A simplified method to estimate energy sayings of artificial lighting use from daylighting

This paper provides a simplified analysis method to evaluate the potential of daylighting to save energy associated with electric lighting use. Specifically, impacts on daylighting performance are investigated for several combinations of building geometry, window opening size, and glazing type for f...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Building and environment 2005-06, Vol.40 (6), p.747-754.
Hauptverfasser: Krarti, Moncef, Erickson, Paul M, Hillman, Timothy C
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 754.
container_issue 6
container_start_page 747
container_title Building and environment
container_volume 40
creator Krarti, Moncef
Erickson, Paul M
Hillman, Timothy C
description This paper provides a simplified analysis method to evaluate the potential of daylighting to save energy associated with electric lighting use. Specifically, impacts on daylighting performance are investigated for several combinations of building geometry, window opening size, and glazing type for four geographical locations in the United States. Four building geometries with various window-to-floor areas, along with different glazing types have been analyzed. It was determined that for most commercial buildings with glass transmittance Values above 0.5, increasing window area to floor area ratio above 0.5, daylighting does not provide significant additional lighting energy savings. A direct correlation has been established between window transmittance and window area on annual lighting reductions. A model is proposed to estimate lighting energy savings given perimeter area, window area, and window type. Verification and validation of the model's predictions are demonstrated using results from building energy simulation as well as experimental data.
doi_str_mv 10.1016/j.buildenv.2004.08.007
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_28652004</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>28652004</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_286520043</originalsourceid><addsrcrecordid>eNqNjs1qwkAURmdhwfTnFcpddZfpTUbTdClF8QFcuZHR3MQrM5mYOxHy9qZQ9119cDhwPqXeM9QZZsXnRR8HdhW1N50jLjSWGvFrphI0BaaZyc1cPYtccJK_zSJR-xUI-85xzVSBp3gOFcQAJJG9jQTUUt-MIHbkthEINdg-TvaJrQPHzTlOHAYhqPvgobLjA76qp9o6obe_fVEfm_XuZ5t2fbgOU-DgWU7knG0pDHLIy2L5e9r8W7wD2S5Nsw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>28652004</pqid></control><display><type>article</type><title>A simplified method to estimate energy sayings of artificial lighting use from daylighting</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Krarti, Moncef ; Erickson, Paul M ; Hillman, Timothy C</creator><creatorcontrib>Krarti, Moncef ; Erickson, Paul M ; Hillman, Timothy C</creatorcontrib><description>This paper provides a simplified analysis method to evaluate the potential of daylighting to save energy associated with electric lighting use. Specifically, impacts on daylighting performance are investigated for several combinations of building geometry, window opening size, and glazing type for four geographical locations in the United States. Four building geometries with various window-to-floor areas, along with different glazing types have been analyzed. It was determined that for most commercial buildings with glass transmittance Values above 0.5, increasing window area to floor area ratio above 0.5, daylighting does not provide significant additional lighting energy savings. A direct correlation has been established between window transmittance and window area on annual lighting reductions. A model is proposed to estimate lighting energy savings given perimeter area, window area, and window type. Verification and validation of the model's predictions are demonstrated using results from building energy simulation as well as experimental data.</description><identifier>ISSN: 0360-1323</identifier><identifier>DOI: 10.1016/j.buildenv.2004.08.007</identifier><language>eng</language><ispartof>Building and environment, 2005-06, Vol.40 (6), p.747-754.