359</spage><epage>372</epage><pages>359-372</pages><issn>1549-3296</issn><eissn>1552-4965</eissn><abstract>Meniscus‐related injuries are a common orthopedic challenge with an increasing incidence in the population. While the preservation of viable meniscal tissue is the preferred approach in repair strategies, complex or total traumatic lesions may require alternative therapeutic approaches such as meniscal reconstruction using allografts or engineered equivalents. Although clinical studies suggest promising outcomes with the use of acellular implants, further development is needed to improve their biological and mechanical requirements. Decellularized extracellular matrix (dECM) derived from menisci is a promising biomaterial for meniscus tissue engineering due to its recapitulation of the native tissue environment and the maintenance of tissue‐specific cues. However, the associated mechanical limitations of dECM‐derived scaffolds frequently impedes their adoption, requiring additional reinforcement or combining with stiffer biomaterials to increase their load‐bearing properties. In this study, decellularized extracellular matrix was extracted and its fibrillation was controlled by adjusting both pH and salt concentrations to fabricate mechanically functional meniscal tissue equivalents. The effect of collagen fibrillation on the mechanical properties of the dECM constructs was assessed, and porcine‐derived fibrochondrocytes were used to evaluate in vitro biocompatibility. It was also possible to fabricate meniscus‐shaped implants by casting of the dECM and to render the implants suitable for off‐the‐shelf use by adopting a freeze‐drying preservation method. Suture pull‐out tests were also performed to assess the feasibility of using existing surgical methods to fix such implants within a damaged meniscus. This study highlights the potential of utilizing ECM‐derived materials for meniscal tissue substitutes that closely mimic the mechanical and biological properties of native tissue.</abstract><cop>Hoboken, USA</cop><pub>John Wiley &amp; Sons, Inc</pub><pmid>37921203</pmid><doi>10.1002/jbm.a.37634</doi><tpages>14</tpages><orcidid>https://orcid.org/0000-0001-7452-4534</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1549-3296
ispartof Journal of biomedical materials research. Part A, 2024-03, Vol.112 (3), p.359-372
issn 1549-3296
1552-4965
language eng
recordid cdi_proquest_miscellaneous_2886326624
source Wiley Online Library Journals Frontfile Complete
subjects Biocompatibility
biofabrication
Biological properties
Biomaterials
Biomedical materials
ECM
Equivalence
Extracellular matrix
Fibrillation
Freeze drying
Mechanical properties
Meniscus
Orthopedics
Preservation
Pull out tests
salt
Surgical implants
Tissue engineering
title The influence of pH and salt concentration on the microstructure and mechanical properties of meniscus extracellular matrix‐derived implants
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T12%3A47%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20influence%20of%20pH%20and%20salt%20concentration%20on%20the%20microstructure%20and%20mechanical%20properties%20of%20meniscus%20extracellular%20matrix%E2%80%90derived%20implants&rft.jtitle=Journal%20of%20biomedical%20materials%20research.%20Part%20A&rft.au=Salinas%E2%80%90Fernandez,%20Soraya&rft.date=2024-03&rft.volume=112&rft.issue=3&rft.spage=359&rft.epage=372&rft.pages=359-372&rft.issn=1549-3296&rft.eissn=1552-4965&rft_id=info:doi/10.1002/jbm.a.37634&rft_dat=%3Cproquest_cross%3E2886326624%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2916386346&rft_id=info:pmid/37921203&rfr_iscdi=true