Lower Revision Rates and Improved Stability With a Monoblock Ceramic Acetabular Cup

Monoblock ceramic cups are designed to accommodate large-diameter femoral heads. This has the potential to offer the advantages of an increased range of motion and enhanced joint stability. These features could benefit younger and high-demand patients in need of total hip arthroplasty. The aim of th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of arthroplasty 2024-04, Vol.39 (4), p.985-990
Hauptverfasser: Vercruysse, Loïc Y.G., Milne, Lachlan P., Harries, Dylan T.C., de Steiger, Richard N., Wall, Christopher J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 990
container_issue 4
container_start_page 985
container_title The Journal of arthroplasty
container_volume 39
creator Vercruysse, Loïc Y.G.
Milne, Lachlan P.
Harries, Dylan T.C.
de Steiger, Richard N.
Wall, Christopher J.
description Monoblock ceramic cups are designed to accommodate large-diameter femoral heads. This has the potential to offer the advantages of an increased range of motion and enhanced joint stability. These features could benefit younger and high-demand patients in need of total hip arthroplasty. The aim of this study was to assess the survival rate and the reasons for revision of the DeltaMotion cup. Data from the AOANJRR were analyzed for all patients who had undergone a primary conventional THA performed between January 1, 2001 and December 31, 2021. Only prostheses with ceramic/ceramic, ceramic/XLPE, metal/XLPE, or CM/XLPE bearing surfaces were included. The primary outcome measure was the cumulative percent revision for all causes. Secondary outcome measures were revision for dislocation/instability, ceramic breakage, or noise. A subanalysis for cup size was also performed. There were 486,946 primary conventional THA procedures undertaken for any reason. Of these, 4,033 used the DeltaMotion cup and 482,913 were modular designs. The DeltaMotion cup had the lowest CPR for all diagnoses compared to the modular bearings at all time points, had a significantly lower revision rate for prosthesis dislocation and no revisions for squeaking compared to other modular bearings. There were 175 ceramic breakages recorded in the modular bearing group and 1 ceramic breakage in the DeltaMotion group. The DeltaMotion cup had a low rate of all-cause revision, and for dislocation, ceramic breakage, and noise. Although this cup is no longer manufactured, ongoing follow-up of newer monoblock ceramic cups will determine their suitability for younger and more active patients.
doi_str_mv 10.1016/j.arth.2023.10.032
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2881245092</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0883540323010781</els_id><sourcerecordid>2881245092</sourcerecordid><originalsourceid>FETCH-LOGICAL-c307t-26cce49232c86e2426fd970353be141e521870ce34a9a58ce807745ebfecc04c3</originalsourceid><addsrcrecordid>eNp9kEtLw0AUhQdRtFb_gAuZpZvUeSZTcCPFF1QEH7gcJje3ODXJ1Jmk4r83perS1YXDOefe-xFywtmEM56fLycudm8TwYQchAmTYoeMuJYiM4rlu2TEjJGZVkwekMOUloxxrrXaJweyMAU3OR-Rp3n4xEgfce2TDy19dB0m6tqK3jWrGNZY0afOlb723Rd99d0bdfQ-tKGsA7zTGUbXeKCXgIOpr12ks351RPYWrk54_DPH5OX66nl2m80fbu5ml_MMJCu6TOQAqKZCCjA5CiXyRTUtmNSyRK44asFNwQClclOnDaBhRaE0lgsEYArkmJxte4dDP3pMnW18Aqxr12LokxXGcKE0G1aMidhaIYaUIi7sKvrGxS_Lmd3AtEu7gWk3MDfaAHMInf7092WD1V_kl95guNgacPhy7THaBB5bwMpHhM5Wwf_X_w0neoTe</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2881245092</pqid></control><display><type>article</type><title>Lower Revision Rates and Improved Stability With a Monoblock Ceramic Acetabular Cup</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Vercruysse, Loïc Y.G. ; Milne, Lachlan P. ; Harries, Dylan T.C. ; de Steiger, Richard N. ; Wall, Christopher J.</creator><creatorcontrib>Vercruysse, Loïc Y.G. ; Milne, Lachlan P. ; Harries, Dylan T.C. ; de Steiger, Richard N. ; Wall, Christopher J.