</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Krarti, Moncef</creatorcontrib><creatorcontrib>Erickson, Paul M</creatorcontrib><creatorcontrib>Hillman, Timothy C</creatorcontrib><title>A simplified method to estimate energy sayings of artificial lighting use from daylighting</title><title>Building and environment</title><description>This paper provides a simplified analysis method to evaluate the potential of daylighting to save energy associated with electric lighting use. Specifically, impacts on daylighting performance are investigated for several combinations of building geometry, window opening size, and glazing type for four geographical locations in the United States. Four building geometries with various window-to-floor areas, along with different glazing types have been analyzed. It was determined that for most commercial buildings with glass transmittance Values above 0.5, increasing window area to floor area ratio above 0.5, daylighting does not provide significant additional lighting energy savings. A direct correlation has been established between window transmittance and window area on annual lighting reductions. A model is proposed to estimate lighting energy savings given perimeter area, window area, and window type. Verification and validation of the model's predictions are demonstrated using results from building energy simulation as well as experimental data.</description><issn>0360-1323</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNqNjs1qwkAURmdhwfTnFcpddZfpTUbTdClF8QFcuZHR3MQrM5mYOxHy9qZQ9119cDhwPqXeM9QZZsXnRR8HdhW1N50jLjSWGvFrphI0BaaZyc1cPYtccJK_zSJR-xUI-85xzVSBp3gOFcQAJJG9jQTUUt-MIHbkthEINdg-TvaJrQPHzTlOHAYhqPvgobLjA76qp9o6obe_fVEfm_XuZ5t2fbgOU-DgWU7knG0pDHLIy2L5e9r8W7wD2S5Nsw</recordid><startdate>20050601</startdate><enddate>20050601</enddate><creator>Krarti, Moncef</creator><creator>Erickson, Paul M</creator><creator>Hillman, Timothy C</creator><scope>8FD</scope><scope>F28</scope><scope>FR3</scope></search><sort><creationdate>20050601</creationdate><title>A simplified method to estimate energy sayings of artificial lighting use from daylighting</title><author>Krarti, Moncef ; Erickson, Paul M ; Hillman, Timothy C</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_286520043</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Krarti, Moncef</creatorcontrib><creatorcontrib>Erickson, Paul M</creatorcontrib><creatorcontrib>Hillman, Timothy C</creatorcontrib><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><jtitle>Building and environment</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Krarti, Moncef</au><au>Erickson, Paul M</au><au>Hillman, Timothy C</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A simplified method to estimate energy sayings of artificial lighting use from daylighting</atitle><jtitle>Building and environment</jtitle><date>2005-06-01</date><risdate>2005</risdate><volume>40</volume><issue>6</issue><spage>747</spage><epage>754.</epage><pages>747-754.</pages><issn>0360-1323</issn><abstract>This paper provides a simplified analysis method to evaluate the potential of daylighting to save energy associated with electric lighting use. Specifically, impacts on daylighting performance are investigated for several combinations of building geometry, window opening size, and glazing type for four geographical locations in the United States. Four building geometries with various window-to-floor areas, along with different glazing types have been analyzed. It was determined that for most commercial buildings with glass transmittance Values above 0.5, increasing window area to floor area ratio above 0.5, daylighting does not provide significant additional lighting energy savings. A direct correlation has been established between window transmittance and window area on annual lighting reductions. A model is proposed to estimate lighting energy savings given perimeter area, window area, and window type. Verification and validation of the model's predictions are demonstrated using results from building energy simulation as well as experimental data.</abstract><doi>10.1016/j.buildenv.2004.08.007</doi></addata></record>
fulltext fulltext
identifier ISSN: 0360-1323
ispartof Building and environment, 2005-06, Vol.40 (6), p.747-754.
issn 0360-1323
language eng
recordid cdi_proquest_miscellaneous_28652004
source Elsevier ScienceDirect Journals Complete
title A simplified method to estimate energy sayings of artificial lighting use from daylighting
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T17%3A54%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20simplified%20method%20to%20estimate%20energy%20sayings%20of%20artificial%20lighting%20use%20from%20daylighting&rft.jtitle=Building%20and%20environment&rft.au=Krarti,%20Moncef&rft.date=2005-06-01&rft.volume=40&rft.issue=6&rft.spage=747&rft.epage=754.&rft.pages=747-754.&rft.issn=0360-1323&rft_id=info:doi/10.1016/j.buildenv.2004.08.007&rft_dat=%3Cproquest%3E28652004%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=28652004&rft_id=info:pmid/&rfr_iscdi=true