Faecal haemoglobin: Measurement, applications, and future potential

Faecal hemoglobin concentrations (f-Hb) can be quantitated using faecal immunochemical test for haemoglobin (FIT) analytical systems. FIT are of proven value and widely used in colorectal cancer (CRC) screening. Several factors affect f-Hb including sex, age, deprivation, geographical region, and FI...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Baillière's best practice & research. Clinical gastroenterology 2023-10, Vol.66, p.101833-101833, Article 101833
1. Verfasser: Fraser, Callum G.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 101833
container_issue
container_start_page 101833
container_title Baillière's best practice & research. Clinical gastroenterology
container_volume 66
creator Fraser, Callum G.
description Faecal hemoglobin concentrations (f-Hb) can be quantitated using faecal immunochemical test for haemoglobin (FIT) analytical systems. FIT are of proven value and widely used in colorectal cancer (CRC) screening. Several factors affect f-Hb including sex, age, deprivation, geographical region, and FIT system. Thus, FIT data may not be transferable. Women are disadvantaged in programmes using a single f-Hb threshold for all participants, but risk scoring or sex stratified thresholds could be used to minimise this problem. In addition, low but detectable f-Hb, below the threshold, implies future risk of CRC. In several countries, where colonoscopy resources are constrained, FIT are now accepted as of added value in assessment of patients presenting in primary or secondary care with symptoms, although some serious colorectal disease is missed. Elevated f-Hb in the absence of any discernible colorectal lesions is common and has been found in several diseases with a systemic inflammatory component, including circulatory, respiratory, digestive, neuropsychological, blood and endocrine diseases, and others. There is growing evidence for the value of f-Hb in post-polypectomy surveillance, potentially saving costs and colonoscopy. There may be a role for FIT systems which have lower limits of detection than currently available methods. The faecal material remaining in FIT specimen collection devices could be used for further studies, including assessment of the microbiome. The estimation of f-Hb is now a mature investigative tool but further research will undoubtedly expand applications of value.
doi_str_mv 10.1016/j.bpg.2023.101833
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2879405967</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1521691823000112</els_id><sourcerecordid>2879405967</sourcerecordid><originalsourceid>FETCH-LOGICAL-c373t-f80fbf64613a99d0742c844e1eb9bfd2a4806ca961d634b8b49ba30afcc760583</originalsourceid><addsrcrecordid>eNp9kE1PxCAQhonRxPXjB3jr0YNdobAU9GQ2rpqs8aJnAnRY2bSlQmviv5dNPXuamcz7TDIPQlcELwkm_Ha_NMNuWeGKHmZB6RFakBWtSiIJPz70FSm5JOIUnaW0xzhDUi7QeqPB6rb41NCFXRuM7--KV9BpitBBP94Uehhab_XoQ5_y1DeFm8a8LYYw5oDX7QU6cbpNcPlXz9HH5vF9_Vxu355e1g_b0tKajqUT2BnHGSdUS9ngmlVWMAYEjDSuqTQTmFstOWk4ZUYYJo2mWDtra45Xgp6j6_nuEMPXBGlUnU8W2lb3EKakKlFLhleS1zlK5qiNIaUITg3Rdzr-KILVQZjaqyxMHYSpWVhm7mcG8g_fHqJK1kNvofER7Kia4P-hfwHqQ3MA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2879405967</pqid></control><display><type>article</type><title>Faecal haemoglobin: Measurement, applications, and future potential</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>Fraser, Callum G.</creator><creatorcontrib>Fraser, Callum G.</creatorcontrib><description>Faecal hemoglobin concentrations (f-Hb) can be quantitated using faecal immunochemical test for haemoglobin (FIT) analytical systems. FIT are of proven value and widely used in colorectal cancer (CRC) screening. Several factors affect f-Hb including sex, age, deprivation, geographical region, and FIT system. Thus, FIT data may not be transferable. Women are disadvantaged in programmes using a single f-Hb threshold for all participants, but risk scoring or sex stratified thresholds could be used to minimise this problem. In addition, low but detectable f-Hb, below the threshold, implies future risk of CRC. In several countries, where colonoscopy resources are constrained, FIT are now accepted as of added value in assessment of patients presenting in primary or