Analysis of a UV photocatalytic oxidation-based disinfection system for hydroxyl radicals, negative air ions generation and their impact on inactivation of pathogenic micro-organisms
This work presents a large-scale surface disinfection system, which has a unique lantern arrangement of ultraviolet-C (UV-C) light (254 nm) in conjunction with nanotechnology in a protective biosafety environment. Shadow regions are best dealt in this system by the generation of hydroxyl radicals (•...
Gespeichert in:
Veröffentlicht in: | Review of scientific instruments 2023-10, Vol.94 (10) |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 10 |
container_start_page | |
container_title | Review of scientific instruments |
container_volume | 94 |
creator | Ahlawat, Kiran Jangra, Ramavtar Ish, Ambar Dixit, Ambesh Fulwani, Deepak Jain, Neha Prakash, Ram |
description | This work presents a large-scale surface disinfection system, which has a unique lantern arrangement of ultraviolet-C (UV-C) light (254 nm) in conjunction with nanotechnology in a protective biosafety environment. Shadow regions are best dealt in this system by the generation of hydroxyl radicals (•OH) and negative air ions at sites where UV light cannot penetrate. More than 35 000 negative air ions/cm3 along with •OH were produced continuously in the disinfection chamber through the advanced photocatalytic oxidation process [UV-C + titanium dioxide (TiO2)]. The arrangement has been made to provide an optimized UV irradiation (∼2 mW/cm2) throughout the disinfection system. In order to distinguish between effects arising from (i) the action of UV dose alone and (ii) the action of UV dose along with •OH and negative air ions, E. coli and P. aeruginosa were chosen for bacterial testing and two interventions were made. The first intervention involved placing only UV lamps in the disinfection chamber to see the effect of only UV dose on bacterial inactivation efficiency. The second intervention involved placing the TiO2 nanoparticle coated aluminum plates along with UV lamps; this allows for the generation of negative air ions and •OH inside the disinfection chamber and enhanced bacterial inactivation efficiency. More than 95% bacterial inactivation efficiency has been reported in the case of UV-C + TiO2 compared to only 77% in UV only at the same time interval (90 s). |
doi_str_mv | 10.1063/5.0151619 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2884184952</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2884184952</sourcerecordid><originalsourceid>FETCH-LOGICAL-c325t-509a8f1a67c7cad6db9e42513642b7e636f45a79932b5268ce687236aa0dfea23</originalsourceid><addsrcrecordid>eNp9kbtuFDEUhi0EEkug4A0s0QBigu9jl1EULlIkGkI7Omt7dh3N2IPtjTIvxvPh3U1FgZtj_ec7d4TeUnJJieKf5SWhkipqnqENJdp0vWL8OdoQwkWneqFfolel3JP2JKUb9OcqwrSWUHAaMeC7X3jZp5os1CbXYHF6DA5qSLHbQvEOu1BCHL09SrispfoZjynj_epyelwnnMEFC1P5hKPftcgHjyFk3PCCdz76fMqGITpc9_7omRewFTctxPYJD2eg9bNA3acW09qYg82pS3kHMZS5vEYvxlbDv3myF-juy83P62_d7Y-v36-vbjvLmaydJAb0SEH1trfglNsaL5ikXAm27b3iahQSemM420qmtPVK94wrAOJGD4xfoPfnvEtOvw--1GEOxfppgujToQxMa0G1MPKIvvsHvU-H3LZ7orgRQkvTqA9nqo1TSvbjsOQwQ14HSobjBQc5PF2wsR_PbLGhnpbyH_gvxz2e_w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2883944859</pqid></control><display><type>article</type><title>Analysis of a UV photocatalytic oxidation-based disinfection system for hydroxyl radicals, negative air ions generation and their impact on inactivation of pathogenic micro-organisms</title><source>AIP Journals Complete</source><source>Alma/SFX Local Collection</source><creator>Ahlawat, Kiran ; Jangra, Ramavtar ; Ish, Ambar ; Dixit, Ambesh ; Fulwani, Deepak ; Jain, Neha ; Prakash, Ram</creator><creatorcontrib>Ahlawat, Kiran ; Jangra, Ramavtar ; Ish, Ambar ; Dixit, Ambesh ; Fulwani, Deepak ; Jain, Neha ; Prakash, Ram</creatorcontrib><description>This work presents a large-scale surface disinfection system, which has a unique lantern arrangement of ultraviolet-C (UV-C) light (254 nm) in conjunction with nanotechnology in a protective biosafety environment. Shadow regions are best dealt in this system by the generation of hydroxyl radicals (•OH) and negative air ions at sites where UV light cannot penetrate. More than 35 000 negative air ions/cm3 along with •OH were produced continuously in the disinfection chamber through the advanced photocatalytic oxidation process [UV-C + titanium dioxide (TiO2)]. The arrangement has been made to provide an optimized UV irradiation (∼2 mW/cm2) throughout the disinfection system. In order to distinguish between effects arising from (i) the action of UV dose alone and (ii) the action of UV dose along with •OH and negative air ions, E. coli and P. aeruginosa were chosen for bacterial testing and two interventions were made. The first intervention involved placing only UV lamps in the disinfection chamber to see the effect of only UV dose on bacterial inactivation efficiency. The second intervention involved placing the TiO2 nanoparticle coated aluminum plates along with UV lamps; this allows for the generation of negative air ions and •OH inside the disinfection chamber and enhanced bacterial inactivation efficiency. More than 95% bacterial inactivation efficiency has been reported in the case of UV-C + TiO2 compared to only 77% in UV only at the same time interval (90 s).</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/5.0151619</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>Chambers ; Deactivation ; Disinfection ; E coli ; Efficiency ; Hydroxyl radicals ; Lamps ; Metal plates ; Nanoparticles ; Oxidation ; Photocatalysis ; Scientific apparatus & instruments ; Titanium dioxide ; Ultraviolet radiation</subject><ispartof>Review of scientific instruments, 2023-10, Vol.94 (10)</ispartof><rights>Author(s)</rights><rights>2023 Author(s). Published under an exclusive license by AIP Publishing.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c325t-509a8f1a67c7cad6db9e42513642b7e636f45a79932b5268ce687236aa0dfea23</citedby><cites>FETCH-LOGICAL-c325t-509a8f1a67c7cad6db9e42513642b7e636f45a79932b5268ce687236aa0dfea23</cites><orcidid>0000-0003-4108-3204 ; 0000-0002-9952-7042 ; 0000-0003-3561-6801 ; 0000-0002-1397-861X ; 0000-0003-2285-0754</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/5.0151619$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,776,780,790,4498,27901,27902,76126</link.rule.ids></links><search><creatorcontrib>Ahlawat, Kiran</creatorcontrib><creatorcontrib>Jangra, Ramavtar</creatorcontrib><creatorcontrib>Ish, Ambar</creatorcontrib><creatorcontrib>Dixit, Ambesh</creatorcontrib><creatorcontrib>Fulwani, Deepak</creatorcontrib><creatorcontrib>Jain, Neha</creatorcontrib><creatorcontrib>Prakash, Ram</creatorcontrib><title>Analysis of a UV photocatalytic oxidation-based disinfection system for hydroxyl radicals, negative air ions generation and their impact on inactivation of pathogenic micro-organisms</title><title>Review of scientific instruments</title><description>This work presents a large-scale surface disinfection system, which has a unique lantern arrangement of ultraviolet-C (UV-C) light (254 nm) in conjunction with nanotechnology in a protective biosafety environment. Shadow regions are best dealt in this system by the generation of hydroxyl radicals (•OH) and negative air ions at sites where UV light cannot penetrate. More than 35 000 negative air ions/cm3 along with •OH were produced continuously in the disinfection chamber through the advanced photocatalytic oxidation process [UV-C + titanium dioxide (TiO2)]. The arrangement has been made to provide an optimized UV irradiation (∼2 