How clean is your ice machine? Revealing microbial amplification and presence of opportunistic pathogens in hospital ice-water machines

Ice machines in healthcare facilities have been suspected and even linked to outbreaks and pseudo-outbreaks. Guidelines exist for maintenance of these devices but there is no clear independent infection control standard, and little is known about their microbial contamination. To evaluate the microb...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of hospital infection 2023-11, Vol.141, p.9-16
Hauptverfasser: Cazals, M., Bédard, E., Soucy, C., Savard, P., Prévost, M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 16
container_issue
container_start_page 9
container_title The Journal of hospital infection
container_volume 141
creator Cazals, M.
Bédard, E.
Soucy, C.
Savard, P.
Prévost, M.
description Ice machines in healthcare facilities have been suspected and even linked to outbreaks and pseudo-outbreaks. Guidelines exist for maintenance of these devices but there is no clear independent infection control standard, and little is known about their microbial contamination. To evaluate the microbial contamination, amplification, and presence of opportunistic pathogens in ice-water machines in a healthcare facility. Concentrations of general microbial indicators (heterotrophic plate counts (HPC), total and intact cells), faecal indicators (enterococci) and opportunistic pathogens (Pseudomonas aeruginosa, non-tuberculous mycobacteria (NTM), Candida spp.) were measured in 36 ice-water machines on patient wards of a 772-bed hospital. Profile sampling was performed on five ice-water machines and adjacent faucets to identify sites of microbial proliferation. Candida spp. were found in half of ice-water samples while enterococci and P. aeruginosa were present in six and 11 drain inlets respectively. NTM were measured in all ice-water samples and 35 out of 36 biofilms. Pre-filters and ice machines are sites for additional amplification: NTM densities were on average 1.3 log10 higher in water of ice machine flushed 5 min compared to flushed adjacent tap water. Ice machine design needs to be adapted to reduce microbial proliferation. The absence of correlation between HPC densities (current microbial indicators) and NTM concentrations suggests a need for cleaning efficiency indicators better correlated with opportunistic pathogens. Cleaning and disinfection guidelines of ice machines in healthcare facilities need to be improved, especially when ice is given to the most vulnerable patients, and NTM may be an efficiency indicator.
doi_str_mv 10.1016/j.jhin.2023.08.007
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2854969567</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0195670123002700</els_id><sourcerecordid>2854969567</sourcerecordid><originalsourceid>FETCH-LOGICAL-c333t-5e9172cd3536360418c6508abca6c527e8d4437b005ff998ea5fa4003b9b57783</originalsourceid><addsrcrecordid>eNp9kM9q3DAQxkVpoNukL9CTjr3YHVmWbUGhlNA0hUChpGchy-PsLLbkStqEPEFeu1q2vfY0MHx_-H6MvRdQCxDdx0N92JOvG2hkDUMN0L9iO6FkUzVa6tdsB0KrqutBvGFvUzoAQPmrHXu5DU_cLWg9p8SfwzFycshX60oefuY_8RHtQv6Br-RiGMku3K7bQjM5myl4bv3Et4gJffGFmYdtCzEfPaVMjm8278MD-sTJ831IG-WSUCqqJ5sx_itKV-xitkvCd3_vJft18_X--ra6-_Ht-_WXu8pJKXOlUIu-cZNUspMdtGJwnYLBjs52TjU9DlPbyn4EUPOs9YBWzbYFkKMeVd8P8pJ9OOduMfw-YspmpeRwWazHcEymGVSrO626vkibs7TsTinibLZIq43PRoA5UTcHc6JuTtQNDKZQL6ZPZxOWEY-E0SRHJzQTRXTZTIH-Z_8D7XGNiQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2854969567</pqid></control><display><type>article</type><title>How clean is your ice machine? Revealing microbial amplification and presence of opportunistic pathogens in hospital ice-water machines</title><source>Elsevier ScienceDirect Journals</source><creator>Cazals, M. ; Bédard, E. ; Soucy, C. ; Savard, P. ; Prévost, M.</creator><creatorcontrib>Cazals, M. ; Bédard, E. ; Soucy, C. ; Savard, P. ; Prévost, M.</creatorcontrib><description>Ice machines in healthcare facilities have been suspected and even linked to outbreaks and pseudo-outbreaks. Guidelines exist for maintenance of these devices but there is no clear independent infection control standard, and little is known about their microbial contamination. To evaluate the microbial contamination, amplification, and presence of opportunistic pathogens in ice-water machines in a healthcare facility. Concentrations of general microbial indicators (heterotrophic plate counts (HPC), total and intact cells), faecal indicators (enterococci) and opportunistic pathogens (Pseudomonas aeruginosa, non-tuberculous mycobacteria (NTM), Candida spp.) were measured in 36 ice-water machines on patient wards of a 772-bed hospital. Profile sampling was performed on five ice-water machines