</creatorcontrib><description>Monoblock ceramic cups are designed to accommodate large-diameter femoral heads. This has the potential to offer the advantages of an increased range of motion and enhanced joint stability. These features could benefit younger and high-demand patients in need of total hip arthroplasty. The aim of this study was to assess the survival rate and the reasons for revision of the DeltaMotion cup. Data from the AOANJRR were analyzed for all patients who had undergone a primary conventional THA performed between January 1, 2001 and December 31, 2021. Only prostheses with ceramic/ceramic, ceramic/XLPE, metal/XLPE, or CM/XLPE bearing surfaces were included. The primary outcome measure was the cumulative percent revision for all causes. Secondary outcome measures were revision for dislocation/instability, ceramic breakage, or noise. A subanalysis for cup size was also performed. There were 486,946 primary conventional THA procedures undertaken for any reason. Of these, 4,033 used the DeltaMotion cup and 482,913 were modular designs. The DeltaMotion cup had the lowest CPR for all diagnoses compared to the modular bearings at all time points, had a significantly lower revision rate for prosthesis dislocation and no revisions for squeaking compared to other modular bearings. There were 175 ceramic breakages recorded in the modular bearing group and 1 ceramic breakage in the DeltaMotion group. The DeltaMotion cup had a low rate of all-cause revision, and for dislocation, ceramic breakage, and noise. Although this cup is no longer manufactured, ongoing follow-up of newer monoblock ceramic cups will determine their suitability for younger and more active patients.</description><identifier>ISSN: 0883-5403</identifier><identifier>EISSN: 1532-8406</identifier><identifier>DOI: 10.1016/j.arth.2023.10.032</identifier><identifier>PMID: 37871861</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Arthroplasty, Replacement, Hip - methods ; bearings ; ceramic-on-ceramic ; Ceramics ; dislocation ; Hip Joint - surgery ; Hip Prosthesis ; Humans ; Joint Dislocations - surgery ; large-diameter femoral head ; monoblock acetabular component ; Prosthesis Design ; Prosthesis Failure ; Reoperation ; Risk Factors ; total hip arthroplasty</subject><ispartof>The Journal of arthroplasty, 2024-04, Vol.39 (4), p.985-990</ispartof><rights>2023 Elsevier Inc.</rights><rights>Copyright © 2023 Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c307t-26cce49232c86e2426fd970353be141e521870ce34a9a58ce807745ebfecc04c3</cites><orcidid>0000-0002-2446-5326</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.arth.2023.10.032$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/37871861$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Vercruysse, Loïc Y.G.</creatorcontrib><creatorcontrib>Milne, Lachlan P.</creatorcontrib><creatorcontrib>Harries, Dylan T.C.</creatorcontrib><creatorcontrib>de Steiger, Richard N.</creatorcontrib><creatorcontrib>Wall, Christopher J.</creatorcontrib><title>Lower Revision Rates and Improved Stability With a Monoblock Ceramic Acetabular Cup</title><title>The Journal of arthroplasty</title><addtitle>J Arthroplasty</addtitle><description>Monoblock ceramic cups are designed to accommodate large-diameter femoral heads. This has the potential to offer the advantages of an increased range of motion and enhanced joint stability. These features could benefit younger and high-demand patients in need of total hip arthroplasty. The aim of this study was to assess the survival rate and the reasons for revision of the DeltaMotion cup. Data from the AOANJRR were analyzed for all patients who had undergone a primary conventional THA performed between January 1, 2001 and December 31, 2021. Only prostheses with