Use of Three-Dimensional Intracardiac Echocardiography Catheter in the Evaluation of Prosthetic Pulmonary Valves after Transcatheter Replacement

Transcatheter pulmonary valve replacement (TPVR) is commonly performed in patients with congenital heart disease as a safe alternative to replacement via open heart surgery. Intracardiac echocardiography (ICE) is a useful technique for evaluating multiple structures that are difficult to assess by o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the American Society of Echocardiography 2024-02, Vol.37 (2), p.226-236
Hauptverfasser: Gonzalez de Alba, Cesar, Zablah, Jenny E., Burkett, Dale, Jone, Pei-Ni, Rodriguez, Salvador A., Morgan, Gareth J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 236
container_issue 2
container_start_page 226
container_title Journal of the American Society of Echocardiography
container_volume 37
creator Gonzalez de Alba, Cesar
Zablah, Jenny E.
Burkett, Dale
Jone, Pei-Ni
Rodriguez, Salvador A.
Morgan, Gareth J.
description Transcatheter pulmonary valve replacement (TPVR) is commonly performed in patients with congenital heart disease as a safe alternative to replacement via open heart surgery. Intracardiac echocardiography (ICE) is a useful technique for evaluating multiple structures that are difficult to assess by other echocardiographic techniques, particularly the pulmonary valve. To our knowledge, the use of three-dimensional (3D) ICE catheters to evaluate prosthetic valves after TPVR has not been reported. Three-dimensional ICE catheters offer a comprehensive evaluation of transcatheter-deployed pulmonary valves through 3D, 3D color, xPlane, and multiplane reconstruction. The aim of this study is to demonstrate the feasibility of using 3D ICE catheters, outline their role in evaluating post-TPVR deployment success and complications, consider their additive value to two-dimensional ICE, and present our institutional experience with it in 50 cases of TPVR. •Assessment of prosthetic pulmonary valves with 3D ICE catheters is feasible.•xPlane, 3D, 3D color, and multiplane reconstruction can be performed with 3D ICE.•Post-TPVR endocarditis and stent or valve dysfunction can be detected by 3D ICE.
doi_str_mv 10.1016/j.echo.2023.10.006
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2878020360</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0894731723005369</els_id><sourcerecordid>2878020360</sourcerecordid><originalsourceid>FETCH-LOGICAL-c356t-bd53944f51d46d1e29bb53fc90890276905205754cde35bc6f7259d28f519b2a3</originalsourceid><addsrcrecordid>eNp9kc1u1DAUhS0EotPCC7BAXrLJcG3HTiyxQdOBVqpEhaZsLce-YTzKz2AnI_UteGQcpmXJylf2Od_V8SHkHYM1A6Y-Htbo9uOaAxf5Yg2gXpAVA10VqtLyJVlBrcuiEqy6IJcpHQBA1gCvyYWoaqEV0yvy-yEhHVu620fE4jr0OKQwDrajt8MUrbPRB-voNi_6O48_oz3uH-nGTnucMNIw0DzR7cl2s52ydaHdxzEt78HR-7nrMy8-0h-2O2Gitl1su2iH5J4h3_HYWYd5-fSGvGptl_Dt03lFHr5sd5ub4u7b19vN57vCCammovFS6LJsJfOl8gy5bhopWqdzZuCV0iA5yEqWzqOQjVNtxaX2vM4O3XArrsiHM_cYx18zpsn0ITnsOjvgOCfD66oGDkJBlvKz1OVYKWJrjjH0OZJhYJYmzMEsTZilieUuN5FN75_4c9Oj_2d5_vos-HQWYE55ChhNcgEHhz5EdJPxY_gf_w9wBpxb</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2878020360</pqid></control><display><type>article</type><title>Use of Three-Dimensional Intracardiac Echocardiography Catheter in the Evaluation of Prosthetic Pulmonary Valves after Transcatheter Replacement</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Gonzalez de Alba, Cesar ; Zablah, Jenny E. ; Burkett, Dale ; Jone, Pei-Ni ; Rodriguez, Salvador A. ; Morgan, Gareth J.</creator><creatorcontrib>Gonzalez de Alba, Cesar ; Zablah, Jenny E. ; Burkett, Dale ; Jone, Pei-Ni ; Rodriguez, Salvador A. ; Morgan, Gareth J.</creatorcontrib><description>Transcatheter pulmonary valve replacement (TPVR) is commonly performed in patients with congenital heart disease as a safe alternative to replacement via open heart surgery. Intracardiac echocardiography (ICE) is a useful technique for evaluating multiple structures that are difficult to assess by other echocardiographic techniques, particularly the pulmonary valve. To our knowledge, the use of three-dimensional (3D) ICE catheters to evaluate prosthetic valves after TPVR has not been reported. Three-dimensional ICE catheters offer a comprehensive evaluation of transcatheter-deployed pulmonary valves through 3D, 3D color, xPlane, and multiplane reconstruction. The aim of this study is to demonstrate the feasibility of using 3D ICE catheters, outline their role in evaluating post-TPVR deployment success and complications, consider their additive value to two-dimensional ICE, and present our institutional experience with it in 50 cases of TPVR. •Assessment of prosthetic pulmonary valves with 3D ICE catheters is feasible.