and adjacent faucets to identify sites of microbial proliferation. Candida spp. were found in half of ice-water samples while enterococci and P. aeruginosa were present in six and 11 drain inlets respectively. NTM were measured in all ice-water samples and 35 out of 36 biofilms. Pre-filters and ice machines are sites for additional amplification: NTM densities were on average 1.3 log10 higher in water of ice machine flushed 5 min compared to flushed adjacent tap water. Ice machine design needs to be adapted to reduce microbial proliferation. The absence of correlation between HPC densities (current microbial indicators) and NTM concentrations suggests a need for cleaning efficiency indicators better correlated with opportunistic pathogens. Cleaning and disinfection guidelines of ice machines in healthcare facilities need to be improved, especially when ice is given to the most vulnerable patients, and NTM may be an efficiency indicator.</description><identifier>ISSN: 0195-6701</identifier><identifier>EISSN: 1532-2939</identifier><identifier>DOI: 10.1016/j.jhin.2023.08.007</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Candida ; Cleaning ; Disinfection ; Ice machines ; Microbial amplification ; Non-tuberculous mycobacteria</subject><ispartof>The Journal of hospital infection, 2023-11, Vol.141, p.9-16</ispartof><rights>2023 The Healthcare Infection Society</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c333t-5e9172cd3536360418c6508abca6c527e8d4437b005ff998ea5fa4003b9b57783</citedby><cites>FETCH-LOGICAL-c333t-5e9172cd3536360418c6508abca6c527e8d4437b005ff998ea5fa4003b9b57783</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0195670123002700$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3536,27903,27904,65309</link.rule.ids></links><search><creatorcontrib>Cazals, M.</creatorcontrib><creatorcontrib>Bédard, E.</creatorcontrib><creatorcontrib>Soucy, C.</creatorcontrib><creatorcontrib>Savard, P.</creatorcontrib><creatorcontrib>Prévost, M.</creatorcontrib><title>How clean is your ice machine? Revealing microbial amplification and presence of opportunistic pathogens in hospital ice-water machines</title><title>The Journal of hospital infection</title><description>Ice machines in healthcare facilities have been suspected and even linked to outbreaks and pseudo-outbreaks. Guidelines exist for maintenance of these devices but there is no clear independent infection control standard, and little is known about their microbial contamination. To evaluate the microbial contamination, amplification, and presence of opportunistic pathogens in ice-water machines in a healthcare facility. Concentrations of general microbial indicators (heterotrophic plate counts (HPC), total and intact cells), faecal indicators (enterococci) and opportunistic pathogens (Pseudomonas aeruginosa, non-tuberculous mycobacteria (NTM), Candida spp.) were measured in 36 ice-water machines on patient wards of a 772-bed hospital. Profile sampling was performed on five ice-water machines and adjacent faucets to identify sites of microbial proliferation. Candida spp. were found in half of ice-water samples while enterococci and P. aeruginosa were present in six and 11 drain inlets respectively. NTM were measured in all ice-water samples and 35 out of 36 biofilms. Pre-filters and ice machines are sites for additional amplification: NTM densities were on average 1.3 log10 higher in water of ice machine flushed 5 min compared to flushed adjacent tap water. Ice machine design needs to be adapted to reduce microbial proliferation. The absence of correlation between HPC densities (current microbial indicators) and NTM concentrations suggests a need for cleaning efficiency indicators better correlated with opportunistic pathogens. Cleaning and disinfection guidelines of ice machines in healthcare facilities need to be improved, especially when ice is given to the most vulnerable patients, and NTM may be an efficiency indicator.</description><subject>Candida</subject><subject>Cleaning</subject><subject>Disinfection</subject><subject>Ice machines</subject><subject>Microbial amplification</subject><subject>Non-tuberculous mycobacteria</subject><issn>0195-6701</issn><issn>1532-2939</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp9kM9q3DAQxkVpoNukL9CTjr3YHVmWbUGhlNA0hUChpGchy-PsLLbkStqEPEFeu1q2vfY0MHx_-H6MvRdQCxDdx0N92JOvG2hkDUMN0L9iO6FkUzVa6tdsB0KrqutBvGFvUzoAQPmrHXu5DU_cLWg9p8SfwzFycshX60oefuY_8RHtQv6Br-RiGMku3K7bQjM5myl4bv3Et4gJffGFmYdtCzEfPaVMjm8278MD-sTJ831IG-WSUCqqJ5sx_itKV-xitkvCd3_vJft18_X--ra6-_Ht-_WXu8pJKXOlUIu-cZNUspMdtGJwnYLBjs52TjU9DlPbyn4EUPOs9YBWzbYFkKMeVd8P8pJ9OOduMfw-YspmpeRwWazHcEymGVSrO626vkibs7TsTinibLZIq43PRoA5UTcHc6JuTtQNDKZQL6ZPZxOWEY-E0SRHJzQTRXTZTIH-Z_8D7XGNiQ</recordid><startdate>202311</startdate><enddate>202311</enddate><creator>Cazals, M.