ceramic/ceramic, ceramic/XLPE, metal/XLPE, or CM/XLPE bearing surfaces were included. The primary outcome measure was the cumulative percent revision for all causes. Secondary outcome measures were revision for dislocation/instability, ceramic breakage, or noise. A subanalysis for cup size was also performed. There were 486,946 primary conventional THA procedures undertaken for any reason. Of these, 4,033 used the DeltaMotion cup and 482,913 were modular designs. The DeltaMotion cup had the lowest CPR for all diagnoses compared to the modular bearings at all time points, had a significantly lower revision rate for prosthesis dislocation and no revisions for squeaking compared to other modular bearings. There were 175 ceramic breakages recorded in the modular bearing group and 1 ceramic breakage in the DeltaMotion group. The DeltaMotion cup had a low rate of all-cause revision, and for dislocation, ceramic breakage, and noise. Although this cup is no longer manufactured, ongoing follow-up of newer monoblock ceramic cups will determine their suitability for younger and more active patients.</description><subject>Arthroplasty, Replacement, Hip - methods</subject><subject>bearings</subject><subject>ceramic-on-ceramic</subject><subject>Ceramics</subject><subject>dislocation</subject><subject>Hip Joint - surgery</subject><subject>Hip Prosthesis</subject><subject>Humans</subject><subject>Joint Dislocations - surgery</subject><subject>large-diameter femoral head</subject><subject>monoblock acetabular component</subject><subject>Prosthesis Design</subject><subject>Prosthesis Failure</subject><subject>Reoperation</subject><subject>Risk Factors</subject><subject>total hip arthroplasty</subject><issn>0883-5403</issn><issn>1532-8406</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kEtLw0AUhQdRtFb_gAuZpZvUeSZTcCPFF1QEH7gcJje3ODXJ1Jmk4r83perS1YXDOefe-xFywtmEM56fLycudm8TwYQchAmTYoeMuJYiM4rlu2TEjJGZVkwekMOUloxxrrXaJweyMAU3OR-Rp3n4xEgfce2TDy19dB0m6tqK3jWrGNZY0afOlb723Rd99d0bdfQ-tKGsA7zTGUbXeKCXgIOpr12ks351RPYWrk54_DPH5OX66nl2m80fbu5ml_MMJCu6TOQAqKZCCjA5CiXyRTUtmNSyRK44asFNwQClclOnDaBhRaE0lgsEYArkmJxte4dDP3pMnW18Aqxr12LokxXGcKE0G1aMidhaIYaUIi7sKvrGxS_Lmd3AtEu7gWk3MDfaAHMInf7092WD1V_kl95guNgacPhy7THaBB5bwMpHhM5Wwf_X_w0neoTe</recordid><startdate>202404</startdate><enddate>202404</enddate><creator>Vercruysse, Loïc Y.G.</creator><creator>Milne, Lachlan P.</creator><creator>Harries, Dylan T.C.</creator><creator>de Steiger, Richard N.</creator><creator>Wall, Christopher J.</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-2446-5326</orcidid></search><sort><creationdate>202404</creationdate><title>Lower Revision Rates and Improved Stability With a Monoblock Ceramic Acetabular Cup</title><author>Vercruysse, Loïc Y.G. ; Milne, Lachlan P. ; Harries, Dylan T.C. ; de Steiger, Richard N. ; Wall, Christopher J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c307t-26cce49232c86e2426fd970353be141e521870ce34a9a58ce807745ebfecc04c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Arthroplasty, Replacement, Hip - methods</topic><topic>bearings</topic><topic>ceramic-on-ceramic</topic><topic>Ceramics</topic><topic>dislocation</topic><topic>Hip Joint - surgery</topic><topic>Hip Prosthesis</topic><topic>Humans</topic><topic>Joint Dislocations - surgery</topic><topic>large-diameter femoral head</topic><topic>monoblock acetabular component</topic><topic>Prosthesis Design</topic><topic>Prosthesis Failure</topic><topic>Reoperation</topic><topic>Risk Factors</topic><topic>total hip arthroplasty</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Vercruysse, Loïc Y.G.</creatorcontrib><creatorcontrib>Milne, Lachlan P.</creatorcontrib><creatorcontrib>Harries, Dylan T.C.</creatorcontrib><creatorcontrib>de Steiger, Richard N.</creatorcontrib><creatorcontrib>Wall, Christopher J.