An improved resistive amplification network for fast timing photomultiplier tubes
We have designed, fabricated and tested an improved resistive amplification network for photomultiplier tubes (PMTs) resulting in high gain and fast rise time without the ringing usually associated with pulses with short decay times. Although the design is optimized for the Thorn EMI 9807B PMT, and...
Gespeichert in:
Veröffentlicht in: | Measurement : journal of the International Measurement Confederation 2005-03, Vol.37 (2), p.131-134 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 134 |
---|---|
container_issue | 2 |
container_start_page | 131 |
container_title | Measurement : journal of the International Measurement Confederation |
container_volume | 37 |
creator | Bezboruah, T. Boruah, K. Boruah, P.K. |
description | We have designed, fabricated and tested an improved resistive amplification network for photomultiplier tubes (PMTs) resulting in high gain and fast rise time without the ringing usually associated with pulses with short decay times. Although the design is optimized for the Thorn EMI 9807B PMT, and its equivalent from other makes, the principle can be easily extended for many different types of photomultiplier tubes. |
doi_str_mv | 10.1016/j.measurement.2004.11.004 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_28590032</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0263224104001137</els_id><sourcerecordid>28590032</sourcerecordid><originalsourceid>FETCH-LOGICAL-c352t-37c170e4ef90e5495225242e51cf5f7bc559d4eebf69c0a886f29556237c3aab3</originalsourceid><addsrcrecordid>eNqNkE1LxDAYhIMouK7-h3jx1pqkTT-Oy-IXLIig4C2k6RvN2jQ1SVf892ZZDx49PZeZYWYQuqQkp4RW19vcggyzBwtjzBkhZU5pnnCEFrSpi6yk7PUYLQirioyxkp6isxC2hJCqaKsFelqN2NjJux302EMwIZodYGmnwWijZDRuxCPEL-c_sHYeaxkijsaa8Q1P7y46Ow_RJDV4HOcOwjk60XIIcPHLJXq5vXle32ebx7uH9WqTqYKzmBW1ojWBEnRLgJctZ4yzkgGnSnNdd4rzti8BOl21isimqTRrOa9YMhZSdsUSXR1yU_nPGUIU1gQFwyBHcHMQrOEtIQVLwvYgVN6F4EGLyRsr_begROxPFFvx50SxP1FQKhKSd33wQlqySxtFUAZGBb3xoKLonflHyg-UqIM9</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>28590032</pqid></control><display><type>article</type><title>An improved resistive amplification network for fast timing photomultiplier tubes</title><source>Access via ScienceDirect (Elsevier)</source><creator>Bezboruah, T. ; Boruah, K. ; Boruah, P.K.</creator><creatorcontrib>Bezboruah, T. ; Boruah, K. ; Boruah, P.K.</creatorcontrib><description>We have designed, fabricated and tested an improved resistive amplification network for photomultiplier tubes (PMTs) resulting in high gain and fast rise time without the ringing usually associated with pulses with short decay times. Although the design is optimized for the Thorn EMI 9807B PMT, and its equivalent from other makes, the principle can be easily extended for many different types of photomultiplier tubes.</description><identifier>ISSN: 0263-2241</identifier><identifier>EISSN: 1873-412X</identifier><identifier>DOI: 10.1016/j.measurement.2004.11.004</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Critical damping ; Decay time ; Impedance mismatch ; Ringing</subject><ispartof>Measurement : journal of the International Measurement Confederation, 2005-03, Vol.37 (2), p.131-134</ispartof><rights>2004 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c352t-37c170e4ef90e5495225242e51cf5f7bc559d4eebf69c0a886f29556237c3aab3</citedby><cites>FETCH-LOGICAL-c352t-37c170e4ef90e5495225242e51cf5f7bc559d4eebf69c0a886f29556237c3aab3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.measurement.2004.11.004$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>315,781,785,3551,27926,27927,45997</link.rule.ids></links><search><creatorcontrib>Bezboruah, T.</creatorcontrib><creatorcontrib>Boruah, K.</creatorcontrib><creatorcontrib>Boruah, P.K.</creatorcontrib><title>An improved resistive amplification network for fast timing photomultiplier tubes</title><title>Measurement : journal of the International Measurement Confederation</title><description>We have designed, fabricated and tested an improved resistive amplification network for photomultiplier tubes (PMTs) resulting in high gain and fast rise time without the ringing usually associated with pulses with short decay times. Although the design is optimized for the Thorn EMI 9807B PMT, and its equivalent from other makes, the principle can be easily extended for many different types of photomultiplier tubes.