</creator><creator>Bédard, E.</creator><creator>Soucy, C.</creator><creator>Savard, P.</creator><creator>Prévost, M.</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202311</creationdate><title>How clean is your ice machine? Revealing microbial amplification and presence of opportunistic pathogens in hospital ice-water machines</title><author>Cazals, M. ; Bédard, E. ; Soucy, C. ; Savard, P. ; Prévost, M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c333t-5e9172cd3536360418c6508abca6c527e8d4437b005ff998ea5fa4003b9b57783</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Candida</topic><topic>Cleaning</topic><topic>Disinfection</topic><topic>Ice machines</topic><topic>Microbial amplification</topic><topic>Non-tuberculous mycobacteria</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cazals, M.</creatorcontrib><creatorcontrib>Bédard, E.</creatorcontrib><creatorcontrib>Soucy, C.</creatorcontrib><creatorcontrib>Savard, P.</creatorcontrib><creatorcontrib>Prévost, M.</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of hospital infection</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cazals, M.</au><au>Bédard, E.</au><au>Soucy, C.</au><au>Savard, P.</au><au>Prévost, M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>How clean is your ice machine? Revealing microbial amplification and presence of opportunistic pathogens in hospital ice-water machines</atitle><jtitle>The Journal of hospital infection</jtitle><date>2023-11</date><risdate>2023</risdate><volume>141</volume><spage>9</spage><epage>16</epage><pages>9-16</pages><issn>0195-6701</issn><eissn>1532-2939</eissn><abstract>Ice machines in healthcare facilities have been suspected and even linked to outbreaks and pseudo-outbreaks. Guidelines exist for maintenance of these devices but there is no clear independent infection control standard, and little is known about their microbial contamination. To evaluate the microbial contamination, amplification, and presence of opportunistic pathogens in ice-water machines in a healthcare facility. Concentrations of general microbial indicators (heterotrophic plate counts (HPC), total and intact cells), faecal indicators (enterococci) and opportunistic pathogens (Pseudomonas aeruginosa, non-tuberculous mycobacteria (NTM), Candida spp.) were measured in 36 ice-water machines on patient wards of a 772-bed hospital. Profile sampling was performed on five ice-water machines and adjacent faucets to identify sites of microbial proliferation. Candida spp. were found in half of ice-water samples while enterococci and P. aeruginosa were present in six and 11 drain inlets respectively. NTM were measured in all ice-water samples and 35 out of 36 biofilms. Pre-filters and ice machines are sites for additional amplification: NTM densities were on average 1.3 log10 higher in water of ice machine flushed 5 min compared to flushed adjacent tap water. Ice machine design needs to be adapted to reduce microbial proliferation. The absence of correlation between HPC densities (current microbial indicators) and NTM concentrations suggests a need for cleaning efficiency indicators better correlated with opportunistic pathogens. Cleaning and disinfection guidelines of ice machines in healthcare facilities need to be improved, especially when ice is given to the most vulnerable patients, and NTM may be an efficiency indicator.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.jhin.2023.08.007</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0195-6701
ispartof The Journal of hospital infection, 2023-11, Vol.141, p.9-16
issn 0195-6701
1532-2939
language eng
recordid cdi_proquest_miscellaneous_2854969567
source Elsevier ScienceDirect Journals
subjects Candida
Cleaning
Disinfection
Ice machines
Microbial amplification
Non-tuberculous mycobacteria
title How clean is your ice machine? Revealing microbial amplification and presence of opportunistic pathogens in hospital ice-water machines
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-26T06%3A18%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=How%20clean%20is%20your%20ice%20machine?%20Revealing%20microbial%20amplification%20and%20presence%20of%20opportunistic%20pathogens%20in%20hospital%20ice-water%20machines&rft.jtitle=The%20Journal%20of%20hospital%20infection&rft.au=Cazals,%20M.&rft.date=2023-11&rft.volume=141&rft.spage=9&rft.epage=16&rft.pages=9-16&rft.issn=0195-6701&rft.eissn=1532-2939&rft_id=info:doi/10.1016/j.jhin.2023.08.007&rft_dat=%3Cproquest_cross%3E2854969567%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2854969567&rft_id=info:pmid/&rft_els_id=S0195670123002700&rfr_iscdi=true