Development and comparison of two immunoassays for the detection of 2,4,6-trinitrotoluene (TNT) based on surface plasmon resonance
This paper describes the development and comparison of two immunoassays for the detection of 2,4,6-trinitrotoluene (TNT) based on competitive inhibition. Two polyclonal antibodies were used in the immunoassay; one was prepared from 2,4,6-trinitrophenol–bovine serum albumin conjugate (anti-TNP-BSA Ab...
Gespeichert in:
Veröffentlicht in: | Sensors and actuators. B, Chemical Chemical, 2006-03, Vol.114 (1), p.71-79 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 79 |
---|---|
container_issue | 1 |
container_start_page | 71 |
container_title | Sensors and actuators. B, Chemical |
container_volume | 114 |
creator | Shankaran, Dhesingh Ravi Matsumoto, Kiyoshi Toko, Kiyoshi Miura, Norio |
description | This paper describes the development and comparison of two immunoassays for the detection of 2,4,6-trinitrotoluene (TNT) based on competitive inhibition. Two polyclonal antibodies were used in the immunoassay; one was prepared from 2,4,6-trinitrophenol–bovine serum albumin conjugate (anti-TNP-BSA Ab, goat IgG) and another from 2,4,6-trinitrophenyl–keyhole limpet hemocyanine conjugate (anti-TNPh-KLH Ab, rabbit IgG). A solid-phase immunoassay that consisted of physically immobilized TNP-BSA conjugate was allowed to interact with these antibodies and the resonance angle changes due to the biomolecular interactions were monitored by surface plasmon resonance (SPR). The quantification of TNT was based on the change in the resonance angle shift for binding of antibodies with a TNP-BSA conjugate, which occurred in the presence of TNT in solution. Both antibodies showed a high degree of affinity for TNT and varying degrees of cross-reactivity to the related nitroaromatic derivative compounds, such as 2,4-dinitrotoluene (DNT), 1,3-dinitrobenzene (DNB), 2-amino-4,6-dintitrotoluene (2A-4,6-DNT), 4-amino-2,6-dinitrotoluene (4A-2,6-DNT) and TNP. The anti-TNPh-KLH Ab prepared in our laboratory showed a detection limit of 0.006
ng/ml (6
ppt), which was comparable to or even better than the detection limit (0.095
ng/ml or 95
ppt) of a commercially available anti-TNP-BSA Ab for detection of TNT. A pepsin solution prepared with a glycine–HCl buffer (pH 2.0) was used for regeneration of the sensor surface. The duration for a single immunocycle was ∼19 and ∼13
min for anti-TNP-BSA Ab and anti-TNPh-KLH Ab immunosystems, respectively. The proposed immunoassay is simple and possesses good analytical characteristics for quantification of TNT. |
doi_str_mv | 10.1016/j.snb.2005.04.013 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_28835591</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0925400505004272</els_id><sourcerecordid>19429556</sourcerecordid><originalsourceid>FETCH-LOGICAL-c425t-64394f2c6a4a65a45d59554c2796a6cab1ce28ce6a2380bc075b00523fe0fab63</originalsourceid><addsrcrecordid>eNqFUcuO1DAQtBBIDAsfwM0nBNIm-J1EnNDylFZwGc5Wx-kIjxI72M6u9sqX49FwhlOr1VXVqipCXnLWcsbN21Obw9gKxnTLVMu4fEQOvO9kI1nXPSYHNgjdqHp-Sp7lfGKMKWnYgfz-gHe4xG3FUCiEibq4bpB8joHGmZb7SP267iFCzvCQ6RwTLT-RTljQFX9BiWt1bZqSfPAlxRKXHQPS18dvxzd0hIwTrbi8pxkc0m2BvNY9Yf0BweFz8mSGJeOLv_OK_Pj08Xjzpbn9_vnrzfvbximhS2OUHNQsnAEFRoPSkx60Vk50gwHjYOQORe_QgJA9Gx3r9Fj9Cjkjm2E08oq8uuhuKf7aMRe7-uxwWSBg3LMVfS-1Hvh_gXxQor4-K_IL0KWYc8LZbsmvkB4sZ_Zciz3ZWos912KZsrWWynl34WC1eucx2ew81hgmn2qidor-H-w_XhaWuA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>19429556</pqid></control><display><type>article</type><title>Development and comparison of two immunoassays for the detection of 2,4,6-trinitrotoluene (TNT) based