mW/cm2) throughout the disinfection system. In order to distinguish between effects arising from (i) the action of UV dose alone and (ii) the action of UV dose along with •OH and negative air ions, E. coli and P. aeruginosa were chosen for bacterial testing and two interventions were made. The first intervention involved placing only UV lamps in the disinfection chamber to see the effect of only UV dose on bacterial inactivation efficiency. The second intervention involved placing the TiO2 nanoparticle coated aluminum plates along with UV lamps; this allows for the generation of negative air ions and •OH inside the disinfection chamber and enhanced bacterial inactivation efficiency. More than 95% bacterial inactivation efficiency has been reported in the case of UV-C + TiO2 compared to only 77% in UV only at the same time interval (90 s).</description><subject>Chambers</subject><subject>Deactivation</subject><subject>Disinfection</subject><subject>E coli</subject><subject>Efficiency</subject><subject>Hydroxyl radicals</subject><subject>Lamps</subject><subject>Metal plates</subject><subject>Nanoparticles</subject><subject>Oxidation</subject><subject>Photocatalysis</subject><subject>Scientific apparatus & instruments</subject><subject>Titanium dioxide</subject><subject>Ultraviolet radiation</subject><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp9kbtuFDEUhi0EEkug4A0s0QBigu9jl1EULlIkGkI7Omt7dh3N2IPtjTIvxvPh3U1FgZtj_ec7d4TeUnJJieKf5SWhkipqnqENJdp0vWL8OdoQwkWneqFfolel3JP2JKUb9OcqwrSWUHAaMeC7X3jZp5os1CbXYHF6DA5qSLHbQvEOu1BCHL09SrispfoZjynj_epyelwnnMEFC1P5hKPftcgHjyFk3PCCdz76fMqGITpc9_7omRewFTctxPYJD2eg9bNA3acW09qYg82pS3kHMZS5vEYvxlbDv3myF-juy83P62_d7Y-v36-vbjvLmaydJAb0SEH1trfglNsaL5ikXAm27b3iahQSemM420qmtPVK94wrAOJGD4xfoPfnvEtOvw--1GEOxfppgujToQxMa0G1MPKIvvsHvU-H3LZ7orgRQkvTqA9nqo1TSvbjsOQwQ14HSobjBQc5PF2wsR_PbLGhnpbyH_gvxz2e_w</recordid><startdate>20231001</startdate><enddate>20231001</enddate><creator>Ahlawat, Kiran</creator><creator>Jangra, Ramavtar</creator><creator>Ish, Ambar</creator><creator>Dixit, Ambesh</creator><creator>Fulwani, Deepak</creator><creator>Jain, Neha</creator><creator>Prakash, Ram</creator><general>American Institute of Physics</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-4108-3204</orcidid><orcidid>https://orcid.org/0000-0002-9952-7042</orcidid><orcidid>https://orcid.org/0000-0003-3561-6801</orcidid><orcidid>https://orcid.org/0000-0002-1397-861X</orcidid><orcidid>https://orcid.org/0000-0003-2285-0754</orcidid></search><sort><creationdate>20231001</creationdate><title>Analysis of a UV photocatalytic oxidation-based disinfection system for hydroxyl radicals, negative air ions generation and their impact on inactivation of pathogenic micro-organisms</title><author>Ahlawat, Kiran ; Jangra, Ramavtar ; Ish, Ambar ; Dixit, Ambesh ; Fulwani, Deepak ; Jain, Neha ; Prakash, Ram</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c325t-509a8f1a67c7cad6db9e42513642b7e636f45a79932b5268ce687236aa0dfea23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Chambers</topic><topic>Deactivation</topic><topic>Disinfection</topic><topic>E coli</topic><topic>Efficiency</topic><topic>Hydroxyl radicals</topic><topic>Lamps</topic><topic>Metal plates</topic><topic>Nanoparticles</topic><topic>Oxidation</topic><topic>Photocatalysis</topic><topic>Scientific apparatus & instruments</topic><topic>Titanium dioxide</topic><topic>Ultraviolet radiation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ahlawat, Kiran</creatorcontrib><creatorcontrib>Jangra, Ramavtar</creatorcontrib><creatorcontrib>Ish, Ambar</creatorcontrib><creatorcontrib>Dixit, Ambesh</creatorcontrib><creatorcontrib>Fulwani, Deepak</creatorcontrib><creatorcontrib>Jain, Neha</creatorcontrib><creatorcontrib>Prakash, Ram</creatorcontrib><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ahlawat, Kiran</au><au>Jangra, Ramavtar</au><au>Ish, Ambar</au><au>Dixit, Ambesh</au><au>Fulwani, Deepak</au><au>Jain, Neha</au><au>Prakash, Ram</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Analysis