Evaluation of a smartphone‐operated point‐of‐care device using loop‐mediated isothermal amplification technology for rapid and remote detection of SARS‐CoV‐2

During the SARS‐CoV‐2 pandemic, rapid and sensitive detection of SARS‐CoV‐2 has been of high importance for outbreak control. Reverse transcriptase polymerase chain reaction (RT‐PCR) is the current gold standard, however, the procedures require an equipped laboratory setting and personnel, which hav...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of medical virology 2023-10, Vol.95 (10), p.e29158-n/a
Hauptverfasser: Meyers, Eline, Park, JeongHo, Coen, Anja, Raman, Leen, Heytens, Stefan, Rhee, Joowon, Padalko, Elizaveta, Cools, Piet
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page n/a
container_issue 10
container_start_page e29158
container_title Journal of medical virology
container_volume 95
creator Meyers, Eline
Park, JeongHo
Coen, Anja
Raman, Leen
Heytens, Stefan
Rhee, Joowon
Padalko, Elizaveta
Cools, Piet
description During the SARS‐CoV‐2 pandemic, rapid and sensitive detection of SARS‐CoV‐2 has been of high importance for outbreak control. Reverse transcriptase polymerase chain reaction (RT‐PCR) is the current gold standard, however, the procedures require an equipped laboratory setting and personnel, which have been regularly overburdened during the pandemic. This often resulted in long waiting times for patients. In contrast, reverse transcriptase loop‐mediated isothermal amplification (RT‐LAMP) is a simple, cost‐efficient, and fast procedure, allowing for rapid and remote detection of SARS‐CoV‐2. In the current study, we performed a clinical evaluation of a new point‐of‐care test system based on LAMP‐technology for SARS‐CoV‐2 detection, providing a result within 25 min (1copy™ COVID‐19 MDx Kit Professional system). We tested 112 paired nasopharyngeal swabs, collected in the COVID‐19 Ghent University Hospital test center, using the 1copy™ COVID‐19 MDx Kit Professional system, and RT‐PCR as the reference method. The test system was found to have a clinical sensitivity of 93.24% (69/74) (95% confidence interval [CI]: 84.93%–97.77%) and specificity of 97.37% (37/38) (95% CI: 86.19%–99.93%). Due to its easy smartphone operation and ready‐to‐use reagents, it ought to be easily applied in for instance general practices, pharmacies, nursing homes, schools, and companies. This would facilitate an efficient SARS‐CoV‐2 outbreak control and quarantine policy, as diagnosis can occur sooner in a near‐patient setting.
doi_str_mv 10.1002/jmv.29158
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2878016252</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2878016252</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3028-20aa53e35a9297335cb7d7bbf98d5235b9c88879cc98fbbf0ebf8523be3c1b1f3</originalsourceid><addsrcrecordid>eNp1kU1OwzAQhS0EEqWw4AZewiLFdkhiL1HFr4qQKLCNHGdMjZw42GlRdxyBa3AtToJLYMlmRpr55s1oHkKHlEwoIezkpVlNmKAZ30IjSkSeCFLQbTQi9DRP8pxmu2gvhBdCCBeMjdDn-UrapeyNa7HTWOLQSN93C9fC1_uH68DLHmrcOdP2m4KOQUkPuIaVUYCXwbTP2DrXxUYDtfnBTXD9AnwjLZZNZ402aljRg1q0zrrnNdbOYy87U2PZ1thD4_qNaiT-jpmf3c-j6tQ9xcj20Y6WNsDBbx6jx4vzh-lVMru7vJ6ezRKVEsYTRqTMUkgzKZgo0jRTVVEXVaUFrzOWZpVQnPNCKCW4jmUCleaxUUGqaEV1OkZHg27n3esSQl82JiiwVrbglqFkvOCE5izOjNHxgCrvQvCgy86b-L91SUm5saOMdpQ_dkT2ZGDfjIX1_2B5c_s0THwDZH6WbA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2878016252</pqid></control><display><type>article</type><title>Evaluation of a smartphone‐operated point‐of‐care device using loop‐mediated isothermal