•xPlane, 3D, 3D color, and multiplane reconstruction can be performed with 3D ICE.•Post-TPVR endocarditis and stent or valve dysfunction can be detected by 3D ICE.</description><identifier>ISSN: 0894-7317</identifier><identifier>EISSN: 1097-6795</identifier><identifier>DOI: 10.1016/j.echo.2023.10.006</identifier><identifier>PMID: 37839619</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>3D echocardiography ; Congenital heart disease ; Intracardiac echocardiography ; Transcatheter pulmonary valve replacement</subject><ispartof>Journal of the American Society of Echocardiography, 2024-02, Vol.37 (2), p.226-236</ispartof><rights>2023 American Society of Echocardiography</rights><rights>Copyright © 2023 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c356t-bd53944f51d46d1e29bb53fc90890276905205754cde35bc6f7259d28f519b2a3</citedby><cites>FETCH-LOGICAL-c356t-bd53944f51d46d1e29bb53fc90890276905205754cde35bc6f7259d28f519b2a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0894731723005369$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/37839619$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Gonzalez de Alba, Cesar</creatorcontrib><creatorcontrib>Zablah, Jenny E.</creatorcontrib><creatorcontrib>Burkett, Dale</creatorcontrib><creatorcontrib>Jone, Pei-Ni</creatorcontrib><creatorcontrib>Rodriguez, Salvador A.</creatorcontrib><creatorcontrib>Morgan, Gareth J.</creatorcontrib><title>Use of Three-Dimensional Intracardiac Echocardiography Catheter in the Evaluation of Prosthetic Pulmonary Valves after Transcatheter Replacement</title><title>Journal of the American Society of Echocardiography</title><addtitle>J Am Soc Echocardiogr</addtitle><description>Transcatheter pulmonary valve replacement (TPVR) is commonly performed in patients with congenital heart disease as a safe alternative to replacement via open heart surgery. Intracardiac echocardiography (ICE) is a useful technique for evaluating multiple structures that are difficult to assess by other echocardiographic techniques, particularly the pulmonary valve. To our knowledge, the use of three-dimensional (3D) ICE catheters to evaluate prosthetic valves after TPVR has not been reported. Three-dimensional ICE catheters offer a comprehensive evaluation of transcatheter-deployed pulmonary valves through 3D, 3D color, xPlane, and multiplane reconstruction. The aim of this study is to demonstrate the feasibility of using 3D ICE catheters, outline their role in evaluating post-TPVR deployment success and complications, consider their additive value to two-dimensional ICE, and present our institutional experience with it in 50 cases of TPVR. •Assessment of prosthetic pulmonary valves with 3D ICE catheters is feasible.•xPlane, 3D, 3D color, and multiplane reconstruction can be performed with 3D ICE.•Post-TPVR endocarditis and stent or valve dysfunction can be detected by 3D ICE.</description><subject>3D echocardiography</subject><subject>Congenital heart disease</subject><subject>Intracardiac echocardiography</subject><subject>Transcatheter pulmonary valve replacement</subject><issn>0894-7317</issn><issn>1097-6795</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kc1u1DAUhS0EotPCC7BAXrLJcG3HTiyxQdOBVqpEhaZsLce-YTzKz2AnI_UteGQcpmXJylf2Od_V8SHkHYM1A6Y-Htbo9uOaAxf5Yg2gXpAVA10VqtLyJVlBrcuiEqy6IJcpHQBA1gCvyYWoaqEV0yvy-yEhHVu620fE4jr0OKQwDrajt8MUrbPRB-voNi_6O48_oz3uH-nGTnucMNIw0DzR7cl2s52ydaHdxzEt78HR-7nrMy8-0h-2O2Gitl1su2iH5J4h3_HYWYd5-fSGvGptl_Dt03lFHr5sd5ub4u7b19vN57vCCammovFS6LJsJfOl8gy5bhopWqdzZuCV0iA5yEqWzqOQjVNtxaX2vM4O3XArrsiHM_cYx18zpsn0ITnsOjvgOCfD66oGDkJBlvKz1OVYKWJrjjH0OZJhYJYmzMEsTZilieUuN5FN75_4c9Oj_2d5_vos-HQWYE55ChhNcgEHhz5EdJPxY_gf_w9wBpxb</recordid><startdate>202402</startdate><enddate>202402</enddate><creator>Gonzalez de Alba, Cesar</creator><creator>Zablah, Jenny E.</creator><creator>Burkett, Dale</creator><creator>Jone, Pei-Ni</creator><creator>Rodriguez, Salvador A.</creator><creator>Morgan, Gareth J.