secondary care with symptoms, although some serious colorectal disease is missed. Elevated f-Hb in the absence of any discernible colorectal lesions is common and has been found in several diseases with a systemic inflammatory component, including circulatory, respiratory, digestive, neuropsychological, blood and endocrine diseases, and others. There is growing evidence for the value of f-Hb in post-polypectomy surveillance, potentially saving costs and colonoscopy. There may be a role for FIT systems which have lower limits of detection than currently available methods. The faecal material remaining in FIT specimen collection devices could be used for further studies, including assessment of the microbiome. The estimation of f-Hb is now a mature investigative tool but further research will undoubtedly expand applications of value.</description><identifier>ISSN: 1521-6918</identifier><identifier>EISSN: 1532-1916</identifier><identifier>DOI: 10.1016/j.bpg.2023.101833</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Colonoscopy ; Colorectal cancer ; Faecal haemoglobin ; Faecal immunochemical test ; Risk-scoring ; Screening</subject><ispartof>Baillière's best practice &amp; research. Clinical gastroenterology, 2023-10, Vol.66, p.101833-101833, Article 101833</ispartof><rights>2023 The Author</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c373t-f80fbf64613a99d0742c844e1eb9bfd2a4806ca961d634b8b49ba30afcc760583</citedby><cites>FETCH-LOGICAL-c373t-f80fbf64613a99d0742c844e1eb9bfd2a4806ca961d634b8b49ba30afcc760583</cites><orcidid>0000-0002-1333-7994</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids></links><search><creatorcontrib>Fraser, Callum G.</creatorcontrib><title>Faecal haemoglobin: Measurement, applications, and future potential</title><title>Baillière's best practice &amp; research. Clinical gastroenterology</title><description>Faecal hemoglobin concentrations (f-Hb) can be quantitated using faecal immunochemical test for haemoglobin (FIT) analytical systems. FIT are of proven value and widely used in colorectal cancer (CRC) screening. Several factors affect f-Hb including sex, age, deprivation, geographical region, and FIT system. Thus, FIT data may not be transferable. Women are disadvantaged in programmes using a single f-Hb threshold for all participants, but risk scoring or sex stratified thresholds could be used to minimise this problem. In addition, low but detectable f-Hb, below the threshold, implies future risk of CRC. In several countries, where colonoscopy resources are constrained, FIT are now accepted as of added value in assessment of patients presenting in primary or secondary care with symptoms, although some serious colorectal disease is missed. Elevated f-Hb in the absence of any discernible colorectal lesions is common and has been found in several diseases with a systemic inflammatory component, including circulatory, respiratory, digestive, neuropsychological, blood and endocrine diseases, and others. There is growing evidence for the value of f-Hb in post-polypectomy surveillance, potentially saving costs and colonoscopy. There may be a role for FIT systems which have lower limits of detection than currently available methods. The faecal material remaining in FIT specimen collection devices could be used for further studies, including assessment of the microbiome. The estimation of f-Hb is now a mature investigative tool but further research will undoubtedly expand applications of value.</description><subject>Colonoscopy</subject><subject>Colorectal cancer</subject><subject>Faecal haemoglobin</subject><subject>Faecal immunochemical test</subject><subject>Risk-scoring</subject><subject>Screening</subject><issn>1521-6918</issn><issn>1532-1916</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp9kE1PxCAQhonRxPXjB3jr0YNdobAU9GQ2rpqs8aJnAnRY2bSlQmviv5dNPXuamcz7TDIPQlcELwkm_Ha_NMNuWeGKHmZB6RFakBWtSiIJPz70FSm5JOIUnaW0xzhDUi7QeqPB6rb41NCFXRuM7--KV9BpitBBP94Uehhab_XoQ5_y1DeFm8a8LYYw5oDX7QU6cbpNcPlXz9HH5vF9_Vxu355e1g_b0tKajqUT2BnHGSdUS9ngmlVWMAYEjDSuqTQTmFstOWk4ZUYYJo2mWDtra45Xgp6j6_nuEMPXBGlUnU8W2lb3EKakKlFLhleS1zlK5qiNIaUITg3Rdzr-KILVQZjaqyxMHYSpWVhm7mcG8g_fHqJK1kNvofER7Kia4P-hfwHqQ3MA</recordid><startdate>202310</startdate><enddate>202310</enddate><creator>Fraser, Callum G.