Reference materials for calibrating magnetic permeability measuring equipment

The measurement and comparison of the relative magnetic permeability of weakly magnetic materials at different field strengths by an absolute method and by commercial instrumentation have been undertaken in order to provide reference materials for the calibration of these instruments. The absolute m...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on magnetics 1990-09, Vol.26 (5), p.2050-2051
Hauptverfasser: Drake, A.E., Ager, C.I.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2051
container_issue 5
container_start_page 2050
container_title IEEE transactions on magnetics
container_volume 26
creator Drake, A.E.
Ager, C.I.
description The measurement and comparison of the relative magnetic permeability of weakly magnetic materials at different field strengths by an absolute method and by commercial instrumentation have been undertaken in order to provide reference materials for the calibration of these instruments. The absolute measurement method is described, the main types of commercial instruments are reviewed, and a variety of metals and alloys are examined for possible use as reference standards. The measurements are described, and typical results for permeability measurements using commercial instruments and the absolute method are given. The problems that the users of permeability measuring equipment encounter both in their calibration and in their operation are highlighted.< >
doi_str_mv 10.1109/20.104616
format Article
fullrecord <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_proquest_miscellaneous_28588662</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>104616</ieee_id><sourcerecordid>28588662</sourcerecordid><originalsourceid>FETCH-LOGICAL-c338t-a28944874a4fa5b7ce5ebe59409787935c20b7b4ec6153a48c6c29f3b457d9493</originalsourceid><addsrcrecordid>eNqFkD1LBDEQhoMoeJ4WtlbbKFisJtlJNinl8AtOBNF6SeLsEdmvS3aL-_fm7gTtrN4M88wDeQk5Z_SGMapveUoKkskDMmMaWE6p1IdkRilTuQYJx-Qkxq80gmB0Rl7esMaAncOsNSMGb5qY1X3InGm8DWb03SptVh2O3mUDhhaN9Y0fN1l6xSls97ie_NBiN56SozoJ8Own5-Tj4f598ZQvXx-fF3fL3BWFGnPDlQZQJRiojbClQ4EWhQaqS1XqQjhObWkBnWSiMKCcdFzXhQVRfmrQxZxc7b1D6NcTxrFqfXTYNKbDfooVV0IpKfn_IGjJOKcJvN6DLvQxBqyrIfjWhE3FaLVttuIpd80m9vJHamKqqQ6mcz7-HqS_lUqrxF3sOY-If3w7yTd6DIA9</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>24961220</pqid></control><display><type>article</type><title>Reference materials for calibrating magnetic permeability measuring equipment</title><source>IEEE Electronic Library (IEL)</source><creator>Drake, A.E. ; Ager, C.I.</creator><creatorcontrib>Drake, A.E. ; Ager, C.I.</creatorcontrib><description>The measurement and comparison of the relative magnetic permeability of weakly magnetic materials at different field strengths by an absolute method and by commercial instrumentation have been undertaken in order to provide reference materials for the calibration of these instruments. The absolute measurement method is described, the main types of commercial instruments are reviewed, and a variety of metals and alloys are examined for possible use as reference standards. The measurements are described, and typical results for permeability measurements using commercial instruments and the absolute method are given. The problems that the users of permeability measuring equipment encounter both in their calibration and in their operation are highlighted.&lt; &gt;</description><identifier>ISSN: 0018-9464</identifier><identifier>EISSN: 1941-0069</identifier><identifier>DOI: 10.1109/20.104616</identifier><identifier>CODEN: IEMGAQ</identifier><language>eng</language><publisher>New York, NY: IEEE</publisher><subject>Calibration ; Coils ; Exact sciences and technology ; Instruments ; Instruments, apparatus, components and techniques common to several branches of physics and astronomy ; Magnetic field measurement ; Magnetic flux ; Magnetic materials ; Permeability measurement ; Physics ; Polarization ; Solenoids ; Testing</subject><ispartof>IEEE transactions on magnetics, 1990-09, Vol.26 (5), p.2050-2051</ispartof><rights>1991 INIST-CNRS</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c338t-a28944874a4fa5b7ce5ebe59409787935c20b7b4ec6153a48c6c29f3b457d9493</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/104616$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,314,776,780,785,786,792,23909,23910,25118,27901,27902,54733</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/104616$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=19447898$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Drake, A.E.</creatorcontrib><creatorcontrib>Ager, C.I.</creatorcontrib><title>Reference materials for calibrating magnetic permeability measuring equipment</title><title>IEEE transactions on magnetics</title><addtitle>TMAG</addtitle><description>The measurement and comparison of the relative magnetic permeability of weakly magnetic materials at different field strengths by an absolute method and by commercial instrumentation have been undertaken in order to provide reference materials for the calibration of these instruments. The absolute measurement method is described, the main types of commercial instruments are reviewed, and a variety of metals and alloys are examined for possible use as reference standards. The measurements are described, and typical results for permeability measurements using commercial instruments and the absolute method are given. The problems that the users of permeability measuring equipment encounter both in their calibration and in their operation are highlighted.