</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202402</creationdate><title>Use of Three-Dimensional Intracardiac Echocardiography Catheter in the Evaluation of Prosthetic Pulmonary Valves after Transcatheter Replacement</title><author>Gonzalez de Alba, Cesar ; Zablah, Jenny E. ; Burkett, Dale ; Jone, Pei-Ni ; Rodriguez, Salvador A. ; Morgan, Gareth J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c356t-bd53944f51d46d1e29bb53fc90890276905205754cde35bc6f7259d28f519b2a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>3D echocardiography</topic><topic>Congenital heart disease</topic><topic>Intracardiac echocardiography</topic><topic>Transcatheter pulmonary valve replacement</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gonzalez de Alba, Cesar</creatorcontrib><creatorcontrib>Zablah, Jenny E.</creatorcontrib><creatorcontrib>Burkett, Dale</creatorcontrib><creatorcontrib>Jone, Pei-Ni</creatorcontrib><creatorcontrib>Rodriguez, Salvador A.</creatorcontrib><creatorcontrib>Morgan, Gareth J.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of the American Society of Echocardiography</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gonzalez de Alba, Cesar</au><au>Zablah, Jenny E.</au><au>Burkett, Dale</au><au>Jone, Pei-Ni</au><au>Rodriguez, Salvador A.</au><au>Morgan, Gareth J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Use of Three-Dimensional Intracardiac Echocardiography Catheter in the Evaluation of Prosthetic Pulmonary Valves after Transcatheter Replacement</atitle><jtitle>Journal of the American Society of Echocardiography</jtitle><addtitle>J Am Soc Echocardiogr</addtitle><date>2024-02</date><risdate>2024</risdate><volume>37</volume><issue>2</issue><spage>226</spage><epage>236</epage><pages>226-236</pages><issn>0894-7317</issn><eissn>1097-6795</eissn><abstract>Transcatheter pulmonary valve replacement (TPVR) is commonly performed in patients with congenital heart disease as a safe alternative to replacement via open heart surgery. Intracardiac echocardiography (ICE) is a useful technique for evaluating multiple structures that are difficult to assess by other echocardiographic techniques, particularly the pulmonary valve. To our knowledge, the use of three-dimensional (3D) ICE catheters to evaluate prosthetic valves after TPVR has not been reported. Three-dimensional ICE catheters offer a comprehensive evaluation of transcatheter-deployed pulmonary valves through 3D, 3D color, xPlane, and multiplane reconstruction. The aim of this study is to demonstrate the feasibility of using 3D ICE catheters, outline their role in evaluating post-TPVR deployment success and complications, consider their additive value to two-dimensional ICE, and present our institutional experience with it in 50 cases of TPVR. •Assessment of prosthetic pulmonary valves with 3D ICE catheters is feasible.•xPlane, 3D, 3D color, and multiplane reconstruction can be performed with 3D ICE.•Post-TPVR endocarditis and stent or valve dysfunction can be detected by 3D ICE.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>37839619</pmid><doi>10.1016/j.echo.2023.10.006</doi><tpages>11</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0894-7317
ispartof Journal of the American Society of Echocardiography, 2024-02, Vol.37 (2), p.226-236
issn 0894-7317
1097-6795
language eng
recordid cdi_proquest_miscellaneous_2878020360
source Elsevier ScienceDirect Journals Complete
subjects 3D echocardiography
Congenital heart disease
Intracardiac echocardiography
Transcatheter pulmonary valve replacement
title Use of Three-Dimensional Intracardiac Echocardiography Catheter in the Evaluation of Prosthetic Pulmonary Valves after Transcatheter Replacement
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T02%3A09%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Use%20of%20Three-Dimensional%20Intracardiac%20Echocardiography%20Catheter%20in%20the%20Evaluation%20of%20Prosthetic%20Pulmonary%20Valves%20after%20Transcatheter%20Replacement&rft.jtitle=Journal%20of%20the%20American%20Society%20of%20Echocardiography&rft.au=Gonzalez%20de%20Alba,%20Cesar&rft.date=2024-02&rft.volume=37&rft.issue=2&rft.spage=226&rft.epage=236&rft.pages=226-236&rft.issn=0894-7317&rft.eissn=1097-6795&rft_id=info:doi/10.1016/j.echo.2023.10.006&rft_dat=%3Cproquest_cross%3E2878020360%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2878020360&rft_id=info:pmid/37839619&rft_els_id=S0894731723005369&rfr_iscdi=true