of a UV photocatalytic oxidation-based disinfection system for hydroxyl radicals, negative air ions generation and their impact on inactivation of pathogenic micro-organisms</atitle><jtitle>Review of scientific instruments</jtitle><date>2023-10-01</date><risdate>2023</risdate><volume>94</volume><issue>10</issue><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>This work presents a large-scale surface disinfection system, which has a unique lantern arrangement of ultraviolet-C (UV-C) light (254 nm) in conjunction with nanotechnology in a protective biosafety environment. Shadow regions are best dealt in this system by the generation of hydroxyl radicals (•OH) and negative air ions at sites where UV light cannot penetrate. More than 35 000 negative air ions/cm3 along with •OH were produced continuously in the disinfection chamber through the advanced photocatalytic oxidation process [UV-C + titanium dioxide (TiO2)]. The arrangement has been made to provide an optimized UV irradiation (∼2 mW/cm2) throughout the disinfection system. In order to distinguish between effects arising from (i) the action of UV dose alone and (ii) the action of UV dose along with •OH and negative air ions, E. coli and P. aeruginosa were chosen for bacterial testing and two interventions were made. The first intervention involved placing only UV lamps in the disinfection chamber to see the effect of only UV dose on bacterial inactivation efficiency. The second intervention involved placing the TiO2 nanoparticle coated aluminum plates along with UV lamps; this allows for the generation of negative air ions and •OH inside the disinfection chamber and enhanced bacterial inactivation efficiency. More than 95% bacterial inactivation efficiency has been reported in the case of UV-C + TiO2 compared to only 77% in UV only at the same time interval (90 s).</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/5.0151619</doi><tpages>12</tpages><orcidid>https://orcid.org/0000-0003-4108-3204</orcidid><orcidid>https://orcid.org/0000-0002-9952-7042</orcidid><orcidid>https://orcid.org/0000-0003-3561-6801</orcidid><orcidid>https://orcid.org/0000-0002-1397-861X</orcidid><orcidid>https://orcid.org/0000-0003-2285-0754</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0034-6748 |
ispartof | Review of scientific instruments, 2023-10, Vol.94 (10) |
issn | 0034-6748 1089-7623 |
language | eng |
recordid | cdi_proquest_miscellaneous_2884184952 |
source | AIP Journals Complete; Alma/SFX Local Collection |
subjects | Chambers Deactivation Disinfection E coli Efficiency Hydroxyl radicals Lamps Metal plates Nanoparticles Oxidation Photocatalysis Scientific apparatus & instruments Titanium dioxide Ultraviolet radiation |
title | Analysis of a UV photocatalytic oxidation-based disinfection system for hydroxyl radicals, negative air ions generation and their impact on inactivation of pathogenic micro-organisms |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-13T00%3A37%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Analysis%20of%20a%20UV%20photocatalytic%20oxidation-based%20disinfection%20system%20for%20hydroxyl%20radicals,%20negative%20air%20ions%20generation%20and%20their%20impact%20on%20inactivation%20of%20pathogenic%20micro-organisms&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Ahlawat,%20Kiran&rft.date=2023-10-01&rft.volume=94&rft.issue=10&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/5.0151619&rft_dat=%3Cproquest_cross%3E2884184952%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2883944859&rft_id=info:pmid/&rfr_iscdi=true |