&lt; &gt;</description><subject>Calibration</subject><subject>Coils</subject><subject>Exact sciences and technology</subject><subject>Instruments</subject><subject>Instruments, apparatus, components and techniques common to several branches of physics and astronomy</subject><subject>Magnetic field measurement</subject><subject>Magnetic flux</subject><subject>Magnetic materials</subject><subject>Permeability measurement</subject><subject>Physics</subject><subject>Polarization</subject><subject>Solenoids</subject><subject>Testing</subject><issn>0018-9464</issn><issn>1941-0069</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1990</creationdate><recordtype>article</recordtype><recordid>eNqFkD1LBDEQhoMoeJ4WtlbbKFisJtlJNinl8AtOBNF6SeLsEdmvS3aL-_fm7gTtrN4M88wDeQk5Z_SGMapveUoKkskDMmMaWE6p1IdkRilTuQYJx-Qkxq80gmB0Rl7esMaAncOsNSMGb5qY1X3InGm8DWb03SptVh2O3mUDhhaN9Y0fN1l6xSls97ie_NBiN56SozoJ8Own5-Tj4f598ZQvXx-fF3fL3BWFGnPDlQZQJRiojbClQ4EWhQaqS1XqQjhObWkBnWSiMKCcdFzXhQVRfmrQxZxc7b1D6NcTxrFqfXTYNKbDfooVV0IpKfn_IGjJOKcJvN6DLvQxBqyrIfjWhE3FaLVttuIpd80m9vJHamKqqQ6mcz7-HqS_lUqrxF3sOY-If3w7yTd6DIA9</recordid><startdate>19900901</startdate><enddate>19900901</enddate><creator>Drake, A.E.</creator><creator>Ager, C.I.</creator><general>IEEE</general><general>Institute of Electrical and Electronics Engineers</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>7SP</scope></search><sort><creationdate>19900901</creationdate><title>Reference materials for calibrating magnetic permeability measuring equipment</title><author>Drake, A.E. ; Ager, C.I.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c338t-a28944874a4fa5b7ce5ebe59409787935c20b7b4ec6153a48c6c29f3b457d9493</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1990</creationdate><topic>Calibration</topic><topic>Coils</topic><topic>Exact sciences and technology</topic><topic>Instruments</topic><topic>Instruments, apparatus, components and techniques common to several branches of physics and astronomy</topic><topic>Magnetic field measurement</topic><topic>Magnetic flux</topic><topic>Magnetic materials</topic><topic>Permeability measurement</topic><topic>Physics</topic><topic>Polarization</topic><topic>Solenoids</topic><topic>Testing</topic><toplevel>online_resources</toplevel><creatorcontrib>Drake, A.E.</creatorcontrib><creatorcontrib>Ager, C.I.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Electronics &amp; Communications Abstracts</collection><jtitle>IEEE transactions on magnetics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Drake, A.E.</au><au>Ager, C.I.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reference materials for calibrating magnetic permeability measuring equipment</atitle><jtitle>IEEE transactions on magnetics</jtitle><stitle>TMAG</stitle><date>1990-09-01</date><risdate>1990</risdate><volume>26</volume><issue>5</issue><spage>2050</spage><epage>2051</epage><pages>2050-2051</pages><issn>0018-9464</issn><eissn>1941-0069</eissn><coden>IEMGAQ</coden><abstract>The measurement and comparison of the relative magnetic permeability of weakly magnetic materials at different field strengths by an absolute method and by commercial instrumentation have been undertaken in order to provide reference materials for the calibration of these instruments. The absolute measurement method is described, the main types of commercial instruments are reviewed, and a variety of metals and alloys are examined for possible use as reference standards. The measurements are described, and typical results for permeability measurements using commercial instruments and the absolute method are given. The problems that the users of permeability measuring equipment encounter both in their calibration and in their operation are highlighted.&lt; &gt;</abstract><cop>New York, NY</cop><pub>IEEE</pub><doi>10.1109/20.104616</doi><tpages>2</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0018-9464
ispartof IEEE transactions on magnetics, 1990-09, Vol.26 (5), p.2050-2051
issn 0018-9464
1941-0069
language eng
recordid cdi_proquest_miscellaneous_28588662
source IEEE Electronic Library (IEL)
subjects Calibration
Coils
Exact sciences and technology
Instruments
Instruments, apparatus, components and techniques common to several branches of physics and astronomy
Magnetic field measurement
Magnetic flux
Magnetic materials
Permeability measurement
Physics
Polarization
Solenoids
Testing
title Reference materials for calibrating magnetic permeability measuring equipment
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T18%3A39%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reference%20materials%20for%20calibrating%20magnetic%20permeability%20measuring%20equipment&rft.jtitle=IEEE%20transactions%20on%20magnetics&rft.au=Drake,%20A.E.&rft.date=1990-09-01&rft.volume=26&rft.issue=5&rft.spage=2050&rft.epage=2051&rft.pages=2050-2051&rft.issn=0018-9464&rft.eissn=1941-0069&rft.coden=IEMGAQ&rft_id=info:doi/10.1109/20.104616&rft_dat=%3Cproquest_RIE%3E28588662%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=24961220&rft_id=info:pmid/&rft_ieee_id=104616&rfr_iscdi=true