Effective atomic numbers for CoCuNi alloys using transmission experiments

Effective atomic numbers for CuCoNi alloys against changing Ni contents were measured in the X-ray energy range from 15.746 to 40.930 keV. The gamma rays emitted a 241Am point source have been send on absorbers to be used transmission arrangement. The X-rays were counted by a Si(Li) detector with a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of quantitative spectroscopy & radiative transfer 2005-04, Vol.91 (4), p.485-491
Hauptverfasser: Icelli, O, Erzeneoglu, S, Karahan, I H, Cankaya, G
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Effective atomic numbers for CuCoNi alloys against changing Ni contents were measured in the X-ray energy range from 15.746 to 40.930 keV. The gamma rays emitted a 241Am point source have been send on absorbers to be used transmission arrangement. The X-rays were counted by a Si(Li) detector with a resolution of 160 eV at 5.9 keV. The compositions of the Ni films were determined to be 0.03, 0.47, 0.62, 1.23, 1.22 and 1.6 by a scanning electron microscopy in CuCoNi alloys prepared against changing Ni contents. CoCuNi alloy films were prepared with an electrodeposition technique. Also, the total effective atomic numbers of each alloy were estimated using mixture rule. The measured values were compared with estimated values for alloys.
ISSN:0022-4073
1879-1352
DOI:10.1016/j.jqsrt.2004.07.006