amplification technology for rapid and remote detection of SARS‐CoV‐2</title><source>Wiley Online Library - AutoHoldings Journals</source><creator>Meyers, Eline ; Park, JeongHo ; Coen, Anja ; Raman, Leen ; Heytens, Stefan ; Rhee, Joowon ; Padalko, Elizaveta ; Cools, Piet</creator><creatorcontrib>Meyers, Eline ; Park, JeongHo ; Coen, Anja ; Raman, Leen ; Heytens, Stefan ; Rhee, Joowon ; Padalko, Elizaveta ; Cools, Piet</creatorcontrib><description>During the SARS‐CoV‐2 pandemic, rapid and sensitive detection of SARS‐CoV‐2 has been of high importance for outbreak control. Reverse transcriptase polymerase chain reaction (RT‐PCR) is the current gold standard, however, the procedures require an equipped laboratory setting and personnel, which have been regularly overburdened during the pandemic. This often resulted in long waiting times for patients. In contrast, reverse transcriptase loop‐mediated isothermal amplification (RT‐LAMP) is a simple, cost‐efficient, and fast procedure, allowing for rapid and remote detection of SARS‐CoV‐2. In the current study, we performed a clinical evaluation of a new point‐of‐care test system based on LAMP‐technology for SARS‐CoV‐2 detection, providing a result within 25 min (1copy™ COVID‐19 MDx Kit Professional system). We tested 112 paired nasopharyngeal swabs, collected in the COVID‐19 Ghent University Hospital test center, using the 1copy™ COVID‐19 MDx Kit Professional system, and RT‐PCR as the reference method. The test system was found to have a clinical sensitivity of 93.24% (69/74) (95% confidence interval [CI]: 84.93%–97.77%) and specificity of 97.37% (37/38) (95% CI: 86.19%–99.93%). Due to its easy smartphone operation and ready‐to‐use reagents, it ought to be easily applied in for instance general practices, pharmacies, nursing homes, schools, and companies. This would facilitate an efficient SARS‐CoV‐2 outbreak control and quarantine policy, as diagnosis can occur sooner in a near‐patient setting.</description><identifier>ISSN: 0146-6615</identifier><identifier>EISSN: 1096-9071</identifier><identifier>DOI: 10.1002/jmv.29158</identifier><language>eng</language><subject>point‐of‐care diagnostics ; RT‐LAMP ; SARS‐CoV‐2</subject><ispartof>Journal of medical virology, 2023-10, Vol.95 (10), p.e29158-n/a</ispartof><rights>2023 Wiley Periodicals LLC.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3028-20aa53e35a9297335cb7d7bbf98d5235b9c88879cc98fbbf0ebf8523be3c1b1f3</citedby><cites>FETCH-LOGICAL-c3028-20aa53e35a9297335cb7d7bbf98d5235b9c88879cc98fbbf0ebf8523be3c1b1f3</cites><orcidid>0000-0002-3549-9548</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fjmv.29158$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fjmv.29158$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27901,27902,45550,45551</link.rule.ids></links><search><creatorcontrib>Meyers, Eline</creatorcontrib><creatorcontrib>Park, JeongHo</creatorcontrib><creatorcontrib>Coen, Anja</creatorcontrib><creatorcontrib>Raman, Leen</creatorcontrib><creatorcontrib>Heytens, Stefan</creatorcontrib><creatorcontrib>Rhee, Joowon</creatorcontrib><creatorcontrib>Padalko, Elizaveta</creatorcontrib><creatorcontrib>Cools, Piet</creatorcontrib><title>Evaluation of a smartphone‐operated point‐of‐care device using loop‐mediated isothermal amplification technology for rapid and remote detection of SARS‐CoV‐2</title><title>Journal of medical virology</title><description>During the SARS‐CoV‐2 pandemic, rapid and sensitive detection of SARS‐CoV‐2 has been of high importance