on surface plasmon resonance</title><source>Elsevier ScienceDirect Journals Complete - AutoHoldings</source><creator>Shankaran, Dhesingh Ravi ; Matsumoto, Kiyoshi ; Toko, Kiyoshi ; Miura, Norio</creator><creatorcontrib>Shankaran, Dhesingh Ravi ; Matsumoto, Kiyoshi ; Toko, Kiyoshi ; Miura, Norio</creatorcontrib><description>This paper describes the development and comparison of two immunoassays for the detection of 2,4,6-trinitrotoluene (TNT) based on competitive inhibition. Two polyclonal antibodies were used in the immunoassay; one was prepared from 2,4,6-trinitrophenol–bovine serum albumin conjugate (anti-TNP-BSA Ab, goat IgG) and another from 2,4,6-trinitrophenyl–keyhole limpet hemocyanine conjugate (anti-TNPh-KLH Ab, rabbit IgG). A solid-phase immunoassay that consisted of physically immobilized TNP-BSA conjugate was allowed to interact with these antibodies and the resonance angle changes due to the biomolecular interactions were monitored by surface plasmon resonance (SPR). The quantification of TNT was based on the change in the resonance angle shift for binding of antibodies with a TNP-BSA conjugate, which occurred in the presence of TNT in solution. Both antibodies showed a high degree of affinity for TNT and varying degrees of cross-reactivity to the related nitroaromatic derivative compounds, such as 2,4-dinitrotoluene (DNT), 1,3-dinitrobenzene (DNB), 2-amino-4,6-dintitrotoluene (2A-4,6-DNT), 4-amino-2,6-dinitrotoluene (4A-2,6-DNT) and TNP. The anti-TNPh-KLH Ab prepared in our laboratory showed a detection limit of 0.006
ng/ml (6
ppt), which was comparable to or even better than the detection limit (0.095
ng/ml or 95
ppt) of a commercially available anti-TNP-BSA Ab for detection of TNT. A pepsin solution prepared with a glycine–HCl buffer (pH 2.0) was used for regeneration of the sensor surface. The duration for a single immunocycle was ∼19 and ∼13
min for anti-TNP-BSA Ab and anti-TNPh-KLH Ab immunosystems, respectively. The proposed immunoassay is simple and possesses good analytical characteristics for quantification of TNT.</description><identifier>ISSN: 0925-4005</identifier><identifier>EISSN: 1873-3077</identifier><identifier>DOI: 10.1016/j.snb.2005.04.013</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Anti-TNP-BSA antibody ; Anti-TNPh-KLH antibody ; Immunosensor ; Indirect competitive immunoreaction ; Landmine ; Surface plasmon resonance ; TNT</subject><ispartof>Sensors and actuators. B, Chemical, 2006-03, Vol.114 (1), p.71-79</ispartof><rights>2005 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c425t-64394f2c6a4a65a45d59554c2796a6cab1ce28ce6a2380bc075b00523fe0fab63</citedby><cites>FETCH-LOGICAL-c425t-64394f2c6a4a65a45d59554c2796a6cab1ce28ce6a2380bc075b00523fe0fab63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.snb.2005.04.013$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,778,782,3539,27911,27912,45982</link.rule.ids></links><search><creatorcontrib>Shankaran, Dhesingh Ravi</creatorcontrib><creatorcontrib>Matsumoto, Kiyoshi</creatorcontrib><creatorcontrib>Toko, Kiyoshi</creatorcontrib><creatorcontrib>Miura, Norio</creatorcontrib><title>Development and comparison of two immunoassays for the detection of 2,4,6-trinitrotoluene (TNT) based on surface plasmon resonance</title><title>Sensors and actuators. B, Chemical</title><description>This paper describes the development and comparison of two immunoassays for the detection of 2,4,6-trinitrotoluene (TNT) based on competitive inhibition. Two polyclonal antibodies were used in the immunoassay; one was prepared from 2,4,6-trinitrophenol–bovine serum albumin conjugate (anti-TNP-BSA Ab, goat