</creator><general>Elsevier Ltd</general><scope>6I.</scope><scope>AAFTH</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-1333-7994</orcidid></search><sort><creationdate>202310</creationdate><title>Faecal haemoglobin: Measurement, applications, and future potential</title><author>Fraser, Callum G.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c373t-f80fbf64613a99d0742c844e1eb9bfd2a4806ca961d634b8b49ba30afcc760583</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Colonoscopy</topic><topic>Colorectal cancer</topic><topic>Faecal haemoglobin</topic><topic>Faecal immunochemical test</topic><topic>Risk-scoring</topic><topic>Screening</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fraser, Callum G.</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Baillière's best practice &amp; research. Clinical gastroenterology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Fraser, Callum G.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Faecal haemoglobin: Measurement, applications, and future potential</atitle><jtitle>Baillière's best practice &amp; research. Clinical gastroenterology</jtitle><date>2023-10</date><risdate>2023</risdate><volume>66</volume><spage>101833</spage><epage>101833</epage><pages>101833-101833</pages><artnum>101833</artnum><issn>1521-6918</issn><eissn>1532-1916</eissn><abstract>Faecal hemoglobin concentrations (f-Hb) can be quantitated using faecal immunochemical test for haemoglobin (FIT) analytical systems. FIT are of proven value and widely used in colorectal cancer (CRC) screening. Several factors affect f-Hb including sex, age, deprivation, geographical region, and FIT system. Thus, FIT data may not be transferable. Women are disadvantaged in programmes using a single f-Hb threshold for all participants, but risk scoring or sex stratified thresholds could be used to minimise this problem. In addition, low but detectable f-Hb, below the threshold, implies future risk of CRC. In several countries, where colonoscopy resources are constrained, FIT are now accepted as of added value in assessment of patients presenting in primary or secondary care with symptoms, although some serious colorectal disease is missed. Elevated f-Hb in the absence of any discernible colorectal lesions is common and has been found in several diseases with a systemic inflammatory component, including circulatory, respiratory, digestive, neuropsychological, blood and endocrine diseases, and others. There is growing evidence for the value of f-Hb in post-polypectomy surveillance, potentially saving costs and colonoscopy. There may be a role for FIT systems which have lower limits of detection than currently available methods. The faecal material remaining in FIT specimen collection devices could be used for further studies, including assessment of the microbiome. The estimation of f-Hb is now a mature investigative tool but further research will undoubtedly expand applications of value.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.bpg.2023.101833</doi><tpages>1</tpages><orcidid>https://orcid.org/0000-0002-1333-7994</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1521-6918
ispartof Baillière's best practice & research. Clinical gastroenterology, 2023-10, Vol.66, p.101833-101833, Article 101833
issn 1521-6918
1532-1916
language eng
recordid cdi_proquest_miscellaneous_2879405967
source ScienceDirect Journals (5 years ago - present)
subjects Colonoscopy
Colorectal cancer
Faecal haemoglobin
Faecal immunochemical test
Risk-scoring
Screening
title Faecal haemoglobin: Measurement, applications, and future potential
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-12T02%3A57%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Faecal%20haemoglobin:%20Measurement,%20applications,%20and%20future%20potential&rft.jtitle=Bailli%C3%A8re's%20best%20practice%20&%20research.%20Clinical%20gastroenterology&rft.au=Fraser,%20Callum%20G.&rft.date=2023-10&rft.volume=66&rft.spage=101833&rft.epage=101833&rft.pages=101833-101833&rft.artnum=101833&rft.issn=1521-6918&rft.eissn=1532-1916&rft_id=info:doi/10.1016/j.bpg.2023.101833&rft_dat=%3Cproquest_cross%3E2879405967%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2879405967&rft_id=info:pmid/&rft_els_id=S1521691823000112&rfr_iscdi=true