for outbreak control. Reverse transcriptase polymerase chain reaction (RT‐PCR) is the current gold standard, however, the procedures require an equipped laboratory setting and personnel, which have been regularly overburdened during the pandemic. This often resulted in long waiting times for patients. In contrast, reverse transcriptase loop‐mediated isothermal amplification (RT‐LAMP) is a simple, cost‐efficient, and fast procedure, allowing for rapid and remote detection of SARS‐CoV‐2. In the current study, we performed a clinical evaluation of a new point‐of‐care test system based on LAMP‐technology for SARS‐CoV‐2 detection, providing a result within 25 min (1copy™ COVID‐19 MDx Kit Professional system). We tested 112 paired nasopharyngeal swabs, collected in the COVID‐19 Ghent University Hospital test center, using the 1copy™ COVID‐19 MDx Kit Professional system, and RT‐PCR as the reference method. The test system was found to have a clinical sensitivity of 93.24% (69/74) (95% confidence interval [CI]: 84.93%–97.77%) and specificity of 97.37% (37/38) (95% CI: 86.19%–99.93%). Due to its easy smartphone operation and ready‐to‐use reagents, it ought to be easily applied in for instance general practices, pharmacies, nursing homes, schools, and companies. This would facilitate an efficient SARS‐CoV‐2 outbreak control and quarantine policy, as diagnosis can occur sooner in a near‐patient setting.</description><subject>point‐of‐care diagnostics</subject><subject>RT‐LAMP</subject><subject>SARS‐CoV‐2</subject><issn>0146-6615</issn><issn>1096-9071</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp1kU1OwzAQhS0EEqWw4AZewiLFdkhiL1HFr4qQKLCNHGdMjZw42GlRdxyBa3AtToJLYMlmRpr55s1oHkKHlEwoIezkpVlNmKAZ30IjSkSeCFLQbTQi9DRP8pxmu2gvhBdCCBeMjdDn-UrapeyNa7HTWOLQSN93C9fC1_uH68DLHmrcOdP2m4KOQUkPuIaVUYCXwbTP2DrXxUYDtfnBTXD9AnwjLZZNZ402aljRg1q0zrrnNdbOYy87U2PZ1thD4_qNaiT-jpmf3c-j6tQ9xcj20Y6WNsDBbx6jx4vzh-lVMru7vJ6ezRKVEsYTRqTMUkgzKZgo0jRTVVEXVaUFrzOWZpVQnPNCKCW4jmUCleaxUUGqaEV1OkZHg27n3esSQl82JiiwVrbglqFkvOCE5izOjNHxgCrvQvCgy86b-L91SUm5saOMdpQ_dkT2ZGDfjIX1_2B5c_s0THwDZH6WbA</recordid><startdate>202310</startdate><enddate>202310</enddate><creator>Meyers, Eline</creator><creator>Park, JeongHo</creator><creator>Coen, Anja</creator><creator>Raman, Leen</creator><creator>Heytens, Stefan</creator><creator>Rhee, Joowon</creator><creator>Padalko, Elizaveta</creator><creator>Cools, Piet</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-3549-9548</orcidid></search><sort><creationdate>202310</creationdate><title>Evaluation of a smartphone‐operated point‐of‐care device using loop‐mediated isothermal amplification technology for rapid and remote detection of SARS‐CoV‐2</title><author>Meyers, Eline ; Park, JeongHo ; Coen, Anja ; Raman, Leen ; Heytens, Stefan ; Rhee, Joowon ; Padalko, Elizaveta ; Cools, Piet</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3028-20aa53e35a9297335cb7d7bbf98d5235b9c88879cc98fbbf0ebf8523be3c1b1f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>point‐of‐care diagnostics</topic><topic>RT‐LAMP</topic><topic>SARS‐CoV‐2</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Meyers, Eline</creatorcontrib><creatorcontrib>Park, JeongHo</creatorcontrib><creatorcontrib>Coen, Anja</creatorcontrib><creatorcontrib>Raman, Leen</creatorcontrib><creatorcontrib>Heytens, Stefan</creatorcontrib><creatorcontrib>Rhee, Joowon</creatorcontrib><creatorcontrib>Padalko, Elizaveta</creatorcontrib><creatorcontrib>Cools, Piet</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of