IgG) and another from 2,4,6-trinitrophenyl–keyhole limpet hemocyanine conjugate (anti-TNPh-KLH Ab, rabbit IgG). A solid-phase immunoassay that consisted of physically immobilized TNP-BSA conjugate was allowed to interact with these antibodies and the resonance angle changes due to the biomolecular interactions were monitored by surface plasmon resonance (SPR). The quantification of TNT was based on the change in the resonance angle shift for binding of antibodies with a TNP-BSA conjugate, which occurred in the presence of TNT in solution. Both antibodies showed a high degree of affinity for TNT and varying degrees of cross-reactivity to the related nitroaromatic derivative compounds, such as 2,4-dinitrotoluene (DNT), 1,3-dinitrobenzene (DNB), 2-amino-4,6-dintitrotoluene (2A-4,6-DNT), 4-amino-2,6-dinitrotoluene (4A-2,6-DNT) and TNP. The anti-TNPh-KLH Ab prepared in our laboratory showed a detection limit of 0.006
ng/ml (6
ppt), which was comparable to or even better than the detection limit (0.095
ng/ml or 95
ppt) of a commercially available anti-TNP-BSA Ab for detection of TNT. A pepsin solution prepared with a glycine–HCl buffer (pH 2.0) was used for regeneration of the sensor surface. The duration for a single immunocycle was ∼19 and ∼13
min for anti-TNP-BSA Ab and anti-TNPh-KLH Ab immunosystems, respectively. The proposed immunoassay is simple and possesses good analytical characteristics for quantification of TNT.</description><subject>Anti-TNP-BSA antibody</subject><subject>Anti-TNPh-KLH antibody</subject><subject>Immunosensor</subject><subject>Indirect competitive immunoreaction</subject><subject>Landmine</subject><subject>Surface plasmon resonance</subject><subject>TNT</subject><issn>0925-4005</issn><issn>1873-3077</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNqFUcuO1DAQtBBIDAsfwM0nBNIm-J1EnNDylFZwGc5Wx-kIjxI72M6u9sqX49FwhlOr1VXVqipCXnLWcsbN21Obw9gKxnTLVMu4fEQOvO9kI1nXPSYHNgjdqHp-Sp7lfGKMKWnYgfz-gHe4xG3FUCiEibq4bpB8joHGmZb7SP267iFCzvCQ6RwTLT-RTljQFX9BiWt1bZqSfPAlxRKXHQPS18dvxzd0hIwTrbi8pxkc0m2BvNY9Yf0BweFz8mSGJeOLv_OK_Pj08Xjzpbn9_vnrzfvbximhS2OUHNQsnAEFRoPSkx60Vk50gwHjYOQORe_QgJA9Gx3r9Fj9Cjkjm2E08oq8uuhuKf7aMRe7-uxwWSBg3LMVfS-1Hvh_gXxQor4-K_IL0KWYc8LZbsmvkB4sZ_Zciz3ZWos912KZsrWWynl34WC1eucx2ew81hgmn2qidor-H-w_XhaWuA</recordid><startdate>20060330</startdate><enddate>20060330</enddate><creator>Shankaran, Dhesingh Ravi</creator><creator>Matsumoto, Kiyoshi</creator><creator>Toko, Kiyoshi</creator><creator>Miura, Norio</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope><scope>7U5</scope><scope>L7M</scope></search><sort><creationdate>20060330</creationdate><title>Development and comparison of two immunoassays for the detection of 2,4,6-trinitrotoluene (TNT) based on surface plasmon resonance</title><author>Shankaran, Dhesingh Ravi ; Matsumoto, Kiyoshi ; Toko, Kiyoshi ; Miura, Norio</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c425t-64394f2c6a4a65a45d59554c2796a6cab1ce28ce6a2380bc075b00523fe0fab63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Anti-TNP-BSA antibody</topic><topic>Anti-TNPh-KLH antibody</topic><topic>Immunosensor</topic><topic>Indirect competitive immunoreaction</topic><topic>Landmine</topic><topic>Surface plasmon resonance</topic><topic>TNT</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Shankaran, Dhesingh Ravi</creatorcontrib><creatorcontrib>Matsumoto, Kiyoshi</creatorcontrib><creatorcontrib>Toko, Kiyoshi</creatorcontrib><creatorcontrib>Miura, Norio</creatorcontrib><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Sensors and actuators. B, Chemical</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Shankaran, Dhesingh