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of arthroplasty</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Vercruysse, Loïc Y.G.</au><au>Milne, Lachlan P.</au><au>Harries, Dylan T.C.</au><au>de Steiger, Richard N.</au><au>Wall, Christopher J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Lower Revision Rates and Improved Stability With a Monoblock Ceramic Acetabular Cup</atitle><jtitle>The Journal of arthroplasty</jtitle><addtitle>J Arthroplasty</addtitle><date>2024-04</date><risdate>2024</risdate><volume>39</volume><issue>4</issue><spage>985</spage><epage>990</epage><pages>985-990</pages><issn>0883-5403</issn><eissn>1532-8406</eissn><abstract>Monoblock ceramic cups are designed to accommodate large-diameter femoral heads. This has the potential to offer the advantages of an increased range of motion and enhanced joint stability. These features could benefit younger and high-demand patients in need of total hip arthroplasty. The aim of this study was to assess the survival rate and the reasons for revision of the DeltaMotion cup. Data from the AOANJRR were analyzed for all patients who had undergone a primary conventional THA performed between January 1, 2001 and December 31, 2021. Only prostheses with ceramic/ceramic, ceramic/XLPE, metal/XLPE, or CM/XLPE bearing surfaces were included. The primary outcome measure was the cumulative percent revision for all causes. Secondary outcome measures were revision for dislocation/instability, ceramic breakage, or noise. A subanalysis for cup size was also performed. There were 486,946 primary conventional THA procedures undertaken for any reason. Of these, 4,033 used the DeltaMotion cup and 482,913 were modular designs. The DeltaMotion cup had the lowest CPR for all diagnoses compared to the modular bearings at all time points, had a significantly lower revision rate for prosthesis dislocation and no revisions for squeaking compared to other modular bearings. There were 175 ceramic breakages recorded in the modular bearing group and 1 ceramic breakage in the DeltaMotion group. The DeltaMotion cup had a low rate of all-cause revision, and for dislocation, ceramic breakage, and noise. Although this cup is no longer manufactured, ongoing follow-up of newer monoblock ceramic cups will determine their suitability for younger and more active patients.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>37871861</pmid><doi>10.1016/j.arth.2023.10.032</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0002-2446-5326</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0883-5403
ispartof The Journal of arthroplasty, 2024-04, Vol.39 (4), p.985-990
issn 0883-5403
1532-8406
language eng
recordid cdi_proquest_miscellaneous_2881245092
source MEDLINE; Access via ScienceDirect (Elsevier)
subjects Arthroplasty, Replacement, Hip - methods
bearings
ceramic-on-ceramic
Ceramics
dislocation
Hip Joint - surgery
Hip Prosthesis
Humans
Joint Dislocations - surgery
large-diameter femoral head
monoblock acetabular component
Prosthesis Design
Prosthesis Failure
Reoperation
Risk Factors
total hip arthroplasty
title Lower Revision Rates and Improved Stability With a Monoblock Ceramic Acetabular Cup
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-22T03%3A10%3A45IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Lower%20Revision%20Rates%20and%20Improved%20Stability%20With%20a%20Monoblock%20Ceramic%20Acetabular%20Cup&rft.jtitle=The%20Journal%20of%20arthroplasty&rft.au=Vercruysse,%20Lo%C3%AFc%20Y.G.&rft.date=2024-04&rft.volume=39&rft.issue=4&rft.spage=985&rft.epage=990&rft.pages=985-990&rft.issn=0883-5403&rft.eissn=1532-8406&rft_id=info:doi/10.1016/j.arth.2023.10.032&rft_dat=%3Cproquest_cross%3E2881245092%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2881245092&rft_id=info:pmid/37871861&rft_els_id=S0883540323010781&rfr_iscdi=true