</description><subject>Critical damping</subject><subject>Decay time</subject><subject>Impedance mismatch</subject><subject>Ringing</subject><issn>0263-2241</issn><issn>1873-412X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNqNkE1LxDAYhIMouK7-h3jx1pqkTT-Oy-IXLIig4C2k6RvN2jQ1SVf892ZZDx49PZeZYWYQuqQkp4RW19vcggyzBwtjzBkhZU5pnnCEFrSpi6yk7PUYLQirioyxkp6isxC2hJCqaKsFelqN2NjJux302EMwIZodYGmnwWijZDRuxCPEL-c_sHYeaxkijsaa8Q1P7y46Ow_RJDV4HOcOwjk60XIIcPHLJXq5vXle32ebx7uH9WqTqYKzmBW1ojWBEnRLgJctZ4yzkgGnSnNdd4rzti8BOl21isimqTRrOa9YMhZSdsUSXR1yU_nPGUIU1gQFwyBHcHMQrOEtIQVLwvYgVN6F4EGLyRsr_begROxPFFvx50SxP1FQKhKSd33wQlqySxtFUAZGBb3xoKLonflHyg-UqIM9</recordid><startdate>20050301</startdate><enddate>20050301</enddate><creator>Bezboruah, T.</creator><creator>Boruah, K.</creator><creator>Boruah, P.K.</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7TB</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>L7M</scope></search><sort><creationdate>20050301</creationdate><title>An improved resistive amplification network for fast timing photomultiplier tubes</title><author>Bezboruah, T. ; Boruah, K. ; Boruah, P.K.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c352t-37c170e4ef90e5495225242e51cf5f7bc559d4eebf69c0a886f29556237c3aab3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Critical damping</topic><topic>Decay time</topic><topic>Impedance mismatch</topic><topic>Ringing</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bezboruah, T.</creatorcontrib><creatorcontrib>Boruah, K.</creatorcontrib><creatorcontrib>Boruah, P.K.</creatorcontrib><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Measurement : journal of the International Measurement Confederation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bezboruah, T.</au><au>Boruah, K.</au><au>Boruah, P.K.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An improved resistive amplification network for fast timing photomultiplier tubes</atitle><jtitle>Measurement : journal of the International Measurement Confederation</jtitle><date>2005-03-01</date><risdate>2005</risdate><volume>37</volume><issue>2</issue><spage>131</spage><epage>134</epage><pages>131-134</pages><issn>0263-2241</issn><eissn>1873-412X</eissn><abstract>We have designed, fabricated and tested an improved resistive amplification network for photomultiplier tubes (PMTs) resulting in high gain and fast rise time without the ringing usually associated with pulses with short decay times. Although the design is optimized for the Thorn EMI 9807B PMT, and its equivalent from other makes, the principle can be easily extended for many different types of photomultiplier tubes.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.measurement.2004.11.004</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0263-2241 |
ispartof | Measurement : journal of the International Measurement Confederation, 2005-03, Vol.37 (2), p.131-134 |
issn | 0263-2241 1873-412X |
language | eng |
recordid | cdi_proquest_miscellaneous_28590032 |
source | Access via ScienceDirect (Elsevier) |
subjects | Critical damping Decay time Impedance mismatch Ringing |
title | An improved resistive amplification network for fast timing photomultiplier tubes |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-18T10%3A42%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20improved%20resistive%20amplification%20network%20for%20fast%20timing%20photomultiplier%20tubes&rft.jtitle=Measurement%20:%20journal%20of%20the%20International%20Measurement%20Confederation&rft.au=Bezboruah,%20T.&rft.date=2005-03-01&rft.volume=37&rft.issue=2&rft.spage=131&rft.epage=134&rft.pages=131-134&rft.issn=0263-2241&rft.eissn=1873-412X&rft_id=info:doi/10.1016/j.measurement.2004.11.004&rft_dat=%3Cproquest_cross%3E28590032%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=28590032&rft_id=info:pmid/&rft_els_id=S0263224104001137&rfr_iscdi=true |