Ravi</au><au>Matsumoto, Kiyoshi</au><au>Toko, Kiyoshi</au><au>Miura, Norio</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development and comparison of two immunoassays for the detection of 2,4,6-trinitrotoluene (TNT) based on surface plasmon resonance</atitle><jtitle>Sensors and actuators. B, Chemical</jtitle><date>2006-03-30</date><risdate>2006</risdate><volume>114</volume><issue>1</issue><spage>71</spage><epage>79</epage><pages>71-79</pages><issn>0925-4005</issn><eissn>1873-3077</eissn><abstract>This paper describes the development and comparison of two immunoassays for the detection of 2,4,6-trinitrotoluene (TNT) based on competitive inhibition. Two polyclonal antibodies were used in the immunoassay; one was prepared from 2,4,6-trinitrophenol–bovine serum albumin conjugate (anti-TNP-BSA Ab, goat IgG) and another from 2,4,6-trinitrophenyl–keyhole limpet hemocyanine conjugate (anti-TNPh-KLH Ab, rabbit IgG). A solid-phase immunoassay that consisted of physically immobilized TNP-BSA conjugate was allowed to interact with these antibodies and the resonance angle changes due to the biomolecular interactions were monitored by surface plasmon resonance (SPR). The quantification of TNT was based on the change in the resonance angle shift for binding of antibodies with a TNP-BSA conjugate, which occurred in the presence of TNT in solution. Both antibodies showed a high degree of affinity for TNT and varying degrees of cross-reactivity to the related nitroaromatic derivative compounds, such as 2,4-dinitrotoluene (DNT), 1,3-dinitrobenzene (DNB), 2-amino-4,6-dintitrotoluene (2A-4,6-DNT), 4-amino-2,6-dinitrotoluene (4A-2,6-DNT) and TNP. The anti-TNPh-KLH Ab prepared in our laboratory showed a detection limit of 0.006
ng/ml (6
ppt), which was comparable to or even better than the detection limit (0.095
ng/ml or 95
ppt) of a commercially available anti-TNP-BSA Ab for detection of TNT. A pepsin solution prepared with a glycine–HCl buffer (pH 2.0) was used for regeneration of the sensor surface. The duration for a single immunocycle was ∼19 and ∼13
min for anti-TNP-BSA Ab and anti-TNPh-KLH Ab immunosystems, respectively. The proposed immunoassay is simple and possesses good analytical characteristics for quantification of TNT.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.snb.2005.04.013</doi><tpages>9</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0925-4005 |
ispartof | Sensors and actuators. B, Chemical, 2006-03, Vol.114 (1), p.71-79 |
issn | 0925-4005 1873-3077 |
language | eng |
recordid | cdi_proquest_miscellaneous_28835591 |
source | Elsevier ScienceDirect Journals Complete - AutoHoldings |
subjects | Anti-TNP-BSA antibody Anti-TNPh-KLH antibody Immunosensor Indirect competitive immunoreaction Landmine Surface plasmon resonance TNT |
title | Development and comparison of two immunoassays for the detection of 2,4,6-trinitrotoluene (TNT) based on surface plasmon resonance |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T16%3A05%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20and%20comparison%20of%20two%20immunoassays%20for%20the%20detection%20of%202,4,6-trinitrotoluene%20(TNT)%20based%20on%20surface%20plasmon%20resonance&rft.jtitle=Sensors%20and%20actuators.%20B,%20Chemical&rft.au=Shankaran,%20Dhesingh%20Ravi&rft.date=2006-03-30&rft.volume=114&rft.issue=1&rft.spage=71&rft.epage=79&rft.pages=71-79&rft.issn=0925-4005&rft.eissn=1873-3077&rft_id=info:doi/10.1016/j.snb.2005.04.013&rft_dat=%3Cproquest_cross%3E19429556%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=19429556&rft_id=info:pmid/&rft_els_id=S0925400505004272&rfr_iscdi=true |