medical virology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Meyers, Eline</au><au>Park, JeongHo</au><au>Coen, Anja</au><au>Raman, Leen</au><au>Heytens, Stefan</au><au>Rhee, Joowon</au><au>Padalko, Elizaveta</au><au>Cools, Piet</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of a smartphone‐operated point‐of‐care device using loop‐mediated isothermal amplification technology for rapid and remote detection of SARS‐CoV‐2</atitle><jtitle>Journal of medical virology</jtitle><date>2023-10</date><risdate>2023</risdate><volume>95</volume><issue>10</issue><spage>e29158</spage><epage>n/a</epage><pages>e29158-n/a</pages><issn>0146-6615</issn><eissn>1096-9071</eissn><abstract>During the SARS‐CoV‐2 pandemic, rapid and sensitive detection of SARS‐CoV‐2 has been of high importance for outbreak control. Reverse transcriptase polymerase chain reaction (RT‐PCR) is the current gold standard, however, the procedures require an equipped laboratory setting and personnel, which have been regularly overburdened during the pandemic. This often resulted in long waiting times for patients. In contrast, reverse transcriptase loop‐mediated isothermal amplification (RT‐LAMP) is a simple, cost‐efficient, and fast procedure, allowing for rapid and remote detection of SARS‐CoV‐2. In the current study, we performed a clinical evaluation of a new point‐of‐care test system based on LAMP‐technology for SARS‐CoV‐2 detection, providing a result within 25 min (1copy™ COVID‐19 MDx Kit Professional system). We tested 112 paired nasopharyngeal swabs, collected in the COVID‐19 Ghent University Hospital test center, using the 1copy™ COVID‐19 MDx Kit Professional system, and RT‐PCR as the reference method. The test system was found to have a clinical sensitivity of 93.24% (69/74) (95% confidence interval [CI]: 84.93%–97.77%) and specificity of 97.37% (37/38) (95% CI: 86.19%–99.93%). Due to its easy smartphone operation and ready‐to‐use reagents, it ought to be easily applied in for instance general practices, pharmacies, nursing homes, schools, and companies. This would facilitate an efficient SARS‐CoV‐2 outbreak control and quarantine policy, as diagnosis can occur sooner in a near‐patient setting.</abstract><doi>10.1002/jmv.29158</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0002-3549-9548</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0146-6615
ispartof Journal of medical virology, 2023-10, Vol.95 (10), p.e29158-n/a
issn 0146-6615
1096-9071
language eng
recordid cdi_proquest_miscellaneous_2878016252
source Wiley Online Library - AutoHoldings Journals
subjects point‐of‐care diagnostics
RT‐LAMP
SARS‐CoV‐2
title Evaluation of a smartphone‐operated point‐of‐care device using loop‐mediated isothermal amplification technology for rapid and remote detection of SARS‐CoV‐2
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-07T15%3A39%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20a%20smartphone%E2%80%90operated%20point%E2%80%90of%E2%80%90care%20device%20using%20loop%E2%80%90mediated%20isothermal%20amplification%20technology%20for%20rapid%20and%20remote%20detection%20of%20SARS%E2%80%90CoV%E2%80%902&rft.jtitle=Journal%20of%20medical%20virology&rft.au=Meyers,%20Eline&rft.date=2023-10&rft.volume=95&rft.issue=10&rft.spage=e29158&rft.epage=n/a&rft.pages=e29158-n/a&rft.issn=0146-6615&rft.eissn=1096-9071&rft_id=info:doi/10.1002/jmv.29158&rft_dat=%3Cproquest_cross%3E2878016252%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2878016252&rft